• 제목/요약/키워드: nonthermal atmospheric plasma

검색결과 25건 처리시간 0.034초

플라즈마 바이오과학 및 의학 (Plasma Bioscience and Medicines)

  • 최은하
    • 진공이야기
    • /
    • 제2권4호
    • /
    • pp.9-15
    • /
    • 2015
  • Nonthermal bio-compatible plasma (bioplasma) sources and their characteristics operating at atmospheric pressure could be used for biological cell interactions, especially for plasma bioscience and medicines. The electron temperatures and plasma densities of this bioplasma are measured to be 0.7 ~ 1.8 eV and $(3-5){\times}10^{14-15}cm^{-3}$, respectively. Herein, we introduced general schematic view of the plasma-initiated ultraviolet photolysis of water inside the biological solutions or living tissue for the essential generation mechanism of the reactive hydroxyl radical [OH] and hydrogen peroxide [$H_2O_2$], which may result in apoptotic cell death in plasma bioscience and medicines. Further, we surveyed the various nonthermal bioplasma sources including plasma jet, micro-DBD (dielectric barrier discharge) and nanosecond discharged plasma. The diseased biological protein, cancer, and mutated cells could be treated by these bioplasma sources or bioplasma activated water to result in their apoptosis for new paradigm of plasma bioscience and medicines.

Evaluation of Nonthermal Plasma Treatment by Measurement of Stored Citrus Properties

  • Seo, Youngwook;Park, Jong-Ryul;Park, Hoe Man
    • Journal of Biosystems Engineering
    • /
    • 제43권4호
    • /
    • pp.401-409
    • /
    • 2018
  • Decay of fruit is one of the greatest issues in fruit storage. Purpose: In this study, citrus sterilization was performed to evaluate a dry sterilization method using an atmospheric-pressure nonthermal plasma treatment based on a dielectric-barrier discharge technique. Methods: Citrus samples were stored under four different environmental conditions as follows: group A had cold storage with plasma treatment with a temperature of $6.2{\pm}1.0^{\circ}C$ and relative humidity (RH) of $93.4{\pm}8.2%$, group B had ambient-temperature storage with $22.9{\pm}2.3^{\circ}C$ and $82.1{\pm}4.5%$ RH, group C ambient-temperature storage with plasma treatment with $25.3{\pm}2.2^{\circ}C$ and $90.0{\pm}2.8%$ RH, and group D had cold storage with $5.7{\pm}1.0^{\circ}C$ and $93.4{\pm}6.5%$ RH. Results: As a result of citrus surface sterilization by plasma treatment, treatment groups A and C together showed an average of 16.1 CFU/mL of mold colonies, while control groups B and D showed an average of $2.2{\times}10^2CFU/mL$ or approximately 13 times greater than the treatment groups. Regarding the mean concentration of aerobic bacteria colonies, the treatment groups (A and C) and control groups (B and D) showed an average of 7.1 CFU/mL and $1.9{\times}10^3CFU/mL$, respectively. This is approximately a 270-fold difference in the concentration of pathogen colonies between treatment and control groups. Conclusions: The results showed the potential of nonthermal plasma treatment for citrus storage in enhancing storage duration and quality preservation.

Measurement of Plasma Parameters (Te and Ne) and Reactive Oxygen Species in Nonthermal Bioplasma Operating at Atmospheric Pressure

  • Choi, Eun Ha;Kim, Yong Hee;Kwon, Gi Chung;Choi, Jin Joo;Cho, Guang Sup;Uhm, Han Sup;Kim, Doyoung;Han, Yong Gyu;Suanpoot, Pradoong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.141-141
    • /
    • 2013
  • We have generated the needle-typed nonthermal plasma jet by using an Ar gas flow at atmospheric pressure. Diagnostics of electron temperature anddensity is critical factors in optimization of the atmospheric plasma jet source in accordance with the gas flow rate. We have investigated the electron temperature and density of plasma jet by selecting the four metastable Ar emission lines based on the atmospheric collisional radiative model and radial profile characteristics of current density, respectively. The averaged electron temperature and electron density for this plasma jet are found to be ~1.6 eV and ~$3.2{\times}10^{12}cm^{-3}$, respectively, in this experiment. The densities of OH radical species inside the various bio-solutions are found to be higher by about 4~9 times than those on the surface when the argon bioplasma jet has been bombarded onto the bio-solution surface. The densities of the OH radicalspecies inside the DI water, DMEM, and PBS are measured to be about $4.3{\times}10^{16}cm^{-3}$, $2.2{\times}10^{16}cm^{-3}$, and $2.1{\times}10^{16}cm^{-3}$, respectively, at 2 mm downstream from the surface under optimized Ar gas flow 250 sccm.

