• 제목/요약/키워드: near-P.D-A

검색결과 275건 처리시간 0.031초

Efficient excitation and amplification of the surface plasmons

  • Iqbal, Tahir
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1381-1387
    • /
    • 2018
  • One dimensional (1D) grating has been fabricated (using focused ion beam) on 50 nm gold (Au) film deposited on higher refractive index Gallium phosphate (GaP) substrate. The sub-wavelength periodic metal nano structuring enable to couple photon to couple with the surface plasmons (SPs) excited by them. These grating devices provide the efficient control on the SPs which propagate on the interface of noble metal and dielectric whose frequency is dependent on the bulk electron plasma frequency of the metal. For a fixed periodicity (${\Lambda}=700 nm$) and slit width (w = 100 nm) in the grating device, the efficiency of SPP excitation is about 40% compared to the transmission in the near-field. Efficient coupling of SPs with photon in dielectric provide field localisation on sub-wavelength scale which is needed in Heat Assisted Magnetic recording (HAMR) systems. The GaP is also used to emulate Vertical Cavity Surface emitting laser (VCSEL) in order to provide cheaper alternative of light source being used in HAMR technology. In order to understand the underlying physics, far-and near-field results has been compared with the modelling results which are obtained using COMSOL RF module. Apart from this, grating devices of smaller periodicity (${\Lambda}=280nm$) and slit width (w = 22 nm) has been fabricated on GaP substrate which is photoluminescence material to observe amplified spontaneous emission of the SPs at wavelength of 805 nm when the grating device was excited with 532 nm laser light. This observation is unique and can have direct application in light emitting diodes (LEDs).

p-version 무한요소를 적용한 지반-구조물 상호작용해석의 계산속도 향상 (A Speed-Up in Computing Time for SSI Analysis by p-version Infinite Elements)

  • 임재성;손일민;김재민;서춘교
    • 한국전산구조공학회논문집
    • /
    • 제29권5호
    • /
    • pp.471-482
    • /
    • 2016
  • 이 연구에서는 p-version 동적무한요소법을 도입함으로써 FE-IE 기법에 기반한 KIESSI-3D 프로그램의 속도향상에 역점을 두었다. KIESSI-3D의 성능을 평가하기 위해 8가지 실규모 SSI 문제에 대한 수치해석을 수행하였다. 이를 위해 근역지반 모델의 반경($r_0$)이 구조물기초 반경(R)의 1.2배, 1.5배, 3.0배인 KIESSI-3D 해석모델을 고려하였다. 또한 SASSI2010 프로그램을 이용한 SSI 해석을 수행하였으며, 이 결과를 KIESI-3D에 의한 결과와 정확성 및 계산속도를 비교하였다. 수치해석 결과, 인 KIESI-3D 모델을 사용하면 정확한 해석을 수행할 수 있음을 알 수 있었다. 계산속도 측면을 보면, 새로운 KIESSI-3D의 해석속도는 기존 KIESSI-3D에 비해 최대 25배 빠른 것으로 나타났다.

Interaction of Cu(II)-meso-tetrakis(n-N-methylpyridiniumyl)porphyrin (n = 2,3,4) with Native and Synthetic Polynucleotides Probed by Polarized Spectroscopy

  • Lee, Mi-Jin;Lee, Gil-Jun;Lee, Dong-Jin;Kim, Seog-K.;Kim, Jong-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권11호
    • /
    • pp.1728-1734
    • /
    • 2005
  • The interactions of Cu(II)-meso-Tetrakis(n-N-methylpyridiniumyl)porphyrin (n = 2,3,4), respectively referred to as o-, m- and p-CuTMPyP, and DNA, poly$[d(A-T)_2]$ and poly$[d(G-C)_2]$ were investigated by circular and linear dichroism (CD and LD). In the o-CuTMPyP case, in which the rotation of the pyridinium ring is prevented, the shape of the CD spectrum when associated to DNA and poly$[d(A-T)_2]$ resembles and is characterized by a positive band at a low drug to DNA concentration ratio (R ratio) and is bisignate at a high R ratio. The former CD spectrum shape has been attributed to porphyrin that is bound monomerically outside of DNA while the latter can be attributed to those that are stacked. When o-CuTMPyP is bound to poly$[d(G-C)_2]$, the excitonic CD appeared at a relatively high R ratio. In contrast, a characteristic negative CD band in the Soret region was apparent for both m- and p-CuTMPyP when bound to DNA and poly$[d(G-C)_2]$ at the low R ratios, indicating that the porphyrin molecule intercalates. However, the DNA is bent near the intercalation site and the plane of the porphyrin molecule tilts relative to the DNA helix axis, as judged by the magnitude of the reduced LD. Various stacking patterns were identified by the shape of the CD spectrum for m- and p-CuTMPyP when bound to poly$[d(A-T)_2]$. Three species for the former complex and two for the latter complex were found which may reflect the extent of the stacking.

