• 제목/요약/키워드: no-tension materials

Search Result 75, Processing Time 0.029 seconds

Mechanical and interfacial characterization of laser welded Co-Cr alloy with different joint configurations

  • Kokolis, John;Chakmakchi, Makdad;Theocharopoulos, Antonios;Prombonas, Anthony;Zinelis, Spiros
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • PURPOSE. The mechanical and interfacial characterization of laser welded Co-Cr alloy with two different joint designs. MATERIALS AND METHODS. Dumbbell cast specimens (n=30) were divided into 3 groups (R, I, K, n=10). Group R consisted of intact specimens, group I of specimens sectioned with a straight cut, and group K of specimens with a $45^{\circ}$ bevel made at the one welding edge. The microstructure and the elemental distributions of alloy and welding regions were examined by an SEM/EDX analysis and then specimens were loaded in tension up to fracture. The tensile strength (TS) and elongation (${\varepsilon}$) were determined and statistically compared among groups employing 1-way ANOVA, SNK multiple comparison test (${\alpha}$=.05) and Weibull analysis where Weibull modulus m and characteristic strength ${\sigma}_0$ were identified. Fractured surfaces were imaged by a SEM. RESULTS. SEM/EDX analysis showed that cast alloy consists of two phases with differences in mean atomic number contrast, while no mean atomic number was identified for welded regions. EDX analysis revealed an increased Cr and Mo content at the alloy-joint interface. All mechanical properties of group I (TS, ${\varepsilon}$, m and ${\sigma}_0$) were found inferior to R while group K showed intermediated values without significant differences to R and I, apart from elongation with group R. The fractured surfaces of all groups showed extensive dendritic pattern although with a finer structure in the case of welded groups. CONCLUSION. The K shape joint configuration should be preferred over the I, as it demonstrates improved mechanical strength and survival probability.

Open Reduction of Proximal Interphalangeal Fracture-Dislocation through a Midlateral Incision Using Absorbable Suture Materials

  • Lee, Jae Jun;Park, Hyoung Joon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.397-402
    • /
    • 2013
  • Background Fracture-dislocation of the proximal interphalangeal (PIP) joint is a relatively common injury. Various treatments for fracture-dislocation of the PIP joint have been reported. In the present study, we performed open reduction through a midlateral incision using absorbable sutures to reduce the small bone fragments and performed volar plate repair. Methods We treated nine patients with fracture-dislocation of the PIP joint with small fractured bone fragments too small for pinning or screw fixation. Patients with volar plate injury were treated with open reduction and volar plate repair at the periosteum of the middle phalangeal bone base by the modified Kessler method using absorbable sutures. All patients were placed in a dorsal aluminum extension block splint, which maintained the PIP joint in approximately 30 degrees of flexion to avoid excessive tension on the sutured volar plate. Results At a mean final follow-up of postoperative 9 months, all patients were evaluated radiographically and had adequate alignment of the PIP joint and reduction of the displaced bone fragments. Range of motion was improved and there were no complications. Conclusions This technique is an excellent alternative to the current method of treating patients with fracture-dislocations that include small fragments that are too small for pinning or screw fixation. It is a less invasive surgical method and enables stable reduction and early exercise without noticeable complications.

Finger Injury by Green Onion Cutting Machine (파절기에 의한 수지손상)

  • Yim, Young Min;Oh, Deuk Young;Jung, Sung No;Rhie, Jong Won;Ahn, Sang Tae;Kwon, Ho
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.46-50
    • /
    • 2009
  • Purpose: Finger injury by green onion cutting machine is one of the common hand injuries in the kitchen. It has a unique feature: there are multiple parellel laceration 3 - 5 mm wide. There are two directions of injuries(vertical, oblique). It may involve bone, tendon, nerve, and vessel injuries. We discuss its management and the long - term progress. Methods: We have treated six patients from 2003 to 2007. We carried out low tension approximation with thin suture materials to avoid ischemia and performed the additional operation as nail bed repair, tenorrhaphy, open reduction, vessel anastomosis, and composite graft. We reviewed the record of initial injury and collected the follow - up record. Results: They were all middle aged - women who had worked in the kitchen. Right hand was dominent over left hand. The ratio of the directions was 3 : 3 (vertical : oblique). They were all competely healed although there were three atrophy, four hyperesthesia, and one nail deformity. Conclusion: Finger injury by green onion cutting machine is a unique pattern of laceration with various accompanied injuries. It may look like a severe form of injury, but in most cases have relatively favorable progress. We have to perform careful examination of accompanied injuries and carry out the proper management. First and foremost, the user especially in the middle aged women should be warned to be careful in handling this risky machine.

