A Study on Wettability and Defects Behavior of Flow-soldered Joint using Low Residue Flux (저잔사 플럭스를 사용한 플로우 솔더링부의 젖음성 및 결함거동에 관한 연구)

  • 최명기;이창열;정재필;서창제;신영의
    • Journal of Welding and Joining
    • /
    • v.16 no.6
    • /
    • pp.77-85
    • /
    • 1998
  • Effects of non-cleaning and cleaning fluxes on the wetting properties and defects at flow soldered joints were investigated. Non-cleaning flux (R-type of 3.3% solid content) and cleaning flux (RMA-type of 15% solid content) were used. Wetting test was accomplished by wetting balance method with changing surface state of wetting specimen, CU. Sn-37%Pb solder was used for wetting test and flow soldering. As experimental results, the wetting time for vertical force from the surface tension being zero was mainly affected by surface state of the wetting specimen. Non-cleaning flux had a good wettability compared with cleaning flux. In case of non-cleaning flux, conveyor speed had a great affection to defects of bridge, icicle, and poor solder.

  • PDF

The Optimum Cleaning Process of Non-aqueous Alternative Solvents for 1,1,1-TCE (1,1,1-TCE에 대한 비수계성 대체세정제의 최적 세정공정)

  • Jung, Duck-Chae;Lee, Ki-Chang;Kong, Seung-Dae;Mok, Gab-Young;Lee, Seok-Woo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.16 no.3
    • /
    • pp.237-240
    • /
    • 1999
  • This study showed that the optimized cleaning process using non-aqueous cleaning solvents is adaptable in the industrial field for existing 1.1.1-TCE cleaning solvents which is an ozone depleting sustance. Alternative cleaning solvent system substituted for existing cleaning solvent against non-aqueous pollutants(cutting & flux oil), was evaluated for the cleaning efficiency using gravimetric analysis method and surface change of sample by Image analyzer. The results showed that alternative solvents and process had excellent cleaning efficiency.

Design and Development of Fluidized Bed Cleaning System for on Heat Treatment Parts (I) - Design and Development the Experimental Fluidized Bed Cleaner and Experiments on its Cleaning Efficiency - (유동층을 이용한 열처리부품의 세정 시스템 설계 및 개발 (I) -유동층 이용 세정 실험장치 설계, 개발 및 실험 -)

  • Kim C.S.;Kim K.D.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.4 s.117
    • /
    • pp.376-384
    • /
    • 2006
  • This study was conducted to perform for comparative analysis of the cleaning efficiency on 3 kinds of cleaning liquid state, 3 steps of cleaning temperature $(45^{\circ}C,\;60^{\circ}C,\;70^{\circ}C,\;)$ and 6 steps of cleaning time (2.5, 5, 7.5, 10, 12.5, 15 minute). 3 kinds of cleaning liquid state are the non fluidized bed, liquid fluidized bed and liquid/solid fluidized bed. UV spectrophotometer was used in estimation of cleaning efficiency, which it is experimental equipment using the absorptiometric analysis method. Cleaning efficiency by cleaning time was increase from 2.5 minutes to 15 minutes, liquid/siolid fluidized bed was indicated the highest cleaning efficiency among the 3 kinds of cleaning liquid state and $70^{\circ}C$ of cleaning temperature at liquid/solid fluidized bed was indicated the highest cleaning efficiency as 98% among the 3 steps of cleaning temperature.

Formulation of Alternative Non-Aqueous Cleaning Agents to Chlorofluorocarbon Compounds for Cleaning Flux, Solder and Grease (Flux, Solder 및 Grease 세정용 CFC 대체 비수계 세정제 배합 연구)