비접촉 마이크로웨이브 프루브 시스템의 I/Q Demodulator를 위한 MMIC Mixer의 설계 (A Design of MMIC Mixer for I/Q Demodulator of Non-contact Near Field Microwave Probing System)

  • 류근관;김성찬
    • 한국정보통신학회논문지
    • /
    • 제16권5호
    • /
    • pp.1023-1028
    • /
    • 2012
  • 본 논문에서는 비접촉 마이크로웨이브 프루브 시스템의 I/Q demodulator를 위한 MMIC (Monolithic Microwave Integrated Circuit) mixer chip을 GaAs p-HEMT 공정의 Schottky 다이오드를 이용하여 설계 및 제작하였다. 프루브 시스템의 I/Q demodulator 구조를 단순화하기 위해 single balanced 구조의 mixer를 채택하였다. Single balanced mixer에서 $90^{\circ}$hybrid coupler와 ${\lambda}/4$ 전송선로를 이용하여 $180^{\circ}$hybrid를 설계하였으며 이를 MIM 커패시터와 spiral 인덕터를 이용하여 구현함으로써 mixer chip의 크기를 줄일 수 있었다. On-wafer 측정 결과, 본 논문의 MMIC mixer는 1650MHz ~ 2050MHz의 RF 및 LO 주파수 대역을 포함하고 있으며, 응용 주파수 대역 내에서 RF 및 LO의 변화에 대해 약 12dB 이하의 평탄한 변환손실(conversion loss) 특성을 나타내었다. 또한, MMIC mixer chip은 $2.5mm{\times}1.7mm$의 초소형 크기를 가지며 LO-IF 및 RF-IF의 격리도는 각각 43dB 및 23dB 이상의 특성을 나타내었다.

고빌리루빈혈증이 유도된 신생자돈에서 근적외석 발광기를 이용한 뇌 혈역학적 변화에 대한 연구 (Near-Infrared Spectroscopy for Monitoring Cerebral Hemodynamics in Hyperbilirubinemia-induced Newborn Piglets)

  • 황종희;최창원;장윤실;박원순
    • Clinical and Experimental Pediatrics
    • /
    • 제48권6호
    • /
    • pp.649-654
    • /
    • 2005
  • 목 적 : 본 연구는 고빌리루빈혈증이 유도된 신생자돈에서 비 침습적인 NIRS을 통한 뇌의 혈역학적 변화에 대해 알아보고자 하였다. 방 법 : 17 마리의 신생자돈을 대상으로 정상 대조군(CG, n=6), 고빌리루빈혈증군(BG, n=7마리), 7-NI를 투여한 고빌리루빈 혈증군(NG, n=4)으로 무작위 구분하였다. 고빌리루빈혈증의 유도는 40 mg/kg의 빌리루빈을 농축괴로 정주한 후 곧 이어 30mg/kg/hr로 4시간 동안 지속 정주하여 혈중 빌리루빈 농도를 20 mg/dL 이상으로 유지하였고 7-NI는 빌리루빈을 농축괴로 투여한 전과 후에 50 mg/kg을 복막투여 하였다. 모든 실험군은 실험 기간 동안 뇌의 혈역학적 변화를 위해 NIRS로 감시하였고 뇌 조직을 적출하여 생화학적인 변화를 관찰하였다. 결 과 : 동맥혈의 base excss, pH, 평균 동맥압은 BG군과 NG군에서 CG군에 비해 유의하게 감소하였다. BG군에서 유의하게 뇌 조직의 $Na^+$, $K^+$-ATPase activity, ATP, PCr은 유의하게 감소하고 conjugated dienes는 유의하게 증가하였으나 NG 군은 이런 이상소견이 유의하게 완화되었다(P<0.05). 뇌 혈역학적 검사상 [$HbO_2$], [HbT], 및 [HbD]는 BG군에서 CG군에 비해 유의하게 감소하였고(P<0.05) NG군은 CG군과 차이가 없었다. 실험 종료시 $ScO_2$는 세 군간에 유의한 차이가 없었다. 결 론 : 고빌리루빈혈증이 유도된 신생자돈에서 뇌의 혈역학적인 변화를 비침습적인 NIRS의 감시를 통해 유용하게 관찰할 수 있었다.

근시와 정시 사이에서 근거리 작업의 결과로서 각막 지도 변화와 비교 (Comparison of the Corneal Topography Changes as a Result of Near Task between Myopes and Emmetropes)

  • ;;김덕훈
    • 한국안광학회지
    • /
    • 제8권1호
    • /
    • pp.11-15
    • /
    • 2003
  • 이 연구의 목적은 근시와 정시에서 근거리 작업의 결과로서 각막 지도의 변화를 조사한 것이다. 18세에서 24세 사이의 30명의 대학생을 무작위로 선택하였다. 그들은 각각 15명씩의 두 굴절 그룹으로 분류하였다. 즉 근시와 정시로 하였다. 각 피검자의 각박 지도는 Eye-Sys Videokeratography system으로 측정하였다. 측정은 근거리 작업의 30분 전후에 수행하였다(복사한 N10 교체를 20cm 근거리에서 수행함). 자극 받은 케라토 미터와 반경선 케라토미터 지도 프로그램은 자료의 분석에 사용하였다. 우리의 결과들은 단지 정시를 위한 근거리 작업 후 각막 지도의 중심 부위(3 mm)의 가장 연명한 경선에서 유의성 변화(P<0.005)의 발견을 제외하고는 근시와 정시 모두에 근거리 작업의 결과로서 자극된 케라토 미터와 반경선 나타남은 유의성을 가지는 변화는 없는 것으로 나타났다. 우리는 각막 지도는 근시와 정시 모두에서 근거리 작업의 결과로서 의미 있는 변화가 없다는 것을 결론지었다.