Convenient Suture Technique for Pediatric Facial Lacerations (소아 안면열상 환자의 치료에 있어서 유용한 봉합술)

  • Kim, Jun-Hyung;Kwon, Soon-Beom;Eo, Su-Rak;Cho, Sang-Hun;Markowitz, Bernard L.
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.496-498
    • /
    • 2010
  • Purpose: Lacerations requiring formal wound closure compose a significant number of all childhood injuries presenting to the emergency department. The problem with conventional suture technique are that suture removal is quite cumbersome, especially in children. Unwanted soft tissue damage can result in the process of suture removal, which calls for sedation, stressful for both medical personnel and child. The purpose of this study is to introduce the convenient suture technique for pediatric facial lacerations. Methods: Children under the age of four, presenting to the emergency department with facial lacerations were enrolled in the study. From March 2008 to June 2009, 63 patients (41 males and 22 females) with an average age of 1.4 years were treated with our convenient suture technique using utilized a loop suspended above a double, flat tie. Clean, tension free wounds were treated with our technique, wounds with significant skin defect and concomitant fractures were excluded. Results: The Patients were followed-up in 1, 3 and 5 days postoperatively. On the third hospital visit, suture removal was done by simply cutting the loop suspended above the wound margin and gently pulling the thread with forceps. There were no significant differences in the rates of infection and dehiscence compared with conventional suture technique. Conclusion: The use of our technique was to be simple with similar operative time compared with conventional suture technique. Removal of suture materials were easy without unwanted injuries to the surrounding tissue which resulted in less discomfort for the patient and greater parental satisfaction, minimized the complications. It can be considered as a viable alternative in the repair of pediatric facial lacerations.

Usefulness of Vocal Fatigue Index for Hypertension of Extrinsic Laryngeal Muscles (후두외근 과긴장에 대한 음성피로도 검사의 유용성)

  • Kim, Ji-Sung;Lee, Dong-Wook
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.32 no.3
    • /
    • pp.124-129
    • /
    • 2021
  • Background and Objectives This study compares Vocal Fatigue Index (VFI) scores according to the presence or absence of external laryngeal tension in hyperfunctional voice disorder. And through this, it is to confirm the usefulness of VFI to hypertension of extrinsic laryngeal muscles. Materials and Method The subjects were 61 female diagnosed with hyperfunctional voice disorder (hypertension group 41, non-hypertension group 20). The author palpated extrinsic laryngeal muscles for evaluation of hypertension and classified them as the presence or absence. The voice measurements were jitter, shimmer, Korean-Voice Handicap Index-10 (K-VHI-10), and Korean-Vocal Fatigue Index (K-VFI). The voice compared were according to the diagnosis and presence of hypertension only for patients with hyperfunctional voice disorder. Results As a result of comparing the voice measurement according to the presence or absence of hypertension, there was no significant difference in the acoustic variables, K-VHI-10 and K-VFI-Total, K-VFI-Fatigue. Whereas, K-VFI-Physical (p=0.006) and K-VFI-Rest (p=0.022) were significantly higher in the hypertension group. Conclusion These results indicate that the hypertension group has more physical discomfort and less voice recovery than the group without hypertension. It means that K-VFI can measure the physical discomfort and limitations of voice recovery due to hypertension of the external laryngeal muscle. The VFI can be used as one of the methods to evaluate the hypertension of the external laryngeal muscle in Hyperfunctional voice disorder.

Measurement of the Grafts for the Anterior Cruciate Ligament Reconstruction with Tension Load Technique and Achilles Tendon Autograft using Postoperative Magnetic Resonance Imaging (자가 아킬레스 건과 장력 부하 기법을 이용한 전방십자인대 재건술 후 자기 공명 영상을 이용한 이식건의 평가)

