• Title/Summary/Keyword: nonlinear connections

Search Result 247, Processing Time 0.024 seconds

Empirical Equations for Checking Validity of Access Hole Parameters for WUF-W Connections (WUF-W 접합부의 액세스 홀 형상변수 타당성 평가를 위한 경험식 제안)

  • Han, Sang Whan;Yoon, Yong;Kim, Y. Debbie
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.4
    • /
    • pp.303-310
    • /
    • 2017
  • The welded unreinforced flange-welded web(WUF-W) connection is an all-welded moment connection, which is qualified for special moment frame(SMF) connections. However, previous studies reported that some WUF-W connections did not meet the drift requirement specified for SMF connections and such unexpected connection performance was resulted from weld access hole geometry. The objective of this study is to determine the permissible ranges of major access hole parameters such as access hole slope and the length of flat portion that lead to the satisfactory performance of WUF-W connections using Nonlinear finite element analyses are conducted. This study also proposes simple empirical equations to check the validity of access hole parameters to be selected in design process.

Behavior of simple precast high-strength concrete beams connected in the maximum bending moment zone using steel extended endplate connections

  • Magdy I. Salama;Jong Wan Hu;Ahmed Almaadawy;Ahmed Hamoda;Basem O. Rageh;Galal Elsamak
    • Steel and Composite Structures
    • /
    • v.50 no.6
    • /
    • pp.627-641
    • /
    • 2024
  • This paper presents an experimental and numerical study to investigate the behavior of the precast segmental concrete beams (PSCBs) utilizing high-strength concrete (HSC) connected in the zone of the maximum bending moment using steel extended endplate connections (EECs). The experimental study consisted of five beams as follows: The first beam was the control beam for comparison, which was an unconnected one-piece beam made of HSC. The other four other beams consisted of two identical pieces of precast concrete. An important point to be noted is that at the end of each piece, a steel plate was used with a thickness of 10 mm. Moreover, this steel plate was welded to the lower and upper reinforcing bars of the beam. Furthermore, the steel plate was made to connect the two pieces using the technique of EECs. Several variables were taken in these four beams, whether from the shape of the connection or enhancing the behavior of the connection using the post-tensioning technique. EECs without stiffeners were used for some of the tested beams. The behavior of these connections was improved using stiffeners and shear bolts. To get accurate results, a comparison was made between the behaviors of the five beams. Another important point to be noted is that Abaqus and SAP2000 programs were used to investigate the behavior of PSCBs and to ensure the accuracy of the modeling process which showed a good agreement with the experimental results. Additionally, the simplified modeling using SAP2000 was able to model the nonlinear behavior of PSCBs connected using steel EECs. It was found that the steel pre-tensioned bolted EECs, reinforced with steel stiffeners and shear anchors, could be used to connect the precast HSC segmental beams via the internal pre-stressing technique.

Seismic Performance Evaluation of Post-Northridge WUF-B Connections Frame (Post-Northridge WUF-B 접합부 골조의 내진 성능 평가)

  • Han, Sang Whan;Moon, Ki Hoon;Jung, Ji Eun;Lee, Ki Hak
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.751-760
    • /
    • 2007
  • The purpose of this study is to evaluate the seismic performance of the frame which is assumed to be used with Welded Unreinforced Flange-Bolted web (WUF-B) connections and detailed in compliance with FEMA 350 recommended seismic design criteria. In FEMA 350, these types of connections are only valid for Ordinary Moment-Resisting Steel Frames (OMRSFs). For this purpose, based on test results, we proposed an analytical model for the Post-Northridge WUF-B connections with different panel zone strength ratios. Using the connection model, SAC Phase II three and nine-story frames were modeled and analyzed. From a nonlinear static pushover analysis, ductility, maximum strength, and the maximum interstory drift ratio were investigated for buildings with Post-Northridge details. Moreover, the maximum interstory drift ratio of each performance level (IO and CP) was also investigated through Incremental Dynamic Analysis (IDA). Analytical results were compared with those of buildings with either Pre-Northridge connection or ductile connections with no fracture. The analytical results showed that buildings with Post-Northridge WUF-B connections provide superior strength and interstory drift ratio capacity than buildings with Pre-Northridge WUF-B connections.

