• Title/Summary/Keyword: no reference

Search Result 2,206, Processing Time 0.034 seconds

Comparison Study about Surface Mapping of Motor Points in Biceps Brachii Muscle Using Surface EMG and Electric Probe (표면 근전도와 전기 탐침기를 이용한 상완이두근의 운동점 표지 비교 연구)

  • Park, Jaewon;Keum, Dongho
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.28 no.1
    • /
    • pp.85-96
    • /
    • 2018
  • Objectives This study was performed to compare the electrical methods of motor points mapping using surface EMG and electric probe (Pointer Excel II). Methods 32 healthy adults (male 16, female 16) were selected. and classified into two groups; surface EMG group, electric probe (Pointer Excel II) group. In surface EMG group, motor points were searched by recoding the compound muscle potentials. In electric probe (Pointer Excel II) group, motor points were searched by scanning the skin with Pointer Excel II at low level stimulation. The locations of the motor points were expressed as X and Y values in relation to the reference line. The horizontal reference line was set as elbow crease and the vertical reference line was set as the line connecting coracoid process to the center of the horizontal reference line. The data was analyzed by 'Independent T-test' and 'equivalence test'. Results 1. The motor points of short head and long head of biceps brachii muscle were located at about 2/3 length of the vertical reference line from coracoid process and about 1/5~1/4 length of the half of the horizontal reference line from the vertical reference line in both group. 2. The motor points of the short head were located more distally and close to the vertical reference line (p<0.001). 3. In surface EMG group, the motor points of the long head were located more laterally in the female than male. And the motor points of the long head were located more distally in the left side than right side (p<0.05). In electric probe (Pointer Excel II) group, similar tendency was observed but there was no statistically significant difference (p>0.05). 4. As a result of the equivalence test between surface EMG group and electric probe (Pointer Excel II) group, the confidence intervals of the difference were within the equivalence limit. Therefore, the locations of the motor points searched by two ways are equa l (p>0.05, equivalence interval=3%). Conclusions The results indicate that electric probe (Pointer Excel II) can be used to search the motor points instead of surface EMG. This might improve the clinical efficiency when using the motor points to treat muscle dysfunction.

Early Wittgenstein's Criticism of Frege's Theory of Meaning (전기 비트겐슈타인의 프레게 의미이론 비판)

  • Park, Jeong-Il
    • Korean Journal of Logic
    • /
    • v.16 no.3
    • /
    • pp.347-380
    • /
    • 2013
  • In this paper I will try to show how Wittgenstein criticized Frege's theory of meaning. Frege's theory of meaning can be compressed as sense-reference theory. Frege distinguishes between sense and reference on all the linguistic expressions. In particular, he regards that a sentence has sense and reference. This distinction was raised from, so to speak, the problem of identity sentences. Wittgenstein's "fundamental thought" of Tractatus Logico-Philosophicus is the key of his direct criticism of Frege's sense-reference theory. That is, it is an attack on Frege's thought that the reference of a sentence is a truth value and truth values are "objects themselves" (in Frege's meaning). According to Wittgenstein, such an object does not exist and according to his picture theory, the function of a name and that of a proposition are fundamentally different. By the way, Frege can reply justly to this criticism that it is insufficient. In short, Frege's 'sense' and 'reference' etc, are the technical terms. Hence Wittgenstein's decisive criticism of Frege's theory consists in accusing his theory of logical flaws. There is an another route to the sense and reference of a sentence which Frege introduces. In discourses of judgement stroke and content stroke in his Begriffsshrift and in those of horizontal stroke since his "Function and Concept", Frege deals with the sense and reference of a sentence. Wittgenstein criticize that the sense of a complex sentence such as ~p would by no means be determined by Frege's determination.

  • PDF

Ferromagnetic Resonance of Magnetic Tunnel Junctions with an Exchange Biased Synthetic Ferrimagnetic Reference Layer (교환 바이어스 인위적 준강자성 기준층을 포함한 자기 터널 접합의 강자성 공명)

  • Yoon, Jung-Bum;You, Chun-Yeol;Jung, Myung-Hwa
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.4
    • /
    • pp.121-126
    • /
    • 2011
  • Spin dynamics of magnetic tunnel junctions with free and fixed reference layers is investigated by ferromagnetic resonance micromagnetic simulations. First, in magnetic tunnel junctions with an exchange biased synthetic ferrimagnetic reference layer, a magnetization direction of each layer and the tunneling magnetoresistance are calculated for a DC magnetic field. To investigate the spin exciting modes in magnetic tunnel junctions, we simulate the ferromagnetic resonance frequency spectra with small RF magnetic fields. Exciting modes of the tunneling magnetoresistance calculated by an included angle between free and reference layers is interpreted from those of each layer. Spin exciting modes are different according to a signs of the DC magnetic field. In a negative magnetic field, FMR frequency spectra of free and reference layers are well elucidated by the modified Kittel's equation. However, in a positive magnetic field, there is no simple analytic solution related to FMR frequency spectra due to the coupled modes. Since ferromagnetic layers in magnetic tunnel junctions are interactive each other, careful considerations of the reference and fixed layer as well as the free layer are required for understanding on the spin dynamics of magnetic tunnel junctions with an exchange biased synthetic ferrimagnetic reference layer.

