• Title/Summary/Keyword: no reference

Search Result 2,206, Processing Time 0.032 seconds

SPECTRUM WEIGHTED RESPONSES OF SEVERAL DETECTORS IN MIXED FIELDS OF FAST AND THERMAL NEUTRONS

  • Kim, Sang In;Chang, Insu;Kim, Bong Hwan;Kim, Jang Lyul;Lee, Jung Il
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • The spectrum weighted responses of various detectors were calculated to provide guidance on the proper selection and use of survey instruments on the basis of their energy response characteristics on the neutron fields. To yield the spectrum weighted response, the detector response functions of 17 neutron-measuring devices were numerically folded with each of the produced calibration neutron spectra through the in-house developed software 'K-SWR'. The detectors' response functions were taken from the IAEA Technical Reports Series No. 403 (TRS-403). The reference neutron fields of 21 kinds with 2 spectra groups with different proportions of thermal and fast neutrons have been produced using neutrons from the $^{241}Am$-Be sources held in a graphite pile, a bare $^{241}Am$-Be source, and a DT neutron generator. Fluence-average energy ($E_{ave}$) varied from 3.8 MeV to 16.9 MeV, and the ambient-dose-equivalent rate [$H^*(10)/h$] varied from 0.99 to 16.5 mSv/h.

Current Conservation Factors for Consistent One-Dimensional Neutronics Modeling

  • Lee, Kibog;Joo, Han-Gyu;Cho, Byung-Oh;Zee, Sung-Quun
    • Nuclear Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.235-243
    • /
    • 2000
  • A one-dimensional neutronics formulation is established within the framework of the nonlinear analytic nodal method such that it can result in consistent one-dimensional models that produce the same axial information as their corresponding reference three-dimension81 models. Consistency is achieved by conserving axial interface currents as well as the planar reaction rates of the three-dimensional case. For current conservation, flux discontinuity is introduced in the solution of the two-node problem. The degree of discontinuity, named the current conservation factor, is determined such that the surface averaged axial current of the reference three-dimensional case can be retrieved from the two-node calculation involving the radially collapsed group constants and the discontinuity factor. The current conservation factors are derived from the analytic nodal method and various core configurations are analyzed to show that the errors in K-eff and power distributions can be reduced by a order of magnitude by the use of the current conservation factor with no significant computational overhead.

  • PDF

Acute pancreatitis in hand, foot and mouth disease caused by Coxsackievirus A16: case report

  • Park, Byungsung;Kwon, Hyuckjin;Lee, Kwanseop;Kang, Minjae
    • Clinical and Experimental Pediatrics
    • /
    • v.60 no.10
    • /
    • pp.333-336
    • /
    • 2017
  • Coxsackievirus A16 (CA16), which primarily causes hand, foot, and mouth disease (HFMD), is associated with complications, such as encephalitis, acute flaccid paralysis, myocarditis, pericarditis, and shock. However, no case of pancreatitis associated with CA16 has been reported in children. We report a case of CA16-associated acute pancreatitis in a 3-year-old girl with HFMD. She was admitted because of poor oral intake and high fever for 1 day. Maculopapular rashes on both hands and feet and multiple vesicles on the soft palate were observed on physical examination. She was treated conservatively with intravenous fluids. On the fourth hospital day, she had severe abdominal pain and vomiting. The serum levels of amylase and lipase were remarkably elevated (amylase, 1,902 IU/L; reference range, 28-100 IU/L; lipase, >1,500 IU/L; reference range, 13-60 IU/L), and ultrasonography showed diffuse swelling of the pancreas with a small amount of ascites. The real-time reverse transcription polymerase chain reaction result from a stool sample was positive for CA16. CA16 can cause acute pancreatitis, and should be considered in the differential diagnosis of abdominal pain in children with HFMD.

