• 제목/요약/키워드: nonlinear coupling

검색결과 356건 처리시간 0.023초

Nonlinear Aeroelastic Analysis of a High-Aspect-Ratio Wing with Large Deflection Effects

  • Kim, Kyung-Seok;Lim, In-Gyu;Lee , In;Yoo, Jae-Han
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제7권1호
    • /
    • pp.99-105
    • /
    • 2006
  • In this study, nonlinear static and dynamic aeroelastic analyses for a high-aspect-ratio wing have been performed. To achieve these aims, the transonic small disturbance (TSD) theory for the aerodynamic analysis and the large deflection beam theory considering a geometrical nonlinearity for the structural analysis are applied, respectively. For the coupling between fluid and structure, the transformation of a displacement from the structural mesh to the aerodynamic grid is performed by a shape function which is used for the finite element and the inverse transformation of force by work equivalent load method. To validate the current method, the present analysis results of a high-aspect-ratio wing are compared with the experimental results. Static deformations in the vertical and torsional directions caused by an angle of attack and gravity loading are compared with experimental results. Also, static and dynamic aeroelastic characteristics are investigated. The comparisons of the flutter speed and frequency between a linear and nonlinear analysis are presented.

벡터계 정규 형식을 이용한 전력시스템 제어기 설치 위치 선정 (Identification of Optimum Sites for Power System Controller using Normal Forms of Vector Field)

  • 장길수;이인수;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권4호
    • /
    • pp.227-233
    • /
    • 2004
  • In stressed power system due to the presence of increased nonlinearity and the existence of nonlinear modal interactions. there exist some limitations to the use of conventional linear system theory to identify the optimum sites for a controller. This paper suggests an approach based on the method of normal forms to identify the optimum sites for controllers with incorporating the nonlinear interaction . In this paper, nonlinear participation factors and coupling factors are proposed as measures of the nonlinear interactions, and identification procedure of optimum sites for a controller is also proposed. The proposed procedure is applied to the 10-generator New England System and the KEPCO System in the year of 2010, and the results illustrate its capabilities.

유한요소와 경계요소의 조합에 의한 반무한 영역 문제의 비선형해석 (A Nonlinear Analysis of Half Plane Problems Using Coupling of Finite Elements and Boundary Elements)

  • 김문겸;임윤묵
    • 전산구조공학
    • /
    • 제2권1호
    • /
    • pp.55-64
    • /
    • 1989
  • 본 논문에서는 경계요소법과 비선형 유한요소법의 각 장점을 이용하여 반무한 영역을 가진 구조체의 해석방법을 논하였다. 여기서, 반무한 경계요소는 Melan의 반무한 평면에 대한 해로부터 구성하였다. 비선형 유한요소는 지하구조물에서 주로 접할 수 있는 탄소성 재료의 비균질성 또는 불규칙성을 모형화하기 위하여 사용하였다. 본 조합방법의 검증을 위하여 얕은 터널에 일정한 내압이 작용하는 경우를 택하여, 비선형 유한요소법과 조합방법의 결과를 비교하였다. 비교결과, 개발된 조합방법이 다른 해석방법에 비해 충분한 정확도를 가짐을 알 수 있었다.

  • PDF

독립형 마이크로그리드에서 비선형 부하에 대한 고품질 전압제어 (Effective Voltage Quality Control under Nonlinear Loads in Islanded Microgrid)

  • ;이홍희
    • 전력전자학회논문지
    • /
    • 제21권6호
    • /
    • pp.465-472
    • /
    • 2016
  • A nonlinear load causes harmonic distortion and hampers the performance of other loads or distributed generation (DG) sources connected to the point of common coupling (PCC). This study proposes a new control strategy to reduce harmonic components, such as fifth and seventh harmonics, at the PCC under nonlinear loads in islanded microgrids, which comprise more than two DG sources. The proposed control scheme enables the DG source to share the power commanded by the control center as well as to compensate for the voltage harmonics at the PCC. The reference current is estimated from the voltage harmonics and injecting power; thus, the control scheme is implemented without any additional hardware devices. The simulation and experimental results are presented to verify the effectiveness of the proposed control method.

벡터계 정규 형식을 이용한 전력시스템 제어기 설치 위치 선정 (Identification of Optimum Sites for Power System Controller using Normal Forms of Vector Field)

  • 장길수;이인수;권세혁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권4호
    • /
    • pp.227-227
    • /
    • 2004
  • In stressed power system due to the presence of increased nonlinearity and the existence of nonlinear modal interactions. there exist some limitations to the use of conventional linear system theory to identify the optimum sites for a controller. This paper suggests an approach based on the method of normal forms to identify the optimum sites for controllers with incorporating the nonlinear interaction . In this paper, nonlinear participation factors and coupling factors are proposed as measures of the nonlinear interactions, and identification procedure of optimum sites for a controller is also proposed. The proposed procedure is applied to the 10-generator New England System and the KEPCO System in the year of 2010, and the results illustrate its capabilities.

