Radioactive Neutron Source Calibration at the Korea Standards Research Institute (K-SRI 에서의 방사성 중성자 선원교정)

  • Hwang, Sun-Tae;Choi, Kil-Oung
    • Journal of Radiation Protection and Research
    • /
    • v.10 no.1
    • /
    • pp.67-73
    • /
    • 1985
  • The manganous sulfate bath method for neutron source calibrations at the K-SRI is described together with the measurement of neutron emission rate of a source and the corrections applied for capture by competing nuclei of neutrons, and thermal neutron leakage, neutron absorption in the source itself. The commercially available neutron sources (Am-Be, $^{252}Cf$) for the calibration checks of neutron radiation instruments in the MeV range are considered in this paper.

  • PDF

Residual stress measurements using neutron diffraction (중성자법에 의한 잔류응력 측정법)

  • Woo, Wanchuck;Kim, Dong-Kyu;An, Gyu-Baek
    • Journal of Welding and Joining
    • /
    • v.33 no.1
    • /
    • pp.30-34
    • /
    • 2015
  • Residual stresses are inherently introduced into the engineering components during manufacturing including rolling, forging, bending and welding processes. Excessive residual stresses are known to be detrimental to the proper integrity and performance of components. Neutron diffraction has become a well-established technique for the determination of residual stresses in welds. The deep penetration capability of neutrons into most metallic materials makes neutron diffraction a powerful tool for the residual stress measurements through the thickness of the weld specimen. Furthermore, the unique volume-averaged bulk characteristic of the scattering beam and mapping capability in three dimensions is suitable for the engineering purpose. In this presentation, the neutron diffraction measurements of the residual stresses will be introduced and measurement results will highlighted in thick weld plates.

A Study on Neutron Resonance Energy of Tantalum by 46-MeV Electron Linac TOF Method (46-MeV 전자선형가속기의 TOF 방법을 이용한 탄탈의 중성자 공명 에너지 분석에 관한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.245-249
    • /
    • 2013
  • Neutron sources from photonuclear reaction with 46-MeV electron linear accelerator at Research Reactor Institute, Kyoto University used for resonance energy measurement of natural tantalum. BGO($Bi_4Ge_3O_{12}$) scintillation detectors used for measurement of the prompt gamma ray from the natural tantalum sample. The BGO spectrometer was composed geometrically as total energy absorption detector. The electric signal from the spectrometer was analyzed for TOF(Time-of-Flight) spectrum which is used identification of neutron capture resonance energy. In this study, the neutron energy region is from 1 to 200 eV, because of strong X-ray effect produced photonuclear reaction in Ta target, the measurement was performed to below 1 keV energy region. The resonance energy was compared with the evaluated values(ENDF/B-VI, Mughabghab). All of the resonances from 4.28 ~ 200 eV were seen in the present measurement except 144.3 eV resonance.

Measurement of the Energy-Dependent Neutron Capture Cross Section of $^{99}Tc$ by Using the Neutron TOF Method (-중성자 TOF법에 의한 $^{99}Tc$의 에너지의존 중성자 포획단면적측정-)

  • Yoon Jung-Ran;Lee Sang-Bock;Lee Jun-Haeng;Lee Sam-Yol
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.5
    • /
    • pp.133-139
    • /
    • 2005
  • The neutron capture cross section of $^{99}Tc$ has been measured relative to the $^{10}B(n,\gamma)$ standard cross section by the neutron time-of-flight(TOF) method in the energy range of 0.007 eV to 47 keV using a 46-MeV electron linear accelerator(linac) at the Research Reactor. Institute, Kyoto University(KURRI). In order to experimentally prove the result obtained, the supplementary cross section measurement has been made from 0.3 eV to 1 keV using the Kyoto University Lead stowing-down spectrometer (KULS) coupling to the linac. The relative measurement by the TOF method has been normalized to the reference value(20.01 b) at 0.0253 eV and the KULS measurement to that by the TOF method. The existing experimental data and the evaluated capture cross sections in ENDF/B-VI, JENDL-3.2, and JEF-2.2 have been compared with the current measurements by the linac TOF and the KULS experiments.

  • PDF

Estimation of Neutron Energy Spectrum of Cf-252 using Single Bonner Sphere with TLD-600 and TLD-700 (단일 보너구와 TLD-600 및 TLD-700을 이용한 Cf-252의 중성자 에너지 스펙트럼 평가)

  • Kim, Sunghwan;Cheon, Jongkyu;Lee, Jae Jin;Nam, Uk-Won
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.223-226
    • /
    • 2013
  • We designed a single polyethylene bonner sphere with several thermo-luminescence dosimeters (TLD), for measurement of neutron energy spectrum. For the separation of the neutron dosage in the neutron-gamma mixed field, we used 21 ea TLD-600s and TLD-700s, respectively. Because, TLD-600 is sensitive to neutron and gamma rays, and, TLD-700 is sensitive only to gamma-rays, we could determine the each dose by neutron and gamma rays. The neutron response function of the bonner sphere with TLDs was calculated by MCNPX (ver. 2.5.0) Monte Carlo simulation in the energy range from $10^{-1}$ to 20 MeV. For the Cf-252 standard neutron source in KRISS, we could estimate the neutron energy spectrum by unfolding method using the response function.

