• Title/Summary/Keyword: neutral line

Search Result 327, Processing Time 0.026 seconds

3-Phase 4-Wire Series Active Power Filter System for Harmonics and Unbalanced Loads (고조파와 부하불평형에 대한 3상4선식 직렬형 능동전력필터 시스템)

  • Ko Soo-Hyun;Han Yoon-Seok;Kim Young-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.603-606
    • /
    • 2002
  • This paper introduces a control algorithm for 3-phase 4-wire series active power filter This control algorithm compensates harmonics and neutral line currents which are generated by balanced or unbalanced nonlinear loads. The advantage of this control algorithm is direct extraction of compensation voltage references. Therefor calculation time is shorten and the performance of series active power filter is improved. Compensation principle of the proposed control algorithm is presented in detail. Experimental results are shown to verify the effectiveness of tile proposed control algorithm.

  • PDF

Development of Die Design System for Turbine Blade Forging (터빈 블레이드의 형단조 금형설계의 자동화에 관한 연구)

  • 최병욱;조종래;왕지석;김동권;김동영
    • Transactions of Materials Processing
    • /
    • v.8 no.6
    • /
    • pp.569-575
    • /
    • 1999
  • Computer programs have been developed to design the forging dies of turbine and compressor blades. The design of forging dies is based the side force and the filling of die cavity. In this study, slab method has been applied to simulate forging processes numerically. the program composed of Visual Basic also provides the informations of mean stress, total forging load, distribution of temperature, position of neutral line, total volume and volume of flash in the final stage to users. The preform position is predicted by the reverse slab method. The program has been successfully applied to various types of turbine blades.

  • PDF

The Relationship between Wind Power Generation Grid-connected Transformer Winding Connection and Fault Current in MATLAB & SIMULINK (MATLAB & SIMULINK에서 풍력발전 계통연계 변압기결선과 고장전류와의 관계)

  • An, Hae-Joon;Kim, Hyun-Goo;Jang, Gil-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.307-309
    • /
    • 2008
  • This study suggests a modeling of grid-connected wind turbine generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, generator rotor speed, generator terminal current and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

3-Phase 4-Wire Series Active Power Filter System for Harmonics and Unbalanced Loads Compensation (고조파 전류와 불평형부하 보상을 위한 직렬형 능동전력필터)

  • Park, Seung-Ho;Jeong, Rak-Kyo;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.931-932
    • /
    • 2006
  • This paper proposes a control algorithm for 3-phase 4-wire series active power filter. This control algorithm compensates harmonics and neutral line currents which are generated by balanced or unbalanced nonlinear loads. The advantage of this control algorithm is direct extraction of compensation voltage references. Therefore, calculation time is shorten and the performance of series active power filter is improved. Compensation principle of the proposed control algorithm is presented in detail. Experimental results are shown to verify the effectiveness of the proposed control algorithm.

  • PDF

A Design and Analysis of a Neutral Line Harmonics Eliminating Reactor (중성선 영상고조파저감용 특수 Reactor 설계와 해석)

  • Kim, Chul;Kim, Han-Deul;Kim, Han-Soo;Shin, Pan-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.52-54
    • /
    • 2004
  • 현대정보화산업에서 배전계통의 부하는 첨단 제어장치, 다양한 반도체 전력변환 설비, OA기기 및 PC 둥의 사용으로 배전계통의 중성선에 영상 고조파가 많이 발생한다. 이것을 최소화하기 위해서 본 연구에서는 중성선의 영상전류를 제거하는 장치인 특수 리액터를 설계하고 유한요소프로그램(Flux2D)을 이용하여 특성을 해석하여 검증하였다. 최적설계를 위하여 누설자속의 최소화, 코아 및 동손의 최소화를 위한 설계알고리즘도 구성하여 최적설계안을 제안하였다.

  • PDF

Construction of Lightning Protection System for Railway Signaling Equipments (철도신호설비용 낙뢰방호장치의 건설)

  • Choi Kyu-Hyoung;Seo Seok-Chul;Choi Se-Wan
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1193-1198
    • /
    • 2004
  • This paper describes the lightning protection system for railway signaling equipments installed at subway car depots in Seoul metropolitan Rapid Transit Cooperation. Several measures for improving lightning protection performance are adopted; newly organized grounding system for neutral line of power system, rolling method to minimize damages induced by direct lightning strike, new measures to reduce voltage differences between the signaling equipments and the ground, and improvement of grounding system. The proposed system has greatly reduced the grounding resistance and also the voltage difference between the signaling equipments and the ground, and has prevented the accident related with lightning surges since it was installed. The proposed approach can be viewed as a useful alternative of dealing with lightning protection for railway signaling equipments.

  • PDF

A modelling on Shunt Reactors in Railway Power Transmission System (철도고배 전송선로 분로리액터 설치에 대한 모델링)

  • Lee, Jongsoo;Lee, Jongwoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1262-1268
    • /
    • 2015
  • I In power transmission systems, voltage changes continuously as reactive power is whether over supply or shortage. Reactive power produces in generators and consumes in transmission lines, and loads. Voltages at end points of transmission lines rise which is called Ferranti effect. Excessive voltage rising can reduce transmission equipment life, the voltage rising is usually permitted within the limit of 10%~30% excess. Shunt reactors are installed in transmission lines to put a curb on voltage rising. In this paper, we tried to do modelling for shunt reactor configuration types which are no grounding, grounded and grouded neutral reactor. Simulation are carried out for reactor magnitude for compensating transmission line capacitance.

Evaluation of Iron Nickel Oxide Nanopowder as Corrosion Inhibitor: Effect of Metallic Cations on Carbon Steel in Aqueous NaCl

  • Chaudhry, A.U.;Mittal, Vikas;Mishra, Brajendra
    • Corrosion Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • The aim of this study was to evaluate the use of iron-nickel oxide ($Fe_2O_3$.NiO) nanopowder (FeNi) as an anti-corrosion pigment for a different application. The corrosion protection ability and the mechanism involved was determined using aqueous solution of FeNi prepared in a corrosive solution containing 3.5 wt.% NaCl. Anti-corrosion abilities of aqueous solution were determined using electrochemical impedance spectroscopy (EIS) on line pipe steel (API 5L X-80). The protection mechanism involved the adsorption of metallic cations on the steel surface forming a protective film. Analysis of EIS spectra revealed that corrosion inhibition occurred at low concentration, whereas higher concentration of aqueous solution produced induction behavior.

DESIGN OF A BENDING MAGNET FOR THE KSTAR NBI SYSTEM

  • In, Sang-Ryul;Yoon, Byeong-Joo;Kim, Beom-Yeol
    • Nuclear Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.793-802
    • /
    • 2006
  • The design concept of a bending magnet to be installed in the KSTAR NBI system is presented. It is the function of a bending magnet that removes unconverted ions from the main beam stream and produces an 8 MW, 120 keV deuterium neutral beam. In order to determine the proper size and shape of the bending magnet, a parametric study on the B-field pattern was carried out by changing the dimensions of the pole face model. In addition, the detailed trajectories of the dominant ion species produced in the beam line were calculated. The electrical and cooling parameters of the coil assembly were also estimated.

A New Control Algorithm for 3-Phase 4-Wire Series Active Power Filter System (3상 4선식 직렬형 능동전력필터의 새로운 제어법)

  • 김영조;고수현;김영석
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.12
    • /
    • pp.714-722
    • /
    • 2002
  • This paper presents a control algorithm for a 3-phase 4-wire series active Power filter. This control algorithm compensates harmonics, input power factor and neutral line currents which are generated by balanced or unbalanced nonlinear loads. The advantage of this control algorithm is direct extraction of compensation voltage references. Therefore, the calculation time is shortened and the performance of the series active power filter is improved. The compensation principle of the proposed control algorithm is presented in detail. A 3KVA laboratory prototype of the three-phase four-wire series active power filter was built and experiments have been carried out. Experimental results are shown to verify the effectiveness of the proposed control algorithm.