• Title/Summary/Keyword: no reference

Search Result 2,206, Processing Time 0.034 seconds

Dietary Intakes, Serum Concentrations, and Urinary Excretions of Fe, Zn, Cu, Mn, Se, Mo, and Cr of Korean Young Adult Women (일부 젊은 성인여자의 Fe, Zn, Cu, Mn, Se, Mo 및 Cr의 식사섭취, 혈청농도 및 소변배설)

  • Kim, Kyune-Hee;Lim, Hyeon-Sook
    • Journal of Nutrition and Health
    • /
    • v.39 no.8
    • /
    • pp.762-772
    • /
    • 2006
  • This study was conducted to investigate dietary intakes, serum concentrations, and urinary excretions of iron (Fe), zinc (Zn), copper (Cu), manganese (Mn), selenium (Se), molybdenum (Mo), and chromium (Cr) of Korean young adult women. A total of 19 apparently healthy young adult women aged in their twenties or thirties participated voluntarily. One-tenth of all foods they consumed for 3 consecutive days were collected, all urine excreted for the same 3 days was gathered, and fasting venous blood was withdrawn for the trace mineral analyses. Of the food, blood, and urine samples, the contents of Zn, Cu, Mn, Se, Mo, and Cr were analyzed by inductively coupled plasma-mass spectroscopy (ICP-MS) and that of Fe by inductively coupled plasma-atomic emission spectroscopy (ICP-AES) after wet digestion. The intake of Fe, $6.94{\pm}2.18mg$, did not meet the estimated average requirement (EAR) for Korean women aged 20-29 years old. On the contrary, the intakes of Zn ($9.35{\pm}4.95mg$), Cu ($1.18{\pm}0.26mg$), and Mn ($3.69{\pm}0.69mg$) were sufficient for each respective EAR. However, some of the subjects did not take the EAR for Zn. The Se intake, $41.93{\pm}9.28{\mu}g$, however, was almost similar to the EAR for Se. Although there are no references for Mo and Cr, the intakes of these minerals ($134.0{\pm}49.1\;and\;136.5{\pm}147.9{\mu}g$, respectively) seemed to be excessively sufficient. Serum Fe concentration, $88.7{\pm}36.8{\mu}g/dL$, seemed to be a little bit lower than its reference median but within its normal range. Approximately one-fourth of the subjects were in anemic determined by Hb and Hct and below the deficiency serum level of Fe, $60{\mu}g/dL$. In addition, serum Se concentration, $3.73{\pm}0.60{\mu}g/dL$, was also below its reference median and normal range. However, serum concentrations of Zn ($99.6{\pm}30.6{\mu}g/dL$) and Mo ($0.25{\pm}0.10{\mu}g/dL$) were fairly good compared to each reference median. The status of Cu could be determined as good although its serum concentration ($91.6{\pm}14.6{\mu}g/dL$) was slightly below its reference median. Since there are no decisive reference values, it was not easy to evaluate serum concentrations of Mn ($0.93{\pm}0.85{\mu}g/dL$) and Cr ($8.60{\pm}7.25{\mu}g/dL$). But Mn and Cr status seemed to be adequate. Urinary Fe excretion, $4.48{\pm}1.98{\mu}g/dL$, was pretty much lower than its reference and that of Se, $2.45{\pm}1.17{\mu}g/dL$, was also lower than its average. On the other hand, those of Zn ($42.95{\pm}20.47{\mu}g/dL$) and Cu ($5.68{\pm}1.50{\mu}g/dL$) were flirty good. In case of Mn, urinary excretion, $0.31{\pm}0.09{\mu}g/dL$, was much greater than its reference. Urinary excretions of Mo ($7.48{\pm}2.95{\mu}g/dL$) and Cr ($1.37{\pm}0.41{\mu}g/dL$) were very higher compared to each reference. The results of this study revealed that Korean young adult women were considerably poor in Fe status, a bit inadequate in Se status, partly inadequate in Zn status, and flirty good in Cu, Mn, Mo and Cr status. However, there was a problem of excessive intakes of Mo and Cr. It, therefore, should be concerned to increase the intakes of Fe, Se and Zn but to decrease Mo and Cr consumption for young adult women.

