• Title/Summary/Keyword: nondestructive thickness measurement

Search Result 74, Processing Time 0.02 seconds

A Study on the Modeling of Electromagnetic Wave Propagation for the Detection of a Delamination in Concrete Specimens (콘크리트 내의 공동탐사를 위한 전자기파 모델링)

  • 조윤범;임홍철
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.04b
    • /
    • pp.119-124
    • /
    • 2000
  • The radar method is becoming one of the major nondestructive testing (NDT) techniques for concrete structures. Numerical modeling of electromagnetic wave is needed to analyze radar measurement results and to study the influence of measurement parameters on the radar measurements. Finite difference-time domain (FD-TD) method is used to simulate electromagnetic wave propagation through concrete specimens. Three concrete specimens with a 25 mm delamination embedded at 25 mm, 50 mm, and 75mm depth are modeled in 3-dimension. Also, thickness change of delamination and permittivity change are modeled.

  • PDF

초음파 Spectroscopy에 의한 박막두께 측정

  • 박익근;한응교;최만용;한두교
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.190-199
    • /
    • 1992
  • Ultrasonic Spectroscopy technique, covering a wide frequency range, is one of the powerful Nondestructive Evaluation method for detection of microdefects and thickness measurement of thin film below the linit of ultrasonic distance resolution in various types of masterials and composites, provides a useful information that connot be obtained by a conventional measuring system using a single frequency. Results of computer simulation of multiple reflection wave were applied for particular cases : measurements of thickness and Ultrasonic wave velocities propagating normal to the surface in Acryle thin films can be evaluted by using the interference phenomenon, even dimensions of interest are smaller than the ultrasonic wavelength. The repeatability of the thickness measurement in 0.28 mm thin film was 10$\^$-3/.

Parametric study on multichannel analysis of surface waves-based nondestructive debonding detection for steel-concrete composite structures

  • Hongbing Chen;Shiyu Gan;Yuanyuan Li;Jiajin Zeng;Xin Nie
    • Steel and Composite Structures
    • /
    • v.50 no.1
    • /
    • pp.89-105
    • /
    • 2024
  • Multichannel analysis of surface waves (MASW) method has exhibited broad application prospects in the nondestructive detection of interfacial debonding in steel-concrete composite structures (SCCS). However, due to the structural diversity of SCCS and the high stealthiness of interfacial debonding defects, the feasibility of MASW method needs to be investigated in depth. In this study, synthetic parametric study on MASW nondestructive debonding detection for SCCSs is performed. The aim is to quantitatively analyze influential factors with respect to structural composition of SCCS and MASW measurement mode. First, stress wave composition and propagation process in SCCS are studied utilizing 2D numerical simulation. For structural composition in SCCS, the thickness variation of steel plate, concrete core, and debonding defects are discussed. To determine the most appropriate sensor arrangement for MASW measurement, the effects of spacing and number of observation points, along with distances between excitation points, nearest boundary, as well as the first observation point, are analyzed individually. The influence of signal type and frequency of transient excitation on dispersion figures from forwarding analysis is studied to determine the most suitable excitation signal. The findings from this study can provide important theoretical guidance for MASW-based interfacial debonding detection for SCCS. Furthermore, they can be instrumental in optimizing both the sensor layout design and signal choice for experimental validation.

Measurement of Thickness Distribution of $Si_3N_4$ Membrane Using Phase-Shifting Interferometer (위상이동 간섭계를 이용한 $Si_3N_4$ 박막의 두께 분포 측정)

  • Lee, Jung-Hyun;Jeong, Seung-Jun;Kang, Jeon-Woong;Jeon, Yun-Seong;Hong, Chung-Ki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.2
    • /
    • pp.67-73
    • /
    • 2005
  • The thickness of a Si3N4 thin film with a 100m nominal thickness was measured by use of a Mach-Zehnder interferometer. The map of the phase-delay through the thin film was obtained by an interframe intensity-correlation-matrix method that could elliminate phase-shifting errors. After the spatial phase-shifting errors were treated with a least-squares method, the reference to surface of the phase map was estimated. The overall accuracy of the method was found to be 5nm.

Study on the Qualitative Defects Detection in Composites by Optical Infrared Thermography (적외선 열화상 기술을 이용한 복합재료의 결함 검출 정량화 연구)

  • Park, Hee-Sang;Choi, Man-Yong;Park, Jeong-Hak;Kim, Won-Tae;Choi, Won-Jong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.2
    • /
    • pp.150-156
    • /
    • 2011
  • In this paper, infrared thermography measurement technique has been used to develop standard measurement technique for nondestructive testing of composite materials which is widely used in aerospace industries. To increase the defect detection rate, the related experiment used the lock-in IR-thermographiy method. Therefore it is of considerable interest in the field of non-destructive testing for fast discontinuity detection by using ultrasonic lock-in infrared thermography. The result also shows that as the investigation period of light source is lengthened according to the thickness of specimen, the possibility of detecting defects gets higher as well. However, the reason why the result values were not favorable when less than 50 mHz of light source was provided is because it was difficult to detect defects as the defect parts became a state of thermal equilibrium in general when thermal diffusivity affects the entire materials.

Thickness Measurement of Ni Thin Film Using Dispersion Characteristics of a Surface Acoustic Wave (표면파의 분산 특성을 이용한 Ni 박막의 두께 측정)

  • Park, Tae-Sung;Kwak, Dong-Ryul;Park, Ik-Keun;Kim, Miso;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.2
    • /
    • pp.171-175
    • /
    • 2014
  • In this study, we suggest a method to measure the thickness of thin films nondestructively using the dispersion characteristics of a surface acoustic wave propagating along the thin film surface. To measure the thickness of thin films, we deposited thin films with different thicknesses on a Si (100) wafer substrate by controlling the deposit time using the E-beam evaporation method. The thickness of the thin films was measured using a scanning electron microscope. Subsequently, the surface wave velocity of the thin films with different thicknesses was measured using the V(z) curve method of scanning acoustic microscopy. The correlation between the measured thickness and surface acoustic wave velocity was verified. The wave velocity of the film decreased as the film thickness increased. Therefore, thin film thickness can be determined by measuring the dispersion characteristics of the surface acoustic wave velocity.