  • PDF

An Evaluation of the Repetitive Tooth Bleaching with Nonthermal Atmospheric Pressure Plasma

  • Nam, Seoul Hee;Kim, Gyoo Cheon;Hong, Jin Woo
    • International Journal of Oral Biology
    • /
    • 제41권4호
    • /
    • pp.243-251
    • /
    • 2016
  • This study was undertaken to achieve a high bleaching efficacy with plasma, through longer application and reparative bleaching processes, by different shade evaluation methods. Extracted human teeth were divided into 6 groups (n=10). All teeth were treated in pairs. Low concentration of 15% carbamide peroxide (CP) was applied, with and without plasma, for 10, 20, and 30-min tooth bleaching, respectively. The bleaching procedure was repeated once daily for four days. The teeth were maintained in a moist environment provided by artificial saliva. The Vitapan Classical shade guide and Commission Internationale de L'Eclairage (CIELAB) color system were collectively used to measure the bleaching efficacy. Color evaluation was statistically analyzed using Student t-test and one-way analysis of variance (ANOVA) complemented by Tukey's test. Combining the plasma with 15% CP showed significantly greater color changes compared to bleaching without plasma (p<0.05). A high bleaching efficacy with plasma is proportional to the repetitive application and the treatment time. A 30-min application with plasma provided the best bleaching. Repetitive bleaching showed lower probability of color relapse of the bleached tooth. The color change by shade guide correlated with the changes in CIELAB color system. A value of 1 color change units (CCU) conversion factor for overall color change (${\Delta}E$) values comparisons was 3.724 values. The two measuring methods provide a more accurate correspondence of color change. The repetitive and longer application for tooth bleaching, combined with plasma, has a strong bleaching effect and produces whiter teeth.

평판형 유전체 장벽 방전 반응기에서 충진물질에 따른 아세토나이트릴의 분해 특성 (Decomposition of Acetonitrile Using a Planar Type Dielectric Barrier Discharge Reactor Packed with Adsorption and Catalyst Materials)

  • 김관태;송영훈;김석준
    • 한국대기환경학회지
    • /
    • 제19권2호
    • /
    • pp.157-165
    • /
    • 2003
  • A combined process of non-thermal plasma and catalytic technique has been investigated to treat $CH_3$CN gas in the atmosphere. A planar type dielectric barrier discharge (DBD) reactor has been used to generate the non-thermal plasma that produces various chemically active species, such as O, N, OH, $O_3$, ion, electrons, etc. Several different types of the beads. which are Molecular Sieve (MS) 5A, MS 13X, Pt/alumina beads, are packed into the DBD reactor, and have been tested to characterize the effects of adsorption and catalytic process on treating the $CH_3$CN gas in the DBD reactor. The test results showed that the operating power consumption and the amounts of the by-products of the non-thermal plasma process can be reduced by the assistance of the adsorption and catalytic process.

Antimicrobial Effect of Low Temperature Atmospheric Plasma against Oral Pathogens

  • Kim, Young Min;Choi, Byul Bo Ra;Park, Sang Rye;Kim, Ji Young;Kim, Gyoo Cheon
    • International Journal of Oral Biology
    • /
    • 제40권4호
    • /
    • pp.167-173
    • /
    • 2015
  • The purpose of this study was to investigate the antibacterial effect of the low temperature atmospheric plasma device with needle tip designed for easy approach to the oral cavity and root canal against Streptococcus mutans, Enterococcus faecalis and Candida albicans. The antibacterial activities evaluated by measuring clear zone of agar plate smeared with each bacteria after plasma treatment. To quantify antibacterial effects, dilution plate method was used. In addition, scanning electron microscope (SEM) was used for observation of changes in bacterial morphology. As treatment time of plasma increased, the clear zone was enlarged. The death rate was more than 99%. The SEM results showed that the globular shape of bacteria was distorted. These results suggest that needle tip plasma could be an innovative device for prevention of dental caries, and treatment of apical infection and soft tissue diseases.

Characteristics of Bovine Teeth Whitening in Accordance with Gas Environments of Atmospheric Pressure Nonthermal Plasma Jet

  • Sim, Geon Bo;Kim, Yong Hee;Kwon, Jae Sung;Park, Daehoon;Hong, Seok Jun;Kim, Young Seok;Lee, Jae Lyun;Lee, Gwang Jin;Lim, Hwan Uk;Kim, Kyung Nam;Jung, Gye Dong;Choi, Eun Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.250.2-250.2
    • /
    • 2014
  • Currently, teeth whitening method which is applicable to dental surgery is that physician expertises give medical treatment to teeth directly dealed with a high concentration of hydrogen peroxide and carbamide peroxide. If hydrogen peroxide concentration is too high for treatment of maximized teeth whitening effect [1], it is harmful to the human body [2]. To the maximum effective and no harmful teeth whitening effect in a short period of time at home, we have observed the whitening effect using carbamide peroxide (15%) and a low-temperature atmospheric pressure plasma jet which is regulated by the Food and Drug Administration. The gas supplied conditions of the non-thermal atmospheric pressure plasma jet was with the humidified (0.6%) gas in nitrogen or air at gas flow rate of 1000 sccm. Also, the measurement of chemical species from the jet was carried out using the optical emission spectroscopy (OES), the evidence of increased reactive oxygen species compared to non-humidified plasma jet. We have found that the whitening effect of the plasma is very excellent through this experiment, when bovine teeth are treated in carbamide peroxide (15%) and water vapor (0.2 to 1%). The brightness of whitening teeth was increased up to 2 times longer in the CIE chromaticity coordinates. The colorimetric spectrometer (CM-3500d) can measure color degree of whitening effect.

  • PDF