• Title/Summary/Keyword: no insulation

Search Result 303, Processing Time 0.024 seconds

Properties of Temperature Reduction of Cooling Asphalt Pavements Using High-Reflectivity Paints (고반사 도료를 사용한 차열성 아스팔트 도로포장의 온도저감특성)

  • Hong, Chang Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.1
    • /
    • pp.317-327
    • /
    • 2013
  • Air pollution and artificial heat of urban areas have caused the urban heat island in which asphalt pavements absorb solar heat during the daytime and release the heat at night. Hence, in order to improve the environment of urban areas, it is necessary to examine cooling pavements that can reduce heat on road pavements in urban areas. The application of temperature insulation paints on road pavements require to reduce black brightness for visibility, to increase the reflection rate of infrared light and minimize the reflection rate of visible light. In the study, one part of Acrylic-emulsion was used as a main binder, and the changes in black brightness and the changes of addition ratio (0%, 15%, 30%) of hollow ceramics, as well as kinds of paints (carbon black pigment, mixed mineral pigment) were selected as the main experimental factors. The performance of temperature reduction of cooling pavements was analyzed through the reflection rate of spectrum, the reflection rate of solar heat, and the lamp test. Abrasion resistance, UV accelerated weather resistance, and sliding resistance were tested in real situations. In addition, the performance of heat reduction of testing pavements covered with high-reflection paints was analyzed by using an infrared camera. As the test results, when using mixed mineral paints and hollow ceramic of 30%, the reflection rate of spectrum was 43% in the area of near-infrared ray and 17% in the area of visible light at black brightness of $L^*$=42.89 and the reflection rate of solar heat was 27.5%. Total color difference was ${\Delta}E$=0.27 in the test of UV Accelerated Weather Resistance, indicating almost no changes in color. BPN was more than 53 when scattering #2 and #4 silica sand of more than $0.12kg/m^2$. In Taber's abrasion resistance test, abrasion loss was up to 86.4mg at 500 rotations. The performance of heat reduction was evaluated using an infrared camera at the test section applying high-reflection paints to asphalt pavements, in which the results showed that the temperature was reduced by $12.7^{\circ}C$ on CI-30-40 cooling pavements ($L^*$=38.76) and by $14.2^{\circ}C$ on CI-30-60 cooling pavements ($L^*$=57.12).

A Study on the Prevalence and Risk Factors of Liver Dysfunction among the Workers in Chemical Factories (화학공장 근로자들의 간기능 이상 유병률 및 위험인자에 관한 연구)

