• 제목/요약/키워드: near-infrared reflectance spectroscopy

검색결과 214건 처리시간 0.024초

근적외선 확산반사 분광법을 이용한 흉터치료 평가 (Evaluation of the Scar Treatment using Near Infrared Diffuse Reflectance Spectroscopy)

  • 장익제;윤종인
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권1호
    • /
    • pp.53-60
    • /
    • 2016
  • Monitoring of dermal collagen is important to assess various scar conditions, and many diagnostic methods have been applied to quantify collagen contents in scar tissue. In this study, Monte Carlo simulation was used to evaluate diffuse reflectance distributions in scar condition by a near-infrared laser source. The results showed that the effective distance of the light source and the detector was 2 mm to monitor the various scar conditions using diffuse reflectance spectroscopy. This study may suggest to the optimal design for a near infrared diffuse reflectance spectroscopy during the scar treatment.

Near Infrared Diffuse Reflectance Spectroscopy to Measure Pulmonary Edema

  • Larry Leonardi;David H.Burns;Luis Openheimer;Rene P.Michel
    • Near Infrared Analysis
    • /
    • 제2권1호
    • /
    • pp.43-53
    • /
    • 2001
  • A non-invasive spectroscopic method is presented for the measurement of pulmonary edema. Both early diagnosis and quantitative edema estimates were investigated. The spectroscopic determination of pulmonary edema involved the acquisition of diffuse reflectance spectra in the near-infrared (NIR) region with change in water concentration - water is the main constituent of edema fluid. Pulmonary edema was induced into the excised perfused lungs of seven animals by elevating the hydrostatic pressure. Estimates of edema were ascertained from a partial least squares regression of the measured spectral response. Actual edema was determined from the change (increase) in total lung weight. Estimates in relative lung weight increases due to in vitro edema were made with the near infrared spectra. The results revealed that fluid accumulation produced spectral changes in the O-H and C-H absorptions as well as scattering changes in the spectra. Histology of the lung was used to verify the presence or absence of interstitial and alveolar edema. Results demonstrated that near infrared spectroscopy might provide a new tool for clinical assessment of pulmonary edema.

조사료 가치 평가를 위한 근적외선 분광법(NIRS)의 활용 (Applications of Near Infrared Reflectance Spectroscopy(NIRS) in Forage Evaluation)

  • 박형수;이종경;이효원
    • 한국초지조사료학회지
    • /
    • 제24권1호
    • /
    • pp.81-90
    • /
    • 2004
  • Farmers need timely information on the nutritional status of their animals and the nutritive value of pastures and supplementary feeds if they are to apply successfully this existing nutritional information. Near infrared reflectance(NIR) spectroscopy has been used over the last forty years to analyse accurately protein, fiber, and other organic components in animal foods. NIR spectroscopy is a rapid, non-destructive, and non-polluting technology. When properly calibrated, NIR spectroscopy is used successfully with both concentrate and forage feeds. NIR methods predict in vitro digestibility accurately and precisely, and can predict in vivo digestibility at least as well as conventional "wet chemistry" methods such as in vivo digestion or the pepsin-cellulase method, and much more rapidly. NIR technology has been applied to the routine monitoring (through analysis of feces samples) of the nutritional status of cattle and other grazing animals. This report reviews the use of near infrared reflectance(NIR) spectroscopy to monitor the nutritive value of animal feeds and the nutritional status of grazing animals.

Near Infrared Reflectance Spectroscopy for Non-Invasive Measuring of Internal Quality of Apple Fruit

  • Sohn, Mi-Ryeong;Park, Woo-Churl;Cho, Rae-Kwang
    • Near Infrared Analysis
    • /
    • 제1권1호
    • /
    • pp.27-30
    • /
    • 2000
  • In this study, we investigated the feasibility of non-destructive determination of internal quality factors of Fuji apple fruit using near infrared(NIR) reflectance spectroscopy and developed the calibration models. As the reference methods, refractometer, titration and texture analyzer for sugar content, acidity and firmness were used, respectively. Samples were scanned from 1100∼2500nm with InfraAlyzer 500C spectrometer and SESAME software was used for data analysis. A multiple linear regression(MLR) analysis was performed to develop the calibrations. The correlation coefficient(R) and standard error of prediction(SEP) were as follows; 0.91, 0.41$^{\circ}$Brix for sugar content, 0.90, 0.04% for acidity and 0.84, 0.094 kg for firmness, respectively. This study shows that NIR spectroscopy can be used to evaluate the sugar content acidity and firmness of apple fruit with acceptable accuracy.

