• 제목/요약/키워드: non-metal

검색결과 1,684건 처리시간 0.034초

초음파법에 의한 $Al_2O_3/AC8A$ 복합재료의 특성평가 (Non-Destructive Evaluation of $Al_2O_3/AC8A$ Composite by Ultrasonic Measurement)

  • 박영철;이규창;이준현
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.816-825
    • /
    • 1994
  • The purpose of this study is to develop the non-destructive material evaluation method of aluminum alloy base metal matrix composite(MMC) by ultrasonics. Five aluminum base MMC specimens were fabricated in which the fractional ratios of fiber were changed from 0% to 31%. Relations among acoustic properties, microstructural features and elastic constant were compared. The ultrasonic velocity method was useful for nondestructive elastic constant measurement of composite materials, since the method had as same accuracy as conventional strain measurement method. Furthermore, velocity, attenuation and backscattering behaviors for each specimen also related to fractional ratio of fiber and these relations could utilize ultrasonic non-destructive evaluation of fiber structure in MMC.

상이(霜異)한 Ceramometal System에 있어서 Nickel-Chromium합금과 도재(陶材)와의 결합강도(結合强度)에 관(關)한 비교실험연구(比較實驗硏究) (A Study of Bond Strength of Nickel-Chromium Alloys with Porcelain in Ceramometal System)

  • 김치영
    • 대한치과기공학회지
    • /
    • 제7권1호
    • /
    • pp.19-25
    • /
    • 1985
  • In oder to compare and measure bond strength of ceramometal system with use of ceramco porcelain powder including SnO2 and uni metal, Rexillium III, Vera Bond as non precious alloys manufactured for porecelain-metal restorations. Total 24 test sample were constructed. All Test sample were measured with a Mitutoyo micrometer graduated to 0.01mm. It is as follows measured of thickness 3.3mm(metal : 1.1mm, porcelain: 2.2mm), width 12mm, length 30mm(porcelain 12mm x 12mm), Compared maximum bending stress test. The results obtained were as follows: 1. Bond strength of each metal with ceramco porcelain powder showed statistical significance.(P<0.05) 2. Vera Bond and uni metal, uni metal and Rexillium III revealed no statistical Significance.(P>0.05) Vera Bond and Rexillium III showed statistical significance.(P<0.05) 3. The order of maximum bending stress was Rexillium III, uni metal, vera Bond. The order of bond strength ratio making bending stress was Vera bond, uni metal, Rexillium III.

  • PDF

아크 금속 용사 표면 처리 방법에 따른 Zn-Al 금속 용사 피막의 물리적 특성 평가 (Evaluation of physical properties of Zn-Al metal coating according to arc metal spray surface treatment method)

  • 장종민;김영관;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.89-90
    • /
    • 2022
  • Arc metal spraying is a widely used method for improving the performance of construction structures such as corrosion resistance and electromagnetic wave shielding. However, when arc metal spraying is applied to a concrete structure, adhesion performance may deteriorate. Therefore, the effect of each surface treatment method on the physical properties between the arc metal spray coating and concrete was reviewed by evaluating the deposition efficiency and adhesion performance according to the arc metal spray surface treatment method (surface reinforcing agent, roughening agent, and sealing agent). As a result, it is suggested as an optimal surface treatment condition to induce non-interface failure by using a roughening agent and to improve the properties of concrete and metal coatings by applying a surface reinforcing agent and sealing agent.

  • PDF

십전대보탕을 투여한 흰쥐의 중요장기중 금속농도변화에 대한 연구 (Effect of SipJeonDaeBo-Decoction on Target Organ Metal Level in Rats)

