• Title/Summary/Keyword: non precious porcelain metal

Search Result 28, Processing Time 0.02 seconds

SEM/EDS Evaluation of Gold Bonding Agent Applied on Non-precious Alloys and Cast CP-Ti (도재 소부용 비귀금속 합금과 티타늄에 적용한 Gold Bonding Agent의 전자현미경적 평가)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of dental hygiene science
    • /
    • v.9 no.2
    • /
    • pp.153-160
    • /
    • 2009
  • The purposed of this study was to investigate the effect of Gold bonding agent as intermediate layer between metal substrate and ceramic coating. Gold bonding agent used to seal off any surface porosity, to mask the greyish color of the metal, and to provide an underlying bright golden hue to the ceramic coverage. The adhesion between metal substrate and ceramic is related to diffusion of oxygen during ceramic firing. The oxide layer produced on non-precious alloy anti titanium was considered to have a potentially adverse effect on metal-ceramic bonding. The oxidation characteristics of titanium and non-precious alloys are the main problem. Every group were divided into test and control groups. Control groups are carried out process of degassing for product oxide layer. Au coating was applied on each Ni-Cr, Co-Cr alloys and cp-Ti specimens with difference surface condition or degassing. Specimens surfaces and cutting plane was characterized by SEM/EDS. Results suggested that Au coating is effective barriers to protect metal oxidation during ceramic firing.

  • PDF

An Experimental Study on the Bond Strength after Surface Treatment of Non-precious Metal Alloy for porcelain Crown (도재용 비금속합금의 표면처리에 따른 결합강도에 관한 실험적 연구)

  • So, Myung-Sub
    • Journal of Technologic Dentistry
    • /
    • v.9 no.1
    • /
    • pp.39-49
    • /
    • 1987
  • This study done to evaluate some surface treatment methods in metal coping which can increase the bond strength between porcelain and metal. Therefore this experiment was performed according to the Mc Lean's Theory of bond strength between porcelain and strength between porcelain and metal. In the experiment the author measured respective thermal expansion coefficents in three types of metal(Tallasium, Vera Bond and Rexillium) and Vita Porcelain to get the differences in the coefficents between porcelain and metals. And using insteron testing machine, the author also performed Planar interface shear bond tests on the 45 specimens(15 specimens in oxide surface, rough surface and fine surface treatment methods respectively) to measure bond strength between metal and porcelain. The results Were as follows, 1. The differences in thermal expansion coefficients between three types of metal and Vita procelain: Talladium - $1.2\;10^{-6/0}\;C$, Vera Bond - $1.6\;10^{-6/0}\;C$, Rexillium - $1.9\;10^{-6/0}\;C$. 2. The bond strength in oxide surface on the Shear bond test was the lowest among the treatment methods. 3. There was no significant differences in treatment methods of rough surface of fine surface. 4. In the oxide surface treatment method, there were significant differences(P<0.05)between Vera bond and Rexillium, and between Talladium and Rexillium. 5. In the fine surface treatment, there was a significant difference(P<0.05)between Talladium and Rexillium.

  • PDF

The study of Shear Bond Strength on recasting of non-beryllium non-precious alloy for Porcelain between Metal (베릴륨이 포함되지 않은 도재용착주조관용 비 귀금속 합금의 재사용에 따른 금속과 도재간의 전단결합강도에 관한 연구)

  • Kim, So-Ri;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.35 no.1
    • /
    • pp.43-48
    • /
    • 2013
  • Purpose: This study aimed to investigate the shear bond strength for non-precious alloy castings without beryllium, which has been used repeatedly for economical reason. Methods: The Schmitz-Schulmeyer test method was used to evaluate the shear bond strength between the non-beryllium Ni-Cr alloy Vera Bond 2V(AlbaDent, Inc. USA) and the Ceramco 3(Dentstply, York, PA, USA) porcelain powder. The maximum loading and shear bond strength were measured. The average shear strength(MPa) was analyzed with the one-way ANOVA and the Tukey's test( =.05). The fracture specimens were examined using Microscope to determine the failure pattern. Results: The mean shear bond strengths(SD) in MPa were group A(100% new metal) control 28.72(3.31); group B(50% new + 50% reused) 27.28(1.13); group C(all reused) 26.61(5.47). Microscope examination showed that group A and B specimens presented mixed failure, and group C specimens showed adhesive failure. Conclusion: In conclusion, forward this non-precious alloy dose not contain beryllium for how should use a more systematic study and for future advanced research is performed giving effect to be considered desirable.

