• Title/Summary/Keyword: needles

Search Result 681, Processing Time 0.026 seconds

The Effect of Carbide Precipitation on the High Temperature Deformation of Ni3Al and TiAl

  • Han, Chang-Suk;Kim, Jang-Woo;Kim, Young-Woo
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.3
    • /
    • pp.147-154
    • /
    • 2009
  • The effect of carbon addition on the microstructures and mechanical properties of $Ni_3Al$ and TiAl intermetallic alloys have been characterized. It is shown that carbon is not only an efficient solid solution strengthener in $Ni_3Al$ and TiAl, it is also an efficient precipitation strengthener by fine dispersion of carbide. Transmission electron microscope investigation has been performed on the particle-dislocation interactions in $Ni_3Al$ and TiAl intermetallics containing various types of fine precipitates. In an $L1_2$-ordered $Ni_3Al$ alloy with 4 mol.% of chromium and 0.2~3.0 mol.% of carbon, fine octahedral precipitates of $M_{23}C_6$ type carbide, which has the cube-cube orientation relationship with the matrix, appear during aging. Typical Orowan loops are formed in $Ni_3Al$ containing fine dispersions of $M_{23}C_6$ particles. In the L10-ordered TiAl containing 0.1~2.0 mol.% carbon, TEM observations revealed that needle-like precipitates, which lie only in one direction parallel to the [001] axis of the $L1_0$ matrix, appear in the matrix and preferentially at dislocations. Selected area electron diffraction (SAED) patterns analyses have shown that the needle-shaped precipitate is $Ti_3AlC$ of perovskite type. The orientation relationship between the $Ti_3AlC$ and the $L1_0$ matrix is found to be $(001)_{Ti3AlC}//(001)_{L10\;matrix}$ and $[010]_{Ti3AlC}//[010]_{L10\;matrix}$. By aging at higher temperatures or for longer period at 1073 K, plate-like precipitates of $Ti_2AlC$ with a hexagonal structure are formed on the {111} planes of the $L1_0$ matrix. The orientation relationship between the $(0001)_{Ti2AlC}//(111)_{L10\;matrix}$ is and $[1120]_{Ti2AlC}//[101]_{L10\;matrix}$. High temperature strength of TiAl increases appreciably by the precipitation of fine carbide. Dislocations bypass the carbide needles at further higher temperatures.

Antioxidant effect of complex extracts from pine needle, green tea, and sea buckthorn leaves (솔잎, 녹차 및 비타민나무 잎 혼합추출물의 항산화효과)

  • Ji, Hee Young;Park, Min Gyu;Joo, Shin Youn
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.3
    • /
    • pp.290-295
    • /
    • 2021
  • This study investigated the antioxidant effects of complex extracts from pine needles (PN), green tea (GT), and sea buckthorn leaves (SL). Measurement of total polyphenol and flavonoid content, DPPH radical scavenging activity (DPPH), ABTS+ radical scavenging activity (ABTS), and reducing power (RP), showed that SL extract (SE) had the highest values. The superoxide radical scavenging activity (SSA) and nitrite scavenging activity (NSA) were the highest in the GT extract (GE). In most experiments, the PN extract (PE) showed higher activity in complex extracts than in single extracts. The combination of GT and SL led to a higher activity than that exhibited by GT (DPPH and ABTS at 300 ppm, RP at 100 and 500 ppm) and SL (SSA at 100 ppm and NSA at 300 ppm) alone. These results suggest that the combination of PE, GE, and SE may be a useful functional food material in the food industry.

Variations in Monoterpene Emissions from Pinus densiflora in Simwon Village at Jiri Mountain (지리산 심원마을 소나무의 Monoterpene 방산 농도 변화)

  • Park, Mi-Jin;Choi, Won-Sil;Cho, Minseok;Kim, Juwan;Kim, Jaehyeon;Lee, Young-Kyu
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.1
    • /
    • pp.13-21
    • /
    • 2021
  • In this research, monoterpene emissions were investigated from pine trees(Pinus densiflora) and in the forest air in Simwon village at the Jiri Mountain. Air samples from an enclosed chamber and pine forest air were collected using a Tenax TA Tube five times a day(at 09:00, 11:00, 13:00, 15:00, and 17:00) on 1 day per month from March to November 2014. Selected needles and branches from individual pine trees were enclosed for the measurement of their monoterpene emissions. The concentration and composition of emitted monoterpenes were analyzed in a time series. The major components of monoterpenes emitted from pine trees were α-pinene, β-myrcene, β-phellandrene, and β-pinene. Seasonal data showed that the concentration of monoterpenes emitted from pine trees began increasing in June and reached its peak in August, decreasing thereafter. In addition, seasonal emissions of monoterpenes were dependent on environmental factors such as temperature. The major species of monoterpenes in forest air were α-pinene, β-pinene, and camphene. The concentration of monoterpenes in forest air began rising from March to April and reached its peak in May; multiple peaks subsequently formed in July and November. Diurnal variation in monoterpenes decreased from 09:00-10:00, reaching a low and high at 13:00-14:00 and 17:00-18:00, respectively.

