• Title/Summary/Keyword: newly built apartment

Search Result 51, Processing Time 0.022 seconds

Reduction of Indoor VOCs' Concentrations using Flush-out in a Newly Built Apartment (신축공동주택에서 플러쉬아웃 실시에 따른 실내 VOCs 농도저감 효과에 관한 연구)

  • Park, Sang-In;Park, Jun-Seok
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.12
    • /
    • pp.57-63
    • /
    • 2018
  • The purpose of this study was to confirm the effects of flush-out on the reduction of Volatile Organic Compounds(VOCs) concentration in newly built residential buildings. The field measurements were conducted in two complexes of multi-residential buildings which are located suburban areas of Seoul. About three samples of residential buildings were selected in the field measurements. Two samples, B and C, had been flush-out with outdoor air more than seven days. The sample A was maintained at same condition during the flush-out because of the comparison. The indoor concentrations of VOCs in the three samples were measured at three times, before, during, and after flush-out. From the field measurements, it was confirmed that two samples' indoor VOCs' concentrations were considerably decreased after the flush-out comapred with those of the sample A in which the flush-out was not conducted. The decreases of indoor VOCs concentrations were corresponding to about 50% ~ 92% of the concentrations of before. Through the reviews for the previous studies, it was also found that the reduction effects of the flush-out is similar with the those of the bake-out which were reported in the previous studies.

Analysis on Characteristics and Related Factors of Indoor Air Quality in Newly Built Wooden Houses (신축목조주택의 실내공기질 특성 및 관련요인 분석)

  • Choi, Yoon-Jung;Lee, Jae-Kyung;Cha, Ye-Rang
    • Journal of the Korean housing association
    • /
    • v.26 no.4
    • /
    • pp.23-32
    • /
    • 2015
  • The purpose of this research is to analyze characteristics and related factors of IAQ (Indoor Air Quality) in newly built wooden houses by measuring pre and post occupancy. The subjects were five wooden houses which were built with similar materials and completed from July to December 2013. Measuring factors were TVOC, HCHO, PM10, $CO_2$, CO, indoor temperature, and relative humidity. As the result of pre occupancy measuring, the houses that revealed the lowest TVOC concentration or HCHO concentration were satisfied with "the standard for newly built apartment houses". Therefore, IAQ by the wooden structures is considered to be in good condition. However, in cases of partial value exceeded the standard, the reason is analyzed to be the materials of molding, wrapping doors, built-in closet, or kitchen furniture, etc. rather than structure materials. Most PM10 concentration level showed slightly below "the standard for occupied multi-use facilities". Remaining of construction dust was considered to be the reason. As the result of post occupancy measuring, every value except of one subject's TVOC concentration was lower than pre occupancy, explaining the importance of natural ventilation.

Effects of Flush-out in the Reduction of Formaldehyde in Newly Built Residential Buildings (신축 공동주택에서 플러쉬아웃에 따른 폼알데하이드 농도 저감 효과에 관한 연구)

  • Park, Sang In;Kim, Joo Han;Park, J.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.116-122
    • /
    • 2018
  • The purpose of this study was to confirm the effects of flush-out in the reduction of formaldehyde concentration in newly built residential buildings. The field measurements were conducted on two complexes of multi-residential buildings which are located in the suburban area of Seoul. About eight samples of residential buildings were selected to measure the changes in formaldehyde concentrations after flush-out from the two apartment complexes. The concentration of formaldehyde was measured using DNPH cartridge and HPLC. From the results of the field measurements, it was established that indoor formaldehyde concentration decreases 27.6~54.2% in the samples after flush-out. The number of days that the flush-out were conducted was noted to have no significant influence on the reduction rate of formaldehyde concentration when the flush-out continued more than 7 days. The comparison with Bake-out showed that flush-out also can reduce formaldehyde in newly built buildings as same levels of it.

Community-acquired Legionnaires' Disease in a Newly Constructed Apartment Building

  • Ryu, Sukhyun;Yang, Kyungho;Chun, Byung Chul
    • Journal of Preventive Medicine and Public Health
    • /
    • v.50 no.4
    • /
    • pp.274-277
    • /
    • 2017
  • Objectives: Legionnaires' disease (LD) is a severe type of pneumonia caused by inhalation of aerosols contaminated with Legionella. On September 22, 2016, a single case of LD was reported from a newly built apartment building in Gyeonggi province. This article describes an epidemiologic investigation of LD and identification of the possible source of infection. Methods: To identify the source of LD, we interviewed the patient's husband using a questionnaire based on the Legionella management guidelines from the Korea Centers for Disease Control and Prevention. Water samples from the site were collected and analyzed. An epidemiological investigation of the residents and visitors in the apartment building was conducted for 14 days before the index patient's symptoms first appeared to 14 days after the implementation of environmental control measures. Results: Legionella pneumophila serogroup 1 was isolated from the heated-water samples from the patient's residence and the basement of the apartment complex. Thirty-two suspected cases were reported from the apartment building during the surveillance period, yet all were confirmed negative based on urinary antigen tests. Conclusions: The likely source of infection was the building's potable water, particularly heated water. Further study of effective monitoring systems in heated potable water should be considered.