Corrosion of the non-beryllium dental casting Ni-Cr alloys for the denture base framework metal and the porcelain-fused-to-metal crown (베릴륨 불포함 치과 주조용 니켈-크롬 합금 중 금속의치상용 합금과 금속소부도재관용 합금의 부식에 관한연구)

  • Kim, Hong-Sik;Song, Jae-Sang;Park, Soo-Chul
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.337-344
    • /
    • 2012
  • Purpose: This study examined the corrosion level by alloy type and pH, and used the corrosion levels as the dental health data. The study utilized one Ni-Cr alloy for the full and removable partial denture metal frameworks and two Ni-Cr alloys for porcelain-fused-to-metal crown, among the non-beryllium dental casting non-precious Ni-Cr alloys. Methods: The alloy specimens were manufactured in $10cm^2$ and stored in the corrosive solution(pH 2.2-4.4) in the electrical water bath($37^{\circ}C$) for seven days. Afterwards, the metal ions were quantitatively analyzed using the ICP. Results: Of the three metal alloys, Bellabond-Plus$^{(R)}$alloy and SOLIBOND N$^{(R)}$alloy, with 22% or higher chrome chemical contents, had higher corrosion resistance than Jdium-100$^{(R)}$alloy with 20% chrome chemical content. In all three alloys, the corrosion of Ni was highest, and metal ion corrosion was higher in the pH 2.2 corrosive solution. Conclusion: Although Ni-Cr alloy was not very corrosive, a Ni-allergic patient should not have Ni-Cr alloy prosthesis. The Ni-Cr alloy for porcelain-fused-to-metal crown should be designed for the dental porcelain to cover the whole crown.

Effect of metal conditioner on bonding of porcelain to cobalt-chromium alloy

  • Minesaki, Yoshito;Murahara, Sadaaki;Kajihara, Yutaro;Takenouchi, Yoshihisa;Tanaka, Takuo;Suzuki, Shiro;Minami, Hiroyuki
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the efficacy of two different metal conditioners for non-precious metal alloys for the bonding of porcelain to a cobalt-chromium (Co-Cr) alloy. MATERIALS AND METHODS. Disk-shaped specimens ($2.5{\times}10.0mm$) were cast with Co-Cr alloy and used as adherend materials. The bonding surfaces were polished with a 600-grid silicon carbide paper and airborne-particle abraded using $110{\mu}m$ alumina particles. Bonding specimens were fabricated by applying and firing either of the metal conditioners on the airborne-particle abraded surface, followed by firing porcelain into 5 mm in diameter and 3 mm in height. Specimens without metal conditioner were also fabricated. Shear bond strength for each group (n=8) were measured and compared (${\alpha}=.05$). Sectional view of bonding interface was observed by SEM. EDS analysis was performed to determine the chemical elements of metal conditioners and to determine the failure modes after shear test. RESULTS. There were significant differences among three groups, and two metal conditioner-applied groups showed significantly higher values compared to the non-metal conditioner group. The SEM observation of the sectional view at bonding interface revealed loose contact at porcelain-alloy surface for non-metal conditioner group, however, close contact at both alloy-metal conditioner and metal conditioner-porcelain interfaces for both metal conditioner-applied groups. All the specimens showed mixed failures. EDS analysis showed that one metal conditioner was Si-based material, and another was Ti-based material. Si-based metal conditioner showed higher bond strengths compared to the Ti-based metal conditioner, but exhibited more porous failure surface failure. CONCLUSION. Based on the results of this study, it can be stated that the application of metal conditioner is recommended for the bonding of porcelain to cobalt-chromium alloys.