3-D analysis of sloshing motion in a fluid container with nonlinear boundary conditions (비선형 경계조건을 고려한 내부 유체의 3차원 자유수면 유동해석)

  • 김문겸;임윤묵;조경환;박종헌;이성민
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.177-184
    • /
    • 2002
  • Large amplitude sloshing can occur in contained fluid region due to the seismic ground motion. Also, The pressure by large amplitude sloshing damages the connections between the wall and roof of a fluid container and causes outflow of contained fluid. Therefore, to predict the dynamic behavior accurately, three dimensional analysis with the nonlinear boundary condition must be performed. In this study, the numerical solution procedure is developed using the boundary element method with the Lagrangian particle approach. In order to demonstrate the accuracy and validity of the developed method, the fluid motion for a free oscillation with small amplitude and a forced vibration are analyzed. And the numerical results are compared with the linear theory results and the previous studies with the nonlinear boundary condition.

  • PDF

Nonlinear modeling of flat-plate structures using grid beam elements

  • Tian, Ying;Chen, Jianwei;Said, Aly;Zhao, Jian
    • Computers and Concrete
    • /
    • v.10 no.5
    • /
    • pp.489-505
    • /
    • 2012
  • This paper presents a simplified grid beam model for simulating the nonlinear response of reinforced concrete flat-plate structures. The beam elements are defined with nonlinear behavior for bending moment and torsion. The flexural stiffness and torsional strength of the beam elements are defined based on experimental data to implicitly account for slab two-way bending effects. A failure criterion that considers the interaction between the punching strength and slab flexural behavior is incorporated in the model. The effects of bond-slip of slab reinforcement on connection stiffness are examined. The proposed grid beam model is validated by simulating large-scale tests of slab-column connections subjected to concentric gravity loading and unbalanced moment. This study also determines the critical parameters for a hysteretic model used to simulate flat-plates subjected to cyclic lateral loading.

Seismic performance evaluation of RC bearing wall structures

  • Rashedi, Seyed Hadi;Rahai, Alireza;Tehrani, Payam
    • Computers and Concrete
    • /
    • v.30 no.2
    • /
    • pp.113-126
    • /
    • 2022
  • Reinforced concrete bearing walls (RCBWs) are one of the most applicable structural systems. Therefore, vulnerability analysis and rehabilitation of the RCBW system are of great importance. In the present study, in order to the more precise investigation of the performance of this structural resistant system, pushover and nonlinear time history analyses based on several assumptions drawing upon experimental research were performed on several models with different stories. To validate the nonlinear analysis method, the analytical and experimental results are compared. Vulnerability evaluation was carried out on two seismic hazard levels and three performance levels. Eventually, the need for seismic rehabilitation with the basic safety objective (BSO) was investigated. The obtained results showed that the studied structures satisfied the BSO of the seismic rehabilitation guidelines. Consequently, according to the results of analyses and the desired performance, this structural system, despite its high structural weight and rigid connections and low flexibility, has integrated performance, and it can be a good option for earthquake-resistant constructions.

Effect of bolted splice within the plastic hinge zone on beam-to-column connection behavior

  • Vatansever, Cuneyt;Kutsal, Kutay
    • Steel and Composite Structures
    • /
    • v.28 no.6
    • /
    • pp.767-778
    • /
    • 2018
  • The purpose of this study is to investigate how a fully restrained bolted beam splice affects the connection behavior as a column-tree connection in steel special moment frames under cyclic loading when located within the plastic hinge zone. The impacts of this attachment in protected zone are observed by using nonlinear finite element analyses. This type of splice connection is designed as slip-critical connection and thereby, the possible effects of slippage of the bolts due to a possible loss of pretension in the bolts are also investigated. The 3D models with solid elements that have been developed includes three types of connections which are the connection having fully restrained beam splice located in the plastic hinge location, the connection having fully restrained beam splice located out of the plastic hinge and the connection without beam splice. All connection models satisfied the requirement for the special moment frame connections providing sufficient flexural resistance, determined at column face stated in AISC 341-16. In the connection model having fully restrained beam splice located in the plastic hinge, due to the pretension loss in the bolts, the friction force on the contact surfaces is exceeded, resulting in a relative slip. The reduction in the energy dissipation capacity of the connection is observed to be insignificant. The possibility of the crack occurrence around the bolt holes closest to the column face is found to be higher for the splice connection within the protected zone.

