• Title/Summary/Keyword: non-invasive analysis

Search Result 291, Processing Time 0.04 seconds

Consideration of the Usefulness of 18F-FET Brain PET/CT in Brain Tumor Diagnosis (뇌종양진단에 있어 18F-FET Brain PET/CT의 유용성에 대한 고찰)

  • Kyu-Ho Yeon; Jae-Kwang Ryu
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.28 no.1
    • /
    • pp.41-47
    • /
    • 2024
  • Purpose: 18F-FET, a radiopharmaceutical based on a Tyrosine amino acid derivative using the Sodium-Potassium Pump-independent Transporter (System L) for non-invasive evaluation of primary, recurrent, and metastatic brain tumors, exhibits distinct characteristics. Unlike the widely absorbed 18F-FDG in both tumor and normal brain tissues, 18F-FET demonstrates specific uptake only in tumor tissue while almost negligible uptake in normal brain tissue. This study aims to compare and evaluate the usefulness of 18F-FDG and 18F-FET Brain PET/CT quantitative analysis in brain tumor diagnosis. Materials and Methods: In 46 patients diagnosed with brain gliomas (High Grade: 34, Low Grade: 12), Brain PET/CT scans were performed at 40 minutes after 18F-FDG injection and at 20 minutes (early) and 80 minutes (delay) after 18F-FET injection. SUVmax and SUVpeak of tumor areas corresponding to MRI images were measured in each scan, and the SUVmax-to-SUVpeak ratio, an indicator of tumor prognosis, was calculated. Differences in SUVmax, SUVpeak, and SUVmax-to-SUVpeak ratio between 18F-FDG and 18F-FET early/delay scans were statistically verified using SPSS (ver.28) package program. Results: SUVmax values were 3.72±1.36 for 18F-FDG, 4.59±1.55 for 18F-FET early, and 4.12±1.36 for 18F-FET delay scans. The highest SUVmax was observed in 18F-FET early scans, particularly in HG tumors (4.85±1.44), showing a slightly more significant difference (P<0.0001). SUVpeak values were 3.33±1.13 for 18F-FDG, 3.04±1.11 for 18F-FET early, and 2.80±0.96 for 18F-FET delay scans. The highest SUVpeak was in 18F-FDG scans, while the lowest was in 18F-FET delay scans, with a more significant difference in HG tumors (P<0.001). SUVmax-to-SUVpeak ratio values were 1.11±0.09 for 18F-FDG, 1.54±0.22 for 18F-FET early, and 1.48±0.17 for 18F-FET delay scans. This ratio was higher in 18F-FET scans for both HG and LG tumors (P<0.0001), but there was no statistically significant difference between 18F-FET early and delay scans. Conclusion: This study confirms the usefulness of early and delay scans in 18F-FET Brain PET/CT examinations, particularly demonstrating the changes in objective quantitative metrics such as SUVmax, SUVpeak, and introducing the SUVmax-to-SUVpeak ratio as a new evaluation metric based on the degree of tumor malignancy. This is expected to further contributions to the quantitative analysis of Brain PET/CT images.

Evaluation of Post-Neoadjuvant Chemotherapy Pathologic Complete Response and Residual Tumor Size of Breast Cancer: Analysis on Accuracy of MRI and Affecting Factors (신보강화학요법 후 유방암의 병리학적 완전 관해 예측 및 잔류 암 평가: 유방자기공명영상의 정확도 및 영향인자 분석)

  • Hyun Soo Ahn;Yeong Yi An;Ye Won Jeon;Young Jin Suh;Hyun-Joo Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.654-669
    • /
    • 2021
  • Purpose To evaluate the accuracy of MRI in predicting the pathological complete response (pCR) and the residual tumor size of breast cancer after neoadjucant chemotherapy (NAC), and to determine the factors affecting the accuarcy. Materials and Methods Eighty-eight breast cancer patients who underwent surgery after NAC at our center between 2010 and 2017 were included in this study. pCR was defined as the absence of invasive cancer on pathological evaluation. The maximum diameter of the residual tumor on post-NAC MRI was compared with the tumor size of the surgical specimen measured pathologically. Statistical analysis was performed to elucidate the factors affecting pCR and the residual tumor size-discrepancy between the MRI and the pathological measurements. Results The pCR rate was 10%. The diagnostic accuracy of MRI and the area under the curve for predicting pCR were 90.91% and 0.8017, respectively. The residual tumor sizes obtained using MRI and pathological measurements showed a strong correlation (r = 0.9, p < 0.001), especially in patients with a single mass lesion (p = 0.047). The size discrepancy between MRI and the pathological measurements was significantly greater in patients with the luminal type (p = 0.023) and multifocal tumors/non-mass enhancement on pre-NAC MRI (p = 0.047). Conclusion MRI is an accurate tool for evaluating pCR and residual tumor size in breast cancer patients who receive NAC. Tumor subtype and initial MRI features affect the accuracy of MRI.

