• 제목/요약/키워드: nonlinear pushdown analysis

검색결과 9건 처리시간 0.022초

Element loss analysis of concentrically braced frames considering structural performance criteria

  • Rezvani, Farshad Hashemi;Asgarian, Behrouz
    • Steel and Composite Structures
    • /
    • 제12권3호
    • /
    • pp.231-248
    • /
    • 2012
  • This research aims to investigate the structural behavior of concentrically braced frames after element loss by performing nonlinear static and dynamic analyses such as Time History Analysis (THA), Pushdown Analysis (PDA), Vertical Incremental Dynamic Analyses (VIDA) and Performance-Based Analysis (PBA). Such analyses are to assess the potential and capacity of this structural system for occurrence of progressive collapse. Besides, by determining the Failure Overload Factors (FOFs) and associated failure modes, it is possible to relate the results of various types of analysis in order to save the analysis time and effort. Analysis results showed that while VIDA and PBA according to FEMA 356 are mostly similar in detecting failure mode and FOFs, the Pushdown Overload Factors (PDOFs) differ from others at most to the rate of 23%. Furthermore, by sensitivity analysis it was observed that among the investigated structures, the eight-story frame had the most FOF. Finally, in this research the trend of FOF and the FOF to critical member capacity ratio for the plane split-X braced frames were introduced as a function of the number of frame stories.

Evaluation of dynamic increase factor in progressive collapse analysis of steel frame structures considering catenary action

  • Ferraioli, Massimiliano
    • Steel and Composite Structures
    • /
    • 제30권3호
    • /
    • pp.253-269
    • /
    • 2019
  • This paper investigates the effects of the tensile catenary action on dynamic increase factor (DIF) in the nonlinear static analysis for progressive collapse of steel-frame buildings. Numerical analyses were performed to verify the accuracy of the empirical and analytical expressions proposed in the literature in cases where the catenary action is activated. For this purpose, nonlinear static and dynamic analyses of a series of steel moment frame buildings with a different number of spans and stories were carried out following the alternate path method. Different column removal scenarios were considered as separate load cases. The dynamic increase factor that approximately compensates for the dynamic effects in the nonlinear static analysis was selected so to match results from the nonlinear dynamic analysis. The study results showed that the many expressions in literature may not work in cases where the catenary stage is fully developed.

강판벽이 설치된 건물의 연쇄붕괴 저항성능 (Progressive Collapse Resisting Capacity of Building Structures with Infill Steel Panels)

  • 이하나;권광호;김진구
    • 한국전산구조공학회논문집
    • /
    • 제25권1호
    • /
    • pp.19-26
    • /
    • 2012
  • 본 논문에서는 강판벽이 설치된 골조 구조물의 연쇄붕괴 거동을 비선형 정적 pushdown 해석을 이용하여 평가하였다. 해석모델은 중력하중에 대해서 설계된 2층 2경간 철골구조물이며, 중앙 기둥을 제거하고 하중을 서서히 증가시키며 하중-변위 관계를 구하였다. 구조물의 전체적인 거동뿐만 아니라 부분적인 응력과 변형을 파악하기 위하여 ABAQUS를 이용한 유한요소해석을 수행하였다. 해석을 통해서 구조물의 경간 길이 및 설치된 강판의 두께의 변화에 따른 연쇄붕괴 거동을 평가하였으며, 샛기둥을 이용하여 강판을 분할하고 분할된 강판의 위치에 따른 연쇄붕괴 성능의 변화를 관찰하였다. 해석결과에 따르면 경간의 길이가 증가할수록 연쇄붕괴를 방지하기 위하여 요구되는 강판의 두께 또한 증가하며, 분할된 강판의 수가 증가할수록 연쇄붕괴에 대한 저항성능이 약간 증가하지만 그 영향은 그리 크지 않은 것으로 나타났다. 또한 개구부로 인하여 일부 경간에만 강판이 설치된 경우에도 연쇄붕괴 저항성능이 어느 정도 증가하는 것으로 나타났다.

Dynamic increase factor for progressive collapse analysis of semi-rigid steel frames

  • Zhu, Yan Fei;Chen, Chang Hong;Yao, Yao;Keer, Leon M.;Huang, Ying
    • Steel and Composite Structures
    • /
    • 제28권2호
    • /
    • pp.209-221
    • /
    • 2018
  • An empirical and efficient method is presented for calculating the dynamic increase factor to amplify the applied loads on the affected bays of a steel frame structure with semi-rigid connections. The nonlinear static alternate path analysis is used to evaluate the dynamic responses. First, the polynomial models of the extended end plate and the top and seat connection are modified, and the proposed polynomial model of the flush end plate connection shows good agreement as compared with experimental results. Next, a beam model with nonlinear spring elements and plastic hinges is utilized to incorporate the combined effect of connection flexibility and material nonlinearity. A new step-by-step analysis procedure is established to obtain quickly the dynamic increase factor based on a combination of the pushdown analysis and nonlinear dynamic analysis. Finally, the modified dynamic increase factor equation, defined as a function of the maximum ratio value of energy demand to energy capacity of an affected beam, is derived by curve fitting data points generated by the different analysis cases with different column removal scenarios and five types of semi-rigid connections.

