• 제목/요약/키워드: non-contact UV lamp system

검색결과 5건 처리시간 0.02초

국내하수처리장 자외선소독조 운영실태 및 기술동향 (WTP UV Disinfection System)

  • 이진영;김영태;이태제
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.126-132
    • /
    • 2005
  • UV disinfection system allows the disinfection of municipal and industrial water and wastewater without the use of expensive chlorination and dechlorination techniques, labor intensive equipments In traditional ultraviolet systems the UV lamps are seperated from water by quartz sleeves. quartz is one of. the few materials that is virtually transparent to UV light, the UV lamp is placed inside the Quartz sleeve. UV light from the lamp is passed through the quartz and into the water, thereby providing disinfection. In fluoropolymer tube-used non-contact UV systems, the water flows through fluoropolymer plastic tubes. banks of UV lamps surround these tubes such that each tube gets exposed to ultra violet light from all sides. in non-contact design the lamps operates at almost constant temperature. this design is extremly efficient in the utilization of UV energy and superior to conventional contact- systems.

  • PDF

비접촉식 자외선 반응조에서 자외선 강도 분포의 광학적 특성 (Optical characteristics of the UV intensity distribution in a non-contact type UV photoreactor)

  • 전화봉;윤정원;김성홍
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.257-264
    • /
    • 2012
  • The concept of a non-contact type of UV disinfection system was introduced in this study. UV lamps and their quartz sleeves hang over the water surface and there is no interface between the sleeve and water. Obviously, there is no fouling. Based on optical laws and other UV distribution models, a detail mathematical model for a non-contact type UV disinfection system was developed in this study. Pathway length of UV light in a non-contact type photoreactor is longer than that in a submerged type photoreactor because the light is more refractive while passing through 3 interfaces of medium. But the pathway length passing through the water media is not significantly longer than that in a submerged type photoreactor so, the absorption of UV light by water is not significantly different from the other system. Due to the reflection effect, UV intensity is rapidly decreased as the horizontal distance from the light source is increased. The reflective attenuation in a non-contact type photoreactor is higher than that in a submerged type photoreactor. These mean that the short photoreactor is advantageous than the narrow-long photoreactor for the non-contact type photoreactor in an optical point of view.

비접촉식 자외선램프를 이용한 살균/정화 수도꼭지 (A Water Tap Equipped with a Sterlization/Purification System of Non-contact UV-lamp)

  • 민경원;원종헌;이현철;한동열
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.3-7
    • /
    • 2007
  • Ultraviolet light(UV-C, wavelength: 200~280nm) is employed profitably for sterilizing drinking water. For most water serving apparatus such as a water purifier, a water cooler and heater, a coffee vending machine and etc., pre-sterilized water may be contaminated secondarily with bacillary inhabitation in a container before serving. In consideration of this problem, a household water tap which is equipped with a sterilization/Purification device in combination with non-contact UV-lamp, was designed to sterilize and purify water at the last outlet just before serving. Hopefully this simple but creative item may be commercialized for household and public use.

  • PDF

비접촉식 자외선 광반응조를 이용한 하수 대장균의 살균과 Log 불활성화율 지표 (Disinfection of E. coli from Wastewater using a Non-contact type UV Photoreactor and Log Inactivation Index)

  • 김성홍;김경면;김광일;최재완
    • 상하수도학회지
    • /
    • 제30권2호
    • /
    • pp.139-145
    • /
    • 2016
  • Disinfection of microorganisms using UV light is widely used in the field of water supply and wastewater treatment plant, In spite of high germicidal effect and relatively clean by-product, UV disinfection has fundamental defeat that is accumulation of fouling materials at the interface of water and lamp sleeve. Non-contact type of UV photoreactor which can avoid this fouling generation was developed and the experimental performance evaluation of the system was carried out in this study. Log inactivation rate of E. coli was selected as a disinfection index. The concentration of E. coli of second clarifier effluent was $8.2{\times}10^1-8.2{\times}10^3$ colony per mL and was well inactivated by the non-contact type of UV photoreactor. Under the UV intensity condition of $2.1-2.5mW/cm^2$, E. coli removal rate was observed in the range of 54 - 95% when the HRT was increased from 10 to 52 seconds. Experimental results showed that log inactivation of E. coli was proportional to UV dosage and $200mJ/cm^2$ of UV dose is expected for the 2.0 log inactivation of E. coli from the second clarifier effluent. Between the two parameters of UV intensity and contact time which are consist of UV dose, UV intensity was 4 times more effective than contact time.

Pulse UV 장치를 이용한 먹는 물의 이취미 유발물질 제거효과에 관한 연구 (Removal of taste and odor causing compounds in drinking water using Pulse UV System)

  • 손진식;박순호;정의택
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.219-228
    • /
    • 2012
  • Problems due to the taste and odor in drinking water are common in treatment facilities around the world. Taste and odor are perceived by the public as the primary indicators of the safely and acceptability of drinking water, and are mainly caused by the presence of two semi-volatile compounds-2-methylisoborneol(2-MIB) and geosmin. Conventional treatment processes in water treatment plants, such as coagulation, sedimentation and chlorination have been found to be ineffective for the removal of 2-MIB and geosmin. Pulse UV system is a new UV irradiation system that is a non-mercury lamp-based alternative to currently used continuous wave systems for water disinfection. This study shows pulse UV system to be effective in treatment of these two compounds. Geosmin removal efficiency of UV process alone achieved approximately 70% at 10sec contact time. 2-MIB removal efficiency of UV only process achieved approximately 60% at 10sec contact time. The addition of $H_{2}O_{2}$ 7mg/L increased geosmin and 2-MIB removal efficiency upto approximately 94% and 91%, respectively.