• Title/Summary/Keyword: non-invasive analysis

Search Result 292, Processing Time 0.034 seconds

Review of Non-invasive Interventions for Drooling Problems in Children With Cerebral Palsy: Trends and Analysis of Interventions for Drooling (신경발달장애 아동의 침흘림치료를 위한 비침습적 중재방법에 관한 고찰: 경향 및 중재방법 분석)

  • Jeon, Joo young;Park, Hae Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.10 no.2
    • /
    • pp.37-51
    • /
    • 2021
  • Objective : The purpose of this study was to analyze non-invasive treatments and drooling assessment methods in children with cerebral palsy and developmental disabilities, who drool. Methods : This study searched two hundred papers published in 2005-2019. Forty-four papers were selected based on their abstract and title, and ten papers were finally selected following a secondary search. Results : The PEDro Scale of the selected papers was high with an average of seven points. As a result of analyzing the overall trends, the study participants were primarily patients with cerebral palsy, and recently, the therapeutic intervention of oral sensory exercise was more actively studied than behavioral modification. Studies of behavioral modification and oral sensory exercise intervention methods were found to have differences in participant age and, cognitive level, number of participants, research design, treatment time, and duration. Studies to confirming the frequency and severity of the drooling measurement method were found to be the main factor. Conclusion : This study analyzed typical behavioral modification and oral sensory exercise interventions as examples of non-invasive therapeutic interventions for children with cerebral palsy and developmental disabilities and provided information to help select appropriate therapeutic intervention methods when planning non-invasive therapy using behavioral modification and oral sensory exercise therapy.

A Study of Phonation Pharyngogram in Functional Voice Disorders (기능성 음성 질환에서 발성 인두조영술의 사용에 관한 연구)

  • 안철민;문고정;정덕희
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.12 no.2
    • /
    • pp.133-139
    • /
    • 2001
  • Background and Objectives : There are so many methods to investigate the causes of voice disorders. However, they were almost invasive or non-physiologic methods. And none of them showed the laryngeal movements. Phonation pharyngogram is non-invasive method to see the laryngeal movement directly. Authors studied to evaluate the availability of phonation pharyngogram in laryngeal nodule. Materials and Methods : 30 laryngeal nodules and 10 control groups were evaluated. Acoustic analysis and maximum phonation time were measured and pharyngogram was taken during sustaining /a/ phonation immediately after swallowing the barium. We measured the width of hypopharyngeal wall, shape of hypopharyngeal wall and pyriform sinus apex, level difference between both true vocal folds, angle of subglottis, location of true vocal folds, elevated distance of vocal folds and shape of c-spine. Results : Jitter, Shimmer of laryngeal nodule were higher than control group and maximum phonation time was shorter in laryngeal nodule. There was a significance in width of hypopharyngeal wall, shape of pyriform sinus apex, level difference between both true vocal folds, elevated distance of vocal folds and shape of c-spine. Conclusions : Authors knew that there were differences when we used the phonation pharyngogram between normal group and laryngeal nodule group.

  • PDF

Muscular Adaptations and Novel Magnetic Resonance Characterizations of Spinal Cord Injury

  • Lim, Woo-Taek
    • Physical Therapy Korea
    • /
    • v.22 no.2
    • /
    • pp.70-80
    • /
    • 2015
  • The spinal cord is highly complex, consisting of a specialized neural network that comprised both neuronal and non-neuronal cells. Any kind of injury and/or insult to the spinal cord leads to a series of damaging events resulting in motor and/or sensory deficits below the level of injury. As a result, muscle paralysis (or paresis) leading to muscle atrophy or shrinking of the muscle along with changes in muscle fiber type, and contractile properties have been observed. Traditionally, histology had been used as a gold standard to characterize spinal cord injury (SCI)-induced adaptation in spinal cord and skeletal muscle. However, histology measurements is invasive and cannot be used for longitudinal analysis. Therefore, the use of conventional magnetic resonance imaging (MRI) is promoted to be used as an alternative non-invasive method, which allows the repeated measurements over time and secures the safety against radiation by using radiofrequency pulse. Currently, many of pathological changes and adaptations occurring after SCI can be measured by MRI methods, specifically 3-dimensional MRI with the advanced diffusion tensor imaging technique. Both techniques have shown to be sensitive in measuring morphological and structural changes in skeletal muscle and the spinal cord.