Near Infrared Reflectance Spectroscopy(NIRS)에 의한 음식물 쓰레기 퇴비 분석에 관한 연구 (Analysis on Food Waste Compost by Near Infrared Reflectance Spectroscopy(NIRS))

  • 이효원;길동용
    • 한국유기농업학회지
    • /
    • 제13권3호
    • /
    • pp.281-289
    • /
    • 2005
  • In order to find out an alternative way of analysis of food waste compost, the Near Infrared Reflectance Spectroscopy(NIRS) was used for the compost assessment because the technics has been known as non-detructive, cost-effective and rapid method. One hundred thirty six compost samples were collected from Incheon food waste compost factory at Namdong Indurial Complex. The samples were analyzed for nitrogen, organic matter (OM), ash, P, and K using Kjedahl, ignition method, and acid extraction with spectrophotometer, respectively. The samples were scanned using FOSS NIRSystem of Model 6500 scanning mono-chromator with wavelength from $400\~2,400nm$ at 2nm interval. Modified partial Least Squares(MPLS) was applied to develop the most reliable calibration model between NIR spectra and sample components such as nitrogen, ash, OM, P, and K. The regression was validated using validation set(n=30). Multiple correlation coefficient($R^2$) and standard error of prediction(SEP) for nitrogen, ash, organic matter, OM/N ratio, P and K were 0.87, 0.06, 0.72, 1.07, 0.68, 1.05, 0.89, 0.31, 0.77, 0.06, and 0.64, 0.07, respectively. The results of this experiment indicates that NIRS is reliable analytical method to assess some components of feed waste compost, also suggests that feasibility of NIRS can be Justified in case of various sample collection around the year.

  • PDF

Predicting Soil Chemical Properties with Regression Rules from Visible-near Infrared Reflectance Spectroscopy

  • Hong, Suk Young;Lee, Kyungdo;Minasny, Budiman;Kim, Yihyun;Hyun, Byung Keun
    • 한국토양비료학회지
    • /
    • 제47권5호
    • /
    • pp.319-323
    • /
    • 2014
  • This study investigates the prediction of soil chemical properties (organic matter (OM), pH, Ca, Mg, K, Na, total acidity, cation exchange capacity (CEC)) on 688 Korean soil samples using the visible-near infrared reflectance (VIS-NIR) spectroscopy. Reflectance from the visible to near-infrared spectrum (350 to 2500 nm) was acquired using the ASD Field Spec Pro. A total of 688 soil samples from 168 soil profiles were collected from 2009 to 2011. The spectra were resampled to 10 nm spacing and converted to the 1st derivative of absorbance (log (1/R)), which was used for predicting soil chemical properties. Principal components analysis (PCA), partial least squares regression (PLSR) and regression rules model (Cubist) were applied to predict soil chemical properties. The regression rules model (Cubist) showed the best results among these, with lower error on the calibration data. For quantitatively determining OM, total acidity, CEC, a VIS-NIR spectroscopy could be used as a routine method if the estimation quality is more improved.