Liver Size Measurement Method by Ultrasonography and Reference Range based on Normal Adult Physique Index (초음파검사에 의한 간 크기 측정방법 및 정상 성인의 체격지수별 참조범위)

  • Kim, Yong-Kyun;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.13-24
    • /
    • 2018
  • Liver size is an important component in the diagnosis and follow-up of diffuse liver disease when testing for liver disease using ultrasonography. However, difficulties lies in determining the presence of hepatomegaly and liver atrophy because the method used for measuring liver size differs from one examiner to another and there is no relevant standard based on body build. The present study aims to propose a more objective method for liver size measurement and a reference range based on body build. A total of 260 normal adults (130 males, 130 females) participated in the study. Ultrasonography was performed in all participants to measure the size of the right lobe, left lobe, quadrate lobe, and caudate lobe of liver. Based on Physique Index(PI), a value derived from multiplying weight(kg) by height($m^2$), size of physique was divided into three groups including Group I with PI<150, Group II with $150{\leq}PI{\leq}250$, and Group III with PI>250. Thus, mean liver size by PI and a reference range with 95% reliability were suggested. The superoinferior diameter of right lobe was $12.34{\pm}1.18cm$ in males and $11.07{\pm}0.93cm$ in females, and its reference range was 10.64~11.0cm for Group I, 11.78~12.12cm for Group II, and 13.02~13.84cm for Group III. The anteroposterior diameter(T) of left lobe was $5.93{\pm}1.09cm$ in males and $5.18{\pm}0.99cm$ in females, and its reference range was 4.77~5.17cm for Group I, 5.49~5.79cm for Group II, and 6.68~7.44cm for Group III. The transverse diameter was $3.51{\pm}0.60cm$ in male participants and $3.42{\pm}0.49cm$ in female participants and its reference range was 3.29~3.51cm for Group I, 3.36~3.55cm for Group II, and 3.52~4.0cm for Group III. The caudate lobe index was $11.65{\pm}2.88cm^2$ in males and $9.62{\pm}2.18cm^2$ in females and its reference range was $8.83{\sim}9.75cm^2$ for Group I, $10.62{\sim}11.47cm^2$ for Group II, and $11.89{\sim}14.26cm^2$ for Group III. As a basic measurement method of liver size, the present study suggests measuring the superoinferior diameter for right liver lobe, the anteroposterior diameter for left liver lobe, the transverse diameter for quadrate lobe, and the caudate lobe index for caudate lobe. It is expected that this method along with its relevant reference range can be used as useful indicators in determining hepatomegaly and liver atrophy upon the diagnosis and follow-up testing of diffuse liver disease.

A neural network approach to defect classification on printed circuit boards (인쇄 회로 기판의 결함 검출 및 인식 알고리즘)

  • An, Sang-Seop;No, Byeong-Ok;Yu, Yeong-Gi;Jo, Hyeong-Seok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.2 no.4
    • /
    • pp.337-343
    • /
    • 1996
  • In this paper, we investigate the defect detection by making use of pre-made reference image data and classify the defects by using the artificial neural network. The approach is composed of three main parts. The first step consists of a proper generation of two reference image data by using a low level morphological technique. The second step proceeds by performing three times logical bit operations between two ready-made reference images and just captured image to be tested. This results in defects image only. In the third step, by extracting four features from each detected defect, followed by assigning them into the input nodes of an already trained artificial neural network we can obtain a defect class corresponding to the features. All of the image data are formed in a bit level for the reduction of data size as well as time saving. Experimental results show that proposed algorithms are found to be effective for flexible defect detection, robust classification, and high speed process by adopting a simple logic operation.

  • PDF

Adolescent nutrition: what do pediatricians do?

  • Ryoo, Eell
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.7
    • /
    • pp.287-291
    • /
    • 2011
  • Multiple psychosocial problems and many chronic diseases of adulthood can be influenced by adolescent nutritional problems. In Korea, adolescent obesity and obesity related health risks have been increased and insufficient intakes of nutrients, such as calcium, iron and potassium, and distorted thinking about obesity are also common. However there are no comprehensive countermeasure because of the excessive burden of studies and the lack of community interest. And the nutrition guidelines that is suitable for Korean adolescent leaves something to be desired, and the pediatrician's concern is lacking yet. In the Korean dietary reference intakes 2010 that was revised according to the 2007 Korean National Growth Chart and 2007 Korean National Health and Nutrition Examination Survey, the range for adolescents is changed to the age 12-18 and dietary reference intakes of some nutrients mainly with vitamin D is changed. Recently several researches, about how school nutrition policies and media effect on eating habits and the weight concerns, and influences of public nutrition policies and fast food commercials have been actively studied to improve adolescent nutritive conditions. In this review, I summarize the dietary reference intakes for Korean adolescents that were revised in 2010, and current studies about the adolescent nutrition.