A Study on Real-Time Corrosion Thickness Measurement Technique of Insulated Pipeline (보온재 부착 파이프라인의 부식두께 측정에 관한 연구)

  • Jang, Ji-Hun;Jo, Gyeong-Sik;Lee, Jong-O;Kim, Gi-Dong
    • 연구논문집
    • /
    • s.31
    • /
    • pp.135-147
    • /
    • 2001
  • The wall-thickness of insulated pipelines can be easily evaluated by measuring the gamma-ray transmission intensity because this intensity is inversely proportional to the thickness of insulated pipeline. The main purpose of this study is to develop the nondestructive and filmless on-line inspection system of corrosion by measuring the wall thickness of insulated pipeline. The inspection system is constructed with radioisotope, 64 channel photo diode array detector, crawler system and data taking and operating software. The traditional off-line radiographic method carried out by exposing film cassettes can be replaced by this cost-effective on-line digital imaging method and the application will be greatly expected especially in the chemical and petrochemical industries.

  • PDF

Analysis on Propagation Characteristics and Experimental Verification of $A_1$ Circumferential Waves in Nuclear Fuel Rods Coated with Oxide Layers (산화막 피복 원전 연료봉에서 $A_1$ 원주파의 전파 특성 해석과 실험적 검증)

  • Joo, Young-Sang;Ih, Jeong-Guon;Jung, Hyun-Kyu;Cheong, Yong-Moo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.189-199
    • /
    • 1999
  • The resonance scattering of acoustic waves from the cylindrical shells of nuclear fuel rods coated with oxide layers has been theoretically modeled and numerically analyzed for the propagation characteristics of the circumferential waves. The normal mode solutions of the scattering pressure of the coated shells have been obtained. The pure resonance components have been isolated using the newly proposed inherent background coefficients. The propagation characteristics of resonant circumferential waves for the shells coated with oxide layers are affected by the presence and the thickness of an oxide layer. The characteristics have been experimentally confirmed through the method of isolation and identification of resonances. The change of the phase velocity of the $A_1$ circumferential wave mode for the coated shell is negligible at the specified partial waves in spite of the presence of the oxide layer and the increase in coating thickness. Utilizing the invariability characteristics of the phase velocity of the $A_1$ mode, the oxide layer thickness of the coated shells can be estimated. A new nondestructive technique for the relative measurement of the coating thickness of coated shells has been proposed.

  • PDF

Defect Depth Measurement of Straight Pipe Specimen Using Shearography (전단간섭계를 이용한 직관시험편의 결함 깊이 측정)

  • Chang, Ho-Seob;Kim, Kyung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.170-176
    • /
    • 2012
  • In the nuclear industry, wall thinning defect of straight pipe occur the enormous loss in life evaluation and safety evaluation. To use non-destructive technique, we measure deformation, vibration, defect evaluation. But, this techniques are a weak that is the measurement of the wide area is difficult and the time is caught long. In the secondary side of nuclear power plants mostly used steel pipe, artificiality wall thinning defect make in the side and different thickness make to the each other, wall thinning defect part of deformation measure by using shearography. In addition, optical measurement through deformation, vibration, defect evaluation evaluate pipe and thickness defects of pressure vessel is to evaluate quantitatively. By shearography interferometry to measure the pipe's internal wall thinning defect and the variation of pressure use the proposed technique, the quantitative defect is to evaluate the thickness of the surplus. The amount of deformation use thickness of surplus prediction of the actual thickness defect and approximately 7 percent error by ensure reliability. According to pressure the amount of deformation and the thickness of the surplus through DB construction, nuclear power plant pipe use wall thinning part soundness evaluation. In this study, pressure vessel of thickness defect measure proposed nuclear pipe of wall thinning defect prediction and integrity assessment technology development. As a basic research defected theory and experiment, pressure vessel of advanced stability and soundness and maintainability is expected to contribute foundation establishment.

Thickness Measurement of Pipe Using Tangential Radiography (Tangential Radiography를 이용한 배관의 두께 평가법)

  • Lee, S.S.;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.205-210
    • /
    • 1998
  • 이미 오래전부터 국내외에서 석유화학공장 등의 보온 배관에서 보온재를 벗기지 않고 배관의 부식 손상 및 잔존두께를 평가하는데 방사선투과시험법을 적용해 오고 있다. 그러나 배관 용접부의 결함 탐상에 관한 방사선투과법에 대한 국제 및 국내 코드는 이미 마련되어 있지만 배관의 두께와 내부에 존재하는 부착물(deposit) 등의 두께를 측정하는 것에 관련한 국제 및 국내 코드는 미비되어 시험 절차 및 시험 결과에 대한 시비가 근본적으로 존재할 수 밖에 없을 뿐만 아니라 표준화된 시험 기술의 미비로 현장에서 많은 시행착오를 동반하였다. 그러나 최근 이 시험법에 대한 관련 원안(protocol)을 확정하기 위해 각국에서 개별적으로 수행되었던 기존의 연구 결과들이 취합되고 있으며 부족한 부분들에 대한 연구가 국제 공동 연구 형식으로 이뤄지고 있다. 따라서 본 연구에서는 tangential radiography를 적용하여 보온된 배관의 잔존 두께를 평가할 수 있는 시험 방법을 제시하고자 하였다.

  • PDF