A Study on Bond Strength of Procelain with Non Precious Alloy (도재전장관용 비귀금속합금과 도재의 융착결합에 관한 연구)

  • Kang, Sung-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.49-57
    • /
    • 1980
  • The adhesive mechanisms on the metal-ceramic restorations have been reported to be mechanical interlocking, chemical bonding, compressive force, and Van der Waal's force, etc. Of these, the mechanical interlocking and chemical bonding forces are thought to affect the adhesive force between Ni-Cr alloy and porcelain. This study investigates the adhesion of Ni-Cr alloy to porcelain according to surface treatment. For this purpose, the following experiments were made; The compositions of Ni-Cr alloy as cast by emission spectrograph, and the oxides produced on Ni-Cr alloy during degassing at $1850^{\circ}F$ for 30 minutes in air and in vacuum were analyzed by X-ray diffractograph. The metal phases of Ni-Cr alloy were observed according to porcelain-baking cyclic heat treatment by photo microscope and the distribution and the shift of elements of Ni-Cr alloy and porcelain and the failure phases between Ni-Cr alloy and porcelain by scanning electron microscope. The adhesive force between Ni-Cr alloy and porcelain was measured according to surface treatment with oxidization and roughening by Instron Universal Testing Machine. Results were as follows; 1. The metal phases of Ni-Cr alloy as cast and degassing state showed the enlarged and fused core, but when subjected to porcelain-baking cyclic heat treatment, showed a dendrite growing. 2. The kinds of metal oxides produced on Ni-Cr alloy during degassing were found to be NiO and $Cr_2O_3$. 3. The distribution of elements at the interface of Ni-Cr alloy and porcelain in degassing state showed demarcation line, but in roughening state, showed mechanical interlocking phase. 4. The shift of elements at the interface occurred in both states, but the shift amount was found to be larger in roughening than in degassing. 5. The adhesive force between Ni-Cr alloy and porcelain was found to be $3.45{\pm}0.93kg/mm^2$, in degassing and $3.82{\pm}0.99kg/mm^2$, in roughening. 6. The failure phase between Ni-Cr alloy and porcelain showed the mixed type failure.

