• 제목/요약/키워드: non-detection zone

검색결과 50건 처리시간 0.023초

Defect Detection in Friction Stir Welding by Online Infrared Thermography

  • Kryukov, Igor;Hartmann, Michael;Bohm, Stefan;Mund, Malte;Dilger, Klaus;Fischer, Fabian
    • Journal of Welding and Joining
    • /
    • 제32권5호
    • /
    • pp.50-57
    • /
    • 2014
  • Friction Stir Welding (FSW) is a complex process with several mutually interdependent parameters. A slight difference from known settings may lead to imperfections in the stirred zone. These inhomogeneities affect on the mechanical properties of the FSWed joints. In order to prevent the failure of the welded joint it is necessary to detect the most critical defects non-destructive. Especially critical defects are wormhole and lack of penetration (LOP), because of the difficulty of detection. Online thermography is used process-accompanying for defect detecting. A thermographic camera with a fixed position relating to the welding tool measures the heating-up and the cool down of the welding process. Lap joints with sound weld seam surfaces are manufactured and monitored. Different methods of evaluation of heat distribution and intensity profiles are introduced. It can be demonstrated, that it is possible to detect wormhole and lack of penetration as well as surface defects by analyzing the welding and the cooling process of friction stir welding by passive online thermography measurement. Effects of these defects on mechanical properties are shown by tensile testing.

계통연계형 태양광발전 인버터를 위한 주기적인 영전류 구간을 가지는 새로운 AFD 단독운전 검출기법 (Novel AFD method of islanding detection with a periodic zero current for improving on islanding detection for grid-connected Photovoltaic inverters)

  • 고문주;최익;최주엽;송승호;이기옥
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.17-23
    • /
    • 2006
  • This paper proposes a novel active frequency drift (AFD) method for the islanding prevention of grid-connected photovoltaic inverter. To detect the islanding phenomenon of grid-connected photovoltaic (PV) inverters concerning about the safety hazards and the damage to other electric equipments, many kinds of anti-islanding methods have been presented. Among them, AFD method using chopping fraction enables the islanding detection to drift up (or down) the frequency of the voltage during the islanding situation. In this paper, injecting the periodic zero current into the basic AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 1547 with various load conditions. Detection of islanding is verified using simulation tool PSIM.

A Novel Active Anti-islanding Method for Grid-connected Photovoltaic Inverter

  • Jung, Young-Seok;Choi, Jae-Ho;Yu, Gwon-Jong
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.64-71
    • /
    • 2007
  • This paper proposes a novel active frequency drift (AFD) method to improve the islanding detection performance with minimum current harmonics. To detect the islanding phenomenon of grid-connected photovoltaic (PV) inverters concerning the safety hazards and possible damage to other electric equipment, anti-islanding methods have been described. The AFD method that uses chopping fraction (cf) enables the islanding detection to drift up (or down) the frequency of the voltage during the islanding situation. However, the performance of the conventional AFD method is inefficient and causes difficulty in designing the appropriate cf value to meet the limit of harmonics. In this paper, the periodic chopping fraction based on a novel AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 929-2000 with power quality and islanding detection time. To verify the validation of the proposed method, the islanding test results are presented. It is confirmed that the proposed method has not only less harmonic distortion but also better performance of islanding detection compared with the conventional AFD method.

한국에서의 원격탐사와 생태계 관리 (Remote Sensing and Ecosystem Management in Korea)

  • 김대선;유철상;천승규
    • 환경영향평가
    • /
    • 제3권1호
    • /
    • pp.77-82
    • /
    • 1994
  • A Nationwide survey of ecosystem in the Republic of Korea was accomplished from 1986 to 1990 and in that survey, GIS and remote sensing were used partially. This was done by the Ministry of Environment(MOE), which introduced remote sensing and GIS for environment management in late 1980's. Especially the National Institute of Environmental Research (NIER) are under the research on systematization of environmental information with an ultimate goal of application of GIS and remote sensing to environmental impact assessment. Although the Korean peninsula is in a non-tropical zone, we introduce two case studies on remote sensing applications to ecosystem managements in the Republic of Korea. One is a study on change detection in urban vegetation of Seoul with Landsat data and the other is a study on detection of insect damaged pine tree area using Landsat TM data. The techniques involved and the conclusion from these studies were relevant to vegetation studies in tropical ecosystem.

  • PDF

불검출 영역 분석을 통한 주파수 이동 단독 운전 검출 기법의 설계 방법 (Design Method for Frequency Drift Anti-islanding Detection Method Based on Analysis of Non Detection Zone)

  • 김병헌;설승기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.9-10
    • /
    • 2012
  • AFD(Active Frequency Drift), SMS(Slip-Mode frequency Shift)를 비롯한 주파수 이동 단독 운전 검출 방법은 단독 운전 발생 후, 계통의 주파수를 정상 운전 범위 밖으로 이동시켜 OUF(Over/Under Frequency) 릴레이를 동작하게 만들어 단독 운전을 검출한다. 이 방법들의 불검출 영역은 알고리즘에 의한 전류 위상각 변화율과 부하 역률 각 변화율 사이의 관계, 그리고 단독 운전 후 정상 상태(steady state) 운전 주파수에 의해 결정된다. 본 논문에서는 불검출 영역에 영향을 미치는 부하 역률 각 변화율을 분석하고 그를 바탕으로, 설계한 Q(Quality)-factor보다 낮은 Q-factor를 갖는 부하 조건에서는 항상 단독 운전을 검출할 수 있는 설계 방법을 제시한다. 제안된 방법의 유효성은 모의실험 및 실험으로 검증되었다.