Advanced Repetitive Controller to Improve the Voltage Characteristics of Distributed Generation with Nonlinear Loads

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.409-418
    • /
    • 2013
  • This paper presents an enhanced control strategy which consists of a proportional-integral controller and a repetitive controller (RC) for improving the voltage performance of distributed generation (DG) under nonlinear load conditions. The proposed voltage controller is able to maintain a sinusoidal voltage at the point of common coupling (PCC) of the DG regardless of the harmonic voltage drop in the system impedance due to nonlinear load currents. In addition, by employing the delay time of the RC at one-sixth of the fundamental period, the proposed RC can overcome the slow response drawback of the traditional PI-RC. The proposed control strategy is analyzed and the design of the RC is presented in detail. The feasibility of the proposed control strategy is verified through simulation and experimental results.

A New Control Strategy for Distributed Generation under Nonlinear loads

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.256-257
    • /
    • 2012
  • This paper presents a new control strategy to improve voltage performance of distributed generation (DG) under nonlinear loads. The proposed voltage controller consists of a proportional-integral and a repetitive controller where the repetitive controller behaves as a bank of resonant controllers to compensate harmonic voltage drop on system impedance due to nonlinear load current. As a result, the voltage at the point of common coupling (PCC) of the DG is regulated to be sinusoidal waveform regardless of the presence of nonlinear loads. In order to validate the effectiveness of the proposed voltage controller, simulations are carried out using PSIM software and results are compared with those with the conventional PI controller.

  • PDF

연성 효과를 고려한 마이크로스피커 왜율분석 (Analysis of Total Harmonic Distortion in Microspeaker Considering Coupling Effect)

  • 권중학;김광석;방기창;황상문
    • 한국소음진동공학회논문집
    • /
    • 제18권4호
    • /
    • pp.473-479
    • /
    • 2008
  • With the advent of mobile phone, digital multimedia broadcasting(DMB) service is to be realized for multimedia data communication. For an acoustic part, a smaller and lighter microspeaker is also soon to be realized as an MP3 song player and a speakerphone. Sound quality in the microspeaker is becoming more important in mobile phones. It is evaluated by total harmonic distortion(THD). THD is the proportion of higher order frequencies output response to sinusoidal input signal. It is affected by uneven magnetic distribution and nonlinear response of diaphragm. In this paper, harmonic distortion is analyzed by considering magnetic and mechanical coupling effects. Simulated results of THD are compared with experimental data. Results show that THD in lower frequency range is higher due to high displace on voice coil and high mechanical response of high order frequency.

망간산화물을 이용한 수용액내 Bisphenol-A의 산화 반응성 평가 (Application of Manganese Oxide for the Oxidative Degradation of Bisphenol-A in Aqueous Phase)

  • 지상현;고석오
    • 한국물환경학회지
    • /
    • 제23권5호
    • /
    • pp.659-664
    • /
    • 2007
  • The objective of this study is to evaluate the detoxification method for the endocrine disrupting chemicals by manganese oxide. Manganese coated sand and bisphenol-A (BPA) was used as the reactive medium and the contaminant. Results showed that manganese oxide effectively degrades BPA by oxidative coupling reaction. The nonlinear oxidative coupling reaction orders were obtained for BPA and oxide, respectively. The reaction rate of BPA decreased as initial BPA concentration increased, as oxide loading decreased and as pH increased. The higher ionic strength, the higher reaction rate was observed. Divalent cations were adsorbed on the oxide surfaces, resulting in the decreased degradation rate of BPA.

종/횡운동 coupling 상태에 대한 비행역학 연구 (Study on dynamics of the cross-couplig phenomenon between longitudinal and lateral motion)

  • 김성관;하철근
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1300-1303
    • /
    • 1996
  • In this paper a typical problem is examined that a light, general aviation airplane, such as Cessna or Navion, in gliding turn flight shows helical-dive phenomenon when pilots try to stop the descent by using elevator only. It is known from pilot's experience that in a certain flight trim it is impossible to recover from helical-dive by using elevator only. From this study it is shown that helical-dive phenomenon is involved with longitudinal/lateral dynamics coupling to airplane's aerodynamics. Also this phenomenon consists of three parts of flight dynamics; first of all, fast longitudinal motion occurs, then is followed by a little slow lateral motion, and finally logitudinal/lateral coupled motion is fully developed.

  • PDF