  • Cheong, Hae-Kwan;Kim, Joung-Soon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.1 s.56
    • /
    • pp.103-128
    • /
    • 1997
  • The object of this study is to evaluate the possibility of chemical-induced liver disorder among workers exposed to various chemicals and to classify the the liver function abnormalities by causes and to analyse the risk factors for each liver disorders. A cross-sectional study including questionnaire survey, physical examination, laboratory tests and ultrasonography of liver was conducted on 1,126 workers, 459 workers in a coal chemical plant(company A) and 667 workers in an insulation material manufacturing factory(company B). An industrial hygienist reviewed the chemicals used in both companies and evaluated the work environments to classify the workers by chemical exposure semiquantitatively. The results are as follows: 1. Of 459 workers in company A, 83 workers(18.1%) are classified as nonexposed, group 163(35,5%) as short-term exposure group, 155(33.8%) as intermediately exposed group and 58(12.6%) as long-term exposed group bared on the mean daily exposure to hepatotoxic chemicals evaluated by an industrial hygienist. Of 667 workers in company B, 484(72.6%) workers were classified as nonexposed and 183(35.5%) as exposed group. 2. Workers with SGOT level higher than 40 IU/l were (10.0%) in company A and 77(11.5%) in company 3, and those with SGPT level higher than 35 IU/l were 118(25.7%) in company A and 198(29.7%) in company B. The differences were not significant between companies and between exposure groups(p>0.05). Workers with $\gamma-GT$ level higher than 62 IU/l were 29(6.3%) in company A and 77(11.5%) in company B (p<0.01). The difference between exposure groups was not significant(p>0.05) within companies. Workers with liver function abnormalities(defined as SGOT higher than 40 IU/l or SGPT higher than 35 IU/l) were 338(30.0%) among 1,126 workers. Of 338 workers with live. function abnormalities 139(12.3%) had fatty liver by ultrasonography, 79(7.0%) had alcoholic liver(defined as workers with liver function abnormalities with weekly alcohol consumption greater than 280 g for more than 5 years), 54(4.8%) had hepatitis B, 12(1.1%) had hepatitis C and the other 114(33.7%) was not otherwise classified. Prevalences of alcoholic liver and fatty liver were significantly lower in company A(prevalence ratio 0.24 for alcoholic liver, p<0.001, prevalence ratio 0.76 for fatty liver, p<0.05) but prevalences of liver disorders between exposure groups within companies were not significant(p>0.05). 3. Summary prevalence ratios(SPR) of live. function abnormalities, fatty live. and other liver disorders, adjusted by age and company were not significantly higher in exposed group in any chemicals(p>0.05) but in some chemicals, SPRs were significantly lower. 4. On simple analysis of risk factors for liver function abnormalities, prevalence odds ratio(POR) of those with age between 30 and 39 was 1.54(p<0.01) and those with age ever 40 was 1.51(p<0.01). POR of those with histories of liver disorders and general anesthesia was 1.77(p<0.001) and 4.02 for those with overweight and 6.23 for those with obesity, defined by body mass index(p<0.001). 5. On logistic regression analysis, risk factors of liver function abnormality were fatty liver(POR 2.92 for grade 1, 12.15 for grade 2), presence of hepatitis B surface antigen(POR 3.62) and obesity(POR 5.38 for overweight and 16.52 for obesity). Presence of hepatitis B surface antigen(POR 0.18) was the only preventive facto. of fatty live. Company(POR 0.30) and obesity(POR 2.49 for overweight, 4.52 for obesity) were related to the alcoholic live. Obesity(POR 2.94 for overweight) was the only significant risk factor of hepatitis B and there was no significant risk factor for liver function abnormality not otherwise classified. It is concluded that the evidence of liver disorder related with chemical exposure is not evident in these factories. It is also postulated that fatty liver and alcoholic liver is most common causes of liver function abnormalities among workers and effort for weight control and improvement of life style should be done.

  • PDF

Properties of Hot Weather Nuclear Power Plant Concrete with Water Cooling Method and Retarding used (배합수 냉각방법 및 지연제 사용에 따른 서중 원전콘크리트의 특성)

  • Lee, Seung-Han;Jung, Yong-Wook;Jang, Seok-Soo;Yeo, In-Dong;Choi, Jong-Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4602-4609
    • /
    • 2013
  • In summer and winter, the difference between the temperature during the day and that during the night is high, which leads to various problems during concrete placement, such as cracks and defects in the concrete as well as low durability and strength. Although nuclear power plant concrete is widely used for placement in all seasons, particular attention must be paid to its quality during the summer. Therefore, we evaluated the effects of a cooling method for mixing water, which is a commonly used hot weather precooling method, and the use of a retarder, on the characteristics of Nuclear Power Plant concrete. In the cooling method for mixing water, cold water at 5 was used, with 50% of the water content consisting of ice flakes. The effects of using a retarder were evaluated by reviewing the characteristics of the cement at the unset stage and after hardening. To evaluate the characteristics of the unset cement, we measured the slump, air volumes, setting times, and pressure strengths after hardening. Furthermore, we measured the heat of hydration at different temperatures; the loss of heat was minimized using insulation. Both the slump time and the complete ageing time of the air volume were found to be 120 min at $20^{\circ}C$ and 40 min at $40^{\circ}C$. In the case when the cooling method for mixing water was used and in the case when a retarder was used, the initial and final sets by penetration resistance were delayed, and the delay decreased with increasing air temperature. For the heat of hydration, the cooling method for mixing water not only lowered the maximum temperature but also delayed its attainment. However, the use of a retarder had no effect on the maximum temperature. Moreover, in the early ages (e.g., 3 and 7 days), the pressure strength of the concrete was lower than that of plain cement. However, the strength of 28-day concrete met the standard construction specifications.