• Title/Summary/Keyword: no reference

Search Result 2,206, Processing Time 0.037 seconds

Geoid Height Estimation Using Rail-road Reference Points (철도기준점을 활용한 지오이드고의 추정)

  • Heo, Joon;Song, Yeong-Sun;Kim, Sung-hoon;Moon, Cheung-Kyun
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.4
    • /
    • pp.499-505
    • /
    • 2009
  • This paper evaluated applicability of railroad reference points for determinating geoid heights. For this research, reference points on the Honam express raildroad which contain ellipsoid heights estimated by GPS/Leveling and orthometric heights by leveling were used. Geoid heights were calculated uisng orthometric and ellipsoid heights of 360 railroad reference points, and the RMSE's with respect to different intervals of reference points were analysed which were induced by interpolation methods. The results showed that no significant difference of RMSE's among interpolation. methods. RMSE's of 0-4km interval of reference points were determined within 2cm and 5-8km were within 3cm. Also, this research confirmed that GPS leveling with Geoid model is not auurate enough to be used for railroad surveying as yet.

Teratogenicity of the Extracts of Crude Drugs (생약(生藥)의 최기성(崔畸性)에 관한 연구(硏究))

  • Lee, Eun-Bang
    • Korean Journal of Pharmacognosy
    • /
    • v.13 no.3
    • /
    • pp.116-121
    • /
    • 1982
  • In order to investigate the side-effects of crude drugs, twenty drugs have been tested for the teratogenic effect in rats. Among seven drugs contained alkaloid as their ingredients, no one showed teratogenic effect, but Veratri rhizoma showed embryo-toxic as revealed by severe retardation in growth of the fetuses. The other thirteen drugs which have been used freguently in oriental medicines exhibited no teratogenic effect. Cyclophosphamide used as a reference compound showed severe malformation and retardation in the growth of rat fetuses. These findings suggest that the drug extracts adopted for the study might have no teratogenic effect in the rats.

  • PDF

Fabrication and Characteristics of SAW Gas Sensor (SAW 가스센서의 제작 및 특성)

  • Jun, C.B.;Park, H.D.;Choi, D.H.;Lee, D.D.
    • Journal of Sensor Science and Technology
    • /
    • v.3 no.1
    • /
    • pp.40-45
    • /
    • 1994
  • $112^{\circ}$ rot. x-cut $LiTaO_{3}$ wafer was used as the substrate of SAW gas sensor. Dual delay line SAW device with IDTs which consist of the reference delay line and the sensing delay line was fabricated using photolithigraphy. Each IDTs had 10 finger pairs and finger spacing is 10 microns. One delay line channel is the reference, while the second is the sensing channel with Pb-phthalocyanine film in the propagation path. Pb-phthalocyanine film which is p-type organic semiconductor was evaporated in $10^{-5}$ torr vacuum using shadow mask selectively. Dual delay line oscillator was constructed by using the rf amplifier and AGC. Frequency of the IDTs had the range of $87{\sim}$89 MHz oscillation frequency. Oscillation frequency shifts were investigated as a function of the temperature and the concentration of $NO_{2}$ gas.

  • PDF

Validity of Horizontal Reference Planes on Cone-Beam Computed Tomography Generated Postero-Anterior Cephalogram (Cone-beam CT영상으로부터 얻어진 정모두부방사선사진에서 수평기준선의 설정)

  • Kang, Hee-Jea;Kim, Jong-Ryoul;Kim, Yong-Il
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.4
    • /
    • pp.346-351
    • /
    • 2011
  • Purpose: The purpose of this study was to measure the angular differences between the horizontal reference planes on the CBCT generated PA cephalogram and the modified interpupillary plane, which was usually used in the clinical examination, and to evaluate the validity of the horizontal reference planes. Methods: The CBCT generated PA cephalogram was used to measure the angles between the FH, Lo and IP planes. The subjects consisted of 42 patients with facial asymmetry (males: 21, females: 21, mean-age: 21.6 years). The control groups were also assessed (males: 10, females: 10, mean-age: 23.8 years). The distance of the interpupil was measured on the soft-tissue volume rendered image. The angular differences were statistically analyzed using the $Mann-Whitney$ $U$ $test$ for inter-group comparisons and the $Friedman$ $test$ for intra-group comparisions. Results: The angle between the FH plane and IP plane (the angle of the FH-IP line) showed a statistically significant difference between the two groups ($p$ <0.05). There was no statistical differences between each angle (angle of the FH-IP line, angle of the FH-Lo line, angle of the Lo-IP line) on the intra-group comparision ($p$ >0.05). Conclusion: The angle between the Lo line and IP line (angle of the Lo-IP line) showed no statistically significant difference in both the control and asymmetry groups. Therefore, the Lo line could be used as a horizontal reference plane in CBCT generated PA cephalograms.

