• Title/Summary/Keyword: no reference

Search Result 2,206, Processing Time 0.033 seconds

Study on analytical method and international quality control program for environmental lead (환경 중 납 분석에 관한 국제 정도관리 및 분석 방법 연구)

  • Choi, Inja;Yoon, Chungsik;Kang, Taesun;Yang, Wonsu;Park, Dong Uk;Park, Doo Yong
    • Analytical Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.381-387
    • /
    • 2002
  • In this study, we introduced experience participated in ELPAT (Environmental Lead for Proficiency Analytical Testing) program that is administered by the American Industrial Hygiene Association and EPA. The 126 sample results of total 128 samples met reference value, as a result accepted 'proficient'. The concentration of Pb in air, paint chips, soils and dust wipes are $0.0089{\sim}0.3956mg/m^3$, 0.0500~8.9149%, 29.0${\sim}$1697 mg/kg and $18.00{\sim}900.3{\mu}g/sample$, respectively. The lead in environmental matrix prepared adequate techniques and analysed by flame atomic absorption spectrometry. The lead in air was extracted hydrochloric acid, in paint chips and soils were digested with microwave and hotplate and in dust wipes were prepared microwave digestion. No differences of each preparation techniques was found and all methods were to be proper.

Change in the height of Korean children and adolescents: analysis from the Korea National Health and Nutrition Survey II and V

  • Ryoo, Na Yung;Shin, Ha Young;Kim, Jae Hyun;Moon, Jin Soo;Lee, Chong Guk
    • Clinical and Experimental Pediatrics
    • /
    • v.58 no.9
    • /
    • pp.336-340
    • /
    • 2015
  • Purpose: The mean adult height of Koreans has increased since nationwide anthropological measurements began in 1967. The objective of this study was to evaluate differences in heights of Korean late adolescents and young adults within and between the Second and Fifth Korea National Health and Nutrition Examination Surveys (KNHANES II and V). Methods: Koreans aged ${\leq}22$ years with available measurements of height were enrolled from the KNHANES surveys (KNHANES II: n=3,372 [1,732 males and 1,640 females]; KNHANES V: n=6,190 [3,198 males and 2,992 females]). Differences in the height of KNHANES respondents within and between surveys were evaluated according to age and sex. Results: In KNHANES II, there was no significant difference in height between males aged 17-19 years and those aged 20-22 years ($174.3{\pm}0.5cm$ vs. $174.3{\pm}0.6cm$, P=0.995). Females aged 20-22 years were taller than those aged 17-19 years ($159.8{\pm}0.4cm$ vs. $161.0{\pm}0.4cm$, P=0.017). Females aged 17-19 years were significantly taller in KNHANES V than in KNHANES II ($161.2{\pm}0.3cm$ vs. $159.8{\pm}0.4cm$, P=0.004). Respondents aged 20-22 years were taller in KNHANES V than in KNHANES II, although not significantly so; the difference was $0.3{\pm}0.8cm$ in males (P=0.721) and $0.5{\pm}0.6cm$ in females (P=0.386). Conclusion: Koreans appear to continue growing even in their late adolescence and early twenties. Consequently, it may be necessary to expand the reference age ranges of the Korean growth chart. Additionally, a longitudinal growth survey is needed to determine growth patterns and secular trend in height among Koreans.

A Study on Chest X-ray Using Ancillary Device for Child Radiography (방사선촬영 보조기구를 이용한 어린이 흉부 엑스선 검사에 관한 연구)

