• Title/Summary/Keyword: neck width

Search Result 197, Processing Time 0.026 seconds

The Effect of High Environmental Temperature and Nutrient Density on Pig Performance, Conformation and Carcass Characteristics under Restricted Feeding System

  • Hsia, L.C.;Lu, G.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.2
    • /
    • pp.250-258
    • /
    • 2004
  • An experiment was conducted to examine the effect of a high environmental temperature on the performance, conformation, and carcass characteristics of pigs and the influence of diet. Thirty-six three-way crossed castrated male pigs with average initial body weight of 50.4 kg were used in the experiment. The pig were allocated to the following treatments: two environmental temperatures (20 and $30^{\circ}C$)${\times}$three dietary energy levels (2,980, 3,300 and 3,600 kcal/kg)${\times}$three protein levels (12.8, 15.2 and 17.2%). Daily weight gain was lighter (p<0.01) and feed: gain ratio lower (p<0.05) in pigs at $30^{\circ}C$ than for pigs at $20^{\circ}C$ The pigs at $30^{\circ}C$ were significantly taller with deeper bodies (p<0.05) and significantly longer (p<0.05) both vertically horizontally in the planum nasal when kept at $30^{\circ}C$. The width of body and the circumference of the neck were greater (p<0.05) at $20^{\circ}C$. The lean meat of the loin, middle section, ham, and hind section were significantly greater (p<0.05) in pigs kept at $30^{\circ}C$ and the belly was significantly heavier. The total unsaturated free fatty acids were significantly higher (p<0.05) in the body fat of pigs kept at $20^{\circ}C$ than in that of pigs at $30^{\circ}C$. The results indicated that when pigs are given very restricted same amounts of feed, they may need less energy to maintain their body temperature under moderately high environmental temperature ($30^{\circ}C$); consequently, their performance is better than that of pigs under optimum environmental temperature. The results showed very clearly that weight gain of pigs increased with increasing of dietary protein and energy content. The increasing of dietary protein content seemed more significant when content increasing to 17.2% compared with the 12.8 and 15.2% protein content treatments. The increasing of dietary energy content was more significant when content increasing to 3,600 compared with the other low energy content treatments.

Upper Garment Sizing System for Obese School Boys Based on Somatotype Analysis (학령후기 비만 남아의 체형 분석에 따른 plus-size 남자 아동복 상의 치수 규격 제안)

  • Park, Soon-Jee
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.9
    • /
    • pp.99-112
    • /
    • 2008
  • The increasing rate of obesity in school aged children has become a conspicuous social phenomenon in Korea. This has been linked to greater economic growth, increasingly westernized dietary habits, and a consumer driven society. Given that obesity can lead to social exclusion or unfavorable attention by other students in a school setting, the design of plus-size garments have become important for effective appearance management skills. This research aimed to establish a somatotype database for obese school boys, aged 10 to 12, in order to develop a sizing system for plus-size upper garments. In order to measure somatotype of average and obese school boys, five categories were recorded; height, obesity, length of trunk, thickness of neck and chest. For obese boys, subcutaneous fat thickness and position of B.P/shoulder point factors were recorded. Obesity factor was subdivided into overall and specific ones, and while the deviation of obese body types was severe compared to the average type. Obese body type showed significantly higher measurements in width, girth, thickness. This is linked to the fact that the frequency ratio of obesity increases with age. Stature and chest were chosen as control dimensions for boys' wear. As crosstabulation of stature(5cm interval) and chest girth(2, 3 and 4cm), and stature(5cm interval)/chest girth(3cm interval) sizing system showed, the most effective cover ratio and adaptability to the data distribution $25{\sim}75$ quartile. Based on the findings, 10 sizes were formulated for average body type, while 18 sizes were formulated for obese type, whose size cover ratios were 48% and 62.9%, respectively. The primary ranges of stature were $145cm{\sim}150cm$, while those of chest girth were $79{\sim}82cm$. Each size was declared as "chest-somatotype{A(average)/O(obesity)-stature". This study proposed a plus-size upper garment sizing systems for obese boys, accompanied with reference measurements for suit, casual wear and underwear. The finding showed that the two systems were totally separate and not overlapping, meaning that plus-size sizing system is essential for obese school boys. The obesity type system had more size and wider range specs.

