• Title/Summary/Keyword: nominal stress

Search Result 192, Processing Time 0.021 seconds

A Study on Reliability Based Design Criteria for Bridge Foundation (교량기초의 신뢰성 설계규준에 관한 연구)

  • 손용우;정철원
    • Computational Structural Engineering
    • /
    • v.6 no.1
    • /
    • pp.77-89
    • /
    • 1993
  • Current Bridge foundation design is based on Working Stress Design(WSD), but Load Factor Based on Optimum Reliability(LFBOR) design method is more rational than the WSD. For this reason, this study proposes a reliability based design criteria for the bridge foundation, which is most common type of bridge foundation(Shallow, Pile and Caission), and also proposes the theoretical basis of nominal safety factors of stability analysis by introducing the reliability theory. The limit state equations of stability analysis of bridge foundation and the uncertainty measuring algorithms of each equation are also derived by Cornell's MFOSM(Mean First Order 2nd Moment Methods)using the stability analysis fourmula Highway Bridge Design Codes.

  • PDF

EVALUATION ON THE FATIGUE STRENGTH OF SINGLE-SIDED WELDED JOINTS WITH CERAMIC BACKING MATERIAL

  • Kim Gwang-Seok;Kim Yu-Il;Jeon Yu-Cheol;Gang Jung-Gyu;Heo Ju-Ho;Lee Seong-Geun
    • Proceedings of the KWS Conference
    • /
    • 2004.05a
    • /
    • pp.255-257
    • /
    • 2004
  • This report presents S-N testing results of the butt and T-joint weldment which are produced by single sided welding with cenramic backing material. The specimen is designed in accordance with JISZ 3103 aid the test is peformed by the JSME S002. The nominal and hot spot stress based design S-N curves derived from fatigue tests are compared with the BS design curve. For butt and T-joint, it can be known that the double-sided butt welding process could be replaced by the single sided butt welding.

  • PDF

Verification on Damage Calculating Method of Vibration Fatigue Using Uni-axial Vibration Test (단축가진 시험을 통한 진동내구 손상도 계산)

  • Kim, Chan-Jung;Bae, Chul-Yong;Lee, Bong-Hyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.521-528
    • /
    • 2006
  • The vibration fatigue is suitable case of fatigue problem that system is exposed to the random or other irregular sources. Even some kinds of effort using power spectral density (PSD) and statistical concept was presented to cope with the intangible force signal, it is still lack of providing a reasonable solution when its exciting frequency is near or beyond of first eigenvalue. In this paper, energy approach method is presented to calculate a vibration induced fatigue damage in frequency domain. Since the corresponding damage become much larger than nominal case when the vibration is coupled with a mode shape of given structure, the new technique compensate the characteristics of structure with a measured frequency response function (FRF) between forcing acceleration and responding stress.

Torsional Analysis of RC Beam Using Average Strains (평균변형률을 이용한 RC보의 비틀림 해석)

  • Park, Chang-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.2
    • /
    • pp.157-165
    • /
    • 2002
  • Nonlinear analysis of the reinforced concrete beam subjected to torsion is presented. Seventeen equations involving seventeen variables are derived from the equilibrium equation, compatibility equation, and the material constitutive laws to solve the torsion problem. Newton method was used to solve the nonlinear simultaneous equations and efficient algorithms are proposed. Present model covers the behavior of reinforced concrete beam under pure torsion from service load range to ultimate stage. Tensile resistance of concrete after cracking is appropriately considered. The softened concrete truss model and the average stress-strain relations of concrete and steel are used. To verify the validity of present model, the nominal torsional moment strengths according to ACI-99 code and the ultimate torsional moment by present model are compared to experimental torsional strengths of 55 test specimens found in literature. The ultimate torsional moment strengths by the present model show good results.

A New High Efficiency and Low Profile On-Board DC/DC Converter for Digital Car Audio Amplifiers

  • Kim Chong-Eun;Han Sang-Kyoo;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.83-93
    • /
    • 2006
  • A new high efficiency and low profile on-board DC/DC converter for digital car audio amplifiers is proposed. The proposed converter shows low conduction loss due to the low voltage stress of the secondary diodes, a lack of DC magnetizing current for the transformer, and a lack of stored energy in the transformer. Moreover, since the primary MOSFETs are turned-on under zero-voltage-switching (ZVS) conditions and the secondary diodes are turned-off under zero-current-switching (ZCS) conditions, the proposed converter has minimized switching losses. In addition, the input filter can be minimized due to a continuous input current, and an output inductor is absent in the proposed converter. Therefore, the proposed converter has the desired features, high efficiency and low profile, for a viable power supply for digital car audio amplifiers. A 60W industrial sample of the proposed converter has been implemented for digital car audio amplifiers with a measured efficiency of $88.3\%$ at nominal input voltage.

