• Title/Summary/Keyword: non-local condition

Search Result 181, Processing Time 0.026 seconds

Prediction of flow field in an axial compressor with a non-uniform tip clearance at the design and off-design conditions (설계점 및 탈설계점에서 비균일 익단 간극을 가지는 축류 압축기의 유동장 예측)

  • Kang, Young-Seok;Park, Tae-Choon;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.6
    • /
    • pp.46-53
    • /
    • 2008
  • Flow structures in an axial compressor with a non-uniform tip clearance were predicted by solving a simple prediction method. For more reliable prediction at the off-design condition, off-design flow characteristics such as loss and flow blockage were incorporated in the model. The predicted results showed that flow field near the design condition is largely dependent on the local tip clearance effect. However overall flow field characteristics are totally reversed at off-design condition, especially at the high flow coefficient. The tip clearance effect decreases, while the local loss and flow blockage make a complicated effect on the compressor flow field. The resultant fluid induced Alford's force has a negative value near the design condition and it reverses its sign as the flow coefficient increases and shows a very steep increase as the flow coefficient increases.

Design of a Local Ventilation System in the Non-Standard Air Condition using the Spreadsheet Model (스프레드시트 모델을 이용한 비표준 공기상태에서의 국소환기시스템의 설계)

  • 조석호
    • Journal of Environmental Science International
    • /
    • v.6 no.6
    • /
    • pp.645-658
    • /
    • 1997
  • A study on ventilation design using the spreadsheet model is carried out to propose means of available design. A sample of complex ventilation system In the non-standard condition Is used to illustrate thins spreadsheet model. In developing the spreadsheet model, this study has attempted to it general by using computional equations and design parameters that can be readily applied to any spreadsheet software. Also, most design data is contained in the spreadsheet template. This template provides the same design information as the ACGIH worksheet, and operates Quickly and emclenuy, and is fiexible enough to use under different conditions. This spreadsheet model allows the ventilation engineer to design quickly and accurately the ventilation system, without spending too much effort In the design process. By storing on computer and diskette, the design data computed finally can be used as a permanent record of specific ventilation system, and because of finally to be able to design over and over again while making only slight changes to the Input data, the spreadsheet model is used availably to accomplish the design optimazation by redesign and troubleshooting by review from field measurements. Also, the spreadsheet model is available for designing ventilation system under different condition or evaluating existing system or design drawing, because changes In the layout or formulae can be readily made to fit the needs of the designer.

  • PDF

ON COLUMN INVARIANT AND INDEX OF COHEN-MACAULAY LOCAL RINGS

  • Koh, Jee;Lee, Ki-Suk
    • Journal of the Korean Mathematical Society
    • /
    • v.43 no.4
    • /
    • pp.871-883
    • /
    • 2006
  • We show that the Auslander index is the same as the column invariant over Gorenstein local rings. We also show that Ding's conjecture ([13]) holds for an isolated non-Gorenstein ring A satisfying a certain condition which seems to be weaker than the condition that the associated graded ring of A is Cohen-Macaulay.

A Method for Critical Heat Flux Prediction in Vertical Round Tubes with Axially Non-uniform Heat Flux Profile

  • Shim, Jae-Woo
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.13-21
    • /
    • 2008
  • In this study a method to predict CHF(Critical heat flux) in vertical round tubes with axially non-uniform cosine heat flux distribution for water was examined. For this purpose a local condition hypothesis based CHF prediction correlation for uniform heat flux in vertical round tubes for water was developed from 9,366 CHF data points. The local correlation consisted of 4 local condition variables: the system pressure(P), tube diameter(D), mass flux of water(G), and 'true mass quality' of vapor($X_t$). The CHF data points used were collected from 13 different published sources having the following operation ranges: 1.01 ${\leq}$ P (pressure) ${\leq}$ 206.79 bar, 9.92${\leq}$ G (mass flux) ${\leq}$ 18,619.39 $kg/m^2s$, 0.00102 ${\leq}$ D(diameter) ${\leq}$ 0.04468 m, 0.0254${\leq}$ L (length) ${\leq}$ 4.966 m, 0.11 ${\leq}$ qc (CHF) ${\leq}$ 21.41 $MVW/m^2$, and -0.87 ${\leq}X_c$ (exit qualities) ${\leq}$ 1.58. The result of this work showed that a uniform CHF correlation can be easily extended to predict CHF in axially non-uniform heat flux heater. In addition, the location of the CHF in axially non-uniform tube can also be determined. The local uniform correlation predicted CHF in tubes with axially cosine heat flux profile within the root mean square error of 12.42% and average error of 1.06% for 297 CHF data points collected from 5 different published sources.

