• Title/Summary/Keyword: noise exposure

Search Result 523, Processing Time 0.027 seconds

A case report of embryo transfer with air-transported fresh bovine embryo produced by multiple ovulation in Hanwoo

  • Sang-Yup Lee;Seong-Eun Heo;Won-Jae Lee
    • Journal of Animal Reproduction and Biotechnology
    • /
    • v.38 no.2
    • /
    • pp.84-88
    • /
    • 2023
  • Because multiple ovulation embryo transfer (MOET) in cattle includes several benefits such as wide spreading of genetically superior offspring for long distance, this biotechnological method has been widely applied to Hanwoo. When the recipients are not stayed close after embryo recovery from donor, the embryos are moved to other farms via several vehicles (car, train, and airplane). However, air travel induces lesser oxygen level, increased vibration, lower air pressure, higher noise, and increased exposure of cosmic radiation to living things than ground level. It was still unknown that fresh embryos obtained from multiple ovulation of Hanwoo could maintain their fertility after being transported via air plane, the present case report introduced a clinical case of MOET in Hanwoo after shipping fresh embryos via air transportation. The donor was multi-ovulated via follicle-stimulating hormone series of injection, which was followed by a gonadotrophin-releasing hormone injection and artificial insemination twice. The embryos were recovered by the uterine flushing, packed in ministraws, transported to recipients for 6 h including 1 h air flight, and then transferred to the synchronized recipients. During pregnancy diagnosis of early gestation period, 5 of 7 recipients (71.4%) presented no heat signs and showed fetal sacs with fluid under transrectal ultrasonography. After normal gestation period, all recipients naturally delivered healthy calves (male n = 2 and female n = 3) without abortion, stillbirth, and premature birth. The present case report indicated that transportation of fresh embryos for MOET via domestic flight in Korea did not affect to their fertility.

Spam Image Detection Model based on Deep Learning for Improving Spam Filter

  • Seong-Guk Nam;Dong-Gun Lee;Yeong-Seok Seo
    • Journal of Information Processing Systems
    • /
    • v.19 no.3
    • /
    • pp.289-301
    • /
    • 2023
  • Due to the development and dissemination of modern technology, anyone can easily communicate using services such as social network service (SNS) through a personal computer (PC) or smartphone. The development of these technologies has caused many beneficial effects. At the same time, bad effects also occurred, one of which was the spam problem. Spam refers to unwanted or rejected information received by unspecified users. The continuous exposure of such information to service users creates inconvenience in the user's use of the service, and if filtering is not performed correctly, the quality of service deteriorates. Recently, spammers are creating more malicious spam by distorting the image of spam text so that optical character recognition (OCR)-based spam filters cannot easily detect it. Fortunately, the level of transformation of image spam circulated on social media is not serious yet. However, in the mail system, spammers (the person who sends spam) showed various modifications to the spam image for neutralizing OCR, and therefore, the same situation can happen with spam images on social media. Spammers have been shown to interfere with OCR reading through geometric transformations such as image distortion, noise addition, and blurring. Various techniques have been studied to filter image spam, but at the same time, methods of interfering with image spam identification using obfuscated images are also continuously developing. In this paper, we propose a deep learning-based spam image detection model to improve the existing OCR-based spam image detection performance and compensate for vulnerabilities. The proposed model extracts text features and image features from the image using four sub-models. First, the OCR-based text model extracts the text-related features, whether the image contains spam words, and the word embedding vector from the input image. Then, the convolution neural network-based image model extracts image obfuscation and image feature vectors from the input image. The extracted feature is determined whether it is a spam image by the final spam image classifier. As a result of evaluating the F1-score of the proposed model, the performance was about 14 points higher than the OCR-based spam image detection performance.