Ultrasonographic Evaluation of the Thyroid Glands, Jugular Vein and Carotid Artery in Horse (말에서 갑상선, 경정맥 및 경동맥의 초음파상)

  • 김명철;김용준;변홍섭;신상태;이경광;한용만;김병선
    • Korean Journal of Animal Reproduction
    • /
    • v.22 no.1
    • /
    • pp.67-72
    • /
    • 1998
  • Nowadays many kinds of foreign breed horse and Korean native Cheju horse are raised in Korea. Horse has complicated structure and function to maintain normal health, and to overcome severe condition during gallop at full speed. Sometimes the disease take a bad turn becuase of difficulty of correct diagnosis for horse disease. In recent times, horse farm for fattening and reproduction is gradually increasing. However, thoracic disease and abdominal disease are frequently occuring by defect in raising management. But the diagnosis of these kinds of disease is difficult by former diagnostic method. Ultrasonographic diagnostic method is a method to slove the problem. In abroad, nowadays ultrasonography has been reported for circulatory organs and abdomonal organs in horse, cattle, sheep, and dog, and the importance of ultrasonographic diagnosis is recognized in veterinary clinical medicine. In the country, ultrasonography of Korean native goat, cattle and dog was recently reported, but there was no report for the ultrasonography of horse. So, ultrasonogram for the thyroid glands, jugular vein and carotid artery was evaluated in Cheju horse and Thoroughbred horse. Thyroid gland, jugular vein and carotid artery were determined on both sides of neck. The length of right thyroid lobe at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 54.8, 45.1, 46.1 and 42.2 mm, respectively. The width of right thyroid lobe at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 18.1, 14.3, 14.6 and 14.2 mm, respectively. The height of right thyroid lobe at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 27.3, 25.6, 26.2 and 25.5 mm, respectively. Similar ultrasonographic measurements were obtained for the left thyroid gland. The internal diameter of left jugular vein at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 10.6, 9.7, 10.5 and 9.2 mm, respectively. Similar ultrasonographic measurements were obtained for the right jugular vein. The internal diameter of right carotid artery at the Thoroughbred horse, Thoroughbred foul, Cheju horse and Cheju foul were 9.5, 8.8, 9.1 and 8.5 mm, respectively. Similar ultrasonographic measurements were obtained for the left carotid artery. It is concluded that the ultrasonographic values of this study provides references for the diagnosis of morphologic changes in the thyroid gland, jugular vein and carotid artery in Korean native Cheju horse and Thoroughbred horse.

  • PDF

Three-dimensional finite element analysis for influence of marginal bone resorption on stress distribution in internal conical joint type implant fixture (변연골 흡수가 내측연결 임플란트 매식체의 응력분포에 미치는 영향)

  • Yun, Mi-Jung;Yoon, Min-Chul;Eom, Tae-Gwan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • Purpose: The change of the marginal bone around dental implants have significance not only for the functional maintenance but also for the esthetic success of the implant. The purpose of this study was to investigate the load transfer of internal conical joint type implant according to marginal bone resorption by using the three-dimensional finite element analysis model. Materials and methods: The internal conical joint type system was selected as an experimental model. Finite element models of bone/implant/prosthesis complex were constructed. A load of 300 N was applied vertically beside 3 mm of implant axis. Results: The pattern of stress distribution according to marginal bone resorption was similar. The maximum equivalent stress of implant was increase according to marginal bone resorption and the largest maximum equivalent stress was shown at model of 1 mm marginal bone resorption. Although marginal bone loss more than 1mm was occurred increasing of stress, the width of the stress increase was decreasing. Conclusion: According to these results, the exposure of thin neck portion of internal conical joint type implant is most important factor in stress increasing.