No Spike PFD(Phase Frequency Detector) Using PLL( Phase Locked Loop ) (PLL(phase locked loop)을 이용한 No Spike 위상/주파수 검출기의 설계)

  • 최윤영;김영민
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1129-1132
    • /
    • 2003
  • 본 논문에서는 위상/주파수 검출기을 설계시 문제가 되는 Reference Spur을 없게 하여 Low Noise를 구현할 수 있는 No Spike PFD(Phase Frequency Detector)를 제안한다. 위상동기루프의 특별한 형태로 차지 펌프 위상동기루프가 있다. 차지 펌프위상동기 루프는 일반적으로 3-state 위상/주파수 검출기를 이용한다. 이 3-state 위상/주파수 검출기는 기준 신호와 VCO 출력 신호의 위상차에 비례하는 디지털 파형으로 출력을 내보낸다. 차지 펌프 위상동기루프 그림 1 처럼 디지털 위상/주파수 검출기(PFD), 차지 펌프(CP), 루프 필터(LF), VCO로 구성된다. PFD 는 기준 신호와 VCO 에 의해 만들어진 출력 신호를 입력받아 각각의 위상과 주파수를 비교한다. 즉, 출력 신호가 기준 신호보다 느릴 때에는 출력 신호를 앞으로 당기기 위해서 up 신호를 넘겨주고, 출력 신호가 기준 신호보다 빠를 때에는 출력 신호를 뒤로 밀기 위해 down 신호를 넘겨준다. 차지 펌프(CP)의 전류를 Ip 라고 한다면, CP 에서 LF 로 흐르거나, LF에서 CP로 흐르는 전류 Ip의 평균량이 기준 신호와 VCO 출력 신호의 위상차에 비례하는 것이다.

  • PDF

Formulation of a reference coordinate system of three-dimensional head & neck images: Part II. Reproducibility of the horizontal reference plane and midsagittal plane (3차원 두부영상의 기준좌표계 설정을 위한 연구: II부 수평기준면과 정중시상면의 재현성)

  • Park, Jae-Woo;Kim, Nam-Kug;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.475-484
    • /
    • 2005
  • This study was performed to investigate the reproducibility of the horizontal and midsagittal planes, and to suggest a stable coordinate system for three-dimensional (3D) cephalometric analysis. Eighteen CT scans were taken and the coordinate system was established using 7 reference points marked by a volume model, with no more than 4 points on the same plane. The 3D landmarks were selected on V works (Cybermed Inc., Seoul, Korea), then exported to V surgery (Cybermed Inc., Seoul, Korea) to calculate the coordinate values. All the landmarks were taken twice with a lapse of 2 weeks. The horizontal and midsagittal planes were constructed and its reproducibility was evaluated. There was no significant difference in the reproducibility of the horizontal reference planes, But, FH planes were more reproducible than other horizontal planes. FH planes showed no difference between the planes constructed with 3 out of 4 points. The angle of intersection made by 2 FH planes, composed of both Po and one Or showed less than $1^{\circ}$ difference. This was identical when 2 FH planes were composed of both Or and one Po. But, the latter cases showed a significantly smaller error. The reproducibility of the midsagittal plane was reliable with an error range of 0.61 to $1.93^{\circ}$ except for 5 establishments (FMS-Nc, Na-Rh, Na-ANS, Rh-ANS, and FR-PNS). The 3D coordinate system may be constructed with 3 planes; the horizontal plane constructed by both Po and right Or; the midsagittal plane perpendicular to the horizontal plane, including the midpoint of the Foramen Spinosum and Nc; and the coronal plane perpendicular to the horizontal and midsagittal planes, including point clinoidale, or sella, or PNS.

A study on horizontal reference planes in lateral cephalogram in Korean adults (한국 성인의 측모두부 수평기준선에 관한 연구)