  • Rhee, Do-byung;Lee, Somi;Choi, Hyunwoo;Kim, Jong-ki;Lee, Jongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.1
    • /
    • pp.48-54
    • /
    • 2018
  • In this study, We developed a Ancillary device for child radiography for X-ray of children under 5 years old and verified its effectiveness. Chest X-rays of children younger than 5 years of age were performed by Supine method at the position of Table detector, Short - Source to Image Receptor Distance(SID). Existing Supine and Short -SID imaging methods cause many problems, such as errors in image reading and excessive radiation exposure dose to patients, but the use of an Ancillary device for child radiography(ADCR) solves these problems. A total of 160 children were divided into the Upright group using ADCR and Supine group without ADCR. The chest X-ray image was visually evaluated by two radiologists with reference to the European Commission's List of Quality Criteria for Diagnostic Radiographic Images in Pediatrics. The total score of the qualitative evaluation was 5.15% higher in the chest upright method using ADCR than in the chest supine method without ADCR, and the chest upright method score was higher than that of the chest supine method in items 1 to 7. whether infants have deep inspiration or not, 4.87% higher for item 1, whether infants rotate or not and the degree of tilting, 0% higher for the item 2, the reproduction of image from just above apices of lungs to T12/L1, 0% for the item 3, reproduction of the vascular pattern in central 2/3 of the lungs, 6.92% higher for the item 4, reproduction of the trachea and the proximal bronchi, 12.9% higher for the item 5, visually sharp reproduction of the diaphragm and costo-phrenic angles, 10% higher for the item 6, reproduction of the spine and paraspinal structures and visualisation of the retrocardiac lung and the mediastinum, and 3.65% higher for the item 7. Items 2 and 3 showed no statistically significant differences(P > 0.05), and items 1, 4, 5, 6, and 7 showed statistically significant differences(P < 0.05). In conclusion, Upright method using ADCR in pediatric chest X-ray is considered as a good alternative to existing Supine method.

Avoidance of Internal Resonances in Hemispherical Resonator Assemblies from Fused Quartz Connected by Indium Solder

  • Sarapuloff, Sergii A.;Rhee, Huinam;Park, Sang-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.835-841
    • /
    • 2013
  • Modern solid-state gyroscopes (HRG) with hemispherical resonators from high-purity quartz glass and special surface superfinishing and ultrathin gold coating become the best instruments for precise-grade inertial reference units (IRU) targeting long-term space missions. Designing of these sensors could be a notable contribution into development of Korea as a space nation. In participial, 40mm diameter thin-shell resonator from high-purity fused quartz, fabricated as a single-piece with its supporting stem has been designed, machined, etched, tuned, tested, and delivered by STM Co. (ATS of Ukraine) several years ago; an extremely-high Q-factor (upto 10~20 millions) has been shown. Understanding of the best way how to match such a unique sensor with inner glass assembly of the gyro means how to use the high potential in a maximal extent; and this has become the urgent task. Inner quartz glass assembly has a very thin indium (In) layer soldered the resonator and its silica base (case), but effects of internal resonances between operational modal pair of the shell-cup and its side (parasitic) modes can notable degrade the potential of the sensor as a whole, instead of so low level of resonator's intrinsic losses. Unfortunately, there are special combinations of dimensions of the parts (so-called, "resonant sizes"), when intensive losses of energy occurs. The authors proposed to use the length of stem's fixture as an additional design parameter to avoid such cases. So-called, a cyclic scheme of finite element method (FEM) and ANSYS software were employed to estimate different combinations of gyro assembly parameters. This variant has no mismatches of numerical origin due to FEM's discrete mesh. The optimum length and dangerous "resonant lengths" have been found. The special attention has been paid to analyses of 3D effects in a cup-stem transient zone, including determination of a difference between the positions of geometrical Pole of the resonant hemisphere and of its "dynamical Pole", i.e., its real zone of oscillation node. Boundary effects between the shell (cup) and 3D short "beams" (inner and outer stems) have been ranged. The results of the numerical experiments have been compared with the classic model of a quasi-hemispherical shell band with inextensional midsurface, and the solution using Rayleigh's functions of the $1^{st}$ and $2^{nd}$ kinds. To guarantee the truth of the recommended sizes to a designer of the real device, the analytical and FEM results have been compared with experimental data for a party of real resonators. The consistency of the results obtained by different means has been shown with errors less than 5%. The results notably differ from the data published earlier by different researchers.

