Outer Voltage Regulation Loop for Maximum Torque Operation of Interior Permanent Magnet Synchronous Motor in the Flux (약계자 영역에서 외부 전압제어 루프에 의한 매입형 영구자석 동기전동기의 최대 토오크 운전)

  • Kim, Jang-Mok;Sul, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.121-123
    • /
    • 1997
  • A novel flux-weakening scheme for the Interior Permanent Magnet Synchronous Motor (IPMSM) is proposed. This is implemented based on the output of the synchronous PI current regulator-reference voltage to the PWM inverter. Attractive features of this flux weakening scheme include no dependency on the machine parameters, the guarantee of current regulation at any operating condition, and smooth and fast transition into and out of the flux weakening mode without a discontinuity. Experimental results are presented to verify the feasibility of the proposed control scheme.

  • PDF

Real Time Tilt Servo Control of The Holographic Data Storage System (홀로그래픽 정보 저장 장치에서의 실시간 틸트 서보 제어)

  • Moon, Jae-Hee;Kim, Sang-Hoon;Yang, Jun-Ho;Yang, Hyun-Seok;Park, No-Cheol
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.1
    • /
    • pp.13-16
    • /
    • 2007
  • The purpose of this paper is real time tilt servo control of the holographic data storage system. Holographic data storage device is a next generation data storage device with high storage density, high transfer rate and short access time. This device is very sensitive to a disturbance due to the enormous storage density. As to the recording material changed disc type, the media continuously vibrates as the disc rotates. When disc rotates, deviation, eccentricity and unbalance disturbance are occurred. This disturbances cause disc tilt, finally reference beam does not illuminates to correct incidence angle. Therefore real time tilt servo control is essential. In this paper, the algorithm is proposed to make real time tilt detection in angle multiplexing of the holographic data storage system with an additional servo beam and the experiments are performed.

  • PDF

Numerical Analysis on Pressure Characteristics of the Pipe system of Train

  • Nam Seong-Won;Zhang Bo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.503-509
    • /
    • 2004
  • With modem computational fluid dynamics method (CFD), air-charging models of the air brake pipe system and auxiliary reservoir are built. Compared with one-dimension model, no empirical formula is introduced to solve branch pipe fields for two-dimension model. A modified operator-splitting method is presented to solve the coupled equations of pressure and velocity, and numerical simulation shows that it is very stable. Compare the numerical results with empirical data of heavy haul trains in home and abroad so as to prove the correctness of the theory and algorithm presented. This paper gives theoretic reference to the experiments of braking effects of heavy haul trains, and forms a basis for development of complete freight train air brake system simulation.

  • PDF

Classification of Degradation Types Based on Distribution of Blocky Blocks for IP-Based Video Services

  • Min, Kyung-Yeon;Lee, Seon-Oh;Sim, Dong-Gyu;Lee, Hyun-Woo;Ryu, Won;Lee, Kyoung-Hee
    • ETRI Journal
    • /
    • v.33 no.3
    • /
    • pp.454-457
    • /
    • 2011
  • In this letter, we propose a new quality measurement method to identify the causes of video quality degradation for IP-based video services. This degradation mainly results from network performance issues and video compression. The proposed algorithm identifies the causes based on statistical feature values from blocky block distribution in degraded IP-based videos. We found that the sensitivity and specificity of the proposed algorithm are 93.63% and 91.99%, respectively, in comparison with real error types and subjective test data.

Development of Dental Scanning System and Reproduction of Adjustable Upper Dental Impression Tray (치과용 스캐닝 시스템의 개발과 가변형 상악용 트레이의 재현성)

  • Cha, Young-Youp;Eom, Sang-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.3
    • /
    • pp.300-304
    • /
    • 2010
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable upper dental impression tray. The metal stock, individual, and new adjustable stock trays were used for 30 stone casts(10 casts each) duplicated a resin master model of maxilla. The dental stone was poured in a vinyl polysiloxane impressions and allowed to set for on hour. The master model and the duplicated casts were digitized using an dental scanning system. The distance between the reference points were measured and analyzed on the graphic image of 3D graphic software of CATIA. The statistical significance of the differences between the groups was determined by a two-way ANOVA. There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch. The adjustable upper stock tray showed clinically acceptable accuracies of the study cast produced by them.