Research on Subcutaneous Pulse Shape Measurement by Near-infrared Moiré Technique

  • Chen, Ying-Yun;Liu, Zhizhen;Du, Jian;Chang, Rong-Seng
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • A pulse is generated when the heart pumps blood into the arterial system. The heart pumps blood only when it contracts, not when it relaxes; therefore, blood enters the arterial system in a cyclical form. Artery beating is visible in some parts of the body surface, such as the radial artery of the wrist. This paper mainly uses the feature in which near-infrared spectroscopy penetrates skin to construct a non-invasive measurement system that can measure small vibration in the subcutaneous tissue of the human body, and then uses it for the pulse measurement. This measurement system uses the optical moir$\acute{e}$ principle, together with the fringe displacement made by small vibration in the subcutaneous tissue, and an image analysis program to calculate the height variation from small vibrations in the subcutaneous tissue. It completes a measurement system that records height variation with time, and that together with a fast Fourier transform (FFT) program, they can convert the pulse waveform generated by vibration (time-amplitude) to heartbeat frequency (frequency-amplitude). This is a new and non-invasive medical assistance system for measuring the pulse of the human body, with the advantages of being simple, fast, safe and objective.

Clinical improvement of amino propane sulfonic acid and it's quantitative measurement with a new opticoprofilometry (Amino propane sulfonic acid의 임상적 개선효과 및 새로운 opticoprofilometry 방법에 의한 정량분석)

  • 선보경;이해광
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.21 no.1
    • /
    • pp.1-18
    • /
    • 1995
  • We had tested the effect of amino propane sulfonic acid(APSA) on the human skin with non-invasive technique. It was tested with four parameters that were hydration, elasticity, color and skin wrinkles. In vitro culture systems, APSA stimulated the proliferation of fibroblasts bolt it didn't stimulate that of keratinocyte. Also we obtained the similar effects in the raft culture method. So we concluded that APSA affected the dermal region than the epidermal region. In clinical tests, APSA changed the skin color, pbiomechanical properties(especially elasticity) and reduced skin wrinkles of the volunteers. And we could get the better results of skin wrinkle improvement by use of Skin Visiometer than Silflo Image analysis systems.

  • PDF

Understanding Diffusion in Cells and Living Tissues (세포 및 생체조직에서 확산에 관한 이해)

  • Kim, Jung-Kyung
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.1
    • /
    • pp.12-15
    • /
    • 2007
  • Macromolecule diffusion in cells and tissues is important for cell signaling, metabolism and locomotion. Biophysical methods, including non-invasive or minimally invasive in-vivo photobleaching techniques and single quantum-dot tracking, have been used to measure the rates of macromolecule diffusion in living cells and tissues, including central nervous system and tumors. Mathematical modeling and statistical analysis of experimental data revealed various modes of diffusion, which are strongly coupled with spatiotemporal changes in nanoscale structures and material properties.

Near Infrared Reflectance Spectroscopy for Non-Invasive Measuring of Internal Quality of Apple Fruit

  • Sohn, Mi-Ryeong;Park, Woo-Churl;Cho, Rae-Kwang
    • Near Infrared Analysis
    • /
    • v.1 no.1
    • /
    • pp.27-30
    • /
    • 2000
  • In this study, we investigated the feasibility of non-destructive determination of internal quality factors of Fuji apple fruit using near infrared(NIR) reflectance spectroscopy and developed the calibration models. As the reference methods, refractometer, titration and texture analyzer for sugar content, acidity and firmness were used, respectively. Samples were scanned from 1100∼2500nm with InfraAlyzer 500C spectrometer and SESAME software was used for data analysis. A multiple linear regression(MLR) analysis was performed to develop the calibrations. The correlation coefficient(R) and standard error of prediction(SEP) were as follows; 0.91, 0.41$^{\circ}$Brix for sugar content, 0.90, 0.04% for acidity and 0.84, 0.094 kg for firmness, respectively. This study shows that NIR spectroscopy can be used to evaluate the sugar content acidity and firmness of apple fruit with acceptable accuracy.