Performance Analysis of ARCP Inverter for Power System Interconnection (ARCP(Auxiliary Resonant Commutated Pole) 인버터의 특성분석)

  • Ha, Yo-Chul;Park, Sang-Ho;Kim, Hee-Joong;Han, Byung-Moon;Kim, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1065-1067
    • /
    • 2000
  • This paper describes performance analysis of ARCP Inverter, which can offer zero voltage switching at nominal voltage stress. The system consists of a voltage-source inverter with sort-switching module. Each main switch is connected in parallel with resonant capacitor and two auxiliary switches are placed in series with a resonant reactor for soft-switching capability. The described ARCP inverter could be effectively applied for active power filter reactive power compensator, and UPS.

  • PDF

Development and Verification of Micro-indentation Technique for Material Property Evaluation of Hyper-elastic Rubber (초탄성고무 물성평가용 미소압입시험법 개발 및 검증)

  • Lee, Hyung-Il;Lee, Jin-Haeng
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.132-137
    • /
    • 2004
  • In this work, effects of hyper-elastic rubber material properties on the indentation load-deflection curve and subindenter deformation are first examined via [mite element (FE) analyses. An optimal data acquisition spot is selected, which features maximum strain energy density and negligible frictional effect. We then contrive two normalized functions. which map an indentation load vs. deflection curve into a strain energy density vs. first invariant curve. From the strain energy density vs. first invariant curve, we can extract the rubber material properties. This new spherical indentation approach produces the rubber material properties in a manner more effective than the common uniaxial tensile/compression tests. The indentation approach successfully measures the rubber material properties and the corresponding nominal stress.strain curve with an average error less than 3%.

  • PDF

Direct strength method for high strength steel welded section columns

  • Choi, Jong Yoon;Kwon, Young Bong
    • Steel and Composite Structures
    • /
    • v.29 no.4
    • /
    • pp.509-526
    • /
    • 2018
  • The direct strength method adopted by the AISI Standard and AS/NZS 4600 is an advanced design method meant to substitute the effective width method for the design of cold-formed steel structural members accounting for local instability of thin plate elements. It was proven that the design strength formula for the direct strength method could predict the ultimate strength of medium strength steel welded section compressive and flexural members with local buckling reasonably. This paper focuses on the modification of the direct strength formula for the application to high strength and high performance steel welded section columns which have the nominal yield stress higher than 460 MPa and undergo local buckling, overall buckling or their interaction. The resistance of high strength steel welded H and Box section columns calculated by the proposed direct strength formulae were validated by comparison with various compression test results, FE results, and predictions by existing specifications.

Structural Performance of 800 MPa High-Strength Steel Members and Application to Highrise and Mega Building Structures

  • Lee, Cheol-Ho
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.249-259
    • /
    • 2017
  • The use of high-strength steels in construction of highrise and mega building structures can bring about many technological advantages from fabrication to erection. However, key design criteria such as local and lateral stability in current steel design specifications were developed based on tests of ordinary steels which have stress-strain characteristics very different from that of high strength steels. A series of tests on 800 MPa tensile strength steel (HSA800) members are summarized in this paper which were conducted to investigate the appropriateness of extrapolating current ordinary-steel based design criteria to high strength steels. 800 MPa I-shape beam specimens designed according to flange local buckling (FLB) criteria of the AISC Specification developed a sufficient strength for elastic design and a marginal rotation capacity for plastic design. It is shown that, without introducing distinct and significant yield plateau to the stress-strain property of high-strength steel, it is inherently difficult to achieve a high rotation capacity even if all the current stability limits are met. 800 MPa I-shape beam specimens with both low and high warping rigidity exhibited sufficient lateral torsional buckling (LTB) strength. HSA800 short-column specimens with various edge restraint exhibited sufficient local buckling strength under uniform compression and generally outperformed ordinary steel specimens. The experimental P-M strength was much higher than the AISC nominal P-M strength. The measured residual stresses indicated that the impact of residual stress on inelastic buckling of high-strength steel is less. Cyclic seismic test results showed that HSA800 members have the potential to be used as non-ductile members or members with limited ductility demand in seismic load resisting systems. Finally, recent applications of 800 MPa high strength steel to highrise and mega building structures in Korea are briefly presented.

Local Buckling and Inelastic Behaviour of 800 MPa High-Strength Steel Beams (800MPa급 고강도강 보 부재의 국부좌굴 및 비탄성 거동)

  • Lee, Cheol-Ho;Han, Kyu-Hong;Kim, Dae-Kyung;Park, Chang-Hee;Kim, Jin-Ho;Lee, Seung-Eun;Ha, Tae-Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.4
    • /
    • pp.479-490
    • /
    • 2012
  • Flexural tests on full-scale H-shaped beams, built up from high-strength steels (HSB800 and HSA800) with a nominal tensile strength of 800 MPa, was carried out to study the effect of flange slenderness of high-strength steel on flexural strength and rotation capacity. The primary objective was to investigate the appropriateness of extrapolating current stability criteria (originally developed for ordinary steel) to high-strength steel. The performance of high-strength steel specimens was very satisfactory from the strength, but not from the rotation capacity, perspective. The inferior rotation capacity of high-strength steel beams was shown to be directly attributable to the absence of a distinct yield plateau and the high yield ratio of the material. Residual stress measurements reconfirmed that the magnitude of the residual stress is almost independent of the yield stress of the base metal.