Pulse wave velocity and ankle brachial index in normal adolescents (정상 청소년에서 맥파 속도와 발목 상완 동맥압 지수에 대한 연구)

  • Kim, Ji Hye;Gil, Tae Young;Lee, Hee Woo;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.6
    • /
    • pp.549-555
    • /
    • 2007
  • Purpose : Pulse wave velocity (PWV) and ankle brachial index (ABI) are simple, non-invasive methods to assess arterial stiffness. These parameters are also known to be closely related to cardiovascular risk factors and diseases. The purposes of this study were to measure blood pressure, PWV, ABI in healthy Korean adolescents, set up their normal values and assess their correlations. Methods : Three hundred ninety two healthy adolescents (213 boys and 179 girls) underwent measurement of brachial ankle pulse wave velocity (baPWV), ABI, body mass index(BMI) and blood pressure from four extremities. Linear regression analysis was performed to reveal the correlations between PWV, ABI and independent variables. Results : Blood pressure and PWV were significantly higher in all extremities in males compared to females. Blood pressure of both brachial and ankle showed positive correlation with body weight, height, and BMI, whereas ABI showed no correlation with any of these indices. Conclusion : Blood pressure increases as body weight, height and BMI increases. PWV shows positive correlation with blood pressure. It will be helpful to predict the risks of cardiovascular diseases in adolescents.

The In-hospital Analysis of Outcome of Off-pump CABG and On-pump CABG (비체외순환 및 체외순환하에서의 관상동맥우회로술의 임상 고찰)

  • 안재범;김인섭;정성철;배윤숙;유환국;김병열;김우식
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.762-767
    • /
    • 2004
  • With the developement of non-invasive surgical techeniques, coronary artery bypass graft without cardiopulmonary bypass has become popular. We compared the preoperative risk factors and in-hospital outcomes of patients having off-pump CABG with these having on-pump CABG. Material and Method: From January 2001 to June 2003, 87 patients underwent CABG. Thirty-sin patients underwent on-pump CABG, fifty-one patients under-went off-pump CABG. Preoperative risk factors, extent of coronary disease, operative time, postoperative endotracheal intubation time, duration of ICU stay & hospital stay, the amount of bleeding and postoperative levels of cardiac enzymes were compared in both groups, Result: The were no differences in their sex ratios, ages, preoperative risk factors, preoperative Ml, Canadian classes, extent of coronary artery diseases and, echocardio-graphic ejection fraction between Off-pump CABG and On-pump CABG groups. Off-pump CABG group had significantly lower mean operative time (270$\pm$79.3 min vs 372$\pm$142.2 min, p<0.001), mean ventilation time (17.1$\pm$13.4 hr vs 24.3$\pm$17.8 hr) and CK-MB level (8,9$\pm$18.7 IU/L vs 25.7$\pm$8.4 IU/L) than on-pump CABG groups, On-pump CABG group had more distal grafts (2.2$\pm$0.5 vs 1.7$\pm$0.71 than Off-pump CABG groups did. There were no differences in their postoperative complications and outcomes including amount of postoperative bleeding for 24 hrs, reoperation for bleeding control, mean in-hospital days, postoperative infection, renal failure and neurologic complications between Off-pump CABG and On-pump CABG groups. Conclusion: This study showed that patients who underwent Off-pump CABG had less operation time & intubation time and lower CK-MB level; however, they also have less distal graft. Even though CABG without CPB provided satisfactory results, more clinical experience & longer follow-up is required.