ESTIMATION OF SUGAR AND REDUCING SUGAR IN MOLASSES USING NEAR INFRARED REFLECTANCE SPECTROSCOPY

  • Mehrotra, Ranjana;Gupta, Alka;Tewari, Jagdish;Varma, S.P.
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1258-1258
    • /
    • 2001
  • Estimation of sugar and reducing sugar content in molasses is very important task in sugar refineries. Conventional methods of determination of sugar content in molasses samples are highly time consuming and employ hazardous chemicals. Due to the physical properties of molasses, probability of error in conventional analytical techniques is high. These methods have proven to be inefficient for a process control in any sugar industry. Hence development of a rapid, inexpensive, physical and also accurate method for sugar determination in molasses will be highly useful. Near Infrared spectroscopy is being widely used worldwide as an analytical technique in food industry. The technique offers the advantage of being non-destructive and rapid. The present paper highlights the potential of near infrared reflectance spectroscopy as a rapid and automated analytical technique for determination of sugar and reducing sugar content in molasses. A number of molasses samples were collected during and after the sugar season from Havana Sugar Industry, Havana. The samples were chosen so as to obtain a wide range of concentration of sugar and reducing sugars. This was done in order to achieve a good calibration curve with widely spread data points. These samples were scanned in the region of 1100 - 2500 nm in diffuse reflectance mode. An indigenous ELICO NIR spectrophotometer, modified according to the requirements of sugar industry was used for this purpose. Each sample was also analyzed simultaneously by standard chemical methods. Chemical values were taken as reference for near infrared analysis. In order to obtain the most accurate calibration for the set of samples, various mathematical treatments were employed. Partial Least Square method was found to be most suitable for the analysis. A comparison is made between the actual values (chemical values) and the predicted values (NIR values). The actual values agree very well with the predicted values showing the accuracy of the technique. The validity of the technique is checked by predicting the concentration of sugar in unknown molasses samples using the calibration curve. The present investigation assesses the feasibility of the technique for on-line monitoring of sugars present in molasses in sugar industries.

  • PDF

근적외선 분광분석법을 이용한 유량종자의 원산지 판별 (Discrimination of Oil Seeds According to Geographical Origin Using Near Infrared Reflectance Spectroscopy)

  • 권혜순
    • 한국응용과학기술학회지
    • /
    • 제16권1호
    • /
    • pp.21-24
    • /
    • 1999
  • Sesame seed (Sesamum indicum L.) is an important seasoning in Korea and most korean consumer tend to eat the korean sesame seed as the best than other ones produced in oriental countries such as China and Japan. Near infrared reflectance spectroscopy (NIRS) was applied for discrimination according to geographical origin (Korea, China and so on) of sesame seeds. Near-infrared spectroscopy among the many kinds of techniques could provide a rapid screening, low cost solution to discriminate geographical origin of sesame seed. The objective of this study is to determine if NIR technique could be used to discriminate between the korean sesame seed and non-korean sesame seed by using the new method. Rapid, precise and nondestructive analysis method for determination of the geographic origin of sesame seeds were discriminated relative accurately according to geographical origin using PLS regression method.

Near Infrared Spectroscopy for Measuring Soil Properties

  • Ryu, Kwan-Shig;Kim, Bok-Jin;Park, Woo-Churl;Cho, Rae-Kwang
    • Near Infrared Analysis
    • /
    • 제1권1호
    • /
    • pp.37-41
    • /
    • 2000
  • The purpose of this research was to develop a the reflection technique with near infrared (NIR) radiation for estimating soil components. NIR reflectance was scanned at 2nm intervals from 1100 to 2500nm with an InfraAlyzer 500 (Bran & Luebbe Co.). Over 400 soil sample from fields of different crops and land-use over Youngnam and Honam regions were used to obtain mean diffuse reflection of the soil for the calibration and validation of the calibration set in estimating moisture, organic matter (OM) and total nitrogen (T-N) of the soils. Multiple linear regression (MLR) was used to evaluate the correlation of NIR spectroscopy method. Reflection pattern of NIR spectra for finely sized sample (<0.5mm) and coarsely sized soil(<2mm) did not show much difference. The results showed that NIR spectroscopy and coarsely sized soil (<2mm) did not show much difference. The results showed that NIR spectroscopy could be used as a routine soil testing method in estimating OM, moisture, T-N in soil samples simultaneously.