  • PDF

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

  • Ozay Onoral;Sevcan Kurtulmus-Yilmaz;Dilem Toksoy;Oguz Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권6호
    • /
    • pp.290-301
    • /
    • 2023
  • PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

한국 어린이의 안축장과 신체 계측치와의 관련성 (Association between Axial Length and Anthropometric Value in Korean Children)

  • 김효진;류정묵
    • 한국안광학회지
    • /
    • 제19권3호
    • /
    • pp.397-402
    • /
    • 2014
  • 목적: 본 연구는 한국 어린이를 대상으로 안축장과 신체 계측치와의 관련성을 조사하였다. 방법: 서울지역에서 11-12세(평균 연령: $11.95{\pm}0.22$세, 여학생: 45.0%)의 초등학생 40명을 대상으로 하였다. 부분 간섭측정법에 의한 안축장, 각막 곡률반경, 굴절이상도, 신장(m), 그리고 체중(kg)을 측정하였고, 체질량지수(BMI $[kg/m^2]=weight/[height]^2$)와 비만정도지수(DO[%]=[actual weightstandard weight]/standard weight)는 계산하였다. 근업 활동으로 1일 평균 독서시간, TV 시청시간, 그리고 컴퓨터 사용시간에 대하여 설문하였다. 결과: 전체 대상자의 평균 굴절이상도는 $1.06{\pm}0.84D$였고, 이들의 안축장과 몸무게(r=0.427, p=0.006), 체질량지수(r=0.508, p=0.001), 비만정도지수(r=0.371, p=0.018)는 유의한 양의 상관관계를 보였다. 또한 안축장은 체중(p=0.041)과 체질량지수(p=0.015)의 1사분위수, 그리고 비만정도지수가 가장 높은 그룹(p=0.042)에서 유의하게 길었다. 연령, 성별, 그리고 근업 활동을 보정한 후에 다중회귀분석에서 체중, 체질량지수 그리고 비만정도지수는 안축장과 유의한 관련성을 보였고, 특히, 근업 활동에서 1일 독서시간은 안축장과 유의한 관련성을 보였다. 결론: 한국 초등학생의 안축장은 체중과 관련이 있었다. 특히, 긴 안축장과 1일 독서시간은 유의한 관계를 보였다.

NEAR-IR PHOTOMETRIC AND OPTICAL SPECTROSCOPIC STUDY OF THE FU ORIONIS OBJECT V582 AURIGAE

  • OH, HYUNG-IL;YOONY, TAE SEOG;SUNG, HYUN-IL
    • 천문학논총
    • /
    • 제30권2호
    • /
    • pp.269-270
    • /
    • 2015
  • We carried out near-IR photometric and optical spectroscopic observations of V582 Aur, which is a FU Orionis type object, to investigate any periodic and/or aperiodic variations. We obtained light curves on the scale of a night and a year, in J, H and Ks bands with KASINICS (KASI Near Infrared Camera System) attached to the BOAO (Bohyun-san Optical Astronomy Observatory) 1.8-m reflector in Youngcheon, South Korea and examined photometric variations on the two time scales. So far we have not found any periodic brightness variations on the scale of a night. On the other hand, we have found that there seems to be a periodic brightness variation with a period of approximately 45 days. In addition, high-resolution optical spectroscopic observations of V582 Aur were performed from February 2013 to May 2014 with the high-resolution echelle spectrograph BOES attached to the BOAO 1.8-m reflector. We analyzed several spectral lines to understand the physical state of V582 Aur. The P Cyg profiles are clearly shown in the $H{\alpha}$ line and Na I D line.

Nondestructive determination of physico-chemical properties in compost by NIRS

  • Seo, Sang-Hyun;Lee, Chang-Hee;Park, Sung-Hun;Cho, Rae-Kwang;Park, Woo-Churl
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1622-1622
    • /
    • 2001
  • The purpose of this research was to develop a the reflection technique with near infrared (NIR) radiation for estimating physico-chemical properties in compost. The composts (cattle, pig, chicken and waste composts) were air dried and then ground to pass through a 0.5 or 2mm sieve for the physico-chemical properties and spectroscopic determinations. The physico-chemical properties of compost were shown high values ; moisture(30-60%), T-N(0.8-2.9%), organic matter(29-