A Clinical Study of Childhood Henoch-Schönlein Purpura (Henoch-Schönlein 자반증 환아의 임상적 고찰)

  • Ha, Tae-Sun;Koo, Hyun-Hoe
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.11
    • /
    • pp.1118-1123
    • /
    • 2003
  • Purpose : Henoch-$Sch{\ddot{o}}nlein$ purpura(HSP) is a systemic vasculitis, characterized by cutaneous purpura, abdominal pain, arthralgia and renal involvement. The clinical features of HSP have been reasonably well documented but there are still many gaps in our understanding of HSP. The aim of this study was to present the clinical features of 125 children with HSP and compare them with previous reports, placing particular emphasis on clinical information. Methods : We collected the clinical data of 125 patients with acute HSP who visited Chungbuk National University Hospital from March 1992 to April 2002. Data were expressed as the mean or $mean{\pm}SD$ and statistical analysis was performed using Chi-square approximation. P<0.05 was considered as significant. Results : The patient population consisted of 87 boys and 38 girls ranging in age from one to 14 years. HSP occurs throughout the year, but this study shows seasonal skewing, with most patients presenting from fall through spring and a paucity of cases in summer. All patients had non-thrombocytopenic purpura concentrated on the buttocks and lower extremities. Purpuric lesions were also scattered on the arms and occaisionally on the face and ears, but the trunk was largely spared. A recurrence of purpura was defined as the reappearance of a rash or other symptoms following resolution of disease for at least two weeks. The mean number of recurrences was 0.51. Eighty eight patients(70.4%), 18 patients(14.4%) and 67 patients(53.6%) complained of abdomianl pain, gastrointestinal bleeding and arthralgia, respectively. Nephritis occurred in 48(38.4%) patients. Fifteen boys (17.2%) developed epididymitis. Neurologic features occurred in 13(10.4%) and two(15%) of these were seizures. Conclusion : HSP all showing purpura as defined is characterized by various clinical features, including abdominal pain, arthralgia, epididymitis and nephritis which could occur before the appearance of purpura. Therefore, we suggest that the possibility of HSP should be considered in children before invasive procedures, even if the above symptoms and signs present without purpura.

Analysis of 1,000 Cases of Abdominal Ultrasonography Performed by a Pediatrician (소아과 의사에 의해 시행된 복부 초음파 검사 1,000예에 대한 분석)

  • Bae, Sang-In;Park, Jae-Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.1
    • /
    • pp.28-35
    • /
    • 2007
  • Purpose: The aim of this study was to evaluate the clinical usefulness of ultrasound examination of children performed by a pediatrician. Methods: One thousand children who presented with symptoms of a gastrointestinal disorder and underwent abdominal ultrasound evaluation in the Department of Pediatrics, between January 2003 and June 2006, were included in this study. We analyzed the patient's medical records and ultrasound results retrospectively. Results: Among the 1,000 patients, 58.4% were male and 41.6% were female. The mean age of the patients was $4.7{\pm}4.0$ years. The main reasons for ultrasound were abdominal pain (43.9%), vomiting (17.3%), elevated liver enzymes (11.8%), and jaundice (9.8%). Abnormal ultrasound findings were present in 57.9% of cases. The major abnormal findings were mesenteric lymphadenitis (29.2%), fatty liver (12.1%), hepatitis (6.4%), hepatosplenomegaly (6.2%), and acute appendicitis (4.8%). The time interval between the initial medical evaluation and the ultrasound evaluation was within 24 hours in most cases (78.5%). The main findings in children with abdominal pain were mesenteric lymphadenitis (32.6%), fatty liver (5.9%), intussusception (2.7%), and acute appendicitis (2.7%). The main findings in children with vomiting were mesenteric lymphadenitis (12.7%), hypertrophic pyloric stenosis (10.4%), and acute appendicitis (3.5%). The major ultrasound findings in children with urinary tract diseases were hydronephrosis (45.4%), urolithiasis (21.5%) and cystic renal disease (18.1%). Conclusion: Ultrasound examination played an important role as a non-invasive and prompt screening examination for detection of abdominal diseases. Ultrasound was an important tool for pediatricians to determine timely information for patient management.