  • PDF

Changes in Physicochemical and Cook Properties of Kidney Beans During Storage (강남콩의 저장에 따른 이화학적 성질 및 조리특성 변화)

  • 조은자
    • Korean journal of food and cookery science
    • /
    • v.7 no.4
    • /
    • pp.15-22
    • /
    • 1991
  • Changes in cooking properties of kidney beans A (reddish purple), B (mosaic), and C (pale yellow) during storage at $4^{\circ}$, $20^{\circ}$ and $30^{\circ}C$ for 5 months were examined. The weight and volume gains of raw beans during soaking at $30^{\circ}C$ were the greatest in kidney bean A followed by B and C, which were decreased from 3 months storage at $30^{\circ}C$. The weight gain, solid loss and hardness of cooked beans at $100^{\circ}C$ for 40 min decreased from 3 months of storage at $30^{\circ}C$ in all samples. The amylograms of whole kidney bean flours showed no peak and continuous increase of viscosity during heating. The kidney bean A showed the higher values in all reference points than kidney beans B and C which had similar amylogram patterns.

  • PDF

Genetic Variation in the Immunoregulatory Gene of Adenovirus Type 3 (3형 아데노바이러스의 면역조절 유전자 다양성)

  • Choi, Eun Hwa;Kim, Hee Sup;Lee, Hoan Jong
    • Pediatric Infection and Vaccine
    • /
    • v.16 no.2
    • /
    • pp.199-204
    • /
    • 2009
  • Purpose : Various proteins encoded in the early region 3 (E3) of adenoviruses protect cells from being killed by cytotoxic T cells and death-inducing cytokines. We sought to find out whether the genetic heterogeneity of the E3 gene might contribute to the molecular diversity of adenoviruses. Methods : Sequences in the E3 region were analyzed for 14 adenovirus type 3 (Ad3) strains that were isolated from children with lower respiratory tract infections in the Seoul National University Children's Hospital during the period 1991-2000. Full-length adenoviral DNA was purified from the infected A549 cell lysates using a modified Hirt procedure. Results : There was 98% homology between 14 Korean Ad3 strains with a reference strain (M15952). Homology within the Korean Ad3 strains was 98.7%. Variation was found in the region of transcripts 20.1 kDa, 20.6 kDa, truncated 7.7 kDa, 10.3 kDa, 14.9 kDa, and 15.3 kDa. In particular, all 14 Korean strains showed a missense single point mutation at the start codon of the truncated 7.7 kDa. In addition, a deletion was found in the truncated 7.7 kDa region by 58 base pairs in 10 strains and 94 base pairs in 4 strains. Variations in amino acids were observed in the receptor internalization and degradation complex (10.3 kDa/14.9 kDa) which stimulates the clearance from the cell surface and subsequent degradation of the receptors for the Fas ligand and TRAIL, while no variations were observed in another immunoregulatory transcript, 19 kDa. Conclusion : Sequence analysis of the immunoregulatory region of adenovirus E3 shows that genetic heterogeneities are related to genome type patterns.

  • PDF

Location Studies of Prostate Volume Measurement by using Transrectal Ultrasonography: Experimental Study by Self-Produced Prostate Phantom (경직장초음파를 이용한 전립선 볼륨측정 시의 위치 연구: 전립선모형 제작과 실험)

  • Kim, Yun-Min;Yoon, Joon;Byeon, II-kyun;Lee, Hoo-Min;Kim, Hyeong- Gyun
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.437-442
    • /
    • 2015
  • Accurate volume measurement of the prostate is a significant role in determining the result of diagnosis and treatment of benign prostate hyperplasia. The purpose of this study was to determine, when measuring prostate volume by TRUS, whether location is more accurately determined by transaxial or longitudinal scanning. With reference to the patient's image, it was produced six prostate model. It compares the actual volume and the measurement volume, and find the optimal measurement position of each specific model. Prostate volume measured by TRUS closely correlates with prostate phantom volume. There was no significant difference(p = .156). To measure the accurate volume of prostate with focal protrusion, its length should be measured exclude the protrusions.