The Contribution of The Research on "Somunchajujipso(素問次注集疏)" and "Somun(素問)" ($\ll$소문차주집소(素問次注集疏)$\gg$ 대(對) $\ll$소문(素問)$\gg$ 연구적공헌(硏究的貢獻))

  • Guo, Xiu-Mei
    • Journal of Korean Medical classics
    • /
    • v.22 no.4
    • /
    • pp.51-54
    • /
    • 2009
  • While we study the book "Somun(素問)", we have to take Wangbing(王冰) Note as reference, which has to be understood by later generation on reading the book Sin-gyojeong(新校正) of Imeok(林億) from Song dynasty. At the final period of Edo in Japan, the famous Han medical expert, Yamada(山田) Gyoukou(業廣) sought a complete new way to compile a book named "Somunchajujipso(素問次注集疏)", a notes and commentaries work combined the original text of "Somun(素問)", Wangbing(王冰) Note and Sin-gyojeong(新校正) by taking the reference of generations medical books and notes both China and Japan. There have been many books to give notes on "Somun(素問)" in many generations, but less of them giving notes to the original text, but to Wangbing Note a little bit at most. In "Somunchajujipso", textual research and notes are given as a special example to the forward, original text and explanation part of "Somun", Song dynasty edition. Especially the detail explanation to the forward part of Imeok(林億), no one has done better than Gyoukou(業廣) until now. It sufficiently shows Gyoukou's(業廣) enriched knowledge accumulated by years hard research in Confucian classics, history and medical books, which enable it a worthy reference statement. The issued of the book "Somunchajujipso(素問次注集疏)" expands a new area for the research of "Somun" and present new research improvement of "Somun" in Japan.

  • PDF

Application of enhanced Reference Stress Method to Nuclear Piping LBB Analysis : Finite Element Validation (원자력 배관의 파단전누설 해석을 위한 개선된 참조응력법의 수치해석적 검증)

  • Heo, Nam-Su;Kim, Yun-Jae;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.4
    • /
    • pp.741-747
    • /
    • 2001
  • Three-dimensional, elastic-plastic finite element analyses for circumferential through-wall cracked pipes are performed using actual tensile data of stainless steels, for two purposes. The first one is to validate the recently-proposed enhanced reference stress (ERS) method to estimate the J-integral and COD for circumferential through-wall cracked pipes. The second one is to compare those results with the GE/EPRI estimations. It is found that the J-integral and COD estimations according to the GE/EPRI method can be very sensitive to how the stress-strain data are fitted using the Ramberg-Osgood relation. Moreover, no tendency can be found regarding the most appropriate fitting range for the Ramberg-Osgood fit. On the contrary, the J-integral and COD estimations based on the ERS method give more accurate results than the GE/EPRI estimation. The present results provide confidence in applying the proposed method to the Leak-Before-Break(LBB) analysis.

Sway Control of a Container Crane ( Part I ) : Modeling, Control Strategy, Error Feedback Control Via Reference Velocity Profiles (컨테이너 크레인의 흔들림 제어 ( Part I ) : 모델링, 제어전략, 기준선도를 통한 오차 피이드백 제어)

  • Hong, Keum-Shik;Sohn, Sung-Chull;Lee, Man-Hyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.1
    • /
    • pp.23-31
    • /
    • 1997
  • The sway control problem of pendulum motion of a container hanging on a Portainer Crane, which transports containers from a container ship to trucks, is considered in the paper. The equations of motion are obtained through the Lagrange mechanics and simplified for control purposes. Considering that the fast traveling of trolley and no residual swing motion of the container at the end of acceleration and deceleration are crucial for quick transportation, several velocity patterns of trolley movement including the time-optimal control are investigated. Incorporating the change of rope length, a reference swing trajectory is introduced in the control loop and the error signal between the reference sway angle and the measured sway angle is feedbacked. Proposed control strategy is shown to be robust to disturbances like winds and initial sway motion.

  • PDF

Bioequivalence Test of Biphenyl Dimethyl Dicarboxylate Products (비페닐디메칠디카르복실레이트 제제의 생물학적 동등성 시험)

  • Han, Sang-Soo;Ham, Seong-Ho;Sohn, Dong-Hwan;Kim, Jae-Baek
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.2
    • /
    • pp.67-72
    • /
    • 1994
  • Bioequivalence (BE) test of biphenyl dimethyl dicarboxylate (DDB) tablets was performed. Normal healthy male volunteers (n = 20) were randomly divided into 2 groups, and reference $(Nissel{\circledR})$ and test $(Livital{\circledR})$ tablets of DDB $(25mg{\times}8\;Tab.\;= \;200\;mg)$ were given orally by balanced two-period cross-over design. The serum concentration was determined by high performance liquid chromatography. The pharmacokinetic parameters, AUC, $C_{max}$, and $T_{max}$ obtained after drug administration were statistically analyzed. Statistical evaluation of the data involved an analysis of variance (ANOVA) for cross-over design. The results were within 20% differences of mean value in AUC, $C_{max}$, and $T_{max}$ between reference and test tablets. The results of ANOVA showed no significant differences for "between group or subject" and "period". The test tablet was bioequivalent with the reference tablet in the AUC, $C_{max}$, and $T_{max}$.

  • PDF