  • PDF

Pediatric Urolithiasis: Our 22-year Experience at a Single Center (소아에서의 요로결석: 단일기관에서 22년간의 경험)

  • Kim, Su-Yon;Kim, Min-Jee;Lee, Joo Hoon;Kim, Kun Suk;Park, Young Seo
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.101-109
    • /
    • 2013
  • Purpose: Pediatric urolithiasis is uncommon in children but is a cause of significant morbidity and damage to the kidney. Although much information on adult urolithiasis is available in the literature, large studies on the pediatric population are still scarce. In this report, we review our experience with pediatric urolithiasis over 22 years at a tertiary referral center. Method: We retrospectively reviewed the records of children with newly diagnosed urolithiasis between January 1991 and May 2013. We assessed the age, sex, family history, initial symptoms, location of stones, underlying cause, stone analysis, treatment, and recurrence among the patients. Results: In total, 137 patients (96 male, 41 female) were assessed. The age range was 0-17 years (mean age, 6.0 years). Forty-three (31%) children were aged <1 year, and 37% (16/43) had a history of intensive care unit (ICU) admission. Thirteen patients (9.5%) had a family history of stones. The most common symptoms at presentation among the patients were gross hematuria (56/137, 41%) and flank or abdominal pain (46/137, 34%). The stones were located in the kidney (85/137, 62%), ureter (29/137, 21%), bladder (2/137, 1.4%), and multiple locations (20/137, 15 %). Congenital abnormalities of the genitourinary (G-U) tract, with or without metabolic abnormality, or urinary tract infection (UTI) was detected in 26 children (19%). Ninety-one patients (66%) underwent metabolic examination, and 38% of these patients exhibited an abnormality. UTI, with or without abnormalities of the G-U tract, or metabolic abnormality was detected in 26 children (19%). Of the 35 stones analyzed, the majority were calcium stones (20/35, 57%), followed by infected stones (5/35, 14%), uric acid stones (4/35, 11%), carbonate apatite stones (3/35, 7%), cystine stones (2/35, 6%), and phosphate stones (1/35, 3%). Five patients (4%) required open procedures, with or without non-open procedures, whereas 77 patients (56%) were managed conservatively; the remaining 55 patients (40%) received some other form of intervention. Eighteen patients (13%) had stone recurrence during the follow-up period. Conclusions: Pediatric urolithiasis is commonly associated with abnormalities of the G-U tract and/or metabolic disorders and/or UTI. Half of the patients will pass their stones spontaneously, and all the techniques of minimally invasive surgery are applicable in the treatment of children with stones. As the recurrence rates are high among this population, long-term follow-up is recommended and the complete clearance of stones is important.

Biodiversity and Characteristic Communities Structure of Freshwater Ecosystems in the Western Area of DMZ, Korea (민통선이북지역(DMZ) 서부평야 일대의 수생태계 생물다양성 및 군집 특성)

  • Jung, Sang-Woo;Kim, Yoon-Ho;Kim, Hyun-Mac;Kim, Su-Hwan
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.6
    • /
    • pp.603-617
    • /
    • 2018
  • This study surveyed the diversity and community characteristics of benthic macroinvertebrates and freshwater fish, which are the main animal classifications in a hydro ecosystem, from May to September 2017 in the western plains of the Demilitarized Zone (DMZ). The results showed a total of 125 species of benthic macroinvertebrates belonging to 66 families, 19 orders, and four phyla in the streams and wetlands. Among benthic macroinvertebrates, Coleoptera (27 spp.: 21.60%) was the largest group in terms of species richness followed by Odonata (26 spp.: 20.80%), non-Insecta (22 spp.: 17.60%), and Hemiptera (11 spp.: 8.80%) occupying in the lentic area. Of the feeding function groups (FFGs), predators (51 spp.: 56.67%) showed a relatively larger presence, indicating the dominance of hygrophilous invertebrates that usually inhabit the freshwater wetlands or ponds. Of the habitat oriented groups (HOGs), climbers (33 spp.: 24.44%) and burrowers (17 spp.: 12.59%) were the dominant groups. This observation is typical in a slow flowing habitat and can lead to the disturbance of the ecosystem due to cannibalism among predators. Cannibalism can be caused by stress induced by various population and environmental factors. For the ecosystem services benchmark (ESB) value, site 13 appeared to be the highest with 82 marks while other sites showed relatively lower rates and indices (III water quality class with ${\alpha}$-mesosaprobic). The analysis result of stability factors showed that almost all sites were evaluated to be the I characteristic group with high resilience and resistance or the III characteristic group that was sensitive to environmental disturbance and formed uneven and unstable communities. Of the freshwater fishes, 46 species (3,405 individuals) belonging to 39 families and 18 orders were identified in all the investigated sites. Among them, Cyprinidae (30 spp.: 65.2%) was the largest group, and Zacco koreanus was identified as the dominant species (728 individuals, 21.4%). The survey of freshwater fish communities found both stable communities (sites 7 and 13) with low dominant index (0.39) and high diversity index (2.29) and unstable communities (sites 2, 3, 8, and 10) in opposite tendency. This survey found five Korean endemic species, 17 species belonging to the export controlled species, two endangered species level II (Lethocerus deyrollei and Cybister chinensis), and rare species (Dytiscus marginalis czerskii) among benthic macroinvertebrates. The survey also found an invasive species, Ampullarius insularus, which was distributed throughout the whole area and thus can continuously disturb the ecosystem in the western plain area in the DMZ. Of freshwater fish, one natural monument (Hemibarbus mylodon) and three endangered species level II (Acheilognathus signifer, Gobiobotia macrocephalus, and G. brevibarba) were observed. The survey also found four introduced species (Pomacea canaliculate, Carassius cuvieri, Lepomis macrochirus, Micropterus salmoides) in the western DMZ area, indicating the need for the protection and conservation measures.