  • 윤성욱;이선동
    • 대한예방한의학회지
    • /
    • 제4권1호
    • /
    • pp.51-69
    • /
    • 2000
  • This dissertation was to research how some metal level within SipJeonDaeBo - Decoction, one of oriental prescriptions, influence Sprague-Dawley animals. 1. Under the experiment with drinking waters there was no metal ${\sim}0.65\;mg/L$ detected. A metal with feed found 0.001-376.983mg/kg. 2. In the mice's kidney, brain, bones used experiment, As searched 0.474 mg/kg, 0.486 mg/kg, 0.314 mg/kg 0.834 mg/kg respectively ; Cd 0.060 mg/kg, 0.045 mg/kg, 0.030 mg/kg, 0.353 mg/kg, ; Co 0.105 mg/kg, 0.063 mg/kg, 0.030 mg/kg, 0.399 mg/kg, ; Cr 0.292 mg/kg, 0.304 mg/kg, 0.234 mg/kg, 0.962 mg/kg, ; Cu 4.201 mg/kg, 3.759 mg/kg, 1.923 mg/kg, 0.484 mg/kg, ; Fe 57.535 mg/kg, 150.571 mg/kg, 17.178 mg/kg, 281.506 mg/kg, ; no Hg, Mn 0.612 mg/kg, 2.968 mg/kg, 0.528 mg/kg, 4.205 mg/kg, ; Ni 0.094 mg/kg, 0.072 mg/kg, 0.078 mg/kg, 27.714 mg/kg, ; Pb 0.269 mg/kg, 0.293 mg/kg, 0.283 mg/kg, 43.142 mg/kg ; Zn 4.149 mg/kg, 21.861 mg/kg, 8.088 mg/kg, 226.283 mg/kg respectively. 3. In level of hazardous metal within idney control group searched 0.194 {\pm}\; 0.052 mg/kg, experimental I g개up $0.189{\pm}0.036\;mg/kg$, experimental I group $0.264 {\pm}{\pm}\;0.179\;mg/kg$. In level of non hazardous metal control group searched $15.917{\pm}5.575\;mg/kg$, experiment I group $17.064{\pm}2.246\;mg/kg$, experiment II group $16.892{\pm}3.586\;mg/kg$. Besides in total level of metal control g.cup detected $6.484{\pm}2.258\;mg/kg$, experiment I group $6.940{\pm}0.914\;mg/kg$, experiment II group $6.915{\pm} 1.508\;mg/kg$ There all was no statistical significance. 4. In level of hazardous metal within the liver control group searched $0.187{\pm}0.048\;mg/kg$, experiment I g개up $0.168[\pm}0.079\;mg/kg$, experiment II group $0.277{\pm}0.159\;mg/kg$. In level of non hazardous heavy metal control group detected $44.925{\pm}18.468\;mg/kg$, experiment I group $39.917{\pm}12.772\;mg/kg$, experiment II group $49.525{\pm}33.484\;mg/kg$. Besides in total concentration control group searched $18.082{\pm}7.395\;mg/kg$, experiment I group $16.068{\pm}5.128\;mg/kg$, experiment II group $19.977{\pm}13.443\;mg/kg$. There was no statistical significance but hazardous metal gets more level in the experilnent group than in the control group. 5. In level of hazardous metal within brain control group searched $0.145{\pm}0.056\;mg/kg$, experiment I group $$0.167{\pm}0.030\;mg/kg, erperiment II group $0.172{\pm}0.123\;mg/kg$. In level of non hazardous heavy metal control group detected $6.488{\pm}0.965\;mg/kg$, experiment I group $7.290{\pm}0.588\;mg/kg$, experiment II group $7.010{\pm}1.627\;mg/kg$. Besides in total concentration control group searched $2.683{\pm}7.395\;mg/kg$, experiment I group $3.017{\pm}0.238\;mg/kg$, experiment II group $2.908 {\pm} 0.711\;mg/kg$. Therefore there was no statistical significance. 6. In level of hazardous metal within bone control group searched $8.172{\pm}5.195 \;mg/kg$, experiment I group $9.128{\pm}4.143\;mg/kg$, experiment II group $9.401{\pm}6.924\;mg/kg$. There is statistical significance(p<0.05). In level of non hazardous metal control group detected $94.065{\pm}36.035\;mg/kg$, experiment I group $147.563 {\pm}79.939\;mg/kg$, experiment II group $142.730{\pm}77.374\;mg/kg$. Besides in total level control group searched $48.530{\pm}16.523\;mg/kg$, experiment I group $64.502{\pm}31.078\;mg/kg$, experiment II group $62.733 {\pm}34.641\;mg/kg$. Therefore there was no statistical significance. 7 In the correlative research as to how each metal influences to ingestion Cd and Co searched 0.954 and Pb and Ni -0.0884 from kidney. Co and Cd was 0.995 and Zn and As -0.190 from liver. Co and Cd were 0.995 and Zn and Cu -0.393 from brain. Co and Cd were 0.998 and Zn and Mn -0.206 from bones