The Perfectly Matched Layer applied to the Split-Step Pade PE Solver in an Ocean Waveguide

  • Lee, Keun-Hwa;Seong, Woo-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.3E
    • /
    • pp.131-136
    • /
    • 2006
  • The PML developed for the radio wave propagation is a powerful numerical domain truncation technique. We perform an analytic study on the reflection from the PML inserted in the ocean bottom. In the ocean bottom, we show the PML to have the improved performance but simultaneously the degeneration below the critical angle of the fast ocean bottom. The degeneration of the PML can be simply relaxed by stretching the thickness of the PML or putting the attenuation coefficient to the ocean bottom. As a better solution, we propose the improved truncation technique based on the PML and the non-local boundary condition. Finally, we apply the PML to the acoustic wave propagation using split-step Pade PE solver. For the problems of the ocean waveguide, the numerical efficiency of the PML is examined and the usefulness of the PML is confirmed.

Recommendation for the modelling of Donnell shell: The relationship between non-local parameter and frequency

  • Mohamed A. Khadimallah;Muzamal Hussain;Elimam Ali;Sehar Asghar;Abdelouhed Tounsi
    • Computers and Concrete
    • /
    • v.32 no.2
    • /
    • pp.165-172
    • /
    • 2023
  • The vibration analysis of armchair, zigzag and chiral double-walled carbon nanotubes has been developed by inserting the nonlocal theory of elasticity into thin shell theory. First Donnell shell theory is employed while exercising wave propagation approach. Scale effects are realized by using different values of nonlocal parameters under certain boundary conditions. The natural frequencies have been investigated and displayed for various non-local parameters. It is noticed that on increasing nonlocal parameter, the frequency curve tends to decrease. The frequency estimates of clamped-free boundary condition are less than those of clamped-clamped and simply supported computations. The frequency comparisons are presented for armchair, zigzag and chiral nanotubes. The software MATLAB is used to extract the frequencies of double walled carbon nanotubes.

FUZZY DIFFERENTIAL EQUATIONS WITH NONLOCAL CONDITION

  • JEONG JAE UG
    • Journal of applied mathematics & informatics
    • /
    • v.17 no.1_2_3
    • /
    • pp.509-517
    • /
    • 2005
  • We shall prove the existence and uniqueness theorem of a solution to the non local fuzzy differential equation using the contraction mapping principle.

Estimation of non-working days due to weather condition using fuzzy numbers (퍼지값을 이용한 기후요소 작업불능일 산정에 관한 연구)

  • Kim, Joo-Heon;Choi, Hee-Bok;Shin, Yoon-Seok;Cho, Hun-Hee;Kang, Kyung-In
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.349-352
    • /
    • 2008
  • Weather condition is the uncontrolled factor to influence the project duration. Determining non-working days due to it incorrectly leads to often change the project duration and increase the total cost as well as causing the dispute among stakeholders. When making decision of non-working days, it is important to consider the expert's experience according to the characteristic of the site and local area. Therefore this paper presented the method to estimate non-working days due to wether condition by using fuzzy numbers reflecting expert's subjective experience.

  • PDF

Analytic Error Caused by the Inconsistency of the Approximation Order between the Non Local Boundary Condition and the Parabolic Governing Equation (포물선 지배 방정식과 비국소적 경계조건의 근사 차수 불일치에 의한 해석적 오차)

  • Lee Keun-Hwa;Seong Woo-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.5
    • /
    • pp.229-238
    • /
    • 2006
  • This paper shows the analytic error caused by the inconsistency of the approximation order between the non local boundary condition (NLBC) and the parabolic governing equation. To obtain the analytic error, we first transform the NLBC to the half space domain using plane wave analysis. Then, the analytic error is derived on the boundary between the true numerical domain and the half space domain equivalent to the NLBC. The derived analytic error is physically expressed as the artificial reflection. We examine the characteristic of the analytic error for the grazing angle, the approximation order of the PE or the NLBC. Our main contribution is to present the analytic method of error estimation and the application limit for the high order parabolic equation and the NLBC.

Using Freeze Frame and Visual Notifications in an Annotation Drawing Interface for Remote Collaboration

  • Kim, Seungwon;Billinghurst, Mark;Lee, Chilwoo;Lee, Gun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.12
    • /
    • pp.6034-6056
    • /
    • 2018
  • This paper describes two user studies in remote collaboration between two users with a video conferencing system where a remote user can draw annotations on the live video of the local user's workspace. In these two studies, the local user had the control of the view when sharing the first-person view, but our interfaces provided instant control of the shared view to the remote users. The first study investigates methods for assisting drawing annotations. The auto-freeze method, a novel solution for drawing annotations, is compared to a prior solution (manual freeze method) and a baseline (non-freeze) condition. Results show that both local and remote users preferred the auto-freeze method, which is easy to use and allows users to quickly draw annotations. The manual-freeze method supported precise drawing, but was less preferred because of the need for manual input. The second study explores visual notification for better local user awareness. We propose two designs: the red-box and both-freeze notifications, and compare these to the baseline, no notification condition. Users preferred the less obtrusive red-box notification that improved awareness of when annotations were made by remote users, and had a significantly lower level of interruption compared to the both-freeze condition.