  • Kim, Kyung-Ho;Baik, Hyoung-Seon;Kim, Gin-Kap
    • The korean journal of orthodontics
    • /
    • v.28 no.5 s.70
    • /
    • pp.865-875
    • /
    • 1998
  • The purpose of this study was to investigate the angle formed by the Sella-Nasion(SN) plane and Frankfort-Horizontal(FH) plane and evaluate the correlation and difference of the FH plane to other horizontal reference planes. Through this study we hope to present a basis for selecting a horizontal reference plae which can be implemented in cephalometric studies and in surgical orthodontic treatment planning. 600 subjects were chosen following a clinical examination md lateral cephlometric X-rays were taken. According to cephalometric analysis the subjects were classified into 3 groups , Skeletal Class I malocclusion or normal occlusion group(male 50, female 50), Skeletal Class II malocclusion group(male 50, female 65) and Skeletal Class III malocclusion group(male 50, female 50). The results were as follows. 1. The angle formed by the SN plane and FH plane showed no difference among the malocclusion groups, but there was a significant sex difference. For males the angle measured was $7.47^{\circ}{\pm}2.40^{\circ}$ whereas for females it was $8.93^{\circ}{\pm}2.72^{\circ}$. 2. The angle formed by the SN plane or FH plane and Mandibular plane was higher in females for all malocclusion groups. This angle in the Skeletal Class I malocclusion group was lower than in the other two groups. 3. There was no difference among the sexes or malocclusion groups considering the angle formed by the FH plane and Palatal plane. 4. The genial angle in the Skeletal Class III malocclusion group was higher than in the Skeletal Class I and Class II malocclusion groups in both sexes.

  • PDF

Quantitative Analyses of Esophageal Cancer Research in Pakistan

  • Qureshi, Muhammad Asif;Khan, Saeed;Ujjan, Ikram Din;Iqbal, Asif;Khan, Ramsha;Khan, Bilal Ahmed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3117-3122
    • /
    • 2016
  • Background: Health-care research is a neglected discipline in Pakistan and research related to esophageal cancer (ranks 9th in Pakistani males and 5th in females) is no exception in this regard. Particularly, there are no data available to delineate the overall status of esophageal cancer epidemiological studies in Pakistan. This study describes the first ever effort to make a systematic quantification, in an attempt to provide a road-map to all stakeholders for designing appropriate epidemiological, diagnostic and therapeutic strategies. Materials and Methods: International (PubMed, ISI Web of Knowledge) and local (PakMedinet) scientific databases as well as Google search engine were searched using specified keywords to extract relevant publication. Well-defined inclusion criteria were implemented to select publications for final analyses. All data were recorded by at least 3 authors and consensus data were entered into and analyzed for descriptive statistics (such as frequencies, percentages and annual growth rates) using Microsoft Excel and SPSS software. Results: A total of 79 publications fulfilled the inclusion criteria including 20 publications for which full texts were not available. Of the 79 publications, 59 (74.6%) were original/research publications, 5 (6.3%) were case reports, 4 (5.1%) were research communications, 2 (2.5%) were review articles, 1 was (1.2%) correspondence and 8 (10.1%) were undefined categories. Only 13 (<20%) cities of Pakistan contributed towards the 79 publications. On average, only 1.9 relevant publications/year were published from 1976 (year of first publication) to the present. Alarmingly, a decline in the annual growth at -4.1% was recorded in the last six years. Conclusions: Esophageal cancer research is largely unfathomed in Pakistan. Urgent/dramatic steps are required by all concerned to address this common (and under reported) cancer of Pakistan.

Estimation of Illuminant Chromaticity by Analysis of Human Skin Color Distribution (피부색 칼라 분포 특성을 이용한 조명 색도 검출)

  • JeongYeop Kim
    • Journal of Platform Technology
    • /
    • v.11 no.5
    • /
    • pp.59-71
    • /
    • 2023
  • This paper proposes a method of estimating the illumination chromaticity of a scene in which an image is taken. Storring and Bianco proposed a method of estimating illuminant chromaticity using skin color. Storring et al. used skin color distribution characteristics and black body locus, but there is a problem that the link between the locus and CIE-xy data is reduced. Bianco et al. estimated the illuminant chromaticity by comparing the skin color distribution in standard lighting with the skin color distribution in the input image. This method is difficult to measure and secure as much skin color as possible in various illumination. The proposed method can estimate the illuminant chromaticity for any input image by analyzing the relationship between the skin color information and the illuminant chromaticity. The estimation method is divided into an analysis stage and a test stage, and the data set was classified into an analysis group and a test group and used. Skin chromaticity is calculated by obtaining skin color areas from all input images of the analysis group, respectively. A mapping is obtained by analyzing the correlation between the average set of skin chromaticity and the reference illuminant chromaticity set. The calculated mapping is applied to all input images of the analysis group to estimate the illuminant chromaticity, calculate the error with the reference illuminant chromaticity, and repeat the above process until there is no change in the error to obtain a stable mapping. The obtained mapping is applied to the test group images similar to the analysis stage to estimate the illuminant chromaticity. Since there is no independent data set containing skin area and illuminant reference information, the experimental data set was made using some of the images of the Intel TAU data set. Compared to Finlayson, a similar theory-based existing method, it showed performance improvement of more than 40%, Zhang 11%, and Kim 16%.