Nonlinear behavior of connections in RCS frames with bracing and steel plate shear wall

  • Ghods, Saeedeh;Kheyroddin, Ali;Nazeryan, Meissam;Mirtaheri, Seyed Masoud;Gholhaki, Majid
    • Steel and Composite Structures
    • /
    • v.22 no.4
    • /
    • pp.915-935
    • /
    • 2016
  • Steel systems composed of Reinforced Concrete column to Steel beam connection (RCS) have been raised as a structural system in the past few years. The optimized combination of steel-concrete structural elements has the advantages of both systems. Through beam and through column connections are two main categories in RCS systems. This study includes finite-element analyses of mentioned connection to investigate the seismic performance of RCS connections. The finite element model using ABAQUS software has been verified with experimental results of a through beam type connection tested in Taiwan in 2005. According to verified finite element model a parametric study has been carried out on five RCS frames with different types of lateral restraint system. The main objective of this study is to investigate the forming of plastic hinges, distribution of stresses, ductility and stiffness of these models. The results of current research showed good performance of composite systems including concrete column-steel beam in combination with steel shear wall and bracing system, are very desirable. The results show that the linear stiffness of models with X bracing and steel shear wall increase remarkably and their ultimate strength increase about three times rather than other RCS frames.

Composite action in connection regions of concrete-filled steel tube columns

  • Johansson, Mathias
    • Steel and Composite Structures
    • /
    • v.3 no.1
    • /
    • pp.47-64
    • /
    • 2003
  • In a nonlinear finite element study on the mechanical behavior of simple beam connections to continuous concrete-filled steel tube columns, two principally different connection types were analyzed: one with plates attached to the outside of the tube wall, relying on shear transfer, and one with an extended plate inserted through the steel section to ensure bearing on the concrete core. The load was applied partly at the connection within the column length and partly at the top, representing the load from upper stories of a multistory building. The primary focus was on the increased demand for load transfer to ensure composite action when concrete with higher compressive strength is used. The results obtained from the analyses showed that the design bond strength derived from push tests is very conservative, mainly due to the high frictional shear resistance offered by pinching and contraction effects caused by connection rotation. However, with higher concrete strength the demand for load transfer increases, and is hard to fulfill for higher loads when connections are attached only to the steel section. Instead, the connection should penetrate into the concrete core to distribute load to the concrete by direct bearing.

Seismic Performance Evaluation According to Rotation Capacity of Connections for Intermediate Steel Moment Frames - I. Performance Evaluation (접합부 회전성능에 따른 중간 철골 모멘트 골조의 내진 성능 평가 - I 성능평가)

  • Moon, Ki Hoon;Han, Sang Whan;Ha, Seung Jin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.95-103
    • /
    • 2014
  • The current AISC341-10 standard specifiesa value of 0.02 radian for the minimum rotation capacity of connections for the intermediate steel moment frame system. However, despite of the advances realized in the domains of performance evaluation method and analysis method, research onthe minimum rotation capacity of the intermediate steel moment frame systemsatisfying the seismic performance has not been conducted in detail. In this study, the intermediate moment frame systemisdesigned with respect to current standards and the seismic performance in accordance with the rotational capacity of connections is evaluated using the seismic performance evaluation method presented in FEMA-P695. The minimum rotation capacity of intermediate steel moment frames required to satisfy seismic performance as well as the major design values affecting the seismic performance of moment frame areestimated. To that goal, the design parameters are selected and various target frames are designed. The analysis models of the main nonlinear elements are also developed for evaluating seismic performance. The resultsshow that the 20-story structure doesnot meet the seismic performance even if it satisfies the rotation capacity of 0.02 radian.