• Title/Summary/Keyword: nonmagnetic material

Search Result 28, Processing Time 0.023 seconds

Development of High Strength and Low Loss Overhead Conductor(II) - Electric Properties (고강도 저손실 가공송전선의 개발(II) - 전기적 특성)

  • Kim, Byung-Geol;Kim, Shang-Shu;Park, Joo-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.12
    • /
    • pp.1159-1165
    • /
    • 2005
  • New conductor is developed by using high strength nonmagnetic steel(NM) wire as the core of overhead conductor This conductor is called ACNR overhead conductor(Aluminum Conductor Nonmagnetic Steel Reinforced). Formed by the combination of aluminum alloy wire and high strength nonmagnetic steel wire, it has about the same weight and diameter as conventional ACSR overhead conductor. To enhance properties beneficial in an electrical and mechanical conductor during the Process of high strength nonmagnetic steel wire, we made a large number of improvements and modifications in the working process, aluminum cladded method, and other process. ACNR overhead conductor, we successfully developed, has mechanical and electrical properties as good as or even better than conventional galvanized wire. Microstructure of raw material NM wire was austenite and then deformed martensite after drawing process. Strength at room temperature is about $180kgf/mm^2\~200kgf/mm^2$. The conductivity at 0.78 mm thickness of Aluminum cladded M wire is about $7\%$ IACS higher than $20\%$IACS of HC wire used as core of commercial ACSR overhead conductor. The corrosion resistance is about 3 times higher than that of HC wire.

Development of High Strength and Low Loss Overhead Conductor(I) - Mechanical Properties (고강도 저손실 가공송전선의 개발(I) - 기계적 특성)

  • Kim, Byung-Geol;Kim, Shang-Shu;Park, Joo-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.12
    • /
    • pp.1152-1158
    • /
    • 2005
  • New conductor is developed by using high strength nonmagnetic steel(NM) wire as the core of overhead conductor. This conductor is called ACNR overhead conductor(Aluminum Conductor Nonmagnetic Steel Reinforced). Formed by the combination of aluminum alloy wire and high strength nonmagnetic steel wire, it has about the same weight and diameter as conventional ACSR overhead conductor. To enhance properties beneficial in an electrical and mechanical conductor during the process of high strength nonmagnetic steel wire, we made a large number of improvements and modifications in the working process, aluminum cladded method, and other process. ACNR overhead conductor, we successfully developed, has mechanical and electrical properties as good as or even better than conventional galvanized wire. Microstructure of raw material M wire was austenite and then deformed martensite after drawing process. Strength at room temperature is about $180kgf/mm^2\~200kgf/mm^2$. NM wire developed as core of overhead conductor shows heat resistant characteristics higher than that of HC wire used as core of commercial ACSR overhead conductor, Strength loss was not occur at heat resistant test below $600^{\circ}C$. Fatigue strength of vibration fatigue is about $32kgf/mm^2\~35kgf/mm^2$ and that of tension-tension fatigue is $90kgf/mm^2\~120kgf/mm^2$ which is $50\~65\%$ of tensile strength.

Exchange Coupling of FerromagneticlAntiferrmagnetic through Nonmagnetic Layer in Antiferromagnetic

  • Kim Jong-Min;Kim Young-Sung
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2004.12a
    • /
    • pp.200-201
    • /
    • 2004
  • The $H_{EB}$ was investigated for exchange coupling $20\;{\AA}\;Fe/x\;{\AA}\;NiO\;(type-I samples)$, $20\;{\AA}\;Fe/x\;{\AA}$ nonmagnetic layer $(MgO, Ag, Cu)/(500-x{\AA})$ NiO (type-II smaples). In type-I samples, the $H_{EB}$ is long-range coupling when looking from the point of view of the AFM. The $H_{EB}$ consistent with a generalized Meiklejohn-Bean approach. The critical thickness, which $H_{EB}$ is observed, is $130\;{\AA}$. In type-II samples, MgO layer more decouples the thin interfacial NiO from bottom NiO than other nonmagnetic layer. Nd the decoupling of Ag smallest. This means that the Ag layer has strong coupling the thin interfacial NiO with bottom NiO.

  • PDF

MAGNETO-OPTICAL INVESTIGATION OF LOW-DEMENSIONAL MAGNETIC STRUCTURES

  • Shalyguina, E.E.;Kim, Cheol-Gi
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.13-16
    • /
    • 2003
  • Magnetic and magneto-optical properties of Fe/Pt/Fe, Co/Pd/Co trilayers and also the sandwiches with wedge-shaped magnetic (Fe, Co) and nonmagnetic (Pt, Pd) layers were investigated. The oscillatory behavior of the saturation field $H_{s}$ of the studied trilayers with changing the thickness of the nonmagnetic layer (NML) $t_{NML}$ was revealed. That was explained by the exchange coupling between ferromagnetic layers (FML) through the nonmagnetic spacer. For the first time, oscillations of the transverse Kerr effect (TKE) with changing the Pt- and Pd-wedge thickness were discovered. Period of these oscillations was found to depend on the FML thickness and the photon energy of the incident light. TKE spectra of the examined samples were discovered to modify very strongly with increasing $t_{NML}$. The discovered peculiarities of magneto-optical properties of thin-film systems were explained by a concept of the spin-polarized quantum well states in the pt and Pd layers.

