Non-intrusive measurement of pulse arrival time and Estimation of Systolic Blood Pressure (무구속적 맥파 전달 시간의 측정을 통한 혈압 추정)

  • Chee, Young-Joon;Park, Kwang-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.489-492
    • /
    • 2005
  • Even though the blood pressure is one of the most widely used index for the healthcare monitoring of hypertensive and normotensive persons, there is no non-intrusive measurement method which is commercialized until now. Pulse Arrival Time (PAT) is known that it has close relation with the systolic blood pressure (SBP) and arterial stiffness. In this study, SBP estimation methods by non-intrusive measurement of PAT are suggested. For the unconstrained measurement of PAT, the first method used the electrically non contact electrocardiogram (ENC-ECG) technique and the reflective type of Photoplethysmography (PPG) sensor on the computer mouse. In the second method, ENC-ECG and the air pressure sensor in the seat cushion on a chair were measured. The third method used ECG electrodes and PPG sensors on the toilet seat cover. The validation and regression analysis of the relationship of PAT and SBP are summarized. These methods have considerable errors to be used for all people. But these can be applied for each subject after the parameter customization within acceptable error. So, it is feasible for suggested methods to be used for monitoring of SBP in daily life in non-intrusive way when there is personal identification system of each subject.

  • PDF

Development of Chair Backrest for Non-intrusive Simultaneous Measurement of ECG and BCG (심전도와 심탄도의 무구속적 동시 측정을 위한 의자 등받이 개발)

  • Lim, Yong-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.3
    • /
    • pp.104-109
    • /
    • 2018
  • A non-intrusive ECG and BCG measurement system is introduced. The system is built on a auxiliary backrest of a chair. The developed system is aimed to non-intrusive assessment of cardiovascular dynamic indices such as pulse arrival time(PAT) and pre-ejection period (PEP). In the system, capacitive active electrodes and capacitive grounding were used for the non-intrusive indirect-contact ECG measurement, and EMFi pressure sensor was used for the non-intrusive BCG measurement. The capacitive active electrodes and the EMFi sensor were attached on the backrest. Using the system, ECG and BCG were successfully acquired. The measured BCG showed peaks that following ECG R peaks. It was shown that the time interval between Q wave in ECG and first peak in BCG correlates Pre-ejection period measured by impedance-cardiogram. The results showed that the introduced system can be used for the non-intrusive various cardiovascular information including ECG, PAT, PEP.

Technical tendency of electric field measurements in glow discharge plasmas using laser spectroscopy (레이저를 이용한 방전 플라즈마중의 전계측정 기술 동향)

  • Choi, Y.W.;Bowden, M.;Muraoka, K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1663-1665
    • /
    • 1997
  • Direct measurements of electric fields in a glow discharge are difficult because the measurement method should be sensitive to the electric field and non-intrusive. Laser spectroscopy is very suitable in that it is non-intrusive and allow in-situ measurements to be made. In this report, the measurement techniques of electric fields in glow discharge using laser spectroscopy were described.

  • PDF

User Activity Estimation by Non-intrusively Measurement (무구속적인 측정에 의한 사용자 활동 상태 추정 기법)

  • Baek, Jong-Hun;Yun, Byoung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.5
    • /
    • pp.101-110
    • /
    • 2009
  • The unconscious and non-intrusive measurements of activity signals or physiological signals represent important enabling technologies for realizing a ubiquitous healthcare environment as well as a related UI. Particularly, non-intrusive measurements should be used in activity monitoring system for long-term monitoring. This paper is based on activity estimation by measuring the activity signals of a user using a handhold device with an accelerometer. The user activity estimation system (UAES) presented in this paper makes non-intrusive measurements of activity signals to minimize inconveniencing a user and to create a more practical implementation in real life. Thus, a variety of positions in which the handhold device can be carried by a user for daily use is considered, such as in the front/hip/shirt pockets, a backpack, on the waist, and in the hand.