  • PDF

A Study on Satisfaction of Practicing Dentists about Prosthesis in Pusan Part I : About Fixed Prosthetic appliances (부산지역(釜山地域) 개업치과(開業齒科)의 치과보철물(齒科補綴物)에 관(關)한 만족도(滿足度) 조사(調査)(I) - 일부정식 치과 보철물에 관하여 -)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.159-169
    • /
    • 1988
  • Fixed prosthetic appliance is the restorations of damaged teeth with cast metal or porcelain, and of replacing missing teeth with fixed, or cemented prosthesis. Successfully treating a patient by means of fixed prosthodontics requires the thoughtful combination of dentist and dental laboratory technician. In order to know the satisfaction of dentisits about fixed prosthetic appliances-porcelain, precious and non precious metal-, this study was conducted for 69 practicing dentisis in Pusan during Fed. to Mar. 1988 using a questionnaire method and was analyzed by the use of percentage, $X^2$-test The results are obtained as follow: 1. General characteristics of the respondents, The rate of age distribution of practcing dentists responded was as follow : 31$\sim$35 age group is 29.0%, 51$\sim$55age group 18.8%, 41$\sim$45 age group and 46$\sim$50 group each 11.6%, 36$\sim$40 age group and 56$\sim$60 age group 8.7%, over 60 age group 7.3%, below 30 age group 4.3% respectively. The tate of term of practice experience distribution of dentists responded was as follow : 6$\sim$10 year group 26.1%, 25$\sim$25year group 18.8%, 11$\sim$15 years group and 16~20 years group each 13.0%, below 5 years group and over 30 years group each 10.2%, 26$\sim$30 years group 8.7% in order. The rate of respondents’ degree was follow : bachelor group 81.2%, doctor group 13.0%, master group 5.8% in order. The rate of respondents’completed medical specialist course was as follow : non-complete group 75.4%, complete group 24.6%. The rate of having own laboratory in respondents’clinic was as follow : no having own laboratory group 58.0%, having own labiratory group 42.0% The rate of being lab. technician in respondent;s clinic was as follow: non-being lab. technician group 91.3%, being lab. technician group 8.7%. The rate of transactional commercial dental lab. numbers was as follow : I dental lab. group 40.6%, 2 dental lab. group 30.4%, 3 dental lab. group 20.3%, production at own lab. group 8.7% 2. Cognitions about the respondent's job, About cognition of patient numvers, there were neither many nor few group 62.3%, few group 17.4%, many group 15.9%, too many group 4.4% in order.(P<.01) As compared with the ratio of dentists to patient prothetic treatment, there were moderate level group 46.4%, high level group 33.6%, low level group 18.8% in order.(P<.01) By job satisfaction of respondents, the highest percentage group was satisfied group 44.9%, neither astisfied nor disstified group 33.3%, dissatisfied group 14.5%, much satisfied group 7.3%(P<.01). As compared with the level of prosthetics price, the were moderate level group 71.0%, low level group 23.2%, high level group 5.8%(P<.01) 3. Satisfaction and assessment of dissatisfied factor of the fixed prosthetic appliance, As compared with the satisfaction of al prosthetic appliance, there were neither satisfied nor dissatisfied group 59.4%, satisfied group 20.3% dissatisfied group 18.8%, much satisfied group 1.5% in order.(P<.01). About precious and non precious metal crown and bridge, there were neither satisfied nor dissatisfied group 60.9%, satisfied group 24.6%, dissatisfied group 11.6%, much satisfied group 2.9% in order.(P<.01) The reat of respondent;s satisfaction about porcelain crown and bridge was as follow : neither satisfied nor dissatisfied group 43.5%, dissatisfied group 33.3%, satisfied group 21.7%, much satisfied group 1.5%(P<.01). The rate of respondent's dissatisfied factor item of precious and non precious metal crown and bridge was as follow : inadequate margin fit item 39.1% respondent, inadequate occlusion item 24.6%, inadequate adaptation item 23.2%, poor anat omic form item 15.9%, inadequate contact item 31.9%, improper polishing item 4.4%, the rest item 11.6% respectively. The rate of respondent's dissatisfied factor item of porcelain crown and bridge was as follow : inadequate margin fit item 52.2%, inadequate occlusion item 2.9%, inadequate adaptation item 10.1%, poor anatomic form item 11.6%, improper polishing item 1.5%, shade mismatching item 71%, the rest item 7.2% respectively. The rate of cognition of respondents’ about cause of dissatisfied factor on fixed prosthetic appliance by item was as follow : deficiency of sincerity item 55.1%, deficiency of knowledge about work item 47.8%, deficiency of experience item 15.9%, poor quality of using material item 5.8%, the rest item 2.9% respectively.

  • PDF

The Effect of Thickness of Porcelain on Shear Bond Strength Between Heat-Pressed Porcelain and Non-Precious Metal (도재의 두께가 하부금속과의 전단결합강도에 미치는 영향)

  • Jo, Jung-Min;Lee, Cheong-Hee;Lee, Kyu-Bok;Cho, Jin-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.223-232
    • /
    • 2012
  • The purpose of this study was to investigate the effect of various thickness of porcelain on shear bond strength between metal coping and porcelain. So, various thickness of feldspathic porcelain and heat-pressed porcelain were built up and compared. 120 metal cube($4{\times}4{\times}4mm$) specimens were prepared. 60 specimens were applied to feldspathic porcelain and the others were applied to heat-pressed porcelain by 1mm, 1.5mm, 2mm, 2.5mm, 3mm and 3.5mm thickness. The measurement of shear bond strength was performed by Instron universal testing machine. The following results were obtained from this study. 1. As thickness of feldspathic porcelain increases, shear bond strength has decreased. Feldspathic specimens with 1mm porcelain thickness were significantly stronger than other feldspathic subgroups. 2. There was no significant difference of shear bond strength according to porcelain thickness in heat-pressed porcelain group. 3. In comparison between subgroups with same thickness, feldspathic porcelain group had stronger shear bond strength than heat-pressed porcelain. There were significant difference between 1mm and 3mm porcelain thickness group. 4. In almost cases, fracture surface was found on both metal and porcelain surfaces. As thickness of porcelain was increased, metal exposure was decreased.