  • Seo, Jai-Gon;Moon, Young-Wan;Yoo, Jae-Chul;Chang, Moon-Jong;Kim, Seung-Yeon;Kim, Mu-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • Purpose: To evaluate the postoperative magnetic resonance image (MRI) findings of anterior cruciate ligament (ACL) reconstructed with a tension load technique using auto-Achilles tendon, and to compare the results with knees with a native ACL. Materials and Methods: We evaluated 21 postoperative MRI scan of 21 patients (group A) who had undergone ACL reconstruction between January 1995 and November 1996. The control group (group B) consisted of 50 patients whose meniscus tear had been operated by arthroscopy and whose ACL was intact. We measured the orientation of the graft in the sagittal and coronal planes and compared it with that of the native ACL. Results: The mean sagittal angle of the ACL angle in group A ($55.7{\pm}5.6^{\circ}$, range $47.2{\sim}68.8^{\circ}$) was statistically lesser than group B ($58.7{\pm}3.8^{\circ}$, range $50.4{\sim}67.5^{\circ}$) (p=0.036). But there was no statistically significant difference between the two groups with regard to the mean ACL-Blumensaat line angle (group A: $8.1^{\circ}{\pm}4.9^{\circ}$, range $1.7^{\circ}{\sim}22.0^{\circ}$, group B: $8.6^{\circ}{\pm}3.6^{\circ}$, range $2.6^{\circ}-18.1^{\circ}$) and the mean coronal angle of the ACL (group A: $64.9^{\circ}{\pm}9.1^{\circ}$, range $46.9^{\circ}{\sim}76.4^{\circ}$, group B: $65.9^{\circ}{\pm}4.4^{\circ}$, range $57.7^{\circ}{\sim}75.2^{\circ}$)(p=0.88, p= 0.62). In the sagittal plane, the mean center of tibial insertion of the ACL graft in group A ($31.9{\pm}7.1%$, range 22.4-47.9%) was positioned more anteriorly than group B ($37.0{\pm}4.9%$, range $18.5{\sim}44.7%$)(p=0.005). But in the coronal plane, there was no statistically significant difference between the two groups(group A: $46.3{\pm}2.8%$, range $42.1{\sim}52.5%$, group B: $45.7{\pm}2.8%$, range $41.0{\sim}49.1%$)(p=0.392). Conclusion: We performed an ACL reconstruction with the tension load technique using auto-Achilles tendon and we found that the graft orientation in MRI was as good as that of the native ACL.

  • PDF

Effect of mechanical surface treatment on the fracture resistance and interfacial bonding failure of Y-TZP zirconia (Y-TZP zirconia의 기계적 표면처리가 파절저항과 접착계면 실패에 미치는 영향)

  • Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.102-111
    • /
    • 2014
  • Purpose: Surface damage and bonding strength difference after micromechanical treatment of zirconia surface are to be studied yet. The aim of this study was to evaluate the difference of fracture resistance and bonding strength between more surface-damaged group from higher air-blasting particle size and pressure, and less damaged group. Materials and Methods: Disk shape zirconia ($LAVA^{TM}$) was sintered and air-blasted with $30{\mu}m$ particle size (Cojet), under 2.8 bar for 15 seconds, $110{\mu}m$ particle size (Rocatec), under 2.8 bar for 15 seconds, and $110{\mu}m$ particle size (Rocatec), under 3.8 bar for 30 seconds respectively. Biaxial flexure test and bonding failure load test were performed serially (n = 10 per group). For bonding test, specimens were bonded on the base material having similar modulus of elasticity of dentin with $200{\mu}m$-thick resin cement for tension of surface damage. Failure load of bonding was detected with acoustic emission (AE) sensor. Results: There were no significant differences both in the biaxial flexure test and bonding failure load test between groups (P > 0.05). Sub-surface cracks were all radial cracks except for two specimens. Conclusion: Within the limitations of no aging under monotonic load test, surface damage from higher air-blasting particle size and pressure was not significant. Evaluations of failure load with bonded zirconia disks was clinically relevant modality for surface damage and bonding strength, simultaneously.

EMT-Paramedic Student's Attitude to the Disabled (응급구조과 학생들의 장애인에 대한 태도)

  • Choi, Gil-Soon
    • The Korean Journal of Emergency Medical Services
    • /
    • v.15 no.2
    • /
    • pp.85-99
    • /
    • 2011
  • Purpose: The purpose of this study is to examine the EMT student's attitude to the disabled and provide the basic materials of educational program to make them have right awareness and attitude of the disabled. Methods: The subjects of this study were 348 of 339 emergency medical students at three departments of emergency medical in G metropolitan city who gave consent to take part in the research and the data were collected for 10 days from Mar. 2 to 11, 2011. It used DFS (Disability Factor Scale) developed by Siller (1967) and revised and complemented by Lee Jong Nam (1997) after validity and reliability test. Data collected were analyzed with technical statistics, t-test and ANOVA using SPSS/ PC 12.0 Results: The results of this study are summarized as follows. 1. On the question that there are the disabled around the subjects, 74.7% of the respondents answered 'none', and on the question of having concerns on the disabled problems, 61.5% of the respondents answered 'they have no concerns on them'. In addition, on the question of effective methods for improving a negative awareness of the disabled, many of subjects responded the governmental support must be a priority. 2. The subjects' attitude to the disabled scored average 3.13 and they have positive attitude to the disabled. In six sub-areas of attitude to the disabled, tension in contact with the disabled scored 2.90, inferred emotional disorder 2.79, unconditional repulsion 2.78, refusal to friendly relation 2.74, limitation of other functions undamaged 2.66 and distorted identification 2.65. 3. Variable showing a significant difference in the results of analysis according to general characteristics of subjects was age and those who are over '21' showed more positive attitude to the disabled than those who are below '20'. 4. In the results of analysis according to the subjects' disability related characteristics, those who have the disabled in their friends or family and have concerns on the disabled problems have a positive attitude to the disabled. Promotion and education through mass communication for changing the awareness of the disabled into a positive attitude will be most effective. Conclusion: Consequently, positive attitude of EMT student's to the disabled can be fostered by continuous contact with the disabled and their participation in voluntary services in the dimension of individual or school will be important and also the various practical methods such as enlightenment movement and supply of right information through mass communication should be sought.