Critical Review and Alternatives to the Decriminalization of Tattooing (문신시술의 비범죄화에 대한 비판적 검토와 대안)

  • Shim, YoungJoo;Lee, Sang-Han
    • The Korean Society of Law and Medicine
    • /
    • v.23 no.1
    • /
    • pp.149-176
    • /
    • 2022
  • South Korean law strictly prohibits engagement in medical activities by non-medical practitioners. In the country, tattooing is classified as a medical practice, and non-medical practitioners who engage in it are penalized because they are unauthorized to carry out this procedure. In reality, however, people rarely seek tattooing services from medical personnel. Arguing that their freedom of job selection is violated, non-medical personnel who make a living as tattoo artists reject the characterization of the procedure as a form of medical treatment and demand the decriminalization of tattooing by non-medical practitioners. Nevertheless, tattooing can cause health- and hygiene-related dangers when it is not performed by medical professionals because it involves penetration into the skin using needles. Hence, stringent management is necessary for infection prevention. The gap between reality and the law gives rise to the need for proactive thinking about the institutionalization of tattoo practice by non-medical personnel. Policymakers should reflect on the fact that only minimal tattooing services are currently performed by medical staff while also accounting for health and safety. On this basis, this study examined tattoo-related legislation in South Korea to determine whether the procedure corresponds to medical practice and identify ways to solve problems that occur from the perspective of health care. As a response that promotes safety and reflects reality, this research proposed a three-phase approach.

Antimicrobial Properties of Cement Matrix using Pine Needle Extract (솔잎추출물을 혼입한 시멘트 경화체의 항균류 저항 특성)

  • Kim, Ho-Jin;Jung, Hyeon-Eui;Lim, Dong-Hyun;Han, Song-Yi;Park, Sun-Gyu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.117-123
    • /
    • 2022
  • Recently, due to COV ID-19, many people are spending most of their time indoors. So, there is a rising interest on the indoor air quality in the field of building construction. The main sources for the indoor air pollution are human indoors activity, building materials, living supplies and the polluted air from outdoor. The Korean government has designated 17 indoor air pollutants including fine dust, total airborne bacteria, fungi and carbon dioxide, etc.. Most people are always exposed to assorted bacteria and molds in our daily life, because indoor environment for human, moderate temperature are humidity, it is favourable to the growth of most of bacteria and fungi. Pine needles have an antibacterial effect against bacteria and fungi. In this study, the antibacterial activity against bacteria and fungi was tested by cement matrix using pine needle extract. As a result, the cement matrix using pine needle extract showed antibacterial activities against bacteria, but in the case of fungi, it did not show antifungal activity.

Effectiveness of Acupotomy for Migraine: A Systematic Review (편두통의 침도 치료에 대한 체계적 문헌고찰)

  • Seok-Hee Jeon;Soo-Min Jeong;Jeong-Cheol Shin
    • Korean Journal of Acupuncture
    • /
    • v.40 no.3
    • /
    • pp.62-78
    • /
    • 2023
  • Objectives : This study aims to assess the impact of acupotomy on migraine through an examination of clinical studies conducted since 2015. Methods : We conducted a comprehensive search for randomized controlled trials (RCTs) and non-randomized controlled trials (nRCTs) related to acupotomy treatment for migraine, utilizing five Korean online databases (OASIS, Science ON, DBPIA, KISS, RISS), as well as four foreign online databases (CNKI, PubMed, EMBASE, Cochrane Library). We identified a total of 10 relevant studies for analysis. Participants characteristics, treatment points, combination treatments, treatment cycles or frequencies, evaluation indices, efficacy, and adverse events were analyzed. The risk of bias in the 10 RCTs was assessed using the Revised Cochrane risk-of-bias tool for randomized trials (RoB 2.0). Results : A total of 931 participants were included in 10 studies. In the intervention group, the average duration of migraine morbidity ranged from 15.5±4.5 months to 15.9±4.2 years. Six studies based their diagnoses on the International Classification of Headache Disorders (ICHD), while five studies relied on Chinese diagnostic criteria. All studies specified the treatment area as the region exhibiting tenderness or induration on the head and neck. Treatment cycles ranged from a minimum of 2 days to a maximum of 1 week, with the number of days per treatment course varied from 5 days to 4 weeks. The diameter of acupuncture needles used varied between 0.3 mm and 1 mm. Of the eight studies specifying needle length, the shortest was 20 mm, and the longest was 40 mm. A total of eight evaluation indices were employed, with total efficacy rate (TER) and visual analogue scale (VAS) being the most frequently used. Statistically, all intervention groups showed more significant results compared to the control groups. Adverse events were reported in only two studies within the intervention group. Overall, the risk of bias assessment for the selected RCTs ranged from 'some concerns' to 'high risk of bias.' Conclusions : This study showed that acupotomy treatments for migraine were effective.

