• Title/Summary/Keyword: no reference

Search Result 2,206, Processing Time 0.04 seconds

Comparative Evaluation of Erythrocyte Sedimentation Rate by the Test 1 Analyzer and Westergren method in Patients with Anemia (빈혈환자에서 자동 ESR 기기인 Test 1과 Westergren법의 비교)

  • Kim, Il Taek;Kim, Jong Seok;Park, Yeon Bo;Lim, Jae Sil
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.137-143
    • /
    • 2004
  • Erythrocyte sedimentation rate(ESR) measurements were performed in a total of 191 blood samples from patients below a hematocrit of 35% by both the Test-1(SIRE Analytical Systems, Udine, Italy) and the Westergren method, endorsed as the reference method for ESR by the International Council for Standardization in Hematology(ICSH). The corrected Westergren ESR values were also obtained applying the formula of Fabry (corrected ESR = ESR measured x 15/55-Hct). Linear regression analysis showed a close correlation (r=0.85) between the two methods both before and after ESR correction in total samples. There was no significant correlation difference between two methods in both two groups with hemoglobin $${\geq_-}9g/dl$$ and <9g/dl before and after ESR correction (r=0.873, r=0.827 respectively before correction and r=0.867, r=0.830 respectively after correction). Also, for two groups with hematocrit $${\geq_-}24%$$ and <24%, no significant difference was observed (r=0.859, r=0.792 respectively before correction and r=0.782, r=0.842 respectively after correction). However, for samples with <60mm of Westergren ESR before correction, a better correlation coefficient was obtained than samples with $${\geq_-}60mm$$(r=0.701, r=0.541 respectively). In corrected Westergren ESR, also samples that were obtained with <40mm showed better correlation than samples with $${\geq_-}40mm$$ (r=0.690, r=0.347 respectively). In conclusion, we found a good correlation between Test-1 and Westergren measurements in patients with anemia but an expert group discussion is required to solve discrepancy between two methods in blood samples with very high ESR.

  • PDF

Effects of Various Growing Conditions of the Mat-type Seedlings on the Cutting forces for ower Rice Transplanter. (Mat묘의 육모조건이 이앙기의 소요전단력에 미치는 영향)

  • 허민근;김성래
    • Journal of Biosystems Engineering
    • /
    • v.4 no.1
    • /
    • pp.48-57
    • /
    • 1979
  • In order to obtain a standard reference for designing an adequate power rice transplanter, the cutting forces depending upon variety of seedling, sowing density, seedling age and soil moisture content of mat-type seedling were measured by the rice transplanter installed with force measuring device of dynamic strain gage system in the laboratory. The result of this study are summarized as follows : 1. Cutting velocity and acceleration transplanting hoe obtained from jinematic analysis of planting mechanism was 1.32m/sec and 81.5m/$sec^2$ when planting crank-shaft rpm was 160. 2. Little difference between cutting forces on 30-days old seelings of japonica and Indica type was observed, as the cutting forces determined were 2.0kg per hill for Japonica type and 2.1kg per hill for Indica type. 3. Cutting forces determined on 40-days old seedlings were 2.5kg, 2.3kg, 3.1kg and 2.9kg per hill for Milyang No.15, Tongil, Akibare and Milyang No.23 compared to the other varieties. 4. The cutting force was not greatly affected by the sowing densities , only five percent of differences were observed epending upon the sowing densities. 5. Cutting forces were 2.7kg and 2.0kg per hill on 40-days old seedlings and 30-days old seedlings respectively. About 38 percent of more forces was required in cutting 40-days old seedling than in cutting 30-days old seedlings. 6. More cutting forces were required as soil moisture content of mat-type seedling was decreased. 7. Root length after cutting by the planting hoe and their relationships with soil moisture content on 30-days old seedlings, are as follows ; $y=4.147-11.384x+ 28.854x^2$ where , $y$=root length after cutting. (cm) , $x$=soil ture content of mat type seedlings.(%, d.b.) 8. Cutting forces were varied with the width of cuttings ; those on 40-days old mat type seedlings were 2.7kg and 2.2kg per hill when cutting with 14 mm and 10mm of width respectively, about 32 percent of more forces was required when cuting with 14mm of width compared to 10mm of width.