Digital Image Quality Assessment Based on Standard Normal Deviation

  • Park, Hyung-Ju;Har, Dong-Hwan
    • International Journal of Contents
    • /
    • v.11 no.2
    • /
    • pp.20-30
    • /
    • 2015
  • We propose a new method that specifies objective image quality factors by evaluating an image quality measurement model using random images. In other words, No-Reference variables are used to evaluate the quality of an original image without using any reference for comparison. 1000 portrait images were collected from a web gallery with votes constituting over 30 recommendation values. The bottom-up data collecting process was used to calculate the following image quality factors: total range, average, standard deviation, normalized distribution, z-score, preference percentage. A final grade is awarded out of 100 points, and this method ranks and grades the final estimated image quality preference in terms of total image quality factors. The results of the proposed image quality evaluation model consist of the specific dynamic range, skin tone R, G, B, L, A, B, and RSC contrast. We can present the total for the expected preference points as the average of the objective image qualities. Our proposed image quality evaluation model can measure the preferences for an actual image using a statistical analysis. The results indicate that this is a practical image quality measurement model that can extract a subject's preferred image quality.

Experimental evaluation of splicing of longitudinal bars with forging welding in flexural reinforced concrete beams

  • Sharbatdar, Mohammad K.;Jafari, Omid Mohammadi;Karimi, Mohammad S.
    • Advances in concrete construction
    • /
    • v.6 no.5
    • /
    • pp.509-525
    • /
    • 2018
  • In this paper the application of forging process as benefit technique in Reinforced Concrete (RC) beam bars and comparison to lap splices was experimentally investigated with four concrete beam specimens with same dimensions and reinforcement details. The reference specimen was with no splices and the other three beams were with different splices (100% forging in the middle, 50% forging, and 100% lap splices in the middle). Beams were tested with the four points load system. Experimental test results indicated that using forging process as new bar splicing method can have high effects on increasing ductility and energy dissipation of concrete structures. It also proved that this method increased the flexural rigidity, energy absorption, and ductility of the RC beams. And also this research results showed that the flexural capacity and ductility of the beam with 50% forging were respectively increased up to 10% and 75% comparing to that of reference specimen, but the energy absorption of this beams was decreased up to 27%. The ductility of beam with 50% forging was increased up to 25% comparing the ductility of beam with 100% forging.

VALIDITY OF POSTERIOR ANTERIOR CEPHALOMETRIC AND 3D-CT FOR ORBITAL CANTING ANALYSIS (안와 경사의 분석을 위한 정모 두부규격방사선사진, 3D-CT의 유용성 평가)

  • Kim, Jin-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.6
    • /
    • pp.546-553
    • /
    • 2008
  • Purpose: The purpose of this study was to estimate validity of posterior anterior cephalometric and 3D-CT for orbital canting analysis. Materials and methods: Three trained observers classified two patients group using standardized frontal photographs of facial asymmetry patients. Group A consisted of patients with facial asymmetry and orbital canting(n=19), and group B consisted of patients with only facial asymmetry(n=43). Orbital canting was measured with line of bilateral inferior orbitale. Orbital canting measurement was done with posterior anterior cephalometric and 3D-CT. Each horizontal reference line was established by bilateral GWSO(cephalometric), FZS(3D-CT). Maxillary canting and mandibular deviation angle were also measured and analyzed with orbital canting. Results: The mean orbital canting was $3.03{\pm}1.00^{\circ}$ in Group A and $1.11{\pm}0.76^{\circ}$ in Group B in frontal photograph. The mean orbital canting was $1.20{\pm}0.74^{\circ}$ in group A and $1.22{\pm}0.65^{\circ}$ in group B by cephalometric analysis(p>0.05). In 3D-CT, orbital canting was almost paralleled with horizontal reference line. The orbital canting, maxillay canting and mandibular deviation between two groups showed no significant differences except madibular deviation in 3D-CT. Conclusion: Common analysis of posterior anterior cephalometric and 3D-CT is not valide method to evaluate orbital canting for facial asymmetry patients with orbital canting.

Prediction of Effect Zone for Marine Organisms Using Distance Attenuation Equations for Oceanic Noise (수중소음 거리감쇠 특성식을 이용한 해양생물 피해영향범위 예측)

  • Ha, Jeong-Min;Lee, Jong-Myeong;Lee, Jeong-Hoon;Gu, Dong-Sik;Choi, Byeong-Keun
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.14-19
    • /
    • 2012
  • There are insufficient data to consider the effect zone for the marine life of coastal fisheries, because no standard has been defined for the sound level of marine life. In this study, equations for distance attenuation were used to determine the effect zone for oceanic noises. A reference noise level was divided into 4 parts to consider the characteristics of the fishes, and the effect zone of each reference noise level was determined. To increase the reliability of the effect scope, approximately 100 repetitions of blasting work split into several parts by the boring depth, the sound level of the source caused by an increase in weight, and the effect zone were calculated using the prediction equation. According to the prediction, the maximum distance of the effect zone was 4.92 km.