The Characteristics of Temperature Variation in Electronic Warm Acupuncture Device (전기식 온침기의 온도 변화 특성에 관한 연구)

  • Ja-Ha Lee;Jeong-Hyun Moon;U-Ryeong Chung;Soo-Hwa Hong;Gyoungeun Park;Byung Wook Lee;Won-Suk Sung;Jong-Hwa Yoon;Eun-Jung Kim
    • Korean Journal of Acupuncture
    • /
    • v.40 no.4
    • /
    • pp.184-193
    • /
    • 2023
  • Objectives : The purpose of this study is to understand the temperature characteristics depending on the thickness and material of the needle used with the Electronic Warm Acupuncture Device (EWAD). Methods : We controlled experimental environment and measured temperature changes of a silicon phantom in which K-type thermocouples were inserted at depths of 2, 7 mm. EWAD perfomed with acupuncture needles of various thicknesses (0.25×60 mm, 0.40×60 mm, and 0.50×60 mm) and materials (Gold 0.40×50 mm). We set non-needle (only heated with EWAD skin heater) group as a control group. Results : The maximum temperature and temperature changes of 0.40 mm, 0.50 mm needle group were significantly higher than the non-needle group. The highest temperature range in all needle groups was 0.50 mm needle group (41.44±0.31℃). However, the 0.25 mm needle group was not significantly different from the non-needle group. Maximum temperature of gold needle group was significantly higher than stainless steel needle group. Temperature changes of gold needle group were higher than stainless steel group at the depth of 7 mm. Conclusions : It was found that needle thickness and material of acupuncture had an effect on the temperature of the EWAD. When performing EWAD treatment, consideration of thickness and material of acupuncture is needed. Future research is needed using phantoms that can reflect actual clinical situations and better mimic the human body.

Research on the Development of Microneedle Arrays Based on Micromachining Technology and the Applicability of Parylene-C (미세가공 기술 기반의 마이크로니들 어레이 개발 및 패럴린 적용 가능성에 관한 연구)

  • Dong-Guk Kim;Deok-kyu Yoon;Yongchan Lee;Min-Uk Kim;Jihyoung Roh;Yohan Seo;Kwan-Su Kang;Young Hun Jeong;Kyung-Ah Kim;Tae-Ha Song
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.404-413
    • /
    • 2023
  • In this research, we studied the development of a SUS304 microneedle array based on microfabrication technology and the applicability of Parylene-C thin film, a medical polymer material. First of all, four materials commonly used in the field of medical engineering (SUS304, Ti, PMMA, and PEEK) were selected and a 5 ㎛ Parylene-C thin film was deposited. The applicability of Parylene-C coating to each material was confirmed through SEM analysis, contact angle measurement, surface roughness(Ra) measurement, and adhesion test according to ASTM standards for each specimen. Parylene-C thin film was deposited based on chemical vapor deposition (CVD), and a 5 ㎛ Parylene-C deposition process was established through trial and error. Through characteristic experiments to confirm the applicability of Parylene-C, SUS304 material, which is the easiest to apply Parylene-C coating without pretreatment was selected to develop a microneedle array based on CNC micromachining technology. The CNC micromachining process was divided into a total of 5 steps, and a microneedle array consisting of 19 needles with an inner diameter of 200 ㎛, an outer diameter of 400 ㎛, and a height of 1.4 mm was designed and manufactured. Finally, a 5 ㎛ Parylene-C coated microneedle array was developed, which presented future research directions in the field of microneedle-based drug delivery systems.