  • PDF

Bioeuqivalence Study of Nabumetone Tablets in Man

  • Lee, Young-Joo;Jang, Eun-Ju;Lee, Jeong-Uk;Han, Yong-Hae;Chung, Suk-Jae;Lee, Min-Hwa;Shim, Chang-Koo
    • Archives of Pharmacal Research
    • /
    • v.18 no.5
    • /
    • pp.340-345
    • /
    • 1995
  • A nebumetone tablet in development $(Navuton^R)$ was tested for its bioequivalence to the erference tablet $(Uniton^R)$. Seventeen healthy Korean male subjects participated in this study. Each subject received a 1-g dose of nabumetone (2tables each) in an unbalanced, randomized, two-way crossover investigation. Serum concentrations of 6-methoxy-2-na-phthylacetic acid (6-MNA), a major metabolite of nebumetone, were measured over 120 hr interval by a high-performance liquid chromatography. The maximum serum concentration $(C_{max})$ and time to reach the maximum concentration$(T_{max})$ were read directly, but area under the serum concentration time curve from time 0 to 120 hr (AUC) and mean residence time serum curves showed multiple peaks of 6-MNA in most subjects, and the $C_{max}$ and $T_{max}$ were read from the highest serum peaks. calculated bioavailability parameters for test and reference tablets were 148.6 : 1377.9 $\mug \cdot hr/ml$ for AUC; 25.2:23.1 $\mu/ml$ for $C_{max}$; 11.8:16.4 hr for $T_{max}$, and 42.6 : 43.8 hr for MRT, respectively. The paired t-test revealed no significant differences in all the parameters between the two tablets. Analysis ofl variance (ANOVA) revealed no significant differences between groups and formulations in all the parameters ($C_{max}$ and $T_{max}$, AUC and MRT) indicating the crossover design of the experiment was properly performed. But significant differences (p<0.05) between subject/groups and periods were found for all the parameters indicating substantial intersubject and interperiodic variations for these parameters.

  • PDF

Use of thermography in lameness caused by musculoskeletal disease in Thoroughbred mare (적외선 체열촬영술을 이용한 thoroughbred 말의 근골격계 파행진단 증례)

  • Park, Hyoung-Joon;Song, Yun-O;Lee, Jin-Ju;Ji, Chang-Moo;Jung, Hae-Won;Kim, Suk;Cho, Kyu-Won;Cho, Jae-Hyeon;Kim, Jong-Shu;Moon, Oun-Kyong;Song, Young-Min;Kim, Chung-Hui
    • Korean Journal of Veterinary Service
    • /
    • v.35 no.3
    • /
    • pp.245-250
    • /
    • 2012
  • The mare had lameness and asymmetry edematous on its tarsal and metatarsal joints at the initial physical examination. The pain was elicited with a palpation along the metatarsal articulations. No significant abnormalities were detected in the screening test. However, thermographic images revealed a significant increase in the surface temperature at the joint of the hindlimb when compared to the reference range. At necropsy, an irregularity of the surface and excessive synovial fluid were observed on the right tarsal joint. No bacterial growth was shown in the cultures of synovial fluid. Staphylococcus aureus was detected in the subcutaneous discharge. Taken together, the thermography images were very useful in localizing the area of injury and were an effective diagnostic methodology for assessing lameness.

Calculating Cp of Position Tolerance when MMC Applied at Datum and Position Tolerance (데이텀과 위치공차에 최대실체조건이 적용되었을 경우의 위치공차의 Cp)

  • Kim, Jun-Ho;Chang, Sung-Ho
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.3
    • /
    • pp.1-6
    • /
    • 2017
  • Process capability is well known in quality control literatures. Process capability refers to the uniformity of the process. Obviously, the variability in the process is a measure of the uniformity of output. It is customary to take the 6-sigma spread in the distribution of the product quality characteristic as a measure of process capability. However there is no reference of process capability when maximum material condition is applied to datum and position tolerance in GD&T (Geometric Dimensioning and Tolerancing). If there is no material condition in datum and position tolerance, process capability can be calculated as usual. If there is a material condition in a feature control frame, bonus tolerance is permissible. Bonus tolerance is an additional tolerance for a geometric control. Whenever a geometric tolerance is applied to a feature of size, and it contains an maximum material condition (or least material condition) modifier in the tolerance portion of the feature control frame, a bonus tolerance is permissible. When the maximum material condition modifier is used in the tolerance portion of the feature control frame, it means that the stated tolerance applies when the feature of size is at its maximum material condition. When actual mating size of the feature of size departs from maximum material condition (towards least material condition), an increase in the stated tolerance-equal to the amount of the departure-is permitted. This increase, or extra tolerance, is called the bonus tolerance. Another type of bonus tolerance is datum shift. Datum shift is similar to bonus tolerance. Like bonus tolerance, datum shift is an additional tolerance that is available under certain conditions. Therefore we try to propose how to calculate process capability index of position tolerance when maximum material condition is applied to datum and position tolerance.