Development of an Occupational Safety and Health (OSH) Guide for Safely Cleaning Contaminated Machinery, Equipment, and Parts Used in the Electronics Manufacturing Process (전자산업 공정에서 사용한 부품, 기계류 세정(cleaning) 작업 안전보건 가이드)

  • Seunghee Lee;Soyeon Kim;Kyung Ehi Zoh;Yeong Woo Hwang;Kyong-Hui Lee;Kwang Jae Chung;Dong-Uk Park
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.419-426
    • /
    • 2023
  • Objectives: This study aims to develop an Occupational Safety and Health (OSH) guide for the safe cleaning of contaminated machinery, equipment, and parts used in the electronics manufacturing process. Methods: A literature review, field investigations, and discussions were conducted. An initial draft of an OSH guide was developed and reviewed by experts with significant experience in maintenance work in the electronics manufacturing process in order to refine the guide. Results: Workers involved in cleaning processes with chemicals, solvents, and abrasive blasting can face exposure to a wide range of chemicals, abrasives, and noise. Identifying potential risks associated with each cleaning technique was an essential first step toward enhancing safety measures. The OSH guide comprises approximately eleven to twelve sections spanning 20-25 pages. It includes engineering and administrative protocols systematically organized to address the necessary actions before, during, and after cleaning tasks, depending on the technique. It is recommended that airline respirator masks be used in conjunction with an air purification system to ensure adherence to air quality standard "D" for atmosphere level. The use of an oil-free air compressor is advised, preferably a stationary model that does not rely on fuel sources like diesel. Conclusions: This OSH guide is designed to protect workers involved in maintenance activity in the electronics industry and aligns with global standards, such as those from the International Organization for Standardization (ISO) and Semiconductor Equipment and Material International, ensuring a higher level of safety and compliance.

Analysis of the Relationships Between ESD and DAP, and Image SNR·CNR According to the Frame Change of Cine Imaging in CAG : With Focus on 10 f/s and 15 f/s (심장혈관 조영술에서 씨네(cine)촬영의 프레임변화에 따른 ESD와 DAP 및 영상의 SNR·CNR 관계 분석: 10f/s과 15f/s을 중심으로)

  • Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.669-675
    • /
    • 2018
  • This study aimed to investigate the difference of X-ray exposure by comparing and analyzing entrance surface dose and absorbed dose according to the frame change in coronary angiography using an X-ray machine. Moreover, appropriate frame selection measures for examination, including the effect of frame change on the image quality, were sought by measuring and analyzing the SNR and CNR of the image through image J. The study was conducted on 30 patients (19 males and 11 females) who underwent CAG at this hospital from June 2017 to October 2017. In regard to the patients, their age range was 49-82 years (mean of $65{\pm}9$ years), body weight was 45-91 kg (mean of $67{\pm}8.9kg$), height was 150-179cm (mean of $165.1{\pm}8.9kg$), and BMI was 19.5-30.5(mean of $24.5{\pm}2.9$). For the entrance surface dose and absorbed dose, air kerma value and DAP were obtained and analyzed retrospectively. The SNR and CNR were measured and analyzed through imageJ, and the result values were derived by applying the values to the formula. As for the statistical analyses, the correlations between the entrance surface dose and absorbed dose, and between the SNR and CNR were analyzed by using the SPSS statistical program. The relationship between the entrance surface dose and absorbed dose was not statistically significant for both 10 f/s and 15 f/s (p>0.05). In terms of the relationship between the SNR and CNR, the SNR ($3.374{\pm}2.1297$) and CNR ($0.234{\pm}0.2249$) in 10 f/s were $1.43{\pm}0.4861$ and $0.132{\pm}0.0555$ lower, respectively, than the SNR ($4.929{\pm}2.8532$) and CNR ($0.391{\pm}0.3025$) in 15 f/s, which were not statistically significant (p>0.05). In the correlation analysis, statistically significant results were obtained among the BMI, air kerma, and DAP; between air kerma and DAP; and between SNR and CNR (p<0.001, p<0.001). In conclusion, there was no significant difference between the entrance surface dose and absorbed dose even when the images were taken by changing the frame from 10 f/s to 15 f/s at the time of the coronary angiography. SNR and CNR increased at 15 f/s than at 10 f/s, but they were not statistically significant. Therefore, this study suggests that the concern of the patient and practitioner regarding image quality degradation, as well as the problem of X-ray exposure caused by imaging at 10 f/s and 15 f/s, may be reduced.

Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography (GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가)

  • Oh, Minju;Hong, Joo-Wan;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • In X-ray image, the role of filtration through the filter is to reduce the exposure of the patient by using photon which is useful in formation of the image, and at the same time, enhance the contrast of the image. During interaction between photon and object, low energy X-rays are absorbed from the site of a few cm of the first patient's tissue, and high energy X-rays are the one which form the image. Therefore, the radiation filter absorbs low energy X-ray in order to lower the exposure of the patient and improve the quality of the image. The purpose of this study is to compare the effect on the image quality by differences of added filter through simulation image and actual radiation image. For that purpose, we used Geant4 Application for Tomographic Emission (GATE) as a tool for Monte Carlo simulation. We set actual size, shape and material of Polymethylmethacrylate (PMMA) Phantom on GATE and differentiated the parameter of added filter. Also, we took image of PMMA phantom with same parameter of added filter by digital radiography (DR). Than we performed contrast-to-noise ratio (CNR) evaluation on both simulation image and actual DR image by Image J. Finally, we observed the effect on image quality due to different thickness of added filter, and compared two images' CNR evaluation's transitions of change. The result of this experiment showed decreasing in the progress of CNR on both DR and simulation image. It is ultimately caused by decreasing in contrast on image. In theory, contrast decrease with kVp increased. Given that condition, this study found out that filter makes not only decreasing total dose by absorbing low energy of X-ray, but also increasing average energy of X-ray.

Factors Related with Job Satisfaction in Workers - Through the Application of NIOSH Job Stress Model - (직장인의 직무만족도 관련요인 분석 - NIOSH의 직무스트레스 모형을 적용하여 -)

  • Kim, Soon-Lae;Lee, Bok-Im;Lee, Jong-Eun;Rhee, Kyung-Yong;Jung, Hye-Sun
    • Research in Community and Public Health Nursing
    • /
    • v.14 no.2
    • /
    • pp.190-199
    • /
    • 2003
  • This study was conducted to determine the factors affecting job satisfaction in workers by using the Job Stress Model proposed by the National Institute for Occupational Safety and Health (NIOSH). Data were collected from December 1 to December 30, 1999. The subjects were 2,133 workers employed at 155 work sites, who were examined using NIOSH Job Stress questionnaire translated by the Korea Occupational Safety ${\pounds}|$ Health Academy and Occupational Safety ${\pounds}|$ Health Research Institute. SAS/PC program was used for statistical analysis using descriptive analysis. Pearson's correlation coefficient, ANOVA, and Stepwise multiple regression analysis. The results of this study were as follows. 1. According to general characteristics of the subjects, job satisfaction was high in those with less number of children. 2. By work condition, job satisfaction was higher in those who were working in a permanent job position, were working with regular time basis than with shift basis, were working in regular shift hours than in changing shift hours, were working for a short period, and were working less hours and overtime works per week. 3. In terms of physical work environment, job satisfaction was significantly related to 10 physical environmental factors. In other words, job satisfaction was high in workers who were working in an environment with no noise, bright light, temperature adjusted to an appropriate level during summer and winter, humidity adjusted to an appropriate level. well ventilation, clean air, no exposure to hazardous substance during work hour, overall pleasant work environment and not crowded work space. 4. By work-related factors, job satisfaction was high in those with less ambiguity about future job and role, high job control/autonomy, and less workload. On the other hand, job satisfaction was low in those with little utilization of competencies, and much role conflict at work and workload. 5. As for the relationships between job satisfaction and the non-work related factors, job satisfaction was high in workers who were volunteering at different organizations or active in religious activities for 5-10 hours per week. 6. In the relationships between job satisfaction and buffering factors, significantly positive correlations were found between job satisfaction and factors such as support by direct superior, support by peers, and support by spouse, friend and family. 7. There were nine factors that affected job satisfaction in the workers: age, number of children, work hours per week, noise, temperature at the work site during summer, uncomfortable physical environment, role ambiguity, role conflict, ambiguity in job future, work load, no utilization of competencies and social support from direct supervisor. These nine factors accounted for 26% of the total variance in the multiple regression analysis. In conclusion. the following are proposed based on the results of this study. 1. The most important physical environmental factors affecting job satisfaction in workers were noise, role ambiguity, and work load, suggesting a need to develop strategies or programs to manage these factors at work sites. 2. A support system that could promote job satisfaction is needed by emphasizing the roles of occupational health nurses who may be stationed at work sites and manage the factors that could generate job stress. 3. Job satisfaction is one of the three acute responses to stress proposed in NIOSH job stress model (job satisfaction. physical discomfort and industrial accidents). Therefore, further studies need to be conducted on the other two issues.