  • PDF

Comparison of midsagittal reference plane in PA cephalogram and 3D CT (3차원 전산화 단층촬영의 Nasion, Sella, Basion으로 구성된 정중 시상 평면과 정면 두부방사선 규격사진의 정중 시상 평면 비교)

  • Cho, Jin-Hyoung;Moon, Ji-Yeon
    • The korean journal of orthodontics
    • /
    • v.40 no.1
    • /
    • pp.6-15
    • /
    • 2010
  • Objective: The aim of this study is to find the most helpful midsagittal reference plane for diagnosis in PA cephalometry compared with 3D CT. Methods: The subjects consisted of 25 adults who showed no facial asymmetry by gross inspection. 3D CT and posteroanterior cephalogram of the subjects were taken. To find the most helpful midsagittal reference plane in PA cephalometry, we considered five kinds of midsagittal planes from which the distances to five landmarks were measured and compared the result with that of 3D CT. The midsagittal plane for 3D CT was determined by the landmarks Nasion, Sella and Basion. Results: PA measurements using the midsagittal reference plane on a perpendicular plane lying through the midpoint of the right and left latero-orbitales was closest to those of 3D CT. Conclusions: It was considered that latero-orbitale perpendicular could be used as the helpful midsagittal reference plane to assess facial asymmetry in PA cephalometry.

Bill of Lading and Effect of Commercial Arbitration Agreement -With Special Reference to English and American Decisions- (선하증권과 중재합의의 효력 - 영ㆍ미의 판례를 중심으로 -)

  • 강이수
    • Journal of Arbitration Studies
    • /
    • v.12 no.2
    • /
    • pp.303-336
    • /
    • 2003
  • Incorporation of an arbitration clause by reference to other documents occurs in many international business transactions. The reference is either to another document that contains arbitration clause or to trading rules which contain the arbitration clause, without the main contract mentioning that arbitration has been agreed upon. In fact, incorporation by reference in to a contract of an arbitration clause set forth in another agreement is deemed valid in any number of circumstances, even when the parties to the two contractual instruments are not the same. Difficulties arise when, instead of an express arbitration provision, a contract contains a clause which refers to the trading rules of a certain trade association, so-called external arbitration clause. The U.S. courts which will presume that the parties intended to arbitrate under a particular set of rules when they expressly mentioned arbitration in their agreement, have sometimes refused to enforce contract clauses that do no more than refer to particular trading rules, even if these rules contain provisions binding the parties to arbitrate their disputes. The courts in such cases tend to be careful in determinig whether intent to arbitrate is present. In maritime contracts, the arbitration clause in a charter party is often referred to in the bill of lading. Such reference usually is held binding upon the parties to the contract of carriage, their knowledge of such practice being presumed. A nonsignatory may compell arbitration against a party to an arbitration agreement when that party has entered into a separate contractual relationship with the nonsignatory which incorporates the existing arbitration clause. If a party's arbitration clause is expressly incorporated into a bill of lading, nonsignatories … who are linked to that bill … may be bound to the arbitration agreement of others. An arbitration clause in a charterparty will be incorporated into a bill of lading if either - (a) there are specific words of incorporation in the bill, and the arbitration clause is so worded as to make sense in the context of the bill, and the clause dose not conflict with the express terms of the bill; or (b) there are general words of incorporation in the bill, and the arbitration clause or some other provision in the charter makes it clear that the clause is to govern disputes under the bill as well as under the charter. In all other cases, the arbitration clause is not incorporated into the bill.

