• 제목/요약/키워드: nickel removal

검색결과 110건 처리시간 0.024초

특정제조업 폐수처리시설에 대한 신뢰성 평가 (Reliability Assessment of Industrial Wastewater Treatment Plant)

  • 양형재;김재훈;이성종
    • 환경위생공학
    • /
    • 제22권4호
    • /
    • pp.1-9
    • /
    • 2007
  • A wastewater treatment plant, operating process is physico-chemical/biological activated sludge attached sand filtration, was selected to evaluate effluent quality and pollutants removal efficiencies consideration for deriving the technology-based effluent limitation for petroleum refining industry discharge. The results of influent and effluent analysis were as follows: Average effluent quality were 0.076mg/l of copper, 0.084mg/l of lead, 0.036mg/l of zinc, 0.005mg/l of nickel and 0.004mg/l of cadmium, and the range of coefficient of reliability from 0.007 of copper to 1.0 of lead. Also, 95% of reliability, 0.112, 0.15, 0.063, 0.015 and 0.009mg/l, respectively, were remarkably lower than their effluent limitations. And to reach 95% reliability of effluent limitation at cleanness area, designed effluent quality of copper, lead, zinc and cadmium should be 0.268, 0.099, 0.526 and 0.008mg/l, respectively.

티타늄과 니켈-크롬 합금의 도재결합강도 비교 (COMPARISON OF THE BOND STRENGTH OF CERAMICS FUSED TO TITANIUM AND Ni-Cr ALLOY)

  • 박세영;전영찬;정창모
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.89-98
    • /
    • 2003
  • Titanium requires special ceramic system for veneering. Low fusing dental ceramics with coefficients of thermal expansion matching that of titanium have been developed. The purpose of this study was determine the bond strengths between cast and noncast pure titanium and two commercial titanium porcelains, and to compare the results with a conventional nickel-chromium alloy-ceramic system. The bond strengths were determined using a 3-point flexure test. Three-point flexure specimens $25{\times}3{\times}0.5mm$ were prepared After removal of ${\alpha}-case$ layer, they were veneered with $8{\times}3{\times}1mm$ of ceramics at the center of the bar. Specimens were tested in a universal testing machine. Within the limits of this study, the following conclusions were drawn: 1. The bond strengths between pure titanium and two commercial porcelains exceeded th lower limit of the bonding strength value in ISO 9693(25MPa). 2. There was no significant difference between cast and noncast titanium-porcelain bonds. 3. There was no significant difference between two commercial titanium porcelains. 4. The bond strengths of the titanium-porcelain systems ranged from 73% to 79% of that of the Ni-Cr-conventional porcelain system.

BNi-2계 삽입금속에 의한 SUS304 스테인리스강 접합체의 강도와 조직에 미치는 브레이징 온도의 영향 : Ni기 삽입금속에 의한 브레이징 접합성의 기초적 검토(II) (Influence of Brazing Temperature on Strength and Structure of SUS304 Stainless Steel Brazed System with BNi-2 Filler Metal : Fundamental Study on Brazeability with Ni-Based Filler Metal(II))

  • 이용원;김종훈
    • 한국재료학회지
    • /
    • 제17권3호
    • /
    • pp.179-183
    • /
    • 2007
  • A plate heat exchanger (PHE) normally uses vacuum brazing technology for connecting plates and fins. However, the reliability of high temperature brazing, especially with nickel-based filler metals containing boron the formation of brittle intermetallic compounds (IMCs) in brazed joints is of major concern. since they considerably degrade the mechanical properties. This research was examined the vacuum brazing of commercially SUS304 stainless steel with BNi-2 (Ni-Cr-B-Si) filler metal, and discussed to determine the influence of brazing temperatures on the microstructure and mechanical strength of brazed joints. In the metallographic analysis it is observed that considerable large area of Cr-B intermetallic compound phases at the brazing layer and the brazing tensile strength is related to removal of this brittle phase greatly. The mechanical properties of brazing layer could be stabilized through increasing the brazing temperature over $100^{\circ}C$ more than melting temperature of filler metals, and diffusing enough the brittle intermetallic compound formed in the brazing layer to the base metal.