FINITE ELEMENT ANALYSIS OF WIDE DIAMETER SCREW IMPLANT PLACED INTO REGENERATED BONE (재생된 골에 식립한 넓은 직경의 나사형 임플란트에 대한 유한요소법적 분석)

  • Kim, Su-Gwan;Kim, Jae-Duk;Kim, Chong-Kwan;Kim, Byung-Ock
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.3
    • /
    • pp.248-254
    • /
    • 2005
  • The purpose of this study was to investigate the distribution of stress within the regenerated bone surrounding the implant using three dimensional finite element stress analysis method. Using ANSYS software revision 6.0 (IronCAD LLC, USA), a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The $5.0{\times}11.5-mm$ screw implant (3i, USA) was used for this study, and was assumed to be 100% osseointegrated. And it was restored with gold crown with resin filling at the central fossa area. The implant was surrounded by the regenerated type IV bone, with 4 mm in width and 7 mm apical to the platform of implant in length. And the regenerated bone was surrounded by type I, type II, and type III bone, respectively. The present study used a fine grid model incorporating elements between 250,820 and 352,494 and nodal points between 47,978 and 67,471. A load of 200N was applied at the 3 points on occlusal surfaces of the restoration, the central fossa, outside point of the central fossa with resin filling into screw hole, and the functional cusp, at a 0 degree angle to the vertical axis of the implant, respectively. The results were as follows: 1. The stress distribution in the regenerated bone-implant interface was highly dependent on both the density of the native bone surrounding the regenerated bone and the loading point. 2. A load of 200N at the buccal cusp produced 5-fold increase in the stress concentration at the neck of the implant and apex of regenerated bone irrespective of surrounding bone density compared to a load of 200N at the central fossa. 3. It was found that stress was more homogeneously distributed along the side of implant when the implant was surrounded by both regenerated bone and native type III bone. In summary, these data indicate that concentration of stress on the implant-regenerated bone interface depends on both the native bone quality surrounding the regenerated bone adjacent to implant and the load direction applied on the prosthesis.

A study on the bedrock erosional forms at Dutayeon, Yanggu (양구 두타연 인근 지역의 기반암 하상지형 연구)

  • KIM, Jong Yeon;KIM, Chang Hwan
    • Journal of The Geomorphological Association of Korea
    • /
    • v.19 no.2
    • /
    • pp.31-49
    • /
    • 2012
  • Satae cheon, a tributary of the Suip cheon in Yanggu, Gangwon province, is an international river extended to North Korea. Most of drainage basin area of the river was the fierce battle field during the Korean War(1950-1953) and hard to access as it located between the MDL(Military Demarcation Line) and the CCZ(Civilian Control Zone: about 10km south from MDL). By the restriction of access to the sites, most of natural landscape have been well conserved except limited use for military activities. Even the landfoms in that area were not studied, except the government's heritage reports. Satae Cheon's channel follows the Imdang fault line(N-S) to Satae-ri and flow to west to the Dutayeon area. The river meanders along geological structure or weak line at the Dutayeon area. The meandering channel was shorten by the meander cut which linked the thalweg line of meander loop ant the meander neck. As a result of this cut, the river cliff formed by the Satae cheon became the part of newly formed channel bed and the S-forms are formed. After the channel route stabilized, channel incised the rock with large potholes and undulating walls were formed. The channel width changes from 1m to 10m with restriction of the undulating walls, so this part can be regarded as inner channel or inner gorge. From the point of planar forms it also can be slot-type canyon.

Effects of Transcutaneous Electrical Stimulation on Physiological Symptoms and Psychological Satisfaction in Women With Stress Urinary Incontinence: A Preliminary Study