The Impacts of the Recasting of Non-precious Metal Alloy for Porcelain Fused to Metal Crowns on Strength (도재소부금관용 비귀금속 합금의 반복주조가 강도에 미치는 영향)

  • Chung, Hee-Sun;Oh, Gyung-Jae
    • Journal of Technologic Dentistry
    • /
    • v.31 no.3
    • /
    • pp.27-34
    • /
    • 2009
  • This study compared and analyzed changes to the mechanical characteristics to nonprecious metal alloy for porcelain fused to metal crowns when it's repetitively used without the addition of new alloy. Metal samples were made with the Verabond V nonprecious metal alloy. Those samples to measure tensile and yield strength were made in the standardized design(ISO 22674), those to measure bond strength in the $25mm{\times}3mm{\times}0.5mm$ format, and those to measure hardness in the $10mm{\times}10mm{\times}1mm$ format. A ceramic to measure bond strength was made at the center of the metal sample in the length of $8{\ss}{\AE}$ by using Noritaker Super Porcelain EX-3. Ten samples were prepared for one, three and five repetitions of casting each. The test results were as follows: 1. The more casting was repeated, the more significantly tensile strength dropped. 2. The more casting was repeated, the more significantly yield strength dropped. 3. Repetitive casting didn't cause significant changes to bond strength. 4. The Vickers hardness significantly fell with increasing repetitions of casting. There were no changes to bond strength observed with the increasing number of repeating casting. But tensile strength, yield strength, and Vickers hardness decreased. Those results indicate that repeated casting can affect durability and that careful attention should be paid by avoiding repetitive use or excessive increase of uses when no new alloy is added.

  • PDF

AN EXPERIMENTAL STUDY OF THE EFFECTS OF ION BEAM HIKING ON CERAMO-METAL BONDING (이온선 혼합법이 도재와 금속의 결합에 미치는 영향에 관한 실험적 연구)

  • Hong, Joon-Pow;Woo, Yi-Hyung;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.245-265
    • /
    • 1991
  • The purpose of this study was to observe the changes of the elemental transmission and bond strength between the metal and porcelain according to various kinds of ion beam mixing method. ion beam mixing of $meta1/SiO_2$ (silica), $meta1/Al_2O_3$(alumina) interfaces causes reactions when the $Ar^+$ was implanted into bilayer thin films using a 100KeV accelerator which was designed and constructed for this study. A vacuum evaporator used in the $10^{-5}-10^{-6}$ Torr vacuum states for the evaporation. For this study, three kinds of porcelain metal selected, -precious, semiprecious, and non-precious. Silica and alumina were deposited to the metal by the vacuum evaporator, separately. One group was treated by two kinds of dose of the ion beam mixing $(1\times10^{16}ions/cm^2,\;5\times10^{15}ions/cm^2)$, and the other group was not mixed, and analyzed the effects of ion beam mixing. The analyses of bond strength, elemental transmissions were performed by the electron spectroscopy of chemical analysis (ESCA), light and scanning electron microscope, scratch test, and micro Vickers hardness tests. The finding led to the following conclusions. 1. In the scanning electron and light microscopic views, ion beam mixed specimens showed the ion beam mixed indentation. 2. In the micro Vickers hardness and scratch tests, ion beam mixed specimens showed higher strength than that of non mixed specimens, however, nonprecious metal showed a little change in the bond strength between mixed and non mixed specimens. 3. In the scratch test, ion beam mixed specimens showed higher shear strength than that of non treated specimens at the precious and semiprecious groups. 4. In the ESCA analysis, Au-O and Au-Si compounds were formed and transmission of the Au peak was found ion beam mixed $SiO_2/Au$ specimen, simultaneously, in the higher and lower bonded areas, and ion beam mixed $SiO_2/Ni-Cr$ specimen, oxygen, that was transmitted from $SiO_2\;to\;SiO_2/Ni-Cr$ interface combined with 12% of Ni at the interface.

  • PDF