  • PDF

The Study of Affecting Image Quality according to forward Scattering Dose used Additional Filter in Diagnostic Imaging System (부가필터 사용 시 전방 산란선량에 따른 화질 영향에 대한 연구)

  • Choi, Il-Hong;Kim, Kyo-Tae;Heo, Ye-Ji;Park, Hyong-Hu;Kang, Sang-Sik;Noh, Si-Cheol;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.597-602
    • /
    • 2016
  • Recent clinical field utilizes the aluminium filter in order to reduce the low-energy photons. However, the usage of the filter can cause adverse effect on the image quality because of the scattered dose that is generated by X-ray hardening phenomenon. Further, usage of filter with improper thickness can be a reason of dose creep phenomenon where unnecessary exposure is generated towards the patient. In this study, the author evaluated the RMS and the RSD analysis in order to have a quantitative evaluation for the effect of forward scattering dose by the filter on the image. as a result of the study, the FSR and the RSD was increased together with the increasing of thickness of the filter. In this study the RSD means the standard deviation of the mean value is relatively size. It can be understood that the signal-to-noise ratio decreases when the average value is taken as a signal and the standard deviation is judged as a noise. The signal-to-noise ratio can understanding as index of resolution at image. Based on these findings, it was quantitatively verified that there is a correlation of the image quality with the FSR by using an additional filter. The results, a 2.5 mmAl which is as recommended by NCRP in the tube voltage of 70 kVp or more showed the 14.6% on the RSD when the filter was not in used. these results are considered able to be utilized as basic data for the study about the filter to improve the quality of the image.

Reduction of Injection Dose in 18F-FDG Fusion PET (PET-CT 검사에서 18F-FDG 투여량 감소에 대한 고찰)

  • Kim, Jong-Pil;Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.17-21
    • /
    • 2014
  • Purpose With the recent rise of social issue regarding radiation exposure, attention to medical radiation use has been placed under a great spotlight. During PET-CT examination, generally about 40% more of $^{18}F$-FDG is used than EANM recommendation. While maintaining the diagnostic test result, we hope to find optimal injection dose to minimize the $^{18}F$-FDG in patients by utilizing the latest PET-CT scanner which is equiped with the newest technology. Materials and Methods During this experiment, the Biograph Truepoint 40 (siemens, USA) installed in 2007 and mCT 64 (siemens, USA) installed in 2011 were used and evaluated NECR (noise-equivalent counting rate) by using a scatter phantom. For the image quality evaluation of each scanner, we injected 3.7, 4.44 and 5.18 MBq/kg of $^{18}F$-FDG in NEMA IEC Body Phantom and also evaluated SNR between two scanners by using the data acquired at 60, 70, 80, 90, 100, 110 and 120 sec per bed. For the clinical evaluation, actual data of patients who were injected $^{18}F$-FDG 3.7, 4.44, 5.18 MBq/kg were used to compare SNR and draw a final result. Results As a result, mCT 64 peak NECR value was 1.65e+005, which is 10% higher than Turepoint 40. SNR values using the IEC body phantom was 17.9%, 17.4% and 17.1% higher in $^{18}F$-FDG 3.7 MBq/kg, 4.44 MBq/kg and 5.18 MBq/kg. In clinical patients, SNR values of the image mCT 64 was 16.5, which is 25% higher than Turepoint 40 scanner. Conclusion To draw a conclusion from the test result of this experiment, the same quality of SNR could be attained even with 10% reduced injection dose, if when the duration is extended by 10 sec/bed. This optimal result was possible due to enhanced equipment. The NECR (one of the equipment's performance assessment criteria for the scanner) increased by 10% and the SNR (one of the image quality assessment criteria) also increased by 17.5%. Therefore, we can expect to reduce the injection dose without deterioration of image quality. In consequence, it will also help to decrease the patient's anxiety of the radiation exposure.