  • Kim, Ji-hyun;Kwon, Oh-yun;Jeon, Hye-seon;Hwang, Ui-jae;Gwak, Kyeong-tae;Yoon, Hyeo-bin;Park, Eun-young
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.67-75
    • /
    • 2019
  • Background: Stress urinary incontinence (SUI) is an involuntary leakage of urine from the urethra when intra-abdominal pressure increases, such as from sneezing, coughing, or physical exertion. It is caused by insufficient strength of the pelvic floor and sphincter muscles, resulting from vaginal delivery, obesity, hard physical work, or aging. The pelvic floor electrical stimulator is a conservative treatment generally used to relieve the symptoms of urinary incontinence. it recommended to applied before surgery is performed. Objects: The purpose of this study was to determine if the transcutaneous electrical stimulation (TCES) would be effective for the physiological symptoms and psychological satisfaction of women with SUI for an 8-weeks intervention. Methods: Easy-K is a specially designed user-friendly TCES. Five female who were diagnosed with SUI by a gynecologist but who did not require surgical intervention were included in this study. Intervention was implemented over an 8-week period. Outcome measures included vaginal ultrasonography, Levator ani muscle (LAM) contraction strength, incontinence quality of life (I-QOL), and female sexual function index (FSFI) questionnaires. Results: The bladder neck position significantly decreased across assessment time. Funneling index and urethral width significantly decreased after 8 weeks of intervention (p<.05). The bladder necksymphyseal distance and posterior rhabdosphincter thickness statistically increased and the anterior rhabdosphincter thickness showed a tendency to increase. All participants demonstrated a significant increase in the LAM contraction score across three assessment times (p<.05). Although the total score of the I-QOL did not show significant improvement, it steadily increased and among I-QOL subscales, only the "avoidance" subscale showed statistical improvements (p<.05). The total score of the FSFI statistically improved and the "desire" score significantly changed (p<.05). Conclusion: The TCES is recommended for women who want to apply conservative treatments before surgery and who have suffered from SUI in aspects of sexual function and quality of life.

Dose Distribution of Co-60 Photon Beam in Total Body Irradiation (Co-60에 의한 전신조사시 선량분포)

  • Kang, Wee-Saing
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.109-120
    • /
    • 1991
  • Total body irradiation is operated to irradicate malignant cells of bone marrow of patients to be treated with bone marrow transplantation. Field size of a linear accelerator or cobalt teletherapy unit with normal geometry for routine technique is too small to cover whole body of a patient. So, any special method to cover patient whole body must be developed. Because such environments as room conditions and machine design are not universal, some characteristic method of TBI for each hospital could be developed. At Seoul National University Hospital, at present, only a cobalt unit is available for TBI because source head of the unit could be tilted. When the head is tilted outward by 90$^{\circ}$, beam direction is horizontal and perpendicular to opposite wall. Then, the distance from cobalt source to the wall was 319 cm. Provided that the distance from the wall to midsagittal plane of a patient is 40cm, nominal field size at the plane(SCD 279cm) is 122cm$\times$122cm but field size by measurement of exposure profile was 130cm$\times$129cm and vertical profile was not symmetric. That field size is large enough to cover total body of a patient when he rests on a couch in a squatting posture. Assuming that average lateral width of patients is 30cm, percent depth dose for SSD 264cm and nominal field size 115.5cm$\times$115.5cm was measured with a plane-parallel chamber in a polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom of size 25cm wide and 30cm deep. Depth of dose maximum, surface dose and depth of 50% dose were 0.3cm, 82% and 16.9cm, respectively. A dose profile on beam axis for two opposing beams was uniform within 10% for mid-depth dose. Tissue phantom ratio with reference depth 15cm for maximum field size at SCD 279cm was measured in a small polystyrene phantom and was linear over depth range 10~20cm. An anthropomorphic phantom with TLD chips inserted in holes on the largest coronal plane was bilaterally irradiated by 15 minute in each direction by cobalt beam aixs in line with the cross line of the coronal plane and contact surface of sections No. 27 and 28. When doses were normalized with dose at mid-depth on beam axis, doses in head/neck, abdomen and lower lung region were close to reference dose within $\pm$ 10% but doses in upper lung, shoulder and pelvis region were lower than 10% from reference dose. Particulaly, doses in shoulder region were lower than 30%. On this result, the conclusion such that under a geometric condition for TBI with cobalt beam as SNUH radiotherapy departement, compensators for head/neck and lung shielding are not required but boost irradiation to shoulder is required could be induced.