  • PDF

PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석 (A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests)

  • 윤선희;김양중;강영직;박수영;김호신;류형기
    • 핵의학기술
    • /
    • 제19권1호
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

피라미드형 내부구조재를 가지는 중공형 접합판재의 성형특성에 관한 연구 (A Study on the Forming Characteristic of Inner Pyramid Structure Bonded Sheet Metal)

  • 김지용;길해영;조기철;김종호;정완진
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.295-299
    • /
    • 2006
  • The inner-structure bonded(ISB) sheet metal is defined as a composite sheet metal which has middle layer of truss-structure between two skin sheets. The characteristics such as ultra-light weight, high rigidity, high strength, etc are required especially for automobile parts. The characteristic of ISB sheet metal depends on inner-structure pattern or method of bonding. Pyramid type of crimped expanded metal is used for inner-structure and both of resistance welding and adhesive bonding are applied to make a specimen. As a result of compression test, it is appeared that forming limit is 10% reduction in thickness under a load of 8kgf per unit element(one inner-structure). In case of uniaxial tensile test the non-uniform surface integrity rather than the buckling of inner-structure happened at a load of 450kgf, which indicates elongation of 7.2% and thickness reduction of 13%. The eye-inspection method was applied to examine the defects occurring on the specimen during stretch forming. In case of biaxial stretch forming only the non-uniform deformation on the surface of a skin sheet could be observed. The forming limit in stretching of ISB sheet metal with the hemi-spherical punch of 150mm in diameter was 3mm in forming depth and 5% reduction in thickness.

  • PDF

금속 입자 크기가 토양 미생물 군집과 메밀에 미치는 영향 (Effects of Size of Metal Particles on Soil Microbial Community and Buck Wheat)

  • 김성현;김정은;곽영지;김연지;이인숙
    • 한국환경과학회지
    • /
    • 제20권4호
    • /
    • pp.457-463
    • /
    • 2011
  • This study was carried out to compare the toxicity of nano and micrometer particles with Cu and Zn on soil microbial community and metal uptake of buck wheat. In microcosm system, soil was incubated for 14 days after soil aliquots were artificially contaminated with 1,000 mg/kg Cu, Zn nano and micro particles, respectively. After then, buck wheat was planted in incubating soils and non incubating soils. After 14 days, we compared bioaccumulation of metal, and microbial carbon substrate utilization patterns between incubating soils and non-incubating soils. The enrichment factor (EF) values of incubating samples were greater than non-incubating soils. Dehydrogenase activity had been inhibited by Cu and Zn nanoparticles in non-incubating soil, as well as it had been inhibited by Zn micro particles in incubating soils. Results of biolog test, it was not significant different between nano particles and micro particles. It cannot be generalized that nanoparticles of metal are always more toxic to soil microbial activity and diversity than micrometer-sized particles and the toxicity needs to be assessed on a case-by-case basis.