DEVELOPMENT OF A STEAM GENERATOR LANCING SYSTEM

  • Jeong Woo-Tae;Kim Seok-Tae;Hong Sung-Yull
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.391-398
    • /
    • 2006
  • It is recommended to clean steam generators of nuclear power plants during plant outages. Under normal operations, sludge is created and constantly accumulates in the steam generators. The constituents of this sludge are different depending on each power plant characteristics. The sludge of the Kori Unit 1 steam generator, far example, was found to be composed of 93% ferrous oxide, 3% carbon and 1% of silica oxide and nickel oxide each. The research to develop a lancing system that would remove sludge deposits from the tubesheet of a steam generator was started in 1998 by the Korea Electric Power Research Institute (KEPRI) of the Korea Electric Power Corporation (KEPCO). The first commercial domestic lancing system in Korea, the $KALANS^(R)-I$ Lancing System, was completed in 2000 for Kori Unit 1 for cleaning the tubesheet of its Westinghouse Delta-60 steam generator. Thereafter, the success of the development and site implementation of the $KALANS^(R)-I$ lancing system for YGN Units 1&2 and Ulchin Units 3&4 was also realized in 2004 for sludge removal at those sites. The upper bundle cleaning system for Westinghouse model F steam generators is now under development.

Decontamination of radioactive wastewater by two-staged chemical precipitation

  • Osmanlioglu, Ahmet E.
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.886-889
    • /
    • 2018
  • This article presented two-staged chemical precipitation for radioactive wastewater decontamination by using chemical agents. The total amount of radioactive wastewater was $35m^3$, and main radionuclides were Cs-137, Cs-134, and Co-60. Initial radioactivity concentration of the liquid waste was 2264, 17, and 9 Bq/L for Cs-137, Cs-134 and Co-60, respectively. Potassium ferrocyanide, nickel nitrate, and ferrum nitrate were selected as chemical agents at high pH levels 8-10 according to the laboratory jar tests. After the process, radioactivity was precipitated as sludge at the bottom of the tank and decontaminated clean liquid was evaluated depending on discharge limits. By this precipitation method decontamination factors were determined as 66.5, 8.6, and 9 for Cs-137, Cs-134, and Co-60, respectively. By using the potassium ferrocyanide, about 98% of the Cs-137 was removed at pH 9. At the bottom of the tank, radioactive sludge amount from both stages was totally $0.98m^3$. It was transferred by sludge pumps to cementation unit for solidification. By chemical processing, 97.2% of volume reduction was achieved. The potassium ferrocyanide in two-staged precipitation method could be used successfully in large-scale applications for removal of Cs-137, Cs-134, and Co-60.

첩포시험을 이용한 치과용 재료의 알러지 평가 (Evaluation of Hypersensitivity Reaction to Dental Materials with a Patch Test)

  • 전희선;박준상;고명연
    • Journal of Oral Medicine and Pain
    • /
    • 제25권2호
    • /
    • pp.167-172
    • /
    • 2000
  • Both immune reaction and hypersensitivity reaction are occurred by the same mechanism, the antigen and antibody reaction. The favorable result of this reaction towards a host is called clinically an immune reaction and the opposite results is called an hypersensitivity reaction. Type IV hypersensitivity reaction is a delayed type which is related to the cellular immune reaction and a contact hypersensitivity is included in this type. Various dental materials such as metal (mercury, nickel, chrome, cobalt), resin and eugenol are etiologic substances. Patch test kit is composed of test substance with a controlled concentration which respond only to a susceptible patient and an aluminum chamber, and etiologic substances for hypersensitivity can be easily and comfortably found just by applying the kit to the patient's skin. In this case report, the patch test was performed to a patients with oral lichen planus and the allergen, restorative material was found. After removal of the matching restoration from the patient's mouth, the symptom was improved.