  • Jung, Young Woo;Lee, Ho Yeoul;Lee, Myoung Jin;Song, Ah Ram;Bae, Jae Heum
    • Clean Technology
    • /
    • v.12 no.4
    • /
    • pp.250-258
    • /
    • 2006
  • CFC compounds such as CFC-113 and 1,1,1-TCE, etc. have been used in various industries due to their excellent chemical stability, thermodynamic characteristics, non-inflammability and anti-corrosiveness. However, in oder to protect the earth environment, "the Montreal Protocol on substances that deplete the ozone layer" was adopted in 1989 for prevention of production and utilization of these CFC compounds and alternative cleaning agent have been required in the industry. The objective of this study is to develop non-aqueous cleaning agents that do not require major change of cleaning system, have excellent cleaning efficiency, are favorable to the environment, are harmless to the human body, and are not generated corrosive materials. In this work, non-aqueous cleaning agents have been formulated with glycol ether series and paraffinic hydrocarbon series with siloxane, and their physical properties and cleaning efficiencies were analyzed and compared with those of regulated materials. As a result of physical properties measurement of the formulated cleaning agents, it is expected that they may have good penetration ability into contaminated materials due to their properties with low density and low surface tension. Measurement of flash point and vapor pressure of the cleaning agents will be helpful for evaluation of their safety and working environment. The experimental results of cleaning flux, solder and grease by the formulated cleaning agents show that their cleaning abilities of soils were good and that there were no residues on the substance after cleaning. Therefore, alternative cleaning agents which have equivalent cleaning ability to regulating materials, good penetration ability and low hazard to human body, have been developed in this work.

  • PDF

Effect of Blast Cleaning on Fatigue Behavior of Non-load-carrying Fillet Welded Cruciform Joints (블라스트 표면처리가 하중비전달형 십자필렛 용접이음의 피로거동에 미치는 영향)

  • Kim, In Tae;Jung, Young Soo;Kim, Kwang Jin;Lee, Dong Uk
    • Journal of Korean Society of Steel Construction
    • /
    • v.21 no.1
    • /
    • pp.55-62
    • /
    • 2009
  • Blast cleaning has been applied in steel bridges for cleaning forged surface and increasing adhesive property of applied coating systems. Blasting is the operation of cleaning or preparing a surface by forcible propelling a stream of abrasive metals against it. Blast cleaning may improve surface geometry and induce compressive residual stress, and eventually may increase fatigue life of weld joints. In this paper, fatigue tests were carried out on three types of non-load-carrying fillet welded cruciform joints, as-welded joints, blast-treated joints, and stress-relieved joints after blasting, in order to investigate effect of blast cleaning on fatigue behavior of the weld joints. By Blast cleaning, the weld toe radius was increased by 29% and compressive residual stress was induced near weld toes. Blast cleaning increased fatigue life and fatigue endurance limit of the weld joints. When the applied stress ranges decreased, the increment in fatigue life became larger. About a 150% increase in fatigue limit could be realized by using blast cleaning.

Hydraulic Characteristics of the Non-power Soil Cleaning and Keeping System by the Large-Scale Model Test at the Dike Gate (배수문에서 실내모형실험에 의한 무동력 토사제거시스템의 수리 특성)

  • Park, Chan Keun;Oh, Beom Hwan;Lee, Dal Won
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.5
    • /
    • pp.67-75
    • /
    • 2014
  • In this study, the large-scale hydraulic model test was performed to investigate the hydraulic characteristics for development of the non-power soil cleaning and keeping system at the dike gate. The outlet height, outflow number, outflow discharge, and outflow cycle were compared and analyzed. The non-power soil cleaning and keeping system was most effective at 11.2 mm in the outlet height. And then the mean outflow cycle was 1.09 sec, and the mean outflow discharge was $0.00164m^3/s$. The total outflow number increased gradually as the water level of a water tank increased, and the outlet height decreased. As a level of water tank decreased, the mean outflow cycle was lengthened, and the unit outflow discharge increased. This result showed this system was most effective. To remove the silty clay deposited in facilities, the methods of excavation, dredging, high pressure washing, etc have been applied to the tidal facilities such as land reclamation, a small size fishing port, and a harbor for maintenance. However, this is extremely cost-ineffective, whereas the non-power soil cleaning and keeping system will bring about an enormously positive economic effect. In addition, when the non-power soil cleaning and keeping system is applied to the dike gate of land reclamation, a thorough examination of the local tidal data and the careful system planning are required to prevent the disaster damage caused by flooding.

A Study on the Cleaning Method of Excavated Textiles (의영 전의이씨 출토복식의 세척방법에 관한 연구)

  • 박윤미;황은경;정복남
    • The Research Journal of the Costume Culture
    • /
    • v.11 no.6
    • /
    • pp.956-966
    • /
    • 2003
  • The purpose of study is to find out a suitable cleaning method for excavated textiles of Jeon-ui Lee(1570∼1647). The textiles were excavated from her tomb in 1997, and her descendents put them in a box without any treatment and kept them in the warehouse since then. We used two kinds of silk as samples, non-dyed and dyed textile. The experiment was performed by 8 kinds of wet cleaning and dry cleaning methods, an ultrasonic cleaner was used in the wet cleaning, decane and perchloroethylene were used as solvents in the dry cleaning. The use of the ultrasonic cleaner in the wet cleaning method did not show any damage to the fibers of the textiles and it not only cleaned well but also was safe for the fugitive dyes. It resulted in more effective cleaning when the detergent was used together. Therefore, it is effective to use the ultrasonic cleaning on the delicate historical textiles and helpful to the operator's safety and environment.