  • PDF

Evaluation on the Radiation Exposure of Radiation Workers in Proton Therapy (양성자 치료 시 방사선 작업 종사자에게 미치는 방사선 피폭에 대한 평가)

  • Lee, Seung-Hyun;Jang, Yo-Jong;Kim, Tae-Yoon;Jeong, Do-Hyung;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Purpose: Unlike the existing linear accelerator with photon, proton therapy produces a number of second radiation due to the kinds of nuclide including neutron that is produced from the interaction with matter, and more attention must be paid on the exposure level of radiation workers for this reason. Therefore, thermoluminescence dosimeter (TLD) that is being widely used to measure radiation was utilized to analyze the exposure level of the radiation workers and propose a basic data about the radiation exposure level during the proton therapy. Materials and Methods: The subjects were radiation workers who worked at the proton therapy center of National Cancer Center and TLD Badge was used to compare the measured data of exposure level. In order to check the dispersion of exposure dose on body parts from the second radiation coming out surrounding the beam line of proton, TLD (width and length: 3 mm each) was attached to on the body spots (lateral canthi, neck, nipples, umbilicus, back, wrists) and retained them for 8 working hours, and the average data was obtained after measuring them for 80 hours. Moreover, in order to look into the dispersion of spatial exposure in the treatment room, TLD was attached on the snout, PPS (Patient Positioning System), Pendant, block closet, DIPS (Digital Image Positioning System), Console, doors and measured its exposure dose level during the working hours per day. Results: As a result of measuring exposure level of TLD Badge of radiation workers, quarterly average was 0.174 mSv, yearly average was 0.543 mSv, and after measuring the exposure level of body spots, it showed that the highest exposed body spot was neck and the lowest exposed body spot was back (the middle point of a line connecting both scapula superior angles). Investigation into the spatial exposure according to the workers' movement revealed that the exposure level was highest near the snout and as the distance becomes distant, it went lower. Conclusion: Even a small amount of exposure will eventually increase cumulative dose and exposure dose on a specific body part can bring health risks if one works in a same location for a long period. Therefore, radiation workers must thoroughly manage exposure dose and try their best to minimize it according to ALARA (As Low As Reasonably Achievable) as the International Commission on Radiological Protection (ICRP) recommends.

  • PDF

Tensile Performance of Machine-Cut Dovetail Joint with Larch Glulam (낙엽송집성재를 이용한 기계프리커트 주먹장접합부의 인장성능)

  • Park, Joo-Saeng;Hwang, Kweon-Hwan;Park, Moon-Jae;Shim, Kug-Bo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.3
    • /
    • pp.199-204
    • /
    • 2010
  • Members used for the Korean traditional joints have been processed by handicraft, especially with domestic red pine species. Dovetail joint is most commonly used in woodworking joinery and traditional horizontal and vertical connections. It is able to be processed much easier to cut by handicraft and machines. However, although it is processed straight forwards, it requires a high degree of accuracy to ensure a snug fit. Also, tenons and mortises must fit together with no gap between them so that the joint interlocks tightly. A few scientific studies on the dovetail joints have been conducted so far. For the effective applications of traditional joints and domestic plantation wood species, dovetail joints were assembled by larch glulam members processed by machine pre-cut. To identify the tensile properties of through dovetail joints, larch glulam with 150 150mm in cross section were prepared. Furthermore, various geometric parameters of dovetai joints such as width, length, and tenon angle, were surveyed. The ends in the mortise was cracked mainly at a low strength level in the control specimens without reinforcements. The maximum tensile strengths of reinforced specimens considering real connections such as capital joint and headpiece on a column, increasedby handicraft, especially with domestic red pine species. Dovetail joint is most commonly used in woodworking joinery and traditional horizontal and vertical connections. It is able to be processed much easier to cut by handicraft and machines. However, although it is processed straight forwards, it requires a high degree of accuracy to ensure a snug fit. Also, tenons and mortises must fit together with no gap between them so that the joint interlocks tightly. A few scientific studies on the dovetail joints have been conducted so far. For the effective applications of traditional joints and domestic plantation wood species, dovetail joints were assembled by larch glulam members processed by machine pre-cut. To identify the tensile properties of through dovetail joints, larch glulam with 150 150mm in cross section were prepared. Furthermore, various geometric parameters of dovetai joints such as width, length, and tenon angle, were surveyed. The ends in the mortise was cracked mainly at a low strength level in the control specimens without reinforcements. The maximum tensile strengths of reinforced specimens considering real connections such as capital joint and headpiece on a column, increased by two times with shear failures on the tenon than the control specimens. The maximum tensile strength was obtained in the specimen of 25 degrees, and no difference was observed in the changes of neck widths.