특수 중심가새골조의 연쇄붕괴 저항능력 평가 (Evaluation of Progressive Collapse Resisting Capacity of Special Concentrically Braced Frames)

  • 이영호;김진구;최현훈
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.319-324
    • /
    • 2008
  • In this study the progressive collapse potential of special concentrically braced frames were investigated using the nonlinear static. All of seven different brace types were considered. According to the pushdown analysis results, most braced frames designed according to current design codes satisfied the design guidelines for progressive collapse initiated by loss of a first story mid-column; however most model structures showed brittle failure mode. This was caused by buckling of columns after compressive braces buckled. Among the braced frames considered, the inverted-V type braced frames showed superior ductile behavior during progressive collapse.

  • PDF

Structural robustness of RC frame buildings under threat-independent damage scenarios

  • Ventura, Antonio;De Biagi, Valerio;Chiaia, Bernardino
    • Structural Engineering and Mechanics
    • /
    • 제65권6호
    • /
    • pp.689-698
    • /
    • 2018
  • This study focuses on a novel procedure for the robustness assessment of reinforced concrete (RC) framed structures under threat-independent damage scenarios. The procedure is derived from coupled dynamic and non-linear static analyses. Two robustness indicators are defined and the method is applied to two RC frame buildings. The first building was designed for gravity load and earthquake resistance in accordance with Eurocode 8. The second was designed according to the tie force (TF) method, one of the design quantitative procedures for enhancing resistance to progressive collapse. In addition, in order to demonstrate the suitability and applicability of the TF method, the structural robustness and resistance to progressive collapse of the two designs is compared.

Effect of column loss location on structural response of a generic steel moment resisting frame

  • Rezvani, Farshad Hashemi;Jeffers, Ann E.;Asgarian, Behrouz;Ronagh, Hamid Reza
    • Steel and Composite Structures
    • /
    • 제25권2호
    • /
    • pp.217-229
    • /
    • 2017
  • The effect of column loss location on the structural response of steel moment resisting frames (MRF) is investigated in this study. A series of nonlinear static and dynamic analyses were performed to determine the resistance of a generic frame to an arbitrary column loss and detect the structural members that are susceptible to failure progression beyond that point. Both force-controlled and deformation-controlled actions based on UFC 4-023-03 and ASCE/SEI 41-06 were implemented to define the acceptance criteria for nine APM cases defined in this study. Results revealed that the structural resistance against an arbitrary column loss in the top story is at least 80% smaller than that of the bottom story. In addition, it was found that the dynamic increase factor (DIF) at the failure point is at most 1.13.

가새골조의 연쇄붕괴 저항성능 (Progressive Collapse Resisting Capacity of Braced Frames)

  • 김진구;이영호;최현훈
    • 한국전산구조공학회논문집
    • /
    • 제21권5호
    • /
    • pp.429-437
    • /
    • 2008
  • 본 논문에서는 비선형 정적해석 및 동적해석을 이용하여 가새골조의 연쇄붕괴 저항능력을 평가하였다. 모두 아홉 개의 서로 다른 가새 형태를 고려하였으며, 모멘트골조의 해석 결과와 비교하였다 비탄성 정적해석 결과에 따르면 현행 기준에 따라 설계된 저층 가새골조는 1층 중앙에 위치한 기둥이 제거될 경우 연쇄붕괴 저항성능 기준을 만족하는 것으로 나타났으나 대부분 취성적인 파괴모드를 나타내었다. 특히 압축가새가 좌굴한 후 인장가새가 인장력을 발휘하기 전에 취약한 층의 기둥이 좌굴하는 것으로 나타냈다. Inverted-V형 가새골조의 경우가 가장 연성도 면에서 우수한 것으로 나타났다. 동적 해석 결과에 따르면 모든 가새골조는 중앙에 위치한 기둥이 제거될 경우 붕괴되지 않으며, 동일한 규모의 모멘트 저항골조에 비해 진동이나 처짐량이 작은 것으로 나타났다.

Influence of seismic design rules on the robustness of steel moment resisting frames

  • Cassiano, David;D'Aniello, Mario;Rebelo, Carlos;Landolfo, Raffaele;da Silva, Luis S.
    • Steel and Composite Structures
    • /
    • 제21권3호
    • /
    • pp.479-500
    • /
    • 2016
  • Seismic design criteria allow enhancing the structural ductility and controlling the damage distribution. Therefore, detailing rules and design requirements given by current seismic codes might be also beneficial to improve the structural robustness. In this paper a comprehensive parametric study devoted to quantifying the effectiveness of seismic detailing for steel Moment Resisting Frames (MRF) in limiting the progressive collapse under column loss scenarios is presented and discussed. The overall structural performance was analysed through nonlinear static and dynamic analyses. With this regard the following cases were examined: (i) MRF structures designed for wind actions according to Eurocode 1; (ii) MRF structures designed for seismic actions according to Eurocode 8. The investigated parameters were (i) the number of storeys; (ii) the interstorey height; (iii) the span length; (iv) the building plan layout; and (v) the column loss scenario. Results show that structures designed according to capacity design principles are less robust than wind designed ones, provided that the connections have the same capacity threshold in both cases. In addition, the numerical outcomes show that both the number of elements above the removed column and stiffness of beams are the key parameters in arresting progressive collapse.