A Study on the Actual Profile of Emergency Medical Personnel's Pre-admission Infection Control - Based on Jeollabuk-do provincial area - (병원 전 응급의료종사자의 감염관리 실태 연구 - 전북지역 중심으로 -)

  • Shin, Sang-Yol;Jeong, Tae-Oh
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.2
    • /
    • pp.19-27
    • /
    • 2007
  • Purpose: By identifying the actual profile of emergency medical personnel's pre-admission infection control practices, this study intended to provide a basic reference material for the improvement and reorientation of pre-admission infection control measures, and thereby help establish an effective plan for pre-admission infection control activities. Methods: Total 119 EMT's working for Jeollabuk-do Provincial Fire Defense HQ were asked to join a structured questionnaire survey from June to August 2006. Results: 1. It was found that 56.1% respondents answered no guideline available on the prevention of infection. Out of our rescue brigade members who knew about relevant guideline available, 34.2% respondents answered that their department conducted quality control program for the guideline. 2. For protective outfit in emergency practice, it was found that most respondents put on gloves or nothing at all(38%), which was followed by sterile gloves(29.2%), disposable mask(26.9%), gown(4.3%) and protective goggle(1.6%). And it was noted that all respondents(100%) washed out any clothing contaminated with somatic secretion on their own. 3. For a question about any experience in emergency activities exposed to infectious diseases, it was found that most of all respondents(77.9%) answered 'No', which was followed by 'Don't Know'(18.6%) and Yes(3.9 %). 4. For a question about any experience in inquiring of patients about infectious diseases, it was found that most respondents(49.4%) answered 'Yes' and 'Sometimes'(9.1%). It was noted that 20.2% respondents had extra medical examination in medical institution in terms of whether they were exposed to infectious diseases, apart from regular medical examination. Conclusions: In order to protect 119 EMT's from infectious diseases, it will be necessary to acquire emergency medical staffs specializing in infection control and organize corresponding personnel training units to keep providing reorientation and evaluation. In addition, it will be also necessary to supply them with a full set personal protection apparatuses and other equipments required for disinfection and sterilization.

  • PDF

Characteristics on Stream Water Quality in the Northeastern Part of Puk'ansan National Park(II) - With a Special Reference to the Physicochemical Characteristics- (북한산국립공원(北漢山國立公園) 북동사면(北東斜面) 일대(一帶) 계류수질(溪流水質) 특성(特性)(II) -이화학적(理化學的) 특성(特性)을 중심(中心)으로-)

  • Park, Jae Hyeon
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.2
    • /
    • pp.241-248
    • /
    • 2000
  • This research was conducted to investigate the physicochemical characteristics of stream water at the four points in the northeastern part of Puk'ansan National Park from July, 1998 to November, 1999. The average pH of stream water was 6.65 and dissolved oxygen was $10.7mg/{\ell}$, which indicated that the quality could be categorized in the first class for the quality of river water quality standard. In addition, the water was soft water and average percentage of dissolved oxygen was 96.7%, which was almost saturated. The number of visitors resulted in the increase of dissolved ion, witch affected on electrical conductivity of the water. The relationships between those factors was significant at the 1% level in linear regression. The electrical conductivity and the amount of anion($Cl^-$, $NO{_3}^-$, $SO{_4}^{2-}$)in downstream were higher than those in upstream.

  • PDF

Input AC Voltage Sensorless Control for a Three-Phase Z-Source PWM Rectifier (3상 Z-소스 PWM 정류기의 입력 AC 전압 센서리스 제어)

  • Han, Keun-Woo;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.355-364
    • /
    • 2013
  • Respect to the input AC voltage and output DC voltage, conventional three-phase PWM rectifier is classified as the voltage type rectifier with boost capability and the current type rectifier voltage with buck capability. Conventional PWM rectifier can not at the same time the boost and buck capability and its bridge is weak in the shoot- through state. These problems can be solved by Z-source PWM rectifier which has all characteristic of voltage and current type PWM rectifier. By shoot-through duty ratio control, the Z-source PWM rectifier can buck and boost at the same time, also, there is no need to consider the dead time. This paper proposes the input AC voltage sensorless control method of a three-phase Z-source PWM rectifier in order to accomplish the unity input power factor and output DC voltage control. The proposed method is estimated the input AC voltage by using input AC current and output DC voltage, hence, the sensor for the input AC voltage detection is no needed. comparison of the estimated and detected input AC voltage, estimated phase angle of the input voltage, the output DC voltage response for reference value, unity power factor, FFT(Fast Fourier Transform) of the estimated voltage and efficiency are verified by PSIM simulation.