  • PDF

무효전력 제어를 통한 새로운 독립운전 검출법 (A Novel Method for Anti-Islanding Using Reactive Power Control)

  • 정진범;최봉주;안강순;김희준
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권4호
    • /
    • pp.208-216
    • /
    • 2005
  • Recently, the study of islanding phenomenon, maintains its operation even when the utility grid is removed has lead to the trend of utility interactive inverters in photovoltaic generation systems. In this paper, a novel Anti-islanding method is presented. the proposed method can keep the real average power component constant by MPPT control and cause the load current frequency with only change of reactive power component under the islanding condition. its periodical change of Reactive power component can decrease the NDZ(Non-Detective zone) so that the detection of various loads will be possible. the insufficient effect if additional reactive power component to the grid is proved theoretically and the islanding detection is also confirmed from a experimental result with a inverter for 3kW photovoltaic generation system applied the proposed Anti-islanding method.

Islanding Detection Method for Inverter-based Distributed Generation Systems using a Signal Cross-correlation Scheme

  • Bae, Byung-Yeol;Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.762-768
    • /
    • 2010
  • This paper describes the development of a new islanding detection method for inverter-based distributed generation systems, which uses a signal cross-correlation scheme between the injected reactive current and the power frequency deviation. The proposed method injects 1% of the reactive current to the rated current which brings about a negligible degradation of the power quality. It discriminates the islanding state, when the calculated cross-correlation index is larger than 0.5. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software and experimental research with a hardware prototype. The proposed method can detect the islanding state without degrading the power quality at the point of common connection. Further study is required to overcome the cancellation of the injected reactive current from multiple distributed generation units interconnected with the utility grid.

Comparison of Three Active-Frequency-Drift Islanding Detection Methods for Single-Phase Grid-Connected Inverters

  • Kan, Jia-rong;Jiang, Hui;Tang, Yu;Wu, Dong-chun;Wu, Yun-ya;Wu, Jiang
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.509-518
    • /
    • 2019
  • A novel islanding detection method is proposed in this paper. It is based on a frequency drooping PLL, which was presented in a previous work. The cause of errors in the non-detection zone (NDZ) of conventional frequency disturbance islanding detection methods (IDM) is analyzed. A frequency drooping phase-locked-loop (FD-PLL) is introduced into a single-phase grid-connected inverter (SPGCI), which can guarantee that grid current is in phase with the grid voltage. A novel FD-PLL IDM is proposed by improving this PLL. In order to verify the performance of the proposed FD-PLL IDM, a full performance comparison between the proposed IDM and typical existing active frequency drift IDMs is carried out, which includes both dynamic performance and steady performance. With the same NDZ, the total harmonic distortion of the grid-current in the dynamic process and steady state is analyzed. The proposed FD-PLL IDM, regardless of the dynamic or steady process, has the best power quality. Experimental and simulation results verify that the proposed FD-PLL IDM has excellent performance.

지뢰탐지용 48채널 배열 UWB 임펄스 레이더 방식 지면투과레이더시스템 개발 (Ground Penetrating Radar System for Landmine Detection Using 48 Channel UWB Impulse Radar)

  • 권지훈;곽노준;하성재;한승훈;윤여선;양동원
    • 전자공학회논문지
    • /
    • 제53권12호
    • /
    • pp.3-12
    • /
    • 2016
  • 본 논문은 지뢰탐지용 48채널 배열 UWB 임펄스 레이다 방식의 지면투과레이다 구현과 시험에 대해 기술한다. 지면투과레이더는 기존 금속탐지기의 한계인 비금속 지뢰 탐지의 어려움과 매질 내 금속 성분에 의해 발생하는 높은 오경보 문제점을 극복한다. 본 논문에서는 펄스폭이 600ps 급인 미세한 모노싸이클(Monocycle) 펄스 파형을 사용해, 높은 해상도의 지뢰 전자파 영상을 제공토록 시스템을 구현한다. 특히 신호처리를 통해 지뢰가 매설된 지점을 자동으로 추정하고, 해당 지점에서의 분할된 상세 지뢰 전자파 영상을 사용자에게 제공한다. 기준 성능 분석을 위해 한국 대표 토양인 거친 사양토를 사용한 실내 시험장을 구축하고, 시험장 내의 자동화된 측정 플랫폼에 구현한 레이다를 장착하여 영상 획득 및 탐지심도 분석 등의 시험을 수행한다. 지뢰는 비무장 지대에 매설된 지뢰와 동일한 형태의 모형 지뢰를 사용한다.

중요부하를 갖는 계통연계형 인버터의 고조파주입에 의한 단독운전방지 기법 (Anti-islanding Method by Harmonic Injection for Utility Interactive Inverter with Critical Load)

  • 오형민;최세완;김태희;이기풍;이태원
    • 전력전자학회논문지
    • /
    • 제17권4호
    • /
    • pp.315-321
    • /
    • 2012
  • The utility-interactive inverter with critical loads should supply continuous and stable voltage to critical loads even during the grid fault. The conventional control method which performs current control for grid-connected mode and voltage control for stand-alone mode undergoes the critical load voltage variation during grid fault. The critical load voltage may have large transient when the inverter performs mode transfer after the islanding detection. Recently, the indirect current control method which does not have the transient state during not only islanding detection but also the mode transfer has been proposed. However, since the voltage control is maintained even during the grid-connected mode it is difficult to detect the islanding. This paper proposes an active anti-islanding method suitable for the indirect current control method which does not have NDZ(Non-Detection Zone).