• Title/Summary/Keyword: non-invasive method

Search Result 456, Processing Time 0.025 seconds

Implementation of Non-Invasive Cerebral Perfusion Platform (비침습적 대뇌관류 장치의 구현)

  • Kwon, Seong-tae;Lee, Jean;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.5
    • /
    • pp.1016-1026
    • /
    • 2017
  • Shipping Along with the aging of the total population, its importance is greater cause of stroke, which is one of the diseases are listed cerebral perfusion is about 80%,.ie that the flow of blood flowing to the brain is reduced as the cause. One of the most typical prophylaxis and treatment of these stroke is to enhance cerebral perfusion. There are several ways to increase cerebral blood flow are a therapy through drugs, through surgery and invasive NeuroFlo. NeuroFlo is to insert a catheter to which a balloon is attached into a patient's artery. However, since the method of enhancing conventional cerebral perfusion have been conducted mainly in invasive method, giving a burden to the patient, the problem of inducing a number of complications were noted. In this paper, an attempt to supplement the shortcomings of such invasive brain perfusion increase method, to provide a device to enhance the non-invasively brain perfusion.

Non-Invasive HbA1c Measurement Using Two-Wavelength Raman Scattering (2 파장 라만 산란을 이용한 비침습적 HbA1c 측정)

  • Yang, Jooran;Kim, Hyungpyo
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.305-310
    • /
    • 2019
  • The purpose of this study is to classify the concentration of HbA1c (glycosylated hemoglobin), which is an indicator in the management of accurate blood glucose level in diabetic patients, using a non-invasive optical property measurement method. To measure the optical properties of HbA1c, the optical source uses LEDs and laser diodes of 400 nm in the visible region and 1450 nm in the nearinfrared region using thermopile to detect the Raman scattering intensity. An HbA1c control solution was used. As a result, the optical properties of 5% (normal) and 9% (abnormal) HbA1c control solutions showed specificity in which the output values were reversed at 850 nm and 950 nm, respectively. This property was applied to distinguish between normal and abnormal values in diabetes. In addition, considering tissue penetration depths for non-invasive measurements, two wavelengths were determined to be effective in distinguishing the concentrations of HbA1c control solutions at 5%, 7%, and 9%.

Diagnosis of Helicobacter pylori Infection (헬리코박터 파일로리 감염 진단의 최신 지견)

  • Huh, Cheal Wung;Kim, Byung-Wook
    • The Korean Journal of Gastroenterology
    • /
    • v.72 no.5
    • /
    • pp.229-236
    • /
    • 2018
  • Accurate diagnosis of Helicobacter pylori (H. pylori) infection is mandatory for the effective management of many gastroduodenal diseases. Currently, various diagnostic methods are available for detecting these infections, and the choice of method should take into account the clinical condition, accessibility, advantage, disadvantage, as well as cost-effectiveness. The diagnostic methods are divided into invasive (endoscopic-based) and non-invasive methods. Non-invasive methods included urea breath test, stool antigen test, serology, and molecular methods. Invasive methods included endoscopic imaging, rapid urease test, histology, culture, and molecular methods. In this article, we provide a review of the currently available options and recent advances of various diagnostic methods.

Monitoring Ion Energy Distribution in Capacitively Coupled Plasmas Using Non-invasive Radio-Frequency Voltage Measurements

  • Choi, Myung-Sun;Lee, Seok-Hwan;Jang, Yunchang;Ryu, Sangwon;Kim, Gon-Ho
    • Applied Science and Convergence Technology
    • /
    • v.23 no.6
    • /
    • pp.357-365
    • /
    • 2014
  • A non-invasive method for ion energy distribution measurement at a RF biased surface is proposed for monitoring the property of ion bombardments in capacitively coupled plasma sources. To obtain the ion energy distribution, the measured electrode voltage is analyzed based on the circuit model which is developed with the linearized sheath capacitance on the assumption that the RF driven sheath behaves like a simple diode for a bias power whose frequency is much lower than the ion plasma frequency. The method is verified by comparing the ion energy distribution function obtained from the proposed model with the experimental result taken from the ion energy analyzer in a dual cathode capacitively coupled plasma source driven by a 100 MHz source power and a 400 kHz bias power.

A Non-Invasive Ultrasonic Urinary Bladder Internal Pressure Monitoring Technique: Its Theoretical Foundation and Feasibility Test (비침습적 초음파 방광 내압 측정 기술: 이론적 기초 및 실현 가능성 평가)

  • Choi, Min Joo;Kang, Gwan Suk;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.526-539
    • /
    • 2012
  • A new approach was proposed in this article, named, a non-invasive ultrasonic method to monitor the urinary bladder internal pressure which can resolve the shortcomings of the existing methods. The proposed method makes use of acoustic cavitation. It is based on a physical phenomenon that an extracorporeal high intensity focused ultrasonic pulse generates bubbles inside the urinary bladder and the dynamic properties of the bubbles are related to the urinary bladder internal pressure. The article presents the theoretical foundation for the proposed technique and verifies its feasibility with preliminary experimental data. The suggested ultrasonic urinary bladder internal pressure monitoring method is non-invasive and can be used any time regardless of sex and age, so that it will be of a great benefit to the diagnosis and therapy of urination related diseases.