광산업의 B2B 공적 e-Marketplace 프레임워크 구축에 관한 연구 (A Public-oriented e-marketplace Framework for the Mining Industry)

  • 박기남
    • 한국산업정보학회논문지
    • /
    • 제11권5호
    • /
    • pp.53-61
    • /
    • 2006
  • 우리나라는 지하자원이 부족한 반면 가공무역과 수출을 경제성장의 주요한 동력으로 하기 때문에 항상 산업원자재의 수급에 신경을 곤두세울 수밖에 없다. 이러한 현실은 국내 외 산업원료광물의 조기확보와 효율적인 상거래를 지원하기 위한 기업 간 전자상거래의 중요성을 크게 부각시킬 수 있다. 우리나라는 세계적 정보통신 강국으로 간주되지만 산업별 정보화 수준의 편차가 매우 크며 비금속 산업원료 광물 분야의 경우 정보화수준이 매우 낮다. 비금속 산업원료광불 분야는 아직까지 시장의 효율성이나 다양성 그리고 원가절감을 위한 노력이 매우 부족하며 원료광물의 대부분을 수입하면서 아직까지도 시장의 효율성을 이용하지 못하여 낭비되는 외화가 매우 많은 것으로 나타났다. 따라서 본 연구는 정보기술의 활용수준이 매우 낮은 비금속 광산업분야에 B2B 공적 e-Marketplace 를 구축하여 국내에서 생산이 가능하고 품질이 뛰어나며, 부가가치가 높은 광물들은 국내의 수요처 발굴을 통해 거래활성화를 도모하고 국내에서 생산되지 않거나 품질이 낮아 부가가치를 기대할 수 없는 광물들은 시장정보와 다양한 수입처 정보를 활용하여 효율적 시장거래를 지원할 수 있는 e-Marketplace 프레임워크를 제공하는 것을 목적으로 한다.

  • PDF

충남 금산 폐탄광지역의 토양 및 식물체내 중금속 오염 (Heavy Metal Pollution in Soil and Vegetation near the Closed Daeseong Coal Mine in Keumsan, Chungnam)

  • 민일식;송석환;김명희
    • 한국토양환경학회지
    • /
    • 제3권2호
    • /
    • pp.41-51
    • /
    • 1998
  • 충남 금산의 대성폐탄광 주변 토양 및 식생에 대한 중금속의 오염도를 파악하기 위해, 탄질물을 함유하는 오염지역과 그렇지 않은 비오염지지역으로 구분하여 양 지역에서 토양과 식물체(참억새와 리기 다소나무에 대해 Co, Cr, Fe, Ni, Mo, Sc및 Zn등 7개 중금속의 농도를 조사하였다. 토양내 중금속 농도는 Cr, Mo, Ni, Fe의 경우 탄질물을 많이 함유하는 오염지역에서 높았으며, Co, Sc, Zn은 비오염지역의 토양에 더 많이 함유되어 있었다 오염지에서 생육하는 참억새 및 리기다소나무의 Co, Cr, Sc, Fe농도는 지상부 보다 뿌리내의 농도가 더 높았으며, 비오염지에서 Ni및 Mo은 반대의 경향을 나타내었다. 참억새의 경우 지상부는 Cr을 제외한 Co, Mo, Ni, Sc, Zn, Fe원소 모두 비오염지에서 농도가 높았고, 뿌리는 Zn을 제외한 모든 원소가 오염지에서 높게 나타났다. 리기다소나무의 경우에 지상부는 Cr과 Fe만 비오염지에서 높았고, 뿌리는 모든 원소가 오염지에서 높았다. 오염지 및 비오염지의 식생내 중금속 농도는 Zn을 제외하고 전원소가 토양의 농도 보다 낮았다. 토양과 식물체내 중금속 농도의 원소별 변화는 리기다소나무 보다 참억새가 토양의 함량치에 가까웠으며, 탄질물을 많이 함유한지역일수록 참억새 보다 리기다소나무의 중금속 흡수가 더 높았다.

  • PDF

As-Te-Si-Ge 비정질박막 스위칭 소자의 전극영향에 관한 연구 (A Study on the Electrode Effect of As-Te-Si-Ge Non-Crystalline Thin film Switching Devices)

  • 박창엽;정홍배
    • 전기의세계
    • /
    • 제25권1호
    • /
    • pp.104-107
    • /
    • 1976
  • The switching characteristics of Non-crystalline As-Te-Si-Ge thin film device using Ag, In and Al metal for electrode, has been investigated. Threshold voltage and holding current of each sandwich type device varied due the to formation of the potential barrier in between non crystalline solid and electrode interface.

  • PDF