The Study on the Indoor Air Quality in a Newly Built Apartment Rouse by Field Measuring (실측을 통한 신축공동주택의 실내공기질에 관한 연구)

  • Lee Kyung-Hee;Bae Jong-Soo;Cho Sung-Woo;Park Min-Yong;Park Chang-Sub;Choi Jeong-Min
    • Journal of the Korean housing association
    • /
    • v.17 no.4
    • /
    • pp.111-117
    • /
    • 2006
  • The harmfulness of HCHO and VOCs from construction material and furniture has been increased gradually. It must be need to prevent pollution materials' accumulation indoor effectively and to remove very small amount of harmful pollution materials in various plans, because these kinds of pollution materials greatly affect human body, Therefore, this study is focused to find out the improvements of Indoor Air Quality in execution of natural ventilation and bakeout to reduce indoor chemical pollution materials or not. After effects of indoor air quality by natural ventilation and bake-out being examined, it is follows the conclusion. As for the density change of TVOC and Toluene according to time lapse, in case the middle and high-story areas have bake-out, the density increased once, but it showed the gradual decrease after bake-out was stopped, and it was shown that it exceeded the standards recommended for newly built apartment. The bake-out is effective to discharge the HCHO and TVOC from the construction material and the furniture, and the natural ventilation is effective remove the indoor pollution materials.

The Characteristic of the Concentration Transition of Chemical Substances in Energy Saving House and Apartment House (에너지절약 주택과 일반 아파트에서의 실내 화학오염물질 농도 변화 특성)

  • Yoo, Bok-Hee;Park, Sun-Hyo
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • Recently, much attention has been paid to the problem such as sick building syndrome, which caused by the indoor air pollutant. Volatile Organic Compounds $(VOC_s)$ and formaldehyde have been considered as one of the main reason that causes indoor air pollutant. This study is for introducing and designing thermal performance of super energy saving building by conducting $VOC_s$ and formaldehyde concentration in the 3Liter house. The results of the measurement for 10 months showed that $VOC_s$ and formaldehyde decreased until the guideline concentration. It took about 7 months, and it appeared right after new construction. However, their levels were showed higher concentration in comparison with the ordinary residential houses (apartment house). The main difference of between newly built 3Liter house and ordinary apartment is their air changes, which are 0.67/h for 3Liter house and 4.0/h for the apartment.

A Study on Sale revitalization Video Phone Market - The Case of Seoul City - (영상전화기(비디오폰) 판매 활성화방안 연구 - 서울시를 중심으로 -)

  • Kim, Dae-youn;Lee, Sang-youn
    • Journal of Distribution Science
    • /
    • v.7 no.1
    • /
    • pp.35-53
    • /
    • 2009
  • Sees the market where home appliance and network equipment, the communication service enterprises are new recently the home network market of the most which has an interest in the home network is being activated the newly-built high-class apartment in the center. The company building leads because not being option of the case last customer of newly-built market and must do a business . marketing. So newly-built market the demand grasp which is individual leads sale activation with difficult and that to creates a benefit there is a limit judges and axis market in the object hereafter demand at even the popular house the function to prepare in being magnified is simple and there is a possibility of saying that a more effort is demanded in supply style video phone market opening up where the price is cheap. Saw with like this reason from, analyzes the concept and a market trend of the video phone, grasps distribution channel forms and A/S handling systems and there is the goal finds the video phone sale revitalization plan which is suitable in all market.

  • PDF

Actual Use Pattern of Environment-friendly Finish Materials in Recently-Constructed and Remodeled Apartment Houses (공동주택 유형별 친환경 마감재 사용 실태분석 연구)

  • Lee, Ji-Soon
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.39-45
    • /
    • 2011
  • The concepts of interior design work have set forward an aesthetic and functional proposition to be answered by those who design spaces. The available range of suitable materials for interior use appears to be almost inexhaustible in this day and age. Now a day, relatively new fields of study on environmental-friendly interior examine humans'innate affinity for health and explore its implications for architecture and the built environment. A growing field of research suggests that spaces' relationship to aesthetics and environment can either help or hinder their occupants' health and wellness, productivity, and even their creativity. This paper presents several examples of already built apartment houses in practice, and discusses the demand of users of the spaces for health and sustainable environment, deepening the relationship between newly-constructed spaces and the remodeled ones. The considerations to some new and contemporary materials from the aspect of healthy indoor architecture design are presented in this paper. Designers need to rethink the conventional and high-tech interior environment in apartment houses with respect to perceived air quality, material emissions, and odors. The future of interior design is oriented on light shapeable materials which are able to create a unique memorable atmosphere. The primary assignment in accepting recent materials and proceedings is our responsibility to creating proposals, that are mainly safe, hygienic and environmentally proper.

The Concentration Variation of Volatile Organic Compounds before and after Renovation in Apartment Houses (아파트 개조 전후의 휘발성유기화합물 농도변화 실태)

  • Choi, Yoon-Jung;Shim, Hyun-Suk;Shin, Hae-Chul
    • Journal of the Korean housing association
    • /
    • v.18 no.4
    • /
    • pp.59-67
    • /
    • 2007
  • The purposes of this study were to make clear the present condition of the TVOC and HCHO concentration after renovation in apartment houses. The field measurements of TVOC and HCHO concentration according to the Korea Test Method Standard for Indoor Air Quality were carried out in 4 subject apartment houses. The results are as follows; the TVOC concentration after renovation in apartment houses ranged from mean 0.35ppm to mean 5.08ppm and increased of $0.35{\sim}5.08ppm$. The TVOC concentration of 3 subjects exceeded the Indoor Air Quality Management standard for the newly-built apartment houses (0.58ppm). The HCHO concentration after renovation ranged from mean 0.13ppm to mean 0.43ppm and increased of $0.06{\sim}0.26ppm$. The HCHO concentration of 2 subjects exceeded the Standard (0.17ppm). As results of analysis on the relation of concentrated ascension and renovation elements, the amount and the types of finishing materials and adhesives affected concentrated ascension. Also, production method for installed or purchased furniture had certain effect on the TVOC and HCHO concentration ascension.