• Title/Summary/Keyword: noise absorbing

Search Result 215, Processing Time 0.019 seconds

A Study on the Absorption Characteristics of Absorbents in Duct System with the Air Cavity (공기층을 갖는 공조덕트 구조물에서 흡음재의 흡음특성에 관한 연구)

  • 김찬묵;김도연;방극호
    • Journal of KSNVE
    • /
    • v.10 no.5
    • /
    • pp.892-897
    • /
    • 2000
  • In this paper, experimental methods to find acoustic characteristics of acoustically treated air-conditioning duct system are proposed. Existing methods to analyze acoustic properties of duct with absorbent material have dilemma which has to assume the wave in duct to be a plane wave. Under this assumption. applicable frequency limitation makes accurate analysis of practical air-conditioning system impossible. In order to analyze the properties of in-lined treated absorbent with high degree of accuracy, in this experiments the range of exciting frequency of sound source is broadband, which means that source speaker excited higher mode of in-duct sound field. Also, to define the relations of air cavity to the acoustic characteristics, acoustic experiments on ducts with air cavity of different depth are operated. In conclusion, air-cavity makes the absorbing ability of duct improved in low frequency range. Due to the interactions between the air cavity depth and the depth of absorbents, according to depth of cavity, the magnitude of absorption coefficients vs frequencies in specific range is changed. In lower frequency range, the absorption of sound energy by air cavity is more dominant than by absorbent itself, in higher range, the inversion is true.

  • PDF

An Investigation of the Regulation, Design and Improvement of Domestic and International Ambulances (국내·외 구급차 규정, 디자인 및 개선에 관한 조사연구)

  • Shin, Dong-Min;Kim, Seung-Yong;Han, Yong-Taek
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.172-179
    • /
    • 2014
  • This research suggests that the regulation, design and improvement of domestic and international ambulances so that make the basis for the future ambulance in Korea. It is true that the diversification of current disasters, increasing elderly population, the increase in emergency patients, due to the lack of effective transfer system, emergency vehicle's performance problem, and the aging of ambulances cause have difficulty in providing effective emergency services in domestic country. Therefore, in order to improve the effectiveness of ambulance, the history of ambulance, other relevant provisions include international, design and directions to be improved were investigated, and also research directions of the ambulance are suggested in domestic country. In this research, suggests the following conclusions to improve domestic ambulance 1. Through standardization of the spacing and location of an ambulance is needed to maximize the treatment room. 2. The interior of the ambulance design for hygiene and infection control should be included. 3. Stretcher and equipment are designed to be fitted to each other should be standardized. 4. Especially during transfer maintain the road, noise, vibration, and shock-absorbing function to emphasize the importance. 5. The improvement of ergonomic design is necessary for the possibility of applying to many people.

Effects of Phenotypic Variation on Evolutionary Dynamics

  • Kang, Yung-Gyung;Park, Jeong-Man
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1774-1786
    • /
    • 2018
  • Phenotypic variation among clones (individuals with identical genes, i.e. isogenic individuals) has been recognized both theoretically and experimentally. We investigate the effects of phenotypic variation on evolutionary dynamics of a population. In a population, the individuals are assumed to be haploid with two genotypes : one genotype shows phenotypic variation and the other does not. We use an individual-based Moran model in which the individuals reproduce according to their fitness values and die at random. The evolutionary dynamics of an individual-based model is formulated in terms of a master equation and is approximated as the Fokker-Planck equation (FPE) and the coupled non-linear stochastic differential equations (SDEs) with multiplicative noise. We first analyze the deterministic part of the SDEs to obtain the fixed points and determine the stability of each fixed point. We find that there is a discrete phase transition in the population distribution when the probability of reproducing the fitter individual is equal to the critical value determined by the stability of the fixed points. Next, we take demographic stochasticity into account and analyze the FPE by eliminating the fast variable to reduce the coupled two-variable FPE to the single-variable FPE. We derive a quasi-stationary distribution of the reduced FPE and predict the fixation probabilities and the mean fixation times to absorbing states. We also carry out numerical simulations in the form of the Gillespie algorithm and find that the results of simulations are consistent with the analytic predictions.

A Study on the User Needs for Renovation of Race Track Type of Nursing Units in K University Hospital (K대학병원 병동부 이중복도형의 개선을 위한 사용자 요구 조사연구)

  • Kim, Youngaee;Yim, Ohyon;Kim, Jungshin;Yi, Jongse;Ahn, Uijong
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.19 no.3
    • /
    • pp.21-28
    • /
    • 2013
  • Purpose: General hospital in korea is getting large-scaled, specialized and upgraded. So, nursing unit of race track type has been advanced along with a spatial organization, building equipment and environmental approach. This study is to search the guidelines for renovation of nursing unit with race track type in the case of K university hospital in Daejeon. Methods: 9 cases of recently opened general hospital has been analyzed for spatial and environmental design solution. Questionnaires and interviews about user needs of nursing staff, patient and visitors, have been conducted for a nursing care system and facility of nursing units in K university hospital. Results: The user needs are represented as followings. Center core public zone in each floor plan and center core nursing station and supporting areas in nursing unit are good for an adjacency and separation of spatial organization. Toilet of group patient room is necessary to equip for easy, safe and infective aspects, and so toilet install will decrease the patient number and increase the nursing care service. Hall type of station front is good for visibility and observation. It is appropriate to renovate into south facing group patient room for privacy, enough space for nursing care facility and supporting area, enough width of door to move portable medical equipment, room for medical doctor and practical student, noise absorbing of day room. Implications: Upgrading the nursing care service and facility equipment is necessary to reflect the user needs and cooperate with hospital management.

Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography (GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가)

  • Oh, Minju;Hong, Joo-Wan;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • In X-ray image, the role of filtration through the filter is to reduce the exposure of the patient by using photon which is useful in formation of the image, and at the same time, enhance the contrast of the image. During interaction between photon and object, low energy X-rays are absorbed from the site of a few cm of the first patient's tissue, and high energy X-rays are the one which form the image. Therefore, the radiation filter absorbs low energy X-ray in order to lower the exposure of the patient and improve the quality of the image. The purpose of this study is to compare the effect on the image quality by differences of added filter through simulation image and actual radiation image. For that purpose, we used Geant4 Application for Tomographic Emission (GATE) as a tool for Monte Carlo simulation. We set actual size, shape and material of Polymethylmethacrylate (PMMA) Phantom on GATE and differentiated the parameter of added filter. Also, we took image of PMMA phantom with same parameter of added filter by digital radiography (DR). Than we performed contrast-to-noise ratio (CNR) evaluation on both simulation image and actual DR image by Image J. Finally, we observed the effect on image quality due to different thickness of added filter, and compared two images' CNR evaluation's transitions of change. The result of this experiment showed decreasing in the progress of CNR on both DR and simulation image. It is ultimately caused by decreasing in contrast on image. In theory, contrast decrease with kVp increased. Given that condition, this study found out that filter makes not only decreasing total dose by absorbing low energy of X-ray, but also increasing average energy of X-ray.