Characteristics of a new Pleurotus eryngii cultivar, Aeryni 6 (큰느타리버섯 신품종 '애린이6'의 생육특성)

  • Lee, Song Hee;Kim, Min-Keun;Ryu, Jae-San
    • Journal of Mushroom
    • /
    • v.16 no.1
    • /
    • pp.16-21
    • /
    • 2018
  • In order to breed a new Pleurotus eryngii cultivar exhibiting intermediate size and rapid growth, single crosses between $24{\times}46$ and KNR2539 were performed. The resulting new cultivar, $17{\times}15$, was chosen based on the required days to harvest (15.4 days), quality (7.5), and yield (81.5 g/850 cc bottle) obtained in a preliminary test. The strain was named Aeryni 6 and cultivated at mushroom farms on a large scale for comparison with the reference cultivar Kenneutari No. 2. The yield of Aeryni 6 (76.0 g) was 113.0% compared with the reference cultivar, Kenneutari No. 2, and its quality was 6.8, while that of the reference strain was 5.7. An independent t-test revealed significant differences between the days for harvest, yield, and quality of the two cultivars. The new and reference cultivars were discriminated by PCR amplification of URP2 and URP11 and a confrontation cultivation.

The Effect of Volume Reduction on Computed Treatment Planning during Head and Neck IMRT and VMAT (두경부 IMRT 및 VMAT 시 체적 감소가 전산화치료계획에 미치는 영향)

  • Ki-Cheon Um;Gha-Jung Kim;Geum-Mun Back
    • Journal of radiological science and technology
    • /
    • v.46 no.3
    • /
    • pp.239-246
    • /
    • 2023
  • In this study, we assessed the effect of reduction of tumor volume in the head and neck cancer by using RANDO phantom in Static Intensity-Modulated Radiation Therapy (S-IMRT) and Volumetric-Modulated Arc Therapy (VMAT) planning. RANDO phantom's body and protruding volumes were delineated by using Contour menu of Eclipse™ (Varian Medical System, Inc., Version 15.6, USA) treatment planning system. Inner margins of 2 mm to 10 mm from protruding volumes of the reference were applied to generate the parameters of reduced volume. In addition, target volume and Organ at Risk (OAR) volumes were delineated. S-IMRT plan and VMAT plan were designed in reference. These plans were assigned in the reduced volumes and dose was calculated in reduced volumes using preset Monitor unit (MU). Dose Volume Histogram (DVH) was generated to evaluate treatment planning. Conformity Index (CI) and R2 in reference S-IMRT were 0.983 and 0.015, respectively. There was no significant relationship between CI and the reduced volume. Homogeneity Index (HI) and R2 were 0.092 and 0.960, respectively. The HI increased when volume reduced. In reference VMAT, CI and R2 were 0.992 and 0.259, respectively. There was no relationship between the volume reduction and CI. On the other hand, HI and R2 were 0.078 and 0.895, respectively. The value of HI increased when the volume reduced. There was significant difference (p<0.05) between parameters (Dmean and Dmax) of normal organs of S-IMRT and VMAT except brain stem. Volume reduction affected the CI, HI and OAR dose. In the future, additional studies are necessary to incorporate the reduction of the volume in the clinical setting.

A Study on a Computation of the Meridian Length (자오선 길이의 계산에 관한 연구)

  • 박경환;김정희;안기원
    • Proceedings of the Korean Association of Geographic Inforamtion Studies Conference
    • /
    • 1997.12a
    • /
    • pp.35-50
    • /
    • 1997
  • In geodesy, a calculation of the meridian length is a basic thing. Its principle is very simple, but no exact closed formula exists and its expression has rather long terms. In Korea, the formula has been seemingly adapted from those of Japan which also use the Bessel ellipsoid as a reference. However, a formula from a noticeable reference of Japan is found to have wrong coefficient values. In this study, a formula for the meridian length with correct coefficient values is suggested and the results on different computing bases are also shown. This formula has terms simpler than the one in the Korean Surveying Act (Law) which has the same coefficients in that Japanese reference.

  • PDF

Measurements of the In-Plane Vibration Intensity of a Beam Using an Reference Accelerometer (기준 가속도계를 이용한 보의 면내 진동인텐시티 측정)

  • Kim, C.R.;Kil, H.G.;Jeon, J.S.;Hong, S.Y.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.848-851
    • /
    • 2002
  • In this paper, an experimental method using a reference accelerometer has been developed to measure the in-plane vibration intensity of a beam. It has the advantages of reducing accelerometer phase error comparing with the cross spectral intensity measurement technique using an accelerometer array. It needs no measurement of the input force required in the frequency response method using the only one accelerometer This method has been used to measure the in-plane vibration intensity over the beam. The result has been compared with an input power and the vibration intensity obtained with other methods. It showed that the present experimental method can be effectively used to measure the structural in-plane vibration intensity.

  • PDF

CONSTRUCTION OF A ROBUST CMPEMSATION CONTROLLER

  • Hyogo, Hidekazu;Kamiya, Yuji;Shibata, Koji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1994.10a
    • /
    • pp.471-476
    • /
    • 1994
  • In this paper a new controller is proposed which gives the resultant system the appointed input-output properties, low sensitivity and robust stability. The proposed controller consists of a reference model and a robust compensator. The reference model determines the input-output properties of the total system and is constructed by using the nominal model of the plant. We can design the reference model by applying design techniques which pay attention to steady robustness and no attention to sensitivity and robust stability, and need all state variables of the plant. The robust compensator is obtained as a solution of the mixed sensitivity problem in H infinity control theory. Therefore, low sensitivity and robust stability are guaranteed in the resultant system. The simulation experiments show that the proposed controller is effective and useful.

  • PDF