A Study of the numerical method on the molecular transition flow for the rotating blades (회전날개주위 분자천이유동의 수치해석방법에 관한 연구)

  • 허중식;황영규;박종윤
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.2
    • /
    • pp.83-92
    • /
    • 1999
  • Pumping performance of a disk-type molecular drag pump for a hybrid molecular pump is numerically analyzed by the direct simulation onte-Carlo method. The flows in pumping channels are three-dimensional (3D) in a molecular transition regime. The main difficulty in modeling a 3D case comes from the rotating frame of reference. Thus, trajectories of particles ar no longer straight lines. In the present study, trajectories of particles are calculated by integrating a system of differential equations including the Coriolis and centrifugal forces. The null-collisions. The present numerical results molecular model is used for calculation of molecular collisions. The present numerical results significantly disagree with the previously known ones. This indicates that an actual pumping passage is very limited to a narrow region due to the significant backstreaming of molecules from the outlet.

  • PDF

A Study on the Biological Organic, Nitrogen and Phosphorus Removal in Sequencing Batch Biofilm Reactor (연속회분식 생물막 반응기(Sequencing Batch Biofilm Reactor)를 이용한 수중의 유기물, 질소 및 인의 동시 제거에 관한 연구)

  • 박민정;김동석
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.2
    • /
    • pp.84-91
    • /
    • 2004
  • Biological nutrient removal(BNR) from wastewater was performed by adopting various process configurations. The simultaneous biological organics, phosphorus and nitrogen removal of synthetic wastewater was investigated in a sequencing batch biofilm reactor (SBBR). The other reactor was operating as a reference, without biofilm being added. The cycling time in SBR and SBBR was adjusted at 12 hours and then certainly included anaerobic and aerobic conditions. Both systems has been operated with a stable total organic carbon(TOC), nitrogen and phosphorus removal performance for over 90 days. Average removal efficiencies of TOC and total nitrogen were 83% and 95%, respectively. The nitrification rate in SBR was higher than that in SBBR. On the contrary, the denitrification rate in SBBR was higher than that in SBR. The phosphorus release was occurred in SBBR, however, not in SBR because of the inhibition effect of NO$_3$$^{[-10]}$ .

A MIMO Adaptive Beanforming Algorithm for Smart Antennas (스마트안테나용 MIMO 적응빔형성 알고리즘)

  • Park, Jaedon;Tuan, Le-Minh;Giwan Yoon;Kim, Jewoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.323-326
    • /
    • 2001
  • We propose a new MUD adaptive beamforming algorithm. It requires no reference signal and consists of two Processing stages. The first stage performs a scan function, and the second stage performs an adaptive beamforming algorithm. Computer simulations, considering multi-path Rayleigh Fading Channel in CUMA, are presented to verify the performance.

  • PDF

A Novel Switching Mode for High Power Factor Correction and Low THD

  • Park, Gyumin;Eum, Hyunchul;Yang, Seunguk;Hwang, Minha;Park, Inki
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.210-212
    • /
    • 2018
  • A new switching mode has been proposed to obtain high power factor and low THD in single stage AC-DC converter. The conventional voltage mode control in critical conduction mode distorts input current shape with poor THD in flyback topology. Once TRIAC dimmer is connected, visible flicker in the LED lamp is easily detected due to a lack of TRAIC holding current near the input voltage zero cross. The newly proposed method can shape the input current by providing a desired reference voltage so that low THD is obtained by ideal sinusoidal input current in case of no dimmer connection and flat input current performs good TRIAC dimmer compatibility in phase-cut dimming condition. To confirm the validity of the proposed method, theoretical analysis and experimental result from 8W dimmable LED lighting system are presented.

  • PDF

Synthesis and Pharmacological Studies for New Benzotriazole and Dibenzodiazepine Derivatives as Antipsychotic Agents

  • El-Sabbagh, Osama I.;El-Nabtity, Sameh M.
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.7
    • /
    • pp.1445-1451
    • /
    • 2009
  • New benzotriazoles (5-8) or dibenzodiazepine derivatives (11-18) were synthesized starting from 3-[(2-amino- 4,5-disubstitutedphenyl)amino]-5,5-disubstitutedcyclohex-2-enones (1-4) through internal coupling of their diazonium salts or internal Mannich reaction in the presence of aromatic aldehydes. Pharmacological evaluation of benzotriazole and dibenzodiazepine derivatives for their clozapine-like properties revealed that dibenzodiazepine 11 bearing 4-bromophenyl group exhibited the same antipsychotic activity as the reference drug clozapine while the activity of benzotriazole 7 was 25% lesser than that of clozapine. Moreover, compounds 7 and 11 did not show significant CNS depressant activity as well as no or slight neurotoxicity on contrast to clozapine when tested in mice using forced swim, rotarod and horizontal screen tests.