• 제목/요약/키워드: neutral line

검색결과 327건 처리시간 0.035초

가브리엘 샤넬과 요지 야마모토의 무채색 복식에 나타난 디자인 특성과 패션 이미지 연구 (A Study on the Fashion Design Characteristics & Fashion Image of Gabrielle Chanel & Yohji Yamamoto)

  • 고순영;박문희
    • 복식문화연구
    • /
    • 제18권5호
    • /
    • pp.789-808
    • /
    • 2010
  • The orientalism in fashion is believed to develop from the eclectic notion of oriental and occidental fashion. By studying on Gabrielle Chanel's clothing that is usually used by neutral colors and on Yohji Yamamoto's clothing that characterizes clothes in neutral colors, the purpose of this study is to seek ways for remaking Korean traditional clothing into a new modern one to gain a world reputation in terms of clothes. Therefore the study is for exploring the characteristics on the factors of fashion design such as color, line and textile materials with works of Gabrielle Chanel, a famous designer in Western world who has made a black color a popular one for people and works of Yohji Yamamoto, an well-known fashion designer of the East using neutral colors. This study analyzed, from the 2004 S/S to the 2006 F/W, the collection of works published in style.com through the works of Gabrielle Chanel, Yohji Yamamoto, and through the analysis of the visual target. A total of 527 images are used in this paper. Elements of fashion design analysis are lines, colors, and materials. The study reached the conclusion as follows after analyzing the characteristics on clothing with neutral colors of Gabrielle Chanel and Yohji Yamamoto. In case of aesthetic characteristics on the design of Gabrielle Channel, it has expression of feminist, sensual, modern and luxury. It is considered that Gabrielle Channel has a luxury image using a neutral color. Also using simple sleeveless in black and tweed structure, the garments have mixed with neutral colors. Fashion design characteristics on the design of Yohji Yamamoto classified into sensual, modern, ascetic expression. Therefore the design has a simple expression of using a black color. Yohji Yamamoto is a designer who pursues unstructured design by using various neutral colors such as black, gray and white based on the oriental sentiment.

송전선로 주변 통신선의 유도장해 원인 분석 (The Inductive Interference of Communication Line Near by Transmission Line)

  • 강연욱;곽주식;권동진;심응보;배주호;김재준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.400-402
    • /
    • 2003
  • The inductive interference can be happened on some of the communication line that is located near by paralleled transmission line. The causes of inductive interference are magnetic coupling, capacitive coupling and residual voltage at neutral point of transmission line. In this paper, after grounding the one side of communication line, we have measured the voltage to ground at the other side of it. And we also have measured the voltage to ground at the end of it without grounding. As a result, we proved that the cause of inductive interference is the difference of ground voltages.

  • PDF

혼합배전계통에서 뇌과전압 해석을 통한 중성선과 가공지선 혼용 운전시 적정 피뢰기 위치에 관한 연구 (A Study on the Optimal Position of Lightning Arrester on Joint Operation of Neutral Wire and Overhead Grounding Wire through Lightning Surge Analysis in Combined Distribution System)

  • 정석산;장화윤;안천용;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.535-536
    • /
    • 2011
  • This paper studies the validity about a joint operation of neutral wire and overhead grounding wire in combined distribution systems. The overhead grounding wire and neutral wire are currently installed separately and grounded by common. However there is no any ineffectiveness or electrical problem in case of the proposed system, such system can be operated at real distribution system. Therefore this paper describes the suitability of a joint operation through lightning surge analysis on combined distribution systems and analyzes the optimal position of lightning arrester on joint operation of neutral wire and overhead grounding wire. Lightning surge analysis is carried out by EMTP/ATPDraw to obtain the overvoltage of overhead line and underground cable in various conditions such as location and current types of lightning stroke. Over voltage gained by the analysis show that the insulation strength of the joint operation case is not stable compare with the current operation case.

  • PDF

Lyα Radiative Transfer and The Wouthuysen-Field effect

  • 선광일;김창구
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.43.1-43.1
    • /
    • 2017
  • A three-dimensional (3D) $Ly{\alpha}$ radiative transfer code is developed to study the Wouthuysen-Field effect, which couples the 21 cm spin temperature of neutral hydrogen and the $Ly{\alpha}$ radiation field, and the escape fraction of $Ly{\alpha}$ from galaxies. The Monte Carlo code is capable of treating arbitrary 3D distributions of $Ly{\alpha}$ source, neutral hydrogen and dust densities, gas temperature, and velocity field. It is demonstrated that the resonance-line profile at the center approaches to the Boltzmann distribution with the gas temperature. A plane-parallel ISM model, which is appropriate for the neutral ISM of our Galaxy, is used to calculate the $Ly{\alpha}$ radiation field strength as a function of height above the galactic plane. We also use a two-phase, clumpy medium model which is composed of the cold and warm neutral media (WNM). It is found that the $Ly{\alpha}$ radiation field is strong enough to thermalize the 21 cm spin temperature in the WNM to the gas kinetic temperature. The escape fraction of $Ly{\alpha}$ is found to be a few percent, which is consistent with the $Ly{\alpha}$ observations of our Galaxy and external galaxies.

  • PDF

중성선을 갖는 변압기형 초전도 한류기의 용량증대 개선 연구 (Analysis on the Improvement of Power Capacity Increase in the Transformer-Type SFCL with Neutral Lines)

  • 조용선;최효상;김덕구;고성필
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1438-1443
    • /
    • 2011
  • The increase of power capacity in the superconducting fault current limiter (SFCL) is essential for application into the power grid. To achieve this, when superconducting units were connected in series and parallel, the unbalanced quenching characteristics between superconducting units generated by different critical current behavior should be improved. In the transformer-type SFCL, the superconducting units connected in series could be simultaneously quenched by the connection of neutral lines between secondary coils and superconducting units. From this the consumed power in superconducting units was equally distributed. In addition, the more the turn ratio of the transformer was reduced, the more consumed power in the superconducting units was reduced by the decrease of the induction voltage generated in the superconducting units. From those results, the transformer-type SFCL using neutral lines could increase the power capacity of the SFCL by the equal power division into the superconducting units.

Analysis of Off-Line and On-Line Partial Discharge in High Voltage Motor Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Lee, Sang-Kil;Kim, Beom-Soo;Kim, Doo-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1086-1092
    • /
    • 2015
  • The off-line and on-line partial discharge (PD) in the stator winding of three high-voltage (HV) motors (1,400 HP, 6.6 kV) is measured and analyzed in this paper. The off-line PD is measured at high values between 24,300 ~ 36,100 pC after 18 years of motor operation. Spare replacement motors were not available for testing the degree of deterioration of the stator windings in standstill status. Therefore, on-line periodic analysis was conducted to monitor the trend of PD after installing a ceramic sensor (110 pF, 6.6 kV) in the terminal box for each phase of each motor. In the stator winding of the No.1 and No.2 HV motors, which showed high magnitudes of off-line PD and low magnitudes of on-line PD, defects are expected to appear in the neutral end of the winding. On the contrary, in the stator windings of the No.3 HV motor, which exhibits high off-line and on-line PD magnitude, defects are expected to appear in the terminal end of the winding where a voltage close to the phase voltage is applied.

탄소중립 건물의 기술적 정의와 사례 분석을 통한 탄소중립 달성 잠재성 분석 (Analysis of Potential to Achieve Carbon Neutrality through Technical Definition and Case Study of Carbon-Neutral Buildings)

  • 정민희
    • 토지주택연구
    • /
    • 제15권2호
    • /
    • pp.19-28
    • /
    • 2024
  • 본 연구는 탄소중립건물의 기술적 정의 및 사례 분석을 통해 탄소중립 달성의 잠재성을 분석한다. 2015년 12월 파리 협정에 따라 세계는 평균 기온 상승을 2℃ 이하로 제한하고, 산업화 이전 수준보다 1.5℃로 제한하려는 노력을 추진하기로 합의하였다. 이를 위해 2050년까지 넷제로(net-zero) 상태에 도달해야 하며, 에너지, 토지, 수송 등 광범위한 부문에서 전환이 필요하다. 본 연구는 탄소중립을 달성하기 위한 기술적 접근과 실제 사례를 통해 탄소중립건물의 가능성과 한계를 탐구하며, 이를 통해 미래의 탄소중립 목표 설정에 기여하고자 한다. 특히, 탄소중립 건물의 정의와 그 실현을 위한 다양한 기술적 방안을 소개하고, 이를 실현한 국내외 사례를 분석함으로써 탄소중립 건물의 효과와 실행 가능성을 평가한다. 연구 결과는 탄소중립 건물의 설계, 건설 및 운영에 대한 구체적 가이드라인을 위한 정보를 제공하며, 정책 입안자와 실무자들이 지속 가능한 건축 환경을 조성하는 데 필요한 실질적 정보를 제공한다.

Analysis on How to Locate the Maximum Line Voltage to Hull in Steady State on the Vector Diagram Onboard Vessels

  • Choi, Soon-Man
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권7호
    • /
    • pp.966-973
    • /
    • 2011
  • Power distribution onboard vessel is typically configured as ungrounded system due to the ability to continuously supply electric power even when an earth fault occurs. The impedance connections between 3 phase power lines and hull cause the line-to-hull voltages to become unstable and increased in case the impedances are unbalanced, bringing the situation susceptible to electric shock and deterioration of insulation material. Also the line-to-hull voltage can reach to a certain maximum value in the steady state depending on the distributed capacitances and grounding resistances between lines and hull. This study suggests how to find and calculate the maximum line-to-hull voltage in view of magnitude and phase angle based on the vector diagram.

가변탭 변압기를 사용한 급전용량 증가 검토 (Examination of Increasing Power Delivery Capacity with variable Tab Autotransformer)

  • 이장무;한문섭;이한민;김주락;김길동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1163_1164
    • /
    • 2009
  • AC AT feeding method consists return circuits of electric train inserting in parallel between trolly line and feeding line and connecting neutral line to rail and FPW. Due to increasing train number, electric load at feeding system are increasing and collecting voltage of train are going down. To increase electric load and collecting voltage between trolly line and rail, the usefulness of new autotransformer are considered which variation of short impedance and change of line voltage is simulated with modified winding ratio of autotransformer from 1:1 to variable tab.

  • PDF

전원 및 신호시스템에서의 뇌서지 전파양상 (Propagation Tendency of Lightning Surge in the Power and Communication System)

  • 이태형;조성철;엄주홍
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.245-249
    • /
    • 2007
  • The tendency of lightning surge to propagate displays the difference for applicable power and equipment. However, looking into the subject equipment with the lightning surge, the lightning surge can be divided in between the two lines of power, between the power line and the ground, the power line and the PE conductor, between the neutral line and the ground and the like. In addition, in the event of the communication equipment, there exists the case of lightning surge entered from the power line in addition to the entry between the communication lines, the communication line and the ground. In this study, the tendency of propagation of lightning surge penetrated on to the subject equipment is analyzed through the empirical experiment in accordance with the ground method by using the independent ground, common ground, bypass arrester and others among the techniques for safety improvement in power lines.

  • PDF