Skin Penetration and in Vivo Local Anesthetic Effect of Microemulsion-based Hydrogels Containing Lidocaine (리도카인을 함유하는 마이크로에멀젼 겔의 피부침투성 및 in vivo 마취효과)

  • Shin, Hyun-Woo;Lee, Gi-Bong;Lee, Sang-Kil;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.4
    • /
    • pp.273-278
    • /
    • 2000
  • Several topical preparations containing lidocaine, a widely used local anesthetic agent, have been developed and marketed recently for the treatment of premature ejaculation. In this study, microemulsion(ME)-based hydrogels containing lidocaine were prepared by dispersing ME to hydrogel bases such as Carbopol, sod. alginate, and sod. carboxymethylcellulose. Lidocaine-containing ME was thermodynamically stable over 6 months and had a diameter ranging from 10 to 100 nm. In vitro skin penetration of lidocaine from ME-based hydrogels followed apparent zero-order kinetics. ME-based hydrogel showed higher drug penetration during fifteen minutes after application than alcoholic hydrogel, reference preparation. Tail flick test in rat was introduced to compare in vivo local anesthetic effects of different hydrogels, and the results showed that ME-based hydrogels are superior to other hydrogels. In optical microscopy, recrystallization of lidocaine was observed within 5 min after application of reference hydrogel, but there was no change in ME-based hydrogels even after 30 minnute. These results indicated that ME-based hydrogels had some advantages in skin penetration, anesthetic effect and physical stability compared with alcoholic hydrogels. Finally it is possible to conclude that ME-based hydrogels containing lidocaine is a good topical drug delivery system for the treatment of premature ejaculation.

  • PDF

Qualitative and Quantitative Analysis of Genetically Modified Pepper

  • Song, Hee-Sung;Kim, Jae-Hwan;Kim, Dong-Hern;Kim, Hae-Yeong
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.2
    • /
    • pp.335-341
    • /
    • 2007
  • For the development of qualitative and quantitative PCR methods of genetically modified (GM) pepper developed in Korea, a capsanthin-capsorubin synthase (CCS) gene was used as the endogenous reference gene. The primer pair ccs-F/R amplifying the pepper endogenous gene gave rise to an amplicon of 102 bp. No amplified product was observed when DNA samples from 16 different plants were used as templates. The construct-specific primer pairs amplifying the junction region of the bar gene and Ti7 introduced in GM pepper gave rise to an amplicon of 182 bp. Quantitative PCR assay was performed using a TaqMan probe and a standard plasmid as a reference molecule, which contained both an endogenous and event-specific sequence. For the validation of this method, the test samples containing 0.1, 1, 3, 5, and 10% GM pepper were quantified.

A Modularized Charge Equalizer Using the Magnetizing Energy of the Multi-Winding Transformer (다권선 변압기의 자화 에너지를 이용한 모듈화 전하 균일 장치)

  • Lim, Chang-Soon;Hyun, Dong-Seok;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.393-400
    • /
    • 2012
  • The modularized equalizers normally use additional components among the modules in the long series-connected lithium-ion battery string. In these approaches, the overall systems are heavy, bulky, and high-priced. Furthermore, the losses related to additional components decrease the system efficiency. To avoid these problems, a modularized equalizer, which has no additional components among the modules, is required. This paper proposes a novel control scheme using the magnetizing energy of the multi-winding transformer for the module equalization. In this scheme, the high duty cycle is applied to the module where the voltage is higher than the reference voltage and the low duty cycle is applied to the module where the voltage is lower than the reference voltage. Due to the different duty cycle, more electric charges are transferred from high voltage module to the low voltage module during the turn-off switching interval. Using the proposed control scheme, the equalizer system does not suffer from the size, cost, and loss related to the modularization. The experimental results are provided to verify the effectiveness of the proposed modularized equalizer.