EVALUATION OF NON-INVASIVE BLOOD GLUCOSE MEASUREMENT USING THREE TYPES OF NEAR INFRARED SPECTROMETER

  • Baek, Ju-Hyun;Kang, Na-Roo;Woo, Young-Ah;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.289.1-289.1
    • /
    • 2003
  • Three types of near infrared spectrometer, a photo diode array type, a dispersive type and a FT type, were evaluated and compared the systematic difference in blood glucose measurement. The fundamental study was performed by adding glucose to buffer solution and bovine blood as the preceding study of non-invasive blood glucose. Spectra were collected using a 1.0 mm optical pathlength quartz cell by transmittance method. (omitted)

  • PDF

Review on the Stimulating Technologies of Acupuncture Points in the Patents (특허분석을 통한 경혈 자극 기술에 대한 고찰)

  • Park, Chin-Su;Hwang, Yo-Sun;Koo, Sung-Tae
    • Korean Journal of Acupuncture
    • /
    • v.28 no.3
    • /
    • pp.113-126
    • /
    • 2011
  • Objectives : We have examined and analyzed patents regarding acupuncture point stimulating methods in order to understand the stimulation technology and research trends of acupuncture points. Methods : We searched and analyzed the total of 135 on-line DB based patents under time limit of Dec, 2010. Results : According to the analyzed results, non-invasive method is used more than invasive method. Electric stimulation is used more than any other method, such as magnetic, ionic, laser, light, ultrasonic, water, Far IR and thermal stimulation. There are numbers of cases such as rejected during screening procedure, waived before the screening, of failed to renew its registrational status which outnumber those patents registered and maintained. Conclusions : These data suggest that we need to move away from using one side method such as non-invasive and electrical method. Thus follow-up service is recommended.

Measurement of the Metabolism of Energy Substrates in Single IVF-derived Bovine Embryos (소 체외수정란에 있어서 Non-invasive 방법에 의한 기질 대사량의 측정)

  • ;;S. Sugawara
    • Korean Journal of Animal Reproduction
    • /
    • v.19 no.3
    • /
    • pp.161-169
    • /
    • 1995
  • To investigate the metabolism of various substrates in preimplantation bovine embryos, uptake of glucose and pyruvate, and lactate production were measured in single IVF-derived bovine embryos by a non-invasive method. When the embryos were incubated for 5 h in culture medium supplemented with 1 mM glucose and 0.4mM pyruvate as substrates at each developmental stage, glucose uptake was increased with more advanced developmental stages while pyruvate uptake was decreased. Total lactate producton of 2-cell embryos was significantly higher than that of blastocysts (p<0.05). Both of glucose uptake and lactate production in normal morulae produced in vitro was significantly high compared to the degenerated embryos(p<0.05). The results obtained in the study suggest that pyruvate as an exogenous substrate may be support in bovine embryos until 8-cell stage, whereas glucose may be effective as an energy source after morula stage. In addition, it was proven thatlactate was not effective as an energy source in preimplantation development of IVF-derived bovine embryos.

  • PDF

Non-invasive evaluation of embryo quality for the selection of transferable embryos in human in vitro fertilization-embryo transfer

  • Jihyun Kim;Jaewang Lee;Jin Hyun Jun
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.49 no.4
    • /
    • pp.225-238
    • /
    • 2022
  • The ultimate goal of human assisted reproductive technology is to achieve a healthy pregnancy and birth, ideally from the selection and transfer of a single competent embryo. Recently, techniques for efficiently evaluating the state and quality of preimplantation embryos using time-lapse imaging systems have been applied. Artificial intelligence programs based on deep learning technology and big data analysis of time-lapse monitoring system during in vitro culture of preimplantation embryos have also been rapidly developed. In addition, several molecular markers of the secretome have been successfully analyzed in spent embryo culture media, which could easily be obtained during in vitro embryo culture. It is also possible to analyze small amounts of cell-free nucleic acids, mitochondrial nucleic acids, miRNA, and long non-coding RNA derived from embryos using real-time polymerase chain reaction (PCR) or digital PCR, as well as next-generation sequencing. Various efforts are being made to use non-invasive evaluation of embryo quality (NiEEQ) to select the embryo with the best developmental competence. However, each NiEEQ method has some limitations that should be evaluated case by case. Therefore, an integrated analysis strategy fusing several NiEEQ methods should be urgently developed and confirmed by proper clinical trials.

1/f-LIKE FREQUENCY FLUCTUATION IN FRONTAL ALPHA WAVE AS AN INDICATOR OF EMOTION

  • Yoshida, Tomoyuki
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.04a
    • /
    • pp.99-103
    • /
    • 2000
  • There are two approaches in the study of emotion in the physiological psychology. The first is to clarify the brain mechanism of emotion, and the second is to evaluate objectively emotions using physiological responses along with our feeling experience. The method presented here belongs to the second one. Our method is based on the "level-crossing point detection" method. which involves the analysis of frequency fluctuations of EEG and is characterized by estimation of emotionality using coefficients of slopes in the log-power spectra of frequency fluctuation in alpha waves on both the left and right frontal lobe. In this paper we introduce a new theory of estimation on an individual's emotional state by using our non-invasive and easy measurement apparatus.

  • PDF