Guidelines for Transrectal Ultrasonography-Guided Prostate Biopsy: Korean Society of Urogenital Radiology Consensus Statement for Patient Preparation, Standard Technique, and Biopsy-Related Pain Management

  • Myoung Seok Lee;Min Hoan Moon;Chan Kyo Kim;Sung Yoon Park;Moon Hyung Choi;Sung Il Jung
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.422-430
    • /
    • 2020
  • The Korean Society of Urogenital Radiology (KSUR) aimed to present a consensus statement for patient preparation, standard technique, and pain management in relation to transrectal ultrasound-guided prostate biopsy (TRUS-Bx) to reduce the variability in TRUS-Bx methodologies and suggest a nationwide guideline. The KSUR guideline development subcommittee constructed questionnaires assessing prebiopsy anticoagulation, the cleansing enema, antimicrobial prophylaxis, local anesthesia methods such as periprostatic neurovascular bundle block (PNB) or intrarectal lidocaine gel application (IRLA), opioid usage, and the number of biopsy cores and length and diameter of the biopsy needle. The survey was conducted using an Internet-based platform, and responses were solicited from the 90 members registered on the KSUR mailing list as of 2018. A comprehensive search of relevant literature from Medline database was conducted. The strength of each recommendation was graded on the basis of the level of evidence. Among the 90 registered members, 29 doctors (32.2%) responded to this online survey. Most KSUR members stopped anticoagulants (100%) and antiplatelets (76%) one week before the procedure. All respondents performed a cleansing enema before TRUS-Bx. Approximately 86% of respondents administered prophylactic antibiotics before TRUS-Bx. The most frequently used antibiotics were third-generation cephalosporins. PNB was the most widely used pain control method, followed by a combination of PNB plus IRLA. Opioids were rarely used (6.8%), and they were used only as an adjunctive pain management approach during TRUS-Bx. The KSUR members mainly chose the 12-core biopsy method (89.7%) and 18G 16-mm or 22-mm (96.5%) needles. The KSUR recommends the 12-core biopsy scheme with PNB with or without IRLA as the standard protocol for TRUS-Bx. Anticoagulants and antiplatelet agents should be discontinued at least 5 days prior to the procedure, and antibiotic prophylaxis is highly recommended to prevent infectious complications. Glycerin cleansing enemas and administration of opioid analogues before the procedure could be helpful in some situations. The choice of biopsy needle is dependent on the practitioners' situation and preferences.

A multicenter comparative study of endoscopic ultrasound-guided fine-needle biopsy using a Franseen needle versus conventional endoscopic ultrasound-guided fine-needle aspiration to evaluate microsatellite instability in patients with unresectable pancreatic cancer

  • Tadayuki Takagi;Mitsuru Sugimoto;Hidemichi Imamura;Yosuke Takahata;Yuki Nakajima;Rei Suzuki;Naoki Konno;Hiroyuki Asama;Yuki Sato;Hiroki Irie;Jun Nakamura;Mika Takasumi;Minami Hashimoto;Tsunetaka Kato;Ryoichiro Kobashi;Yuko Hashimoto;Goro Shibukawa;Shigeru Marubashi;Takuto Hikichi;Hiromasa Ohira
    • Clinical Endoscopy
    • /
    • v.56 no.1
    • /
    • pp.107-113
    • /
    • 2023
  • Background/Aims: Immune checkpoint blockade has recently been reported to be effective in treating microsatellite instability (MSI)-high tumors. Therefore, sufficient sampling of histological specimens is necessary in cases of unresectable pancreatic cancer (UR-PC). This multicenter study investigated the efficacy of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) using a Franseen needle for MSI evaluation in patients with UR-PC. Methods: A total of 89 patients with UR-PC who underwent endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) or EUS-FNB using 22-G needles at three hospitals in Japan (2018-2021) were enrolled. Fifty-six of these patients (FNB 23 and FNA 33) were followed up or evaluated for MSI. Patient characteristics, UR-PC data, and procedural outcomes were compared between patients who underwent EUS-FNB and those who underwent EUS-FNA. Results: No significant difference in terms of sufficient tissue acquisition for histology was observed between patients who underwent EUS-FNB and those who underwent EUS-FNA. MSI evaluation was possible significantly more with tissue samples obtained using EUS-FNB than with tissue samples obtained using EUS-FNA (82.6% [19/23] vs. 45.5% [15/33], respectively; p<0.01). In the multivariate analysis, EUS-FNB was the only significant factor influencing the possibility of MSI evaluation. Conclusions: EUS-FNB using a Franseen needle is desirable for ensuring sufficient tissue acquisition for MSI evaluation.