BIOLOGICALLY-BASED DOSE-RESPONSE MODEL FOR NEUROTOXICITY RISK ASSESSMENT

  • Slikker, William Jr.;Gaylor, David W.
    • Toxicological Research
    • /
    • v.6 no.2
    • /
    • pp.205-213
    • /
    • 1990
  • The regulation of neurotoxicants has usually been based upon setting reference doses by dividing a no observed adverse effect level (NOAEL) by uncertainty factors that theoretically account for interspecies and intraspecies extraploation of experimental results in animals to humans. Recently, we have proposed a four-step alternative procedure which provides quantitative estimates of risk as a function of dose. The first step is to establish a mathematical relationship between a biological effect or biomarker and the dose of chemical administered. The second step is to determine the distribution (variability) of individual measurements of biological effects or their biomarkers about the dose response curve. The third step is to define an adverse or abnormal level of a biological effect or biomarker in an untreated population. The fourth and final step is to combine the information from the first three steps to estimate the risk (proportion of individuals exceeding on adverse or abnormal level of a biological effect or biomarker) as a function of dose. The primary purpose of this report is to enhance the certainty of the first step of this procedure by improving our understanding of the relationship between a biomarker and dose of administered chemical. Several factors which need to be considered include: 1) the pharmacokinetics of the parent chemical, 2) the target tissue concentrations of the parent chemical or its bioactivated proximate toxicant, 3) the uptake kinetics of the parent chemical or metabolite into the target cell(s) and/or membrane interactions, and 4) the interaction of the chemical or metabolite with presumed receptor site(s). Because these theoretical factors each contain a saturable step due to definitive amounts of required enzyme, reuptake or receptor site(s), a nonlinear, saturable dose-response curve would be predicted. In order to exemplify this process, effects of the neurotoxicant, methlenedioxymethamphetamine (MDMA), were reviewed and analyzed. Our results and those of others indicate that: 1) peak concentrations of MDMA and metabolites are ochieved in rat brain by 30 min and are negligible by 24 hr, 2) a metabolite of MDMA is probably responsible for its neurotoxic effects, and 3) pretreatment with monoamine uptake blockers prevents MDMA neurotoxicity. When data generated from rats administerde MDMA were plotted as bilolgical effect (decreases in hippocampal serotonin concentrations) versus dose, a saturation curve best described the observed relationship. These results support the hypothesis that at least one saturable step is involved in MDMA neurotoxicity. We conclude that the mathematical relationship between biological effect and dose of MDMA, the first step of our quantitative neurotoxicity risk assessment procedure, should reflect this biological model information generated from the whole of the dose-response curve.

  • PDF

A Study on the Radiation Dose of $^{131}I$ in the Thyroid Gland during the Treatment of Hyperthyroidism (갑상선 기능항진증의 $^{131}I$ 치료시 갑상선 조사량에 관한 연구)