  • PDF

Differential Absorption Analysis of Nonmagnetic Material in the Phantom using Dual CT

  • Kim, Ki-Youl;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.286-292
    • /
    • 2016
  • This study evaluates the change of computer tomography (CT) number in the case of the metal artifact reduction (MAR) algorithm, using the phantom. The images were obtained from dual CT using a gammex 467 tissue characterization phantom, which is similar to human tissues. The test method was performed by dividing pre and post MAR algorithm and measured CT values of nonmagnetic materials within the phantom. In addition, the changes of CT values for each material were compared and analyzed after measuring CT values up to 140 keV, using the spectral HU curve followed by CT scan. As a result, in the cases of N rod (trabecular bone) and E rod (trabecular bone), the CT numbers decreased as keV increasing but were constant above 90 keV. In the cases of I rod (dense bone) and K rod (dense bone), the CT numbers also decreased as keV increased but were uniform above 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of J rod (liver), D rod (liver), L rod (muscle), and F rod (muscle). For A rod (adipose), G rod (adipose), B rod (breast) and O rod (breast), the CT numbers increased as keV increased but were constant after 90 keV. The CT numbers from 40 keV to 140 keV were consistent in the cases of C rod (lung (exhale)), P rod (lung (exhale)), M rod (lung (inhale)) and H rod (lung (exhale)). Conclusively, because dual CT exhibits no changes in image quality and is able to analyze nonmagnetic materials by measuring the CT values of various materials, it will be used in the future as a useful tool for the diagnosis of lesions.

Magnetic and Microwave Absorbing Properties of Ti-and Co-Substituted Barium Ferrite (BaFe12-2X TiXCoXO19)

  • Han-Shin Cho;Yong-Jin Kim;Sung-Soo Kim
    • Journal of Magnetics
    • /
    • v.4 no.2
    • /
    • pp.65-68
    • /
    • 1999
  • The M-type barium ferrite ($BaFe_{12}O_{19}$) is well known magnetic material to be used as a permanent magnet due to its strong uniaxial anisotropy. The substitution of nonmagnetic $Ti^{+4}$ and magnetically weak $Co+^2ion for Fe^{+3}$ to its strong uniaxial anisotropy. The substitution of nonmagnetic $Ti^{+4}$ and magnetically weak $Co+^2ion for Fe^{+3}$ sublattices reduces the uniaxial anisotropy and those compounds open a new application field of noise suppressor at high frequencies. In this study, the magnetic and microwave absorbing properties are investigated in Ti-and Co-substituted barium ferrites ($BaFe_{12-2X} Ti_XCo_XO_{19}$). The saturated magnetization decreases linearly with the substitution of Ti and Co. The rapid drop in coercive force is observed with Ti and Co substitution upto x=1.2. The magnetic permeability spectrum shows the natural magnetic resonance in the specimens with small coercive force and large attenuation of microwave is predicted in those specimens at high frequencies (above 4 GHz).

  • PDF

Resonant Network Design and Verification of Induction Cooker for Heating Nonmagnetic Vessel (비자성체 용기 가열을 위한 Induction Cooker 공진 네트워크 설계 및 검증)

  • Jang, Eun-Su;Park, Sang-Min;Joo, Dong-Myoung;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.6
    • /
    • pp.504-509
    • /
    • 2017
  • This paper proposes a procedure for designing a resonant network for induction cookers that enables the induction heating of magnetic and non-magnetic vessels. In order to design such network, the range of operating frequency must be determined according to the material of the vessels by measuring several parameters, such as equivalent resistance and inductance, which are reflected in the working coil of the vessels. Through this process, the capacitance of the resonant capacitor is determined. The PSIM simulation and experiment results verify the feasibility of the proposed design and the heating performance of the designed resonant network.

Measurement Feasibility Assessment of Coating Film Thickness using Dual Sensor (이중센서를 이용한 코팅막 두께 측정 가능성 평가)

  • 김주현;김성렬;김정욱;김화영;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.78-81
    • /
    • 2004
  • A technical performance of the coating depends greatly on the thickness of painting film or coating film. Therefore the confirmed report of the technique to measure accurately is essential to the coating film thickness for the assessment about a coating quality performance. In this paper, two gap sensors - eddy current gap sensor and capacitance gap sensor - which has a different operating principle were used to measure the thickness of a nonmagnetic substance coating film such as paint, enamel or ceramic that was coated on the metallic material. A capacitance gap sensor was used to measure the distance between the sensor head and a coating film and an eddy current gap sensor to measure the distance between the sensor head and a base metal. Then the thickness of a coating film was obtained by the difference of two measurement value. At this result, the suggested dual sensor can measure an arbitrary film thickness to be coated on a base metal as the measurement value of coating thickness exists accurately within the 2% error.

  • PDF

Magnetorheological Finishing (자성유체를 이용한 연마)

  • 신영재;이응숙;황경현;김경웅
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.775-778
    • /
    • 2000
  • Magnetorheological Finishing(MRF) is a newly developed and recently commercialized for finishing optical components. The magnetorheological fluid consists of a water based suspension of carbonyl iron, nonmagnetic polishing abrasives, and small amounts of stabilizer. Theoretical analysis of MRF, based on Bingham lubrication theory, is illustrated and a correlation between surface shear stress on the workpiece and material removal is obtained.

  • PDF

A study on Modeling and Experiments of an Eddy Current Damping (와전류감쇠의 모델링 및 특성 실험에 관한 연구)

  • Park, Jung-Sam;Kwag, Dong-Gi;Bae, Jae-Sung;Hwang, Jai-Hyuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.250-254
    • /
    • 2008
  • Eddy currents are induced when a nonmagnetic conductive material is moving subjected to the magnetic field due to a permanent magnet. These currents circulates in the conductive material and are dissipated, causing a repulsive force between the magnet and the conductor. Using this concept, the eddy current damping can be used as a viscous damping. The present study investigates the characteristics of a magnetic damping analytically and experimentally. The theoretical model of a eddy current damping is developed from electromagnetics and is verified from experiments. The drop test of a magnet in the cooper tube shows that the present model can accurately predict the damping force. Additionally, the dynamic test of a eddy current damping is carried to verify the present model.

  • PDF