• Title/Summary/Keyword: no reference

Search Result 2,206, Processing Time 0.03 seconds

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

  • Ozay Onoral;Sevcan Kurtulmus-Yilmaz;Dilem Toksoy;Oguz Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.6
    • /
    • pp.290-301
    • /
    • 2023
  • PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

Relative localization errors: The effect of reference location on the errors (상대적인 위치지각의 왜곡: 참조자극의 위치가 왜곡에 미치는 영향)

  • Li, Hyung-Chul
    • Korean Journal of Cognitive Science
    • /
    • v.15 no.3
    • /
    • pp.15-24
    • /
    • 2004
  • The perceived position of a flashing target object is generally biased towards the direction of eye movement when there is no reference around the target. Current research examined the localization accuracy of a flashing target relative to a static reference. The perceived location of the target relative to the reference was distorted and the pattern of perceptual distortion systematically depended on the position of the reference relative to the target. This kind of result was consistently observed regardless of the distance between the reference and the target and direction of pursuit eye movement. We have discussed how these results could he explained by the theories previously suggested to explain the localization of objects.

  • PDF

Reference Points Selection for Interpolation in Digital Elevation Model (수치표고모델의 보간기준점 선정에 관한 연구)

  • 최병길;김욱남;진세일
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.2
    • /
    • pp.131-136
    • /
    • 2003
  • The method that selects reference points for interpolation is very important in Digital Elevation Model. However, there is no definition of an accurate standard until now, so users select the reference points for interpolation at their option. This paper aims to study on the accurate selection of the reference points for interpolation of DEM. This paper analyzed the method using the number of points and the reference points selection method by using the average distance calculated, from irregular points. Based on the analysis of the results, it shows that the Kriging method applying of the average distance is more efficient in construction of DEM.

A Study on Design of Reference Model Following Fuzzy Controller Using Genetic Algorithm (유전알고리즘을 이용한 모델추종형 퍼지제어기 설계에 관한 연구)

  • Song, M.G.;Lim, S.W.;Hwang, G.H.;Park, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.130-132
    • /
    • 1997
  • This paper proposes a reference model following control system using fuzzy logic controller and genetic algorithm. A fuzzy logic controller is designed such that plant output follows the output generated by a reference model. In this paper, First-order and second-order reference model with no overshoot and fast rise time is designed. Experiment results show the effectiveness of the proposed controller in tracking property and robustness.

  • PDF

Unobtrusive Performance Evaluation of Reference Librarians in Academic Libraries of Korea (비 통보식 조사를 통한 참고사서 업무능력 평가)

  • Kim Youngshin
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.29
    • /
    • pp.305-343
    • /
    • 1995
  • The purposes of this study are to confirm the applicability of the unobtrusive evaluation to Korean libraries, to develop survey forms, check lists and evaluation criteria appropriate for Korean libraries, to analyze the relationship between the test variables and the performance level, to find out the causes of poor service if any, and to propose measures for improving the quality of reference services. The main results of the analyses are as follows : $\cdot$ The accuracy of answers was correlated to appropriateness of search process, way of providing answer, usage of language, approachability and use of second materials in the order named. That is, there was a strong correlation between accuracy and the variables related to librarian's behavior. $\cdot$ There was no statistically significant relationship between accuracy and the environmental aspects of reference department such as number of professional librarians, self-evaluation of reference collection, etc. $\cdot$ The main reasons for failing to give accurate answers were found to be weaknesses in understanding questions. developing search strategy logically and relating the querries to available information sources.

  • PDF

Interactive Judgemental Adjustment of Initial Forecasts with forecasting Support Systems (예측지원시스템에 의한 직관적 예측의 행태에 관한 연구)

  • Lim, Joa-Sang;Park, Hung-Kook
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.24 no.1
    • /
    • pp.79-98
    • /
    • 1999
  • There have been a number of empirical studios on the effectiveness of Judgmental adjustment to statistical forecasts Generally the results have been mixed. This study examined the impact of the reliability and the source of the additionally presented reference forecast upon the revision process in a longitudinal time series forecasting task with forecast support systems. A 2-between(reliability & source). 2-within(seasonality & block) factorial experiment was conducted with post-graduate students using real time series. Judgmental adjustment was found to improve the accuracy of initial eyeballing irrespective of the reliability of an additionally presented forecast. But it did not outperform the dampened reference forecast. No effect was found of the way the source of the reference forecast was framed. Overall the subjects anchored heavily on their Initial forecast and relied too little on the reference forecast irrespective of its reliability. Moreover they did not improve at the task over time, despite immediate outcome feedback.

  • PDF

Bayesian Hypothesis Testing for the Ratio of Means in Exponential Distributions

  • Kang, Sang-Gil;Kim, Dal-Ho;Lee, Woo-Dong
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.205-213
    • /
    • 2006
  • This paper considers testing for the ratio of two exponential means. We propose a solution based on a Bayesian decision rule to this problem in which no subjective input is considered. The criterion for testing is the Bayesian reference criterion (Bernardo, 1999). We derive the Bayesian reference criterion for testing the ratio of two exponential means. Simulation study and a real data example are provided.

  • PDF

A Design on Reference Model Following Fuzzy Control System Using Hysteresis element (비선형 요소를 이용한 기준 모델 추종형 퍼지 제어 시스템의 설계)

  • Hwang, C.S.;Nam, K.W.;Jeong, H.S.;Kim, D.W.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.974-976
    • /
    • 1996
  • In this paper, a reference model following control system using a fuzzy logic controller(FLC) is proposed By using an integrator and a nonlinear hysteresis element, a reference model whose response has no overshoot and fast rise time is designed. A FLC is designed to follow as close as possible to the response of the reference model. The proposed design method is shown that the robustness and the optimal tracking property can be achieved under modeling error, disturbance and parameter perturbations. The effectiveness of the proposed design method is verified through the simulation that compare using the FLC with using a $H_{\infty}$ controller.

  • PDF

NO Reduction and High Efficiency Combustion by Externally Oscillated Staging Burner

  • Lim, Mun-Sup;Yang, Won;Chun, Young-Nam
    • Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.158-163
    • /
    • 2009
  • It is difficult for a burner to achieve an increase in combustibility and a reduction of NOx emission, simultaneously. The reason is because thermal NOx could be reduced at low temperature, while the combustibility should be decreased. To solve this problem, an externally oscillated staging burner was developed, and experiment was conducted according to effective parameters. The combustibility could be improved through the accelerated transfer of heat, mass and momentum obtained by external oscillation. Also, NO is reduced by the decrease of residence time of burning gas in the local highest-temperature spot, which is decreased by the external oscillation and fuel staging. Experiments on variables were conducted to determine the reference flame, and the flame generating the lowest NO concentration was selected. The conditions of reference flame were oscillation frequency 250 Hz, sound pressure 1 VPP, and air ratio 1.1, and NO and CO concentrations were 1ppm and 20 ppm, respectively.