A Study on Measurement of Heartrate and Respiration during Sleep using Doppler Radar: Preliminary Study (도플러 레이더를 이용한 수면 중의 심박 및 호흡 측정: 예비연구)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.264-270
    • /
    • 2017
  • A Doppler radar sensor was applied to detect respirations and heartbeats of persons who were lying on a bed. This study is preliminary study aiming at non-contact and non-intrusive respiration and heart rate monitoring during sleep in daily life. For the experiments, 10GHz Doppler radar with patch-type antenna was used and installed on the upper right and the distance between the body and the antenna was 1 m. The results show that each signal of respiration and heartbeat is observed in each frequency band however the frequency band and the waveform vary according to the subjects and the posture. The results show that the heartbeats can be detected with the peak detection in some frequency band. This study shows the feasibility of applying the Doppler radar to detection of heartbeat and respiration during sleep and further studies about heartbeat detection algorithm are required.

Experimental Verification of Compressor Blade Aeromechanics (압축기 블레이드 Aeromechanics의 시험적 검증)

  • Choi, Yun Hyuk;Park, Hee Yong;Kim, Jee Soo;Shin, Dong Ick;Choi, Jae Ho;Kim, Yeong Ryeon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.240-244
    • /
    • 2017
  • Experimental verification in the rig test stage for component development is a vital link between the aeromechanical design and structural integrity validation process. Based on this premise, Non-Intrusive Stress Measuring System was adopted on the axial compressor test rig to measure the static and dynamic tip deflection of all blades by using tip-timing sensors. Through analyzing vibration characteristics, we evaluated the vibratory stresses seen on the blades fatigue critical location; detected synchronous resonances which are the source of High Cycle Fatigue (HCF) in blades; presented non-synchronous vibration response by aerodynamic excitation and individual blade mis-tuning patterns.

  • PDF

The Modeling of the Differential Measurement of Air Pressure for Non-intrusive Sleep Monitoring Sensor System

  • Chee, Young-Joon;Park, Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.6
    • /
    • pp.373-381
    • /
    • 2005
  • The respiratory and heart beat signals are the fundamental physiological signals for sleep monitoring in the home. Using the air mattress sensor system, the respiration and heart beat movements can be measured without any harness or sensor on the subject's body which makes long term measurement difficult and troublesome. The differential measurement technique between two air cells is adopted to enhance the sensitivity. The concept of the balancing tube between two air cells is suggested to increase the robustness against postural changes during the measurement period. With this balancing tube, the meaningful frequency range could be selected by the pneumatic filter method. The mathematical model for the air mattress and balancing tube was suggested and the validation experiments were performed for step and sinusoidal input. The results show that the balancing tube can eliminate the low frequency component between two cells effectively. This technique was applied to measure the respiration and heart beat on the bed, which shows the potential applications for sleep monitoring device in home. With the analysis of the waveform, respiration intervals and heart beat intervals were calculated and compared with the signal from conventional methods. The results show that the measurement from air mattress with balancing tube can be used for monitoring respiration and heart beat in various situations.

Quantitative Acetone PLIF Measurement of Fuel Distribution in a Gas Turbine Combustor Burner (아세톤 PLIF를 이용한 가스터빈 연소기 버너 출구 연료분포의 정량적 측정)

  • Jeon, Woo-Jin;Kim, Hyung-Mo;Lee, Kang-Yeop;Yang, Su-Seok
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.4
    • /
    • pp.43-52
    • /
    • 2010
  • A non-intrusive measurement, Planar Laser Induced Fluorescence was employed to visualize and measure the fuel distribution of the non-reacting field at the burner exit of gas turbine combustor. Measurement techniques, image processing method and quantification procedure were presented. Also, concentration measurement with gas analyzer was carried out to verify the propriety of PLIF result. The PLIF result coincides well with gas analyzer measurement result. PLIF test result for several other conditions are mentioned as well.