  • Suh, Hwan-Jo;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.9 no.1
    • /
    • pp.59-71
    • /
    • 1975
  • 53 patients with hyperthyroidism have been analyzed with special reference to therapeutic response to radioactive iodine ($^{131}I$) treatment. Mean effective half-life, 24 hour uptake rate and radiation dose of $^{131}I$ in hyperthyroid patients included in this study were respectively. 1. Mean effective half-life of $^{131}I\;was\;4.7{\pm}1.5$ days in the tracer dose and $5.0{\pm}1.5$ days in the therapeutic dose. 2. Mean 24 hour uptake rate of $^{131}I\;was\;72.7{\pm}11.1%$ in the tracer dose and $73.4{\pm}12.3%$ in the theapeutic dose. 3. Mean radiation dose of $^{131}I\;was\;5,319{\pm}2,648$ RAD as predicted and $5,692{\pm}2,843$ RAD as actual. A single dose of radioactive iodine treatment was satisfactory in 34 patients (radioiodine sensitive) and multiple doses of radioactive iodine treatments were required in 19 patients (radioiodine resistant). A radioiodine resistant group of patients with hyperthyroidism was distinctively characteristic in the following aspects. 1. Mean thyroid weight calculated in the resistant group ($63.9{\pm}14.0gm$) was significantly (p<0.01) greater than that of the sensitive group ($46.6{\pm}13.3gm$). 2. Mean 24 hour uptake rate of the tracer dose in the resistant group ($67.3{\pm}10.7%$) was significantly (p<0.01) lower than that of the sensitive group ($75.7{\pm}10.5%$). 3. Mean 24 hour uptake rate of the therapeutic dose in the resistant group ($68.5{\pm}13.7%$) was significantly (p<0.05) lower than that of the sensitive group ($76.1{\pm}10.9%$). 4. Mean predicted radiation dose, of $^{131}I$ in the resistant group ($3,684{\pm}1,745$ RAD) was significantly (p<0.01) lower than that of the sensitive group ($6,232{\pm}2,683$ RAD). 5. Mean actual radiation dose of $^{131}I$ in the resistant group ($4,100{\pm}1,691$ RAD) was significantly (p<0.01) lower than that of the sensitive group ($6,582{\pm}3,024$ RAD). 6. No significant difference was detected in terms of effective half-life of $^{131}I$ among the groups (p>0.05). 7. The average mean % difference of effective half-life, uptake rate and radiation dose measured following the tracer and therapeutic dose of $^{131}I$ were not statistically significant (p>0.05). Therefore effective half-life, uptake rate and radiation dose of the therapeutic dose of $^{131}I$ were readily predictable following the tracer dose of $^{131}I$. 8. It is concluded that the possibility of resistance to radioactive iodine treatment may be anticipated in patients with thyroid gland large in size and compromised $^{131}I$ uptake rate.

  • PDF

Effect of Organic Fertilizer Levels on Dry Matter Yield, Nitrogen Fixation and Transfer on the Barley and Pea Mixtures (보리.완두 포장에서 유기질비료 시용 수준이 건물수량과 질소 고정 및 이의 이동에 미치는 영향)

  • Lee, Hyo-Won
    • Korean Journal of Organic Agriculture
    • /
    • v.21 no.3
    • /
    • pp.381-389
    • /
    • 2013
  • In order to study the effect of organic fertilizer on dry matter (DM) yield, nitrogen fixation and transfer from pea to barley, an experiment was carried out from May to June in 2008 in Incheon. A completely randomized block design with three replications was used for the experiment and one reference plot assigned each treatment for nitrogen fixation evaluation. Seeding mixture was 40kg barley and 80kg pea per ha. N rate of 40, 80 and 120kg/ha as organic fertilizer was applied at seeding. The equivalent of 1kg per ha as $(15NH_4)_2SO_4$ Solution at 99.8 atom N was applied to the plots ($30{\times}20cm$) at mid April. Forage was harvested from each plot in ripening stage at ground level and separated into barley and pea. Nitrogen fixation was 32.4%, 23.4% and 0% at three different organic N levels. Transfer rate were from 47.6% to 21.8% in difference method and 24.6% and 21.4% on $^{15}N$ dilution method. N Transfer amount were from 92.8kg/ha to 41.9kg/ha on difference method and 47.3kg in the 40kg N plots and 49.7kg in the 80kg N plots on $^{15}N$ dilution method but there was no N transfer in 120kg N organic fertilizer plots. Benefit from increased organic fertilizer was not clear in terms of nitrogen fixation and transfer from pea to barley in barley and pea mixtures.