• Title/Summary/Keyword: noise detecting equipment

Search Result 23, Processing Time 0.026 seconds

Detector Manufacture about Leaky Noise Generated from Faulty Power Equipment (불량 전력기기에서 발생하는 누설 노이즈 검출장치 제작)

  • Lee, Jong-Chan;Jeon, Yun-Jeon;Park, Ju-Hoo;Kim, Ki-Dae;Park, Hyung-Jun;Yoon, Yang-Woong;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1945-1947
    • /
    • 2000
  • In this paper, we manufactured the detector which is detecting the periodical distribution of arrival time about pulsed leaky noise. The frequency range were analyzed optimally pulsed leaky noise in detector design. With results we can make the detector for leaky noise from the bad insulator.

  • PDF

Noise Cancellation System Based on Frequency Domain Adaptive Filter Using Modified DFT Pair

  • Nakanishi, Isao;Nakamura, Youichi;Itoh, Yoshio;Fukui, Yutaka
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.225-228
    • /
    • 2000
  • It is well known that a Frequency Domain Adaptive Filter (FDAF) converges faster than a Time Domain Adaptive Filter (TDAF) even when the input signal is colored such as a speech signal. We have proposed the FDAF using the Modified Discrete Fourier Transform Pair (MDFTP) and its realization and effectiveness has been confirmed through the computer simulations. In this paper, we apply the FDAF using the MDFTP to the noise cancellation system. The proposed system is based on the Adaptive Line Enhancer (ALE) and utilizes single microphone; therefore it is suitable for the portable electronic equipment. Moreover, we propose to utilize the MDFT for detecting of the pitch in the speech because the number of data points in the MDFT must be equal to the pitch to confirmed that the noise can be removed to near the level of SNR.

  • PDF

A Study on a Post-Processing Technique for MBES Data to Improve Seafloor Topography Modeling (해저지형 모델링 향상을 위한 MBES자료 후처리 기법 연구)

  • Kim, Dong-Moon;Kim, Eung-Nam
    • Spatial Information Research
    • /
    • v.19 no.2
    • /
    • pp.19-28
    • /
    • 2011
  • Three dimensional modeling for seafloor topography is essential to monitoring displacements in underwater structures as well as all sorts of disasters along the shore. MBES is a system that is capable of high-density water depth measurement for seafloor topography and is in broad uses for gathering 3D data and detecting displacements. MBES data, however, contain random errors that take place in the equipment offset and surveying process and require systematic researches on the correction of wrong depth measurements. Thus this study set out to propose a post-processing technique to eliminate an array of random errors taking place after equipment offset correction and basic noise correction in the MBES system and analyze its applicability to seafloor topography modeling by applying it to the subject area.

A Study on the Algorithm for Detection of Partial Discharge in GIS Using the Wavelet Transform

  • J.S. Kang;S.M. Yeo;Kim, C.H.;R.K. Aggarwal
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.4
    • /
    • pp.214-221
    • /
    • 2003
  • In view of the fact that gas insulated switchgear (GIS) is an important piece of equipment in a substation, it is highly desirable to continuously monitor the state of equipment by measuring the partial discharge (PD) activity in a GIS, as PD is a symptom of an insulation weakness/breakdown. However, since the PD signal is relatively weak and the external noise makes detection of the PD signal difficult, it therefore requires careful attention in its detection. In this paper, the algorithm for detection of PD in the GIS using the wavelet transform (WT) is proposed. The WT provides a direct quantitative measure of the spectral content and dynamic spectrum in the time-frequency domain. The most appropriate mother wavelet for this application is the Daubechies 4 (db4) wavelet. 'db4', the most commonly applied mother wavelet in the power quality analysis, is very well suited to detecting high frequency signals of very short duration, such as those associated with the PD phenomenon. The proposed algorithm is based on utilizing the absolute sum value of coefficients, which are a combination of D1 (Detail 1) and D2 (Detail 2) in multiresolution signal decomposition (MSD) based on WT after noise elimination and normalization.

A Study on Detection of Broken Rotor Bars in Induction Motors Using Current Signature Analysis (전류신호를 이용한 유도전동기의 회전자봉 결함검출에 관한 연구)

  • 신대철;정병훈
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.4
    • /
    • pp.287-293
    • /
    • 2002
  • The unexpected failure of the induction motor makes the downtime of production, and the cost of the process cessation enormous. To reduce the downtime and increase the reliability of the motor, the vibration measurements for the fault detection have been used previously. Recently motor current signature analysis(MCSA) has been adapted for the fault detection and diagnosis of the motors. MCSA provides a powerful analysis tool for detecting the presence of mechanical and electrical faults in both the motor and driven equipment. In this paper, the fault severity of the rotor bar has been derived in terms of the resistance change which is calculated from the equivalent circuit model. Results show that the fault of the rotor can be easily detected and the measured value of the resistance change is verified by the detected fault from on-site tests using MCSA for the induction motors in an iron foundry.