Measurement of the Shape in the Radioactive Area by Ultrasonic Wave Sensor

  • Park, Koon-Nam;Sim, Chuel-Muu;Park, Chang-Oong;Lee, Chang-Hee;Park, Jong-Hark
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.7
    • /
    • pp.927-934
    • /
    • 2002
  • The HANARO ( High-flux Advanced Neutron Application Reactor) has been operated since 1995. The Cold Neutron (CN) hole was implanted in the reflector tank from the design stage. Before a vacuum chamber and a moderator cell for the cold neutron source are installed into the CN hole, it is necessary to measure exactly the size of the inside diameter and thickness of the CN hole to prevent the interference problem. Due to inaccessibility and high radiation field in the CN hole, a mechanical measurement method is not permitted. The immersed ultrasonic technique is considered as the best way to measure the thickness and the diameter of the CN hole. The 4-Axis manipulator was designed and fabricated for locating the ultrasonic sensors. The transducer of an ultrasonic sensor having 10 MHz frequency leads to high resolution as much as 0.03mm. The inside diameter and thickness of 550 points of the CN hole were measured using 2 channel ultrasonic sensors. The results show that the thickness and inside diameter of the CN hole is in the range of 3.3∼6.7mm and 156∼ 165mm, respectively. This data will be a good reference for the design of the cold neutron source facility.

An adaptive deviation-resistant neutron spectrum unfolding method based on transfer learning

  • Cao, Chenglong;Gan, Quan;Song, Jing;Yang, Qi;Hu, Liqin;Wang, Fang;Zhou, Tao
    • Nuclear Engineering and Technology
    • /
    • v.52 no.11
    • /
    • pp.2452-2459
    • /
    • 2020
  • Neutron spectrum is essential to the safe operation of reactors. Traditional online neutron spectrum measurement methods still have room to improve accuracy for the application cases of wide energy range. From the application of artificial neural network (ANN) algorithm in spectrum unfolding, its accuracy is difficult to be improved for lacking of enough effective training data. In this paper, an adaptive deviation-resistant neutron spectrum unfolding method based on transfer learning was developed. The model of ANN was trained with thousands of neutron spectra generated with Monte Carlo transport calculation to construct a coarse-grained unfolded spectrum. In order to improve the accuracy of the unfolded spectrum, results of the previous ANN model combined with some specific eigenvalues of the current system were put into the dataset for training the deeper ANN model, and fine-grained unfolded spectrum could be achieved through the deeper ANN model. The method could realize accurate spectrum unfolding while maintaining universality, combined with detectors covering wide energy range, it could improve the accuracy of spectrum measurement methods for wide energy range. This method was verified with a fast neutron reactor BN-600. The mean square error (MSE), average relative deviation (ARD) and spectrum quality (Qs) were selected to evaluate the final results and they all demonstrated that the developed method was much more precise than traditional spectrum unfolding methods.

Energy Calibration for Neutron Capture Resonance of Natural Sm by Using 46-MeV Electron Linear Accelerator

  • Lee, Jae-Hong;Lee, Sam-Yol
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.2
    • /
    • pp.31-35
    • /
    • 2007
  • Energy calibration is important to identify accurate neutron capture resonance energy in the neutron TOF (Time-of-Flight) experiment. In present study, the accurate neutron capture resonance energies of natural Sm were measured by using a 46-MeV electron linear accelerator (linac) at the Research Reactor Institute, Kyoto University(KURRI). The BGO spectrometer were adopted for measurement the prompt capture gamma-ray of the sample. To obtain energy calibration curve, resonance energy of a gold sample used as standard resonance energy Mughabghab's data (From neutron resonance parameters data). Previous data (by Mughabghab) of natural Sm sample have been compared with the present result.

  • PDF

Fabrication and Characteristics of Thin-film Neutron Thermopile for Reactor Instrumentation (원자로계측을 위한 박막중성자열전대의 시작 및 특성)

  • 김동훈
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.9 no.5
    • /
    • pp.1-5
    • /
    • 1972
  • In order to improve the response time of nelltron theromopile for reactor control a neutron thermopile made use of a vacuunl evaporated thin film thor mocouple was fablicated and tested. The test results were compared with a wire-type neutron thermopile. Good linearities between the response of the neutron thermopile and the thermal flux has been shown in the ranges from n/$\textrm{cm}^2$/sec. Thermal neutron flux distributions in the core of TRIGA Mark-II reactor were measured using the fabricated neutron thermopile, and the results were conpared with data obtained by the acrivatin foil measurement.

  • PDF

Neutron Count Rate Measurement of $UO_2$ powder by Neutron Source

  • Kang Hee-Young;Koo Gil-Mo;Ha Jang-Ho;Kim Ho-Dong;Yang Myung-Seung
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.344-349
    • /
    • 2005
  • Neutron count rate measurements to assay fissile content of uranium powder have been carried out in a neutron counter. The induced fission neutrons by Cf-252 neutron source are counted as the variation of fissile material in fuel material. The measured counts are compared with equivalent results obtained from calculation. It shows that the measured neutron counts versus quantity of $UO_2$ powder enrichment agreed reasonably well with the calculated values.

  • PDF