Noninvasive Evaluation of Coronary Artery Bypass Graft Patency by Electron Beam Tomography (전자선 단층 촬영을 이용한 관상동맥 우회로 개존의 비침습적 평가)

  • 최규옥;김호석;조범구
    • Journal of Chest Surgery
    • /
    • v.32 no.8
    • /
    • pp.693-701
    • /
    • 1999
  • Recently non-invasive diagnostic imaging replaced the invasive catheter angiography in the diagnosis of vascular disease. Catheter methods are now almost confined to the purpose of intervention. Coronary artery or coronary artery bypass graft still needs catheter technique because of small diameter and the cardiac motion. The last challenge for radiologists in this domain is to obtain a non-invasive imaging. Electron beam tomography(EBT) for high temporal resolution is able to obtain a coronary arteriogram or coronary artery bypass graft (CABG), of which CABG imaging is quite useful for the evaluation of patency. In our experience as well as others, the accuracy of EBT angiogram in evaluating CABG patency revealed that the accuracy of patency of saphenous vein grafts(SVG) is high due to relatively wide lumen, short and straight course and less influence from cardiac motion. The sensitivity and specificity of patency of SVGs were 92%, 97% respectively in the prospective evaluat on and 100% each in the retrospective evaluation. A false positive and a false negative case are rudimentary errors in the initial learing period. In contrast the analysis of left internal mammary artery(LIMA) graft was difficult due to the inherent small size and the adjacent surgical clips provoking beam-hardening artifact; therefore, the method of combining 3 dimensional reconstruction and flow mode study was important in improving the accuracy of LIMA patency. The sensitivity and specificity of LIMA patency were 100% and 80% in both prospective and retrospective evaluation. Therefore, EBT angiography is an accurate non-invasive diagnostic modality for evaluating the patency of CABG, particularly in SVGs. The accuracy can be improved with the improvement of the EBT and the development of the image reconstruction software.

  • PDF

Preoperative Magnetic Resonance Imaging Features Associated with Positive Resection Margins in Patients with Invasive Lobular Carcinoma

  • Jiyoung Yoon;Eun-Kyung Kim;Min Jung Kim;Hee Jung Moon;Jung Hyun Yoon;Vivian Y. Park
    • Korean Journal of Radiology
    • /
    • v.21 no.8
    • /
    • pp.946-954
    • /
    • 2020
  • Objective: To investigate preoperative magnetic resonance imaging (MRI) findings associated with resection margin status in patients with invasive lobular carcinoma (ILC) who underwent breast-conserving surgery. Materials and Methods: One hundred and one patients with ILC who underwent preoperative MRI were included. MRI (tumor size, multifocality, type of enhancing lesion, distribution of non-mass enhancement [NME], and degree of background parenchymal enhancement) and clinicopathological features (age, pathologic tumor size, presence of ductal carcinoma in situ [DCIS] or lobular carcinoma in situ, presence of lymph node metastases, and estrogen receptor/progesterone receptor/human epidermal growth factor receptor type 2 status) were analyzed. A positive resection margin was defined as the presence of invasive cancer or DCIS at the inked surface. Logistic regression analysis was performed to determine pre- and postoperative variables associated with positive resection margins. Results: Among the 101 patients, 21 (20.8%) showed positive resection margins. In the univariable analysis, NME, multifocality, axillary lymph node metastasis, and pathologic tumor size were associated with positive resection margins. With respect to preoperative MRI findings, multifocality (odds ratio [OR] = 3.977, p = 0.009) and NME (OR = 2.741, p = 0.063) were associated with positive resection margins in the multivariable analysis, although NME showed borderline significance. Conclusion: In patients with ILC, multifocality and the presence of NME on preoperative breast MRI were associated with positive resection margins.

Validity of Bioelectrical Impedance Analysis(BIA) in Measurement of Human Body Composition (소아 체지방 평가를 위한 생체 저항분석법의 타당성 연구 : 이중 에너지 방사선 흡수법과의 비교)

  • Kim, Hyung-Suck;Kim, Su-Yung
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.696-700
    • /
    • 2005
  • Propose : Body composition by bioelectrical impedance analysis(BIA) is a very useful method of analysing body composition. BIA is non-invasive, inexpensive, nonhazaedous and reproducible technique. The aim of this study was to determine the level of agreement between body composition measurement by BIA and dual-energy X-ray absorptiometry(DEXA). Methods : Data was examined in 100 children(male 58; female 42), who visited Pusan National Hospital. Weight(kg) and height(cm) were measured, and body compositions were analyzed with fat mass, lean body mass, body fat percent by BIA and DEXA methods. Results : Comparison of the DEXA and BIA methods showed highly statistically significant correlations in measurement of human body composition(fat mass, lean body mass, body fat percent). Conclusion : BIA should be considered as the method of choice in measurement of human body composition, since it's non-invasive, reliable, rapid, nonhazaedous and inexpensive, using portable equipment.