  • PDF

동전기 정화기술을 이용한 Zn, Ni, F 복합오염 토양의 정화 (Electrokinetic Remediation of Soil Contaminated with Zn, Ni and F)

  • 조정민;류병곤;박성우;김경조;백기태
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제14권1호
    • /
    • pp.36-43
    • /
    • 2009
  • Zn, Ni 및 불소로 복합 오염된 토양의 정화를 위해서 동전기 정화(Electrokinetic remediation)기술을 적용하였다. 토양에서 탈착된 불소는 음이온 형태이고, Zn, Ni은 양이온으로 존재하기 때문에 간극수가 이동하는 전기삼투(electro-osmosis)와 이온이 이동하는 전기이동(electro-migration)의 두 가지 기작에 의해 제거되는 경향이 달랐다. 불소는 알칼리 조건에서 토양으로부터의 탈착이 증가하고, Zn과 Ni은 산성조건에서 탈착이 증가된다. 두 가지 탈착 특성이 다른 오염물질을 순차적 pH조절을 통해 효과적으로 제어할 수 있었다. 정전압 하에서의 영향을 평가하기 위하여 2V/cm를 적용하여으며, 2주간의 실험을 통해 Zn은 20.5%, Ni은 2.5%, 불소는 57.4% 제거되었다. Zn과 Ni의 제거율은 낮았으나 토양 ph조절을 통해 이동 가능함을 확인하였다. 토양 pH조절을 통하여 특성이 다른 복합오염물질을 동전기 정화 기술로 제거할 수 있을 것으로 사료된다.

우라늄 전착물의 염증류에 대한 우라늄 공정(共晶) 형성 및 열해석 연구 (Study of the Formation of Eutectic Melt of Uranium and Thermal Analysis for the Salt Distillation of Uranium Deposits)

  • 박성빈;조동욱;황성찬;강영호;박기민;전완기;김정국;이한수
    • 방사성폐기물학회지
    • /
    • 제8권1호
    • /
    • pp.41-48
    • /
    • 2010
  • 전해정련공정을 통해 생산된 우라늄 전착물은 약 30%의 용융염을 포함하고 있으므로, 순수한 우라늄을 회수하여 금속 잉곳으로 용이하게 제조하기 위해서는 용융염을 먼저 제거하는 공정이 필요하다. 우라늄 전착물의 염증류 거동을 고찰하기 위해서는 염증류의 주요 공정변수인 유지온도와 진공압의 염제거율에 대한 영향를 고찰해야 한다. 이전 연구에서 우라늄전착물에 대한 염증류 거동에 대해 Hertz-Langmuir 관계식을 적용하여 각 용융염의 휘발 조건에 대해 염휘발계수를 얻을 수 있었으며 이로부터 우라늄 전착물에 대해 99% 이상의 염제거율을 나타내는 염증류공정의 조업조건을 도출하였다[1]. 한편, 염증류 장치에서 사용되는 재질인 스테인리스강에 대해 우라늄 전착물에서 염휘발된 우라늄 금속이 스테인리스강의 주성분인 철, 니켈, 크롬 등과 공정(eutectic melt)을 형성하지 않는 온도에서 염증류공정을 수행해야 하는 제한 조건이 따른다. 이번 연구에서는 우라늄 금속과 스테인리스강과의 반응성을 검토함으로써 우라늄 전착물의 염을 99% 이상 제거할 수 있는 조건을 확인하였다. 그리고 염증류 속도를 증진시키며 휘발된 염을 더 효율적으로 회수하기 위해 공급되는 알곤 흐름에 의한 염증류 장치의 열해석을 수행함으로써 알곤 흐름에 의한 우라늄 전착물에 대한 염증류 거동을 고찰하였다.