  • PDF

Influence of access cavity design on calcium hydroxide removal using different cleaning protocols: a confocal laser scanning microscopy study

  • Seda Falakaloglu;Merve Yeniceri Ozata;Betul Gunes;Emmanuel Joao Nogueira Leal Silva;Mustafa Gundogar;Burcu Gucyetmez Topal
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.3
    • /
    • pp.25.1-25.13
    • /
    • 2023
  • Objectives: The purpose of this study was to evaluate the influence of endodontic access cavities design on the removal of calcium hydroxide medication of the apical third of mandibular incisor root canal walls and dentinal tubules with different cleaning protocols: EDDY sonic activation, Er,Cr:YSGG laser-activated irrigation, or conventional irrigation with IrriFlex. Materials and Methods: Seventy-eight extracted human mandibular incisors were assigned to 6 experimental groups (n = 13) according to the endodontic access cavity and cleaning protocol for calcium hydroxide removal: traditional access cavity (TradAC)/EDDY; ultraconservative access cavity performed in the incisal edge (UltraAC.Inc)/EDDY; TradAC/Er,Cr:YSGG; UltraAC. Inc/Er,Cr:YSGG; TradAC/IrriFlex; or UltraAC.Inc/IrriFlex. Confocal laser scanning microscopy images were used to measure the non-penetration percentage, maximum residual calcium hydroxide penetration depth, and penetration area at 2 and 4 mm from the apex. Data were statistically analyzed using Shapiro-Wilk and WRS2 package for 2-way comparison of non-normally distributed parameters (depth of penetration, area of penetration, and percentage of non-penetration) according to cavity and cleaning protocol with the significance level set at 5%. Results: The effect of cavity and cleaning protocol interactions on penetration depth, penetration area and non-penetration percentage was not found statistically significant at 2 and 4 mm levels (p > 0.05). Conclusions: The present study demonstrated that TradAC or UltraAC.Inc preparations with different cleaning protocols in extracted mandibular incisors did not influence the remaining calcium hydroxide at 2 and 4 mm from the apex.

Physical Properties and Cleaning Ability of New Cleaning Agents Based on 2,2,2-trifluoroethanol (TFEA) (2,2,2-trifluoroethanol (TFEA)를 기초로한 세정제의 물성 및 세정성 영향 연구)

  • Cha, An Jung;Park, Ji Na;Kim, Honggon;Bae, Jae Heum
    • Applied Chemistry for Engineering
    • /
    • v.16 no.4
    • /
    • pp.533-541
    • /
    • 2005
  • Non-aqueous cleaning agents were formulated with 2,2,2-trifluoroethanol (TFEA) and hydrofluoroether (HFE), and their physical properties and cleaning abilities were examined. TFEA-based aqueous cleaning agents were also formulated with nonionic surfactants, hydrotropes and builders, and their cleaning abilities were compared. Possibilities of these cleaning agents as substitutes for CFC-113 and 1,1,1-TCE were finally evaluated. In this work, fluxes, cutting oils, greases, and fluoric oils were selected as model contaminants for cleaning experiments. These contaminants have different properties of water-solubility or hydrophilicity, and fat-solubility or lypophilicity. Cleaning abilities of TFEA-based cleaning agents were analyzed and compared through the measurement of contaminant weight changes as a function of cleaning time, and their possibilities as alternative cleaning agents were evaluated. As a result, it was shown that TFEA and HFE-based non-aqueous cleaning agents have quite a good cleaning power for fluxes and fluorine soils but low one for greases. And TFEA-based agueous cleaning agents which consisted of nonionic surfactants, hydrotrope, and builders were very effective for cleaning fluxes and greases under certain formulation conditions. Thus, it was revealed that the TFEA-based cleaning agents were very effective for cleaning specific contaminants and can be used as substitutes for CFC-113 and 1,1,1-TCE in some industrial applications.