EFFECT OF TAPER AND SURFACE AREA OF INNER CROWN ON THE RETENTIVE FORCE OF ELECTROFORMED OUTER CROWN (전기성형술로 제작된 외관의 유지력에 내관의 축면경사도와 표면적이 미치는 영향)

  • Kang Wan-Keun;Lim Jang-Seop;Jeon Young-Chan;Jeong Chang-Mo;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.165-173
    • /
    • 2006
  • Purpose: With gold electroforming system fir the double crown, the secondary crown is electroformed directly onto the primary crown. An even thick layer of high precision can be acquired. It is thought that the retention of electroformed outer crown is primarily acquired by the adhesive force (surface tension) through the saliva which is interposed between precisely fitted inner and outer crown. The purpose of this study was to investigate the effect of taper and surface area of inner crown on the retentive force of electroformed outer crown according to the presence of saliva. Materials and methods: 32 titanium inner crowns with cervical diameter of 8 mm and cone angles of 0, 2, 4, 6 degrees, which had same surface area by regulated height, were machined on a lathe. Another 32 titanium inner crowns with cone angles of 0, 2, 4, 6 degrees, which had doubled surface area by increased cervical diameter. were fabricated. Eight specimens of each group, for a total of 64 titanium inner crowns, were prepared. The electroformed outer crowns were fabricated directly on the inner crowns by using electroforming machine(GAMMAT free, Gramm Technik, Germany). The tertiary frameworks were waxed-up on the electroformed outer crown and cast using nonprecious alloy($Rexillium^(R)III,\;Jeneric^(R)/Pentronh^(R)$ Inc., USA). The cast metal frameworks were sandblasted with alubimium oxides and cemented using resin cement(Superbond C&B, Sun Medical Co., Japan) over the electroformed copings of each specimen. Then, artificial saliva($Taliva^(R)$, Halim Pharm. Co., Korea) was sprayed between the inner and outer crown, and they were connected under 5 kg force. The retentive force was measured by the universal testing machine(Tinius Olsen 1000, Tinius Olsen, USA) with a cross-head speed of 66.67 mm/sec. The direction of cross-head travel was exactly aligned with the path of removal of the respective specimens. This measurement procedures for retentive force of electroformed outer crown with artificial saliva were repeated in the same way without presence of artificial saliva. Results and Conclusion: The following conclusions were drawn: 1. The retentive force of electroformed outer crown was decreased according to increased taper of inner crown(P<.05). 2. The retentive force of electroformed outer crown showed no significant differences according to surface area and the presence of artificial saliva(P>.05).

Analysis on Ignition Delay Characteristics of Bio Aviation Fuels Manufactured by HEFA Process (HEFA 공정으로 제조된 바이오항공유의 점화지연특성 분석)

  • Kang, Saetbyeol
    • Korean Chemical Engineering Research
    • /
    • v.57 no.5
    • /
    • pp.620-627
    • /
    • 2019
  • In this study, ignition delay characteristics of various bio aviation fuels (Bio-ADD, Bio-6308, Bio-7720) produced by HEFA process using different raw materials were compared and analyzed. In order to confirm the feasibility of applying bio aviation fuel to actual system, ignition delay characteristics of petroleum-based aviation fuel (Jet A-1) and blended aviation fuel (50:50, v:v) also analyzed. Ignition delay time of each aviation fuel was measured by using CRU, surface tension measurement and GC/MS and GC/FID analysis were performed to interpret the results. As a result, ignition delay time of Jet A-1 was the longest at all temperature because it contains aromatic compounds about 22.8%. The aromatic compounds can produce benzyl radical which is thermally stable and has low reactivity with oxygen during decomposition process. In the case of bio aviation fuels, ignition delay times were measured similarly because the ratio of n-paraffin/iso-paraffin constituting each aviation fuel is similar (about 0.12) and the composition ratio of cycloparaffin also has no difference. In addition, ignition delay times of blended aviation fuels (50:50, v:v) were measured close to the mean value those of each fuel so it was confirmed that it can be applied without any changing or improving of existing system.