페로니켈 슬래그로 부터 제조된 Mg(OH)2를 이용한 CO2 고정화 (CO2 Fixation by Magnesium Hydroxide from Ferro-Nickel Slag)

  • 송호양;서종범;강성규;김인득;최봉욱;오광중
    • 청정기술
    • /
    • 제20권1호
    • /
    • pp.42-50
    • /
    • 2014
  • 본 논문은 페로니켈 슬래그를 이용하여 간접적으로 $CO_2$를 고정화시키는 기술에 대한 연구를 하였으며, 효율적으로 Mg를 추출하여 제조된 $Mg(OH)_2$$CO_2$ 고정화 최적 조건을 제시하고자 하였다. 실험 결과, 최적의 추출조건은 1 M $H_2SO_4$, 반응온도 333 K이었으며, 용출액에 NaOH를 첨가하여 pH값을 8까지 높일 경우, 침전물은 $Fe_2O_3$로 확인되었다. 또한 pH 값이 11까지 높아질 때, 그 성분은 $Mg(OH)_2$로 나타났다. 이렇게 제조된 $Mg(OH)_2$ slurry 용액을 $CO_2$ 고정화실험에서 준 2차 탄산화반응 모델을 통해 적용한 결과, 반응온도 및 초기 $CO_2$분압에 따라 초기 $CO_2$의 고정화 속도를 증진할 수 있는 반면 반응온도가 323 K 이상 높아질 경우, 고정화속도가 감소하는 것으로 나타났다. 또한 $CO_2$ 고정화반응 시 이온을 조사한 결과, $CO_2$를 고정화 할 수 있는 최적의 pH 조건으로 8.38 이상 유지해야 할 것으로 판단되었다. 종합적으로 본 연구에서는 페로니켈 슬래그를 이용하여 $CO_2$를 고정화하기 위한 최적의 조건을 도출하였으며, 향후 $CO_2$를 고정화 하기 위한 연구의 기초자료로 활용할 수 있을 것으로 판단된다.

아연백법 및 공침공정을 이용한 복합 중금속-시안착염 폐수의 현장처리(I) (The Treatment of Heavy Metal-cyanide Complexes Wastewater by $Zn^{+2}/Fe^{+2}$ Ion and Coprecipitation in Practical Plant(I))

  • 이종철;강익중
    • 대한환경공학회지
    • /
    • 제29권12호
    • /
    • pp.1381-1389
    • /
    • 2007
  • 중금속 폐수는 다양한 유독성 화합물과 함께 배출되므로 상수원, 토양, 지하수 등의 환경에 악영향을 야기 시킬 수 있다. 이러한 고농도의 복합중금속과 시안착염을 포함한 도금폐수 처리 시 일반적으로 잘 알려진 알카리염소법에 의한($1^{st}$ Oxidation: pH 10, reaction time 30 min, ORP 350 mV, $2^{nd}$ Oxidation: ORP 650 mV) 시안의 잔류농도에 대한 제거효율은 유입수의 시안농도 374 mg/L에 비해 처리 후 잔류시안농도는 3.74 mg/L로써 그 제거효율이 99%로써 상당히 높았으나 수질환경보전법상 수질배출허용기준(나 지역) 1 mg/L 이하에 만족하기 위해서는 2차, 3차 등의 고도처리가 요구됨을 알 수 있었고, 이에 아연백법 및 공침처리공정(reaction time: 30 min, pH: 8.0, rpm: 240)을 적용하여 용해되어 잔류하는 시안착염을 불용성염으로 침전시켜 처리한 결과 잔류시안농도가 1.0 mg/L 이하의 만족할 만한 결과를 있었다. 크롬의 처리는 6가 크롬을 3가 크롬으로 환원(pH: 2.0 max, ORP: 250 mV)시킨 후, 수산화물로 처리(pH: 9.5)시 무난히 99%의 최대 제거효율을 얻을 수 있었다. 폐수 중 나머지 동(Cu)과 니켈(Ni)처리는 황화물 응집침전법을 적용한 결과 최적 pH는 $9.0\sim10.0$에서 $Na_2S$의 최적주입량이 Cu의 경우 0.5 mol에서 99.1%, Ni의 경우 3.0 mol에서 99.0% 이상 제거할 수 있었다. 즉 중금속 복합폐수 중 시안착염은 알카리 염소산화처리법만으로는 수질환경보전법의 규제치 이하로 처리가 불가능 하였고 아연백법 및 공침공정을 같이 적용한 결과 규제치 이하로 처리가 가능하다는 것을 현장 확인할 수 있었다.