  • PDF

Influence of Internal and External Capacity on Adults' Food Waste Disposal Capacity (내적역량과 외적역량이 성인의 식품 쓰레기 처분에 대한 실천역량에 미치는 영향)

  • Kim, Ji Eun;Choi, Kyoung Sook
    • Korean Journal of Community Nutrition
    • /
    • v.26 no.6
    • /
    • pp.455-466
    • /
    • 2021
  • Objectives: The purpose of this study was to investigate the effects of internal and external capacity on the practical capacity for food waste disposal in adults. Methods: The study subjects were 410 adults who answered a structured questionnaire. The survey was conducted in January 2021. Data were analyzed through descriprive analysis, t-test, ANOVA, and multiple regression analysis using the SPSS Win 24.0. Results: First, in the analysis of internal capacity, attitude (3.95 out of 5 points) scored higher than knowledge (3.59 points). Attitudes showed significant differences according to gender (P < 0.001), age (P < 0.001), and income (P < 0.001). Knowledge showed significant differences according to gender (P < 0.01) and age (P < 0.05). Second, in the analysis of capacity, market constraints (3.73 points) scored the highest, followed by institutional conditions (3.48 points) and reference group (3.36 points). Market constraints differed according to gender (P < 0.001), and institutional conditions differed according to income (P < 0.001). There was a significant difference in the reference group according to the level of education (P < 0.05) and income (P < 0.05). Third, the practical capacity scores appeared in the order of separating discharge behavior, using behavior, purchasing behavior, and leadership behavior. Separating discharge behavior showed significant differences according to gender (P < 0.001), education level (P < 0.05), and income (P < 0.01). Using behavior showed a difference according to gender (P < 0.01), and purchasing behavior showed a significant difference according to income (P < 0.05). Leadership behavior showed no difference according to demographic factors. Fourth, internal capacity and external capacity showed a significant positive relationship with practical capacity. Factors affecting purchasing behavior were knowledge, attitude, institutional conditions, and reference group, and their explanatory power was 53%. Factors influencing using behavior were knowledge, attitude, institutional conditions, and reference group, and had an explanatory power of 37%. Leadership behavior was influenced by institutional conditions and the reference group, with an explanatory power of 31%. Conclusions: Internal capacity, external capacity, and practical capacity show differences according to demographic factors. Factors influencing the practical capacity of adults were knowledge, attitude, institutional conditions, and reference group.

Three-dimensional morphometric analysis of mandibule in coronal plane after bimaxillary rotational surgery

  • Lee, Sung-Tak;Choi, Na-Rae;Song, Jae-Min;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.49.1-49.9
    • /
    • 2016
  • Background: The aim of this report is to present a new reference for aesthetic mandible surgery using three-dimensional cone-beam computed tomography-based treatment planning for orthognathic surgery which can be implemented in surgical planning and perioperative procedure. Methods: To make an objective standard for evaluating aesthetic mandibular outline, we make an aesthetic scoring criteria with consideration of asymmetry, broad mandibular border line, and prominent mandibular angle. Two maxillofacial surgeons and two orthodontists rated their aesthetical evaluation from 1 to 5. Experimental group consisting of 47 female and 38 male patients who had rotational orthognathic two-jaw surgery from 2010 to 2011 were chosen according to aesthetic scoring done by two maxillofacial surgeons and two orthodontists. A high aesthetic score (${\geq}16$) means the facial contour is symmetric, with no broad and narrow aesthetic mandible frontal profiles. Control A group consisted of ten female and ten male patients who had no orthognathic surgery experience and low aesthetic score (${\geq}10$). Control B group consisted of ten female and ten male patients who had no orthognathic surgery experience and had anaesthetic mandibular frontal profile and a high aesthetic score (${\geq}16$). The three-dimensional image of the patient was taken from dental cone-beam CT (DCT) scanning (experimental group and control A group: 6 months DCT after surgery, control B group: 1st visit DCT). Each DCT was reformatted to reorient the 3D image using 3D analyzing program (OnDemand3D, cybermed Inc, CA, USA). After selection of 12 landmarks and the construction of reoriented horizontal, vertical, and coronal reference lines, 15 measurements were taken in 3D analysis of frontal mandibular morphology. Afterwards, horizontal and vertical linear measurements and angular measurements, linear ratio were obtained. Results: Mean $Go^{\prime}_{Rt}-Me^{\prime}-Go^{\prime}_{Lt}$ angular measurement was $100.74{\pm}2.14$ in female patients and $105.37{\pm}3.62$ in male patients. These showed significant difference with control A group in both genders. Ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}-Me^{\prime}$ length to some linear measurements (ratio of $Me^{\prime}-Cd^{\prime}_{Rt}Cd^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Me^{\prime}-Go^{\prime}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$) showed significant difference with control A group in both genders. Conclusion: This study was intended to find some standard measurement of mandible frontal view in 3D analysis of aesthetic patient. So, these potential measurement value may be helpful for orthognathic treatment planning to have more aesthetic and perspective outcomes.