Malfunction Detection of High Voltage Equipment Using Microphone Array and Infrared Thermal Imaging Camera (Microphone Array와 열화상 카메라를 이용한 고압설비 고장검출)

  • Han, Sun-Sin;Choi, Jae-Young;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • The paper proposes a hierarchical fault detection method for the high voltage equipment using a microphone array which detects the location of fault and the thermal imaging and CCD cameras which verifies the fault and stores the image, respectively. There are partial arc discharges on the faulty insulators, which generates a specific pattern of sound. Detecting the signal using the microphone array, the location of the faulty insulator can be estimated. The 6th band-pass filter was applied to remove noise signal from wind or external influence. When the mobile robot carries the thermal and CCD cameras to the possible place of the fault insulator, the fault insulators or power transmission wires can be detected by the thermal images, which are caused by the aging or natural erosion. Finally, the CCD camera captures the image of the fault insulator for the record. The detection scheme of fault location using the microphone array and the thermal images have been proved to be effective through the real experiments. As a result of this research, it becomes possible to use a mobile robot with the integrated sensors to detect the fault insulators instead of a human being.

A Study on the Detection Algorithm of an Advanced Ultrasonic Signal for Hydro-acoustic Releaser

  • Kim, Young-Jin;Huh, Kyung-Moo;Cho, Young-June
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.5
    • /
    • pp.767-775
    • /
    • 2008
  • Methods used for exploring marine resources and spaces include positioning a probe under water and then recalling it after a specified time. Hydro-acoustic Releasers are commonly used for positioning and retrieving of such exploration equipment. The most important factor in this kind of system is the reliability for recalling the instruments. The frequently used ultrasonic signal detection method can detect ultrasonic signals using a fixed comparator, but because of increased rates of errors due to outside interferences, information is repetitively acquired. This study presents an effective ultrasonic signal detection algorithm using the characteristics of a resonance and adaptive comparator Combined with the FSK+ASK modulator. As a result, approximately 8.8% of ultrasonic wave communication errors caused by background noise and transmission losses were reduced for effectively detecting ultrasonic waves. Furthermore, the resonance circuit's quality factor was enhanced (Q = 120 to 160). As such, the bias voltage of the transistor (Vb= 3.3 to 6.8V) was increased thereby enhancing the frequency's selectivity.

Construction and roles of computer simulator for digital controller design

  • Nakamura, Masatoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.909-914
    • /
    • 1988
  • The structure of a digital controller based on modern control theory is more complex than that of a PID controller. In implementing the digital control of an actual system by using the digital controller, we often encounter gaps between theory and practice e.g. quantization error, sampling error, modeling error, contaminated noise etc. In such cases, simulator plays an important role in detecting difficulties. This paper demonstrates the importance of the computer simulator for designing a digital controller. The controller and the simulator are constructed by different computer respectively, with a link between the blocks by analogue signals through the A/D, D/A converters. Through the simulator test, we can evaluate the digital controller; identify and solve difficulties in the digital control. The controller, which pasted the simulator test, is used identically in the actual system. This was a successful procedure for designing the controller. As an example, we successfully constructed the digital controller using the computer simulator for inverted pendulum control. We then compared the control results of simulator and actual equipment. Furthermore we commented on the construction of the computer simulator which exactly expressed the actual system.

  • PDF

A Study on Alignment Correction Algorithm for Detecting Specific Areas of Video Images (영상 이미지의 특정 영역 검출을 위한 정렬 보정 알고리즘 연구)

  • Jin, Go-Whan
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.11
    • /
    • pp.9-14
    • /
    • 2018
  • The vision system is a device for acquiring images and analyzing and discriminating inspection areas. Demand for use in the automation process has increased, and the introduction of a vision-based inspection system has emerged as a very important issue. These vision systems are used for everyday life and used as inspection equipment in production processes. Image processing technology is actively being studied. However, there is little research on the area definition for extracting objects such as character recognition or semiconductor packages. In this paper, define a region of interest and perform edge extraction to prevent the user from judging noise as an edge. We propose a noise-robust alignment correction model that can extract the edge of a region to be inspected using the distribution of edges in a specific region even if noise exists in the image. Through the proposed model, it is expected that the product production efficiency will be improved if it is applied to production field such as character recognition of tire or inspection of semiconductor packages.

Kalman Filter Estimation of the Servo Valve Effective Orifice Area for a Auxiliary Power Unit (보조 동력장치용 서보밸브 유효 오리피스 면적의 칼만필터 추정)

  • Zhang, J.F.;Kim, C.T.;Jeong, H.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.4 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Flow rate is one of the important variables for precise motion control and detection of the faults and fluid loss in many hydraulic components and systems. But in many cases, it is not easy to measure it directly. The orifice area of a servo valve by which the fluid flows is one of key factors to monitor the flow rate. In this paper, we have constructed an estimation algorithm for the effective orifice area by using the model of a servo valve cylinder control system and Kalman filter algorithm. Without geometry information about the servo valve, it is shown that the effective orifice area can be estimated by using only displacement and pressure data corrupted with noise. And the effect of the biased sensor data and system parameter errors on the estimation results are discussed. The paper reveals that sensor calibration is important in accurate estimation and plausible parameter data such as oil bulk modulus and actuator volume are acceptable for the estimation without any error. The estimation algorithm can be used as an useful tool for detecting leakage, monitoring malfunction and/or degradation of the system performance.

  • PDF