  • PDF

Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method (PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과)

  • Jung, Seung Woo;Kim, Hong Kyun;Kwon, Jae Beom;Park, Sung Wook;Kim, Myeong Jun;Sin, Yeong Man;Kim, Yeong Heon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.127-133
    • /
    • 2014
  • Purpose: Low dose of PET/CT is important because of Patient's X-ray exposure. The aim of this study was to evaluate the effectiveness of low-dose PET/ CT image through the CTAC and QAC of patient study and phantom study. Materials and Methods: We used the discovery 710 PET/CT (GE). We used the NEMA IEC body phantom for evaluating the PET data corrected by ultra-low dose CT attenuation correction method and NU2-94 phantom for uniformity. After injection of 70.78 MBq and 22.2 MBq of 18 F-FDG were done to each of phantom, PET/CT scans were obtained. PET data were reconstructed by using of CTAC of which dose was for the diagnosis CT and Q. AC of which was only for attenuation correction. Quantitative analysis was performed by use of horizontal profile and vertical profile. Reference data which were corrected by CTAC were compared to PET data which was corrected by the ultra-low dose. The relative error was assessed. Patients with over weighted and normal weight also underwent a PET/CT scans according to low dose protocol and standard dose protocol. Relative error and signal to noise ratio of SUV were analyzed. Results: In the results of phantom test, phantom PET data were corrected by CTAC and Q.AC and they were compared each other. The relative error of Q.AC profile was been calculated, and it was shown in graph. In patient studies, PET data for overweight patient and normal weight patient were reconstructed by CTAC and Q.AC under routine dose and ultra-low dose. When routine dose was used, the relative error was small. When high dose was used, the result of overweight patient was effectively corrected by Q.AC. Conclusion: In phantom study, CTAC method with 80 kVp and 10 mA was resulted in bead hardening artifact. PET data corrected by ultra- low dose CTAC was not quantified, but those by the same dose were quantified properly. In patients' cases, PET data of over weighted patient could be quantified by Q.AC method. Its relative difference was not significant. Q.AC method was proper attenuation correction method when ultra-low dose was used. As a result, it is expected that Q.AC is a good method in order to reduce patient's exposure dose.

  • PDF

Effect of Glucose Level on Brain FDG-PET Images (FDG를 이용한 Brain PET에서 Glucose Level이 영상에 미치는 영향)

  • Kim, In-Yeong;Lee, Yong-ki;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.275-280
    • /
    • 2017
  • In addition to tumors, normal tissues, such as the brain and myocardium can intake $^{18}F$-FDG, and the amount of $^{18}F$-FDG intake by normal tissues can be altered by the surrounding environment. Therefore, a process is necessary during which the contrasts of the tumor and normal tissues can be enhanced. Thus, this study examines the effects of glucose levels on FDG PET images of brain tissues, which features high glucose activity at all times, in small animals. Micro PET scan was performed on fourteen mice after injecting $^{18}F$-FDG. The images were compared in relation to fasting. The findings showed that the mean SUV value w as 0.84 higher in fasted mice than in non-fasted mice. During observation, the images from non-fasted mice showed high accumulation in organs other than the brain with increased surrounding noise. In addition, compared to the non-fasted mice, the fasted mice showed higher early intake and curve increase. The findings of this study suggest that fasting is important in assessing brain functions in brain PET using $^{18}F$-FDG. Additional studies to investigate whether caffeine levels and other preprocessing items have an impact on the acquired images would contribute to reducing radiation exposure in patients.