Bi-axial and shear buckling of laminated composite rhombic hypar shells

  • Chaubey, Abhay K.;Raj, Shubham;Tiwari, Pratik;Kumar, Ajay;Chakrabarti, Anupam;Pathak, K.K.
    • Structural Engineering and Mechanics
    • /
    • v.74 no.2
    • /
    • pp.227-241
    • /
    • 2020
  • The bi-axial and shear buckling behavior of laminated hypar shells having rhombic planforms are studied for various boundary conditions using the present mathematical model. In the present mathematical model, the variation of transverse shear stresses is represented by a second-order function across the thickness and the cross curvature effect in hypar shells is also included via strain relations. The transverse shear stresses free condition at the shell top and bottom surfaces are also satisfied. In this mathematical model having a realistic second-order distribution of transverse shear strains across the thickness of the shell requires unknown parameters only at the reference plane. For generality in the present analysis, nine nodes curved isoparametric element is used. So far, there exists no solution for the bi-axial and shear buckling problem of laminated composite rhombic (skew) hypar shells. As no result is available for the present problem, the present model is compared with suitable published results (experimental, FEM, analytical and 3D elasticity) and then it is extended to analyze bi-axial and shear buckling of laminated composite rhombic hypar shells. A C0 finite element (FE) coding in FORTRAN is developed to generate many new results for different boundary conditions, skew angles, lamination schemes, etc. It is seen that the dimensionless buckling load of rhombic hypar increases with an increase in c/a ratio (curvature). Between symmetric and anti-symmetric laminations, the symmetric laminates have a relatively higher value of dimensionless buckling load. The dimensionless buckling load of the hypar shell increases with an increase in skew angle.

CLINICAL EFFECTIVENESS OF BONE SCAN FOR DIFFERENTIAL DIAGNOSIS OF JAW LESION (악골 병소의 감별 진단시 골스캔의 임상적 유용성)

  • Kim, Jeong-Mo;Kim, Chul-Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.1
    • /
    • pp.33-41
    • /
    • 2007
  • Bone scan using radioactive isotope can be more effective than conventional X-ray radiograph for finding jaw lesion because it takes an image of the physiologic change of bone. This study is designed to show how available bone scan is able to diagnose jaw lesion better than simple X-ray and CT, as well as to determine a basis of diagnosis for jaw lesion using bone scan. The 77 patients, visiting the Oral & Maxillofacial Surgery, Department of Dankook University Hospital from January 2002. to August 2005. who were diagnosed histopathologically with postoperative malignant tumor, osteomyelitis, and bone infiltrative benign disease. Preoperative X-ray, CT, bone scan were taken and were compared with histopathologic finding. Also to compare specificty of each lesion in bone scan, bone density was measured to compare. The results were as follows. 1. Among the 25 cases of oral malignant tumor of bony invasion, a positive diagnosis associated with histopathologic evaluation, 22 cases(88%) in bone scan, 14 cases(56%) in CT image, and 10 cases40%) in simple X-ray. 2. Among the 31 cases of osteomyelitis, a positive diagnosis associated with histopathologic evaluation, 30 cases(97%) in bone scan, 23 cases(74%) in CT image, and 19 cases(61%) in simple X-ray. 3. Among the 11cases of bone infiltrative benign disease, a positive diagnosis associated with histopathologic evaluation, 11 cases(100%) in bone scan, 10 cases(91%) in CT image, and 6 cases(55%) in simple X-ray. 4. Measurement of bone density in each group showed no statistical significant difference between malignant tumor and osteomyelitis as well as benign bone disease. But, a statistical significance was seen between osteomyelitis and benign bone disease. From this results, bone scan are more sensitive than simple X-ray and CT image in jaw lesion diagnosis, but specificity shows no significant difference. Therefore, it should be suggested that evaluation of bone scan must be carrying out in reference to final histopathologic diagnosis.