GET Imaging Evaluation of Patients with Esophageal Cancer (식도암 환자의 GET 영상 평가)

  • Moon, Jong Wun;Lee, Chung Wun;Seo, Young Deok;Yun, Sang Hyeok;Kim, Yong Keun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.31-36
    • /
    • 2013
  • Purpose: Measure gastric emptying time (GET: Gastric Emptying Time) is a non-invasive and quantitative evaluation methods, mainly by endoscopic or radiological examination confirmed no mechanical obstruction in patients with symptoms of congestion is checked. Such tests are not common gastric emptying time measured esophageal cancer patients (who underwent esophagectomy) patients after surgery for gastric emptying time was measured test. And the period of time for more than one year after the gastric emptying time measurement was performed. By comparing the two kinds of tests in the chest cavity after surgery as the evaluation of gastrointestinal function tests evaluate the usefulness of GET, and will evaluate the characteristics of the image. Materials and Methods: 93 patients who underwent esophagectomy with gastric emptying time measurement of subject tests immediately after surgery and after 1 year or longer were twice. Preparation of the patient before the test is more than 12 hours of overnight fasting is important, in addition to the medicine or to stop smoking, and diabetes insulin injections should be early in the morning is ideal to test. Generally labeled with $^{99m}Tc-DTPA$ resin which is used to make steamed egg, seaweed and fermented milk with a high viscosity after eating, three hours in the standing position was measured. Evaluation of gastric emptying curves on the way intragastric radioactivity level by 50% the time (half-time [T1/2]) was calculated, based on the half-life was divided into three steps: over 180 minutes was defined as delayed gastric emptying, within 180minutes was defined as intermediate gastric emptying and when all the radioisotopes were dumped into the jejunum as soon as swallowed, was defined as rapid gastric emptying. Results: Gastric emptying time of a typical images stomach of antrum and fundus additional images appear stronger over time move on to the small intestine. but esophageal cancer who underwent esophagectomy side of the thoracic cavity showed a strong image. Immediately after surgery, the half-time (T1/2) of rapid gastric emptying appeared to 12.9%, intermediate gastric emptying appeared to 52.7%, delay gastric emptying appeared to 34.4%. After more than a year the results of the half-life after surgery, 67% of rapid gastric emptying to intermediate gastric emptying was changed, 69% of delay gastric emptying to intermediate gastric emptying changed. Intermediate gastric emptying worse in patients rapid gastric emptying and the delay gastric emptying is 24% in the case. Conclusion: Esophagectomy for esophageal cancer who underwent half-time measurement test (T1/2) rapid gastric emptying and delay gastric emptying are the result of the comparison over time, changes were observed intermediate gastric emptying. Mainly seeing of gastric emptying time measurement in the esophagus instead of thoracic cavity to check the evaluation of gastrointestinal function can be useful even means. And segmentation criteria and narrow time interval of checking if more accurate information and analysis of the clinical diagnosis and evaluation seems to be done.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF