• Title/Summary/Keyword: negative(positive) relative convergence

Search Result 33, Processing Time 0.022 seconds

Changes in Visual Function After Viewing an Anaglyph 3D Image (Anaglyph 3D입체 영상 시청 후의 시기능 변화)

  • Lee, Wook-Jin;Kwak, Ho-Won;Son, Jeong-Sik;Kim, In-Su;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.179-186
    • /
    • 2011
  • Purpose: This study aimed to compare and assess changes of visual functions in viewing an anaglyph 3D image. Methods: Visual functions were examined before and after viewing a 2D image and an anaglyph 3D image with red-green glasses on seventy college students (mean age = 22.29${\pm}$2.19 years). Visual function tests were carried out for von Graefe phoria test, accommodative amplitude test by (-) lens addition, negative relative accommodation (NRA) and positive relative accommodation (PRA) test, negative relative convergence (NRC) and positive relative convergence (PRC) test, accommodative facility, and vergence facility test. Results: Assessment of the visual functions indicated that near exophoria and accommodative amplitude were reduced after viewing a 3D image, and although there were small changes in relation to these findings, NRC and PRC showed tendencies to increase and decrease at near, respectively. There were no significant changes with NRA and PRA, and accommodative and vergence facility were shown to have improved. Conclusions: Changes of visual functions were more in the 3D image than the 2D image, especially at near than distance. Particularly, the improvement of accommodative and vergence facility could be related to an effect of subsequent accommodation and vergence shift to have stereopsis in the 3D image. These results indicate that an anaglyph 3D image may, to some extent, be the effect of vision training such as anaglyphs.

The Study of Accommodation Assessment in Binocular Functional Test (양안시검사의 조절평가 연구)

  • Cho, Young-Rae;Park, Hyun-Ju
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.1
    • /
    • pp.61-67
    • /
    • 2007
  • The binocular functional test was performed in test of both accommodation and convergence. The balance of accommodation and convergence was important. Objects were 100 adults in 18-36 years old ages. The used apparatus was vision tester(Shinnippon VT10)and visual chart(Shinnippon CT30). Accommodative lag test by fused cross cylinder were that in case of high 39.0%, in case of low 14.0%. Negative relative accommodation were that in case of high 23.0%, in case of low 38.0%. Positive relative accommodation were that in case of high 29.0%, in case of low 23.0%. In 18% were case of low accommodation.

  • PDF

Graphic Method of Visual Analysis and Norms Determination for the Far Distance Phoria (원거리사위별 그래프 분석과 표준값 결정)

  • Joo, Seok-Hee;Park, Seong-Jong;Sim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.193-200
    • /
    • 2006
  • We investigated the visual analysis of the far distance phoria for 83 subjects who have emmetropia or myopia eyes, using the graphic method, and determined new norms. We got the following results from these experiments. 1. The measured norm of far distance phoria is $1.12{\Delta}$, exophoria, the that of near distance phoria is $0.50{\Delta}$, exophoria, the that of negative relative convergence at far distance(N.R.C.) is ${\times}$/11/5, the that of positive relative convergence at far distance(P.R.C.) is 10/20/8, the that negative relative convergence at near distance(N.R.C.) is 11/21/5, the that of positive relative convergence at near(P.R.C.) is 10/20/8, the that of negative relative accommodation(N.R.A.) is +2.54D, and the that of positive relative accommodation(P.R.A.) is -2.60D, respectively. We know from theses results that the measured norms of far distancet phoria is higher than Morgan's norms, while those of near distance phoria are lower than Morgan's norms. 2. We also know from these experiments that Morgan's norms are closely related to A, B, and C groups and Morgan's criterion can more usefully apply to the visual analysis. 3. In Sheard's criterion and Percival's criterion, the prism prescription is occurred when the exophoria of the far-point phoria is over $7{\sim}9{\Delta}$, and the esophoria of that is over $4{\sim}6{\Delta}$.

  • PDF

Negative Ion Generation Index according to Altitude in the Autumn of Pine Forest in Gyeongju Namsan (경주 남산 소나무림의 가을철 해발고도별 음이온 발생지수)

  • Kim, Jeong Ho;Yoon, Ji Hun;Lee, Sang Hoon;Choi, Won Jun;Yoon, Yong Han
    • Korean Journal of Environment and Ecology
    • /
    • v.32 no.4
    • /
    • pp.413-424
    • /
    • 2018
  • The study analyzed the effects of topographic structures and altitude in mountainous parks in Mt. Namsan in Gyeongju on the generation of anions. The temperature was at ridge ($9.82^{\circ}C$) > valley ($8.44^{\circ}C$), the relative humidity valley (59.01 %) > ridge (58.64 %), the solar radiation ridge ($34.40W/m^2$) > valley($14.69W/m^2$), the wind speed ridge (0.63m/s) > valley(0.37m/s), and the negative ion valley($636.81ea/cm^3$) > ridge($580.04ea/cm^3$). In the valley, the correlation with altitude was verified for the temperature, relative humidity, solar radiation, and negative ion generation in the valley. The relative humidity, solar radiation, and negative ion indicated a positive correlation while the temperature had a negative correlation. In the ridge, the correlation with altitude was verified for the temperature, relative humidity, wind speed, solar radiation, and negative ion generation. The relative humidity, solar radiation, and negative ion generation indicated a positive correlation while the temperature and wind speed had a negative correlation. The regression analysis showed the prediction equation of y=-0.006x+9.663 (x=altitude, y=temperature) in the valley and y=-0.009x+11.595 (x=altitude, y=temperature) in the ridge for the temperature, y=0.027x+53.561 (x=altitude, y=relative humidity) in the valley and y=0.008x+56.646 (x=altitude, y=relative humidity) in the ridges for the relative humidity, and y=0.027x+53.561 (x=altitude, y=negative Ion generation) in the valley and y= 0.008x+56.646 (x=altitude, y=negative Ion generation) in the ridge for the negative ion generation.

Analysis of Binocular Abnormality by Eyeball Motion in Ametropia (비정시의 안구운동에 의한 양안시 이상 분석)

  • Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.3
    • /
    • pp.205-213
    • /
    • 2005
  • To evaluate the reliability of binocular vision measurements by phorometry. 90 students volunteered to participate in this study. 25 subjects were males, and 65 were females, they ranged in ages from 21 to 30 years. All subjects had normal ocular and systematic health, and all of them had at least 1.0 visual acuity with their best correction. At negative relative convergence(NRC) measurement in distance, the percentage of subjects is included in expected value(blur point/break point/recovery point) was 78%/61%/67%, divergence excess(DE) was 9%/31%/33%, and divergence insufficience(DI) was 13%/8%/9%, respectively. And positive relative convergence(PRC) measurement, includes expected value was 20%/46%/39%, convergence excess(CE) was 22%/14%/16%, and convergence insufficience(CI) was 35%/40%/45%. AC/A ratios of 42 subjects were normal. 38 were low, and the rest of them high. A low AC/A ratio is usually the result of a small vergence response in relation to accommodation. Negative relative convergence(NRC) at near, includes expected value was 26%/29%/44%, divergence excess(DE) was 61%/33%/24%, and divergence insufficience(DI) was 3%/38%/32%. And PRC at near, includes expected value was 33%/40%/31%, convergence excess(CE) was 61%/23%/42%, and convergence insufficience(CI) was 6%/37%/27%. For the near point of convergence(NPC) test, 58% of their subjects had a break of ${\leq}8cm$ with the accommodative target. In case of NRA(PRA) measurement, the expected value was 41%(33%). Accommodative insufficiency (AI) was 33%(43%), and accommodative excess(AE) was 26%(24%), respectively. AE was related to respectively low values of NRA. AI and CE are associated with high value of NRA, and the dysfunction of convergence excess combined with AE was related to a normal-high values of NRA. PRA in AI was related to a low value, wheres the dysfunction are associated with high values of PRA.

  • PDF

Characteristics of Ion Index by Type of Land Use in Small City - Focused on Chungju (중소도시 토지이용유형별 이온지수 특성 - 충주시를 대상으로 -)

  • Kim, Jeong-Ho;Lee, Sang-Hoon;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.27 no.7
    • /
    • pp.489-497
    • /
    • 2018
  • In this study, the ion index characteristics of small and medium urban land use types were investigated in the city of Chungju. The average temperature for each land use type was in the order: general commercial district ($29.59^{\circ}C$) > general residential district ($28.34^{\circ}C$) > productive green district ($28.31^{\circ}C$). The average relative humidity was in the order: productive green district (70.12%) > general residential district (69.93%) > general commercial district (66.48%). The average wind speed was in the order: productive green district (0.95 m/s) > general commercial district (0.87 m/s) > general residential district (0.54 m/s). Positive and negative ions were investigated to determine the ion index by land use type. The average amount of positive ion generated was in the order: general commercial district ($737ea/cm^3$) > general residential district ($492ea/cm^3$) > productive green district ($445ea/cm^3$). The average negative ion production decreased in the order: productive green district ($930ea/cm^3$) > general residential district ($754ea/cm^3$) > general commercial district ($744ea/cm^3$). The ion index calculated from measured data can be arranged in the order: productive green district (2.09) > general residential district (1.53) > general commercial district (1.01). These results confirm the state of positive and negative ion generation in each land use type. Further, the differences in the ion index by land use type were confirmed. However, a limitation of this study is that simple summer measurements were conducted, and seasonal characteristics were not considered. Therefore, any future investigation and research should consider seasonal variation characteristics.

Comparison of Binocular Function in Normal Subjects and Convergence Insufficiency (정상안과 폭주부족안의 양안시기능 검사값 비교)

  • Shim, Hyun-Seog;Shim, Moon-Sik;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.287-291
    • /
    • 2010
  • Purpose: The aim of this study was to compare binocular functions such as near point of convergence (NPC), AC/A ratios, heterophoria, accommodation, accommodation lag, positive relative accommodation (PRA), negative relative accommodation (NRA), positive relative convergence (PRC), negative relative convergence (NRC) in normal subjects and convergence insufficiency. Methods: 86 subject (male n=45, female n=41, mean $age{\pm}SD=23.27{\pm}2.85$ years) without amblyopia, strabismus, and ocular pathology were studied. Forty three patients each group were classified as normal subjects and convergence insufficiency group based on AC/A ratio and far and near phoria. Binocular function of the two groups was measured using phoropter. r. Results: The values between normal subjects and convergence insufficiency were 5.71 cm and 7.07 cm for NPC, 5.28 and 2.81 for Heterophria AC/A, 0.92 exo/3.36 exo and 2.17 exo/10.84 exo for far and near phoria, 15.49/23.30/13.30 and 13.50/20.02/9.09 for PRC, respectively. However, there were no significant differences between normal subjects and convergence insufficiency for accommodative amplitude, accommodative lag, PRA, NRA, BI vergence test, BO vergence test, NRC. Conclusions: Both groups were a significant difference for cover test, NPC, Heterophria AC/A, far and near phoria, break point of PRC, and recovery point of PRC.

The study of binocular function of college students (대학생들의 시기능에 대한 연구)

  • Cho, Young-Rae;Park, Hyun-Ju;Seo, Ji-Keun;Seong, Jeong-Sub;Kim, Jae-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.2
    • /
    • pp.103-110
    • /
    • 2005
  • Binocular vision had a short history in Korea. As there were many near works in these days, the needs about comparative study have been increased. There was related to both refractive error and binocular anomalies, but it is difficult to applying for binocular vision expected findings in itself due to the fact that Korean differ from foreigner. Objects were 100 adults in 18-36 years old ages, The test was Von Gaefe method and used aparatus was phoropter(Shinnippon VT10)and visual chart(Shinnippon CT30). According to interview results was that symptom in near works were headaches 28.0%, blinking 27.3%, red eye 25.1%, eyepain 15.6%, watering 15.3%, itch 12.2%, photophobia 8.5% and eye strain 7.4%. A people who have above ${\pm}0.50$ D refractive error in total objectives (100-male 45/female 55) were classified into ametropia. There was a results such as emmetropia (12.0%), ametropia(88.0%), exophoria(32.0%), esophoria(12.0%). Far negative relative convergence were that in case of high 43.0%, in case of low 7.0%. Far positive relative convergence were that in case of high 15.0%, in case of low 38.0%. Near phoria was exophoria(32.0%), esophoria(12.0%). Near negative relative convergence were that in case of high 23.0%, in case of low 38.0%. Far positive relative convergence were that in case of high 29.0%, in case of low 23.0%. Near negative relative accommodation were that in case of high 10.0%, in case of low 14,0%, Far positive relative convergence were that in case of high 69.0%, in case of low 12.0%. Results were different from expected findings, and especially positive relative accommodation was very high, However, We suggest that the expected findings in Korea for several subjects must study in binocular function.

  • PDF

Prevalence of binocular anomalies in adult Koreans (한국인의 양안 시기능 이상에 관한 고찰)

  • Ryu, Geun Chang;Park, Hyun Ju;Seong, Jeong Sub;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.147-154
    • /
    • 2000
  • To describe the prevalence of binocular anomalies in adult Koreans. Patients included were 19 to 40 years of age, 41 males and 60 females and living in Kwang-Ju Korea. Refractive correction was estimated objectively with an autorefractometer and subjectively refined without cycloplegia. Myopia was defined as a refractive error less than -0.50 diopters hyperopia was defined as a refractive error greater than +0.50 diopters. 101 no strabismic patients who had a refractive error and a near lateral phoria(46%) and an AC/A(accommodative convergence/accommodation) anomaly(50.4%). The prevalence of a near vergence anomaly(52.5%) was higher than a near divergence anomaly(55.5%). The prevalence of a positive relative accommodation(PRA) anomaly(61.4%) was higher than a negative relative accommodation(NRA) anomaly(54.5%). According to Morgan's analysis method, patients with vergence anomaly(21.7%) were seen slightly less frequently than those with accommodative interaction anomaly(29.7%). 34.6% of patients had both vergence anomaly and accommodative interaction anomaly. These results indicate that full prescription for a refractive corrections should be considered as these can improve binocular visual function for ametropia.

  • PDF

Variation According to Distance of Esophoria patients (거리에 따른 내사위 환자의 변화)

  • Hong, Soo-Hak;Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.2
    • /
    • pp.47-52
    • /
    • 2003
  • 117 undergraduate ophthalmic optics students volunteered to participate in this study. They ranged in age from 19 to 26 years. Subject, had best corrected visual acuity of at least 1.0 in both eyes, no strabismus, no amblyopia, and no history of ocular surgery. 37 subjects are esphoria and 25 subjects are $3{\Delta}$ and less, and the rest of 12 subjects show more $4{\Delta}$. Average phoria amount is $2.96{\Delta}$ at far distance and $1.08{\Delta}$ at near distance, respectively. The variation of phoria amount in far and near distance, unchanging subjects are 3, 8 subjects are increase esophoria amount, and 26 subjects are phoria amount decreasing or appear exophoria. The reason of esophoria amount is decreasing in near distance, and the results are convergence burden decreases. At positive relative convergence, the expected value in far distance, blurred point is 7, break point is 16, and recovery point is 12. And negative relative convergence, break point is 7 and recovery point is 13, respectively. Moreover, at positive relative convergence, the expected value in near distance is blurred point is 8, break point is 7 and recovery point is 22. And negative relative convergence, blurred point is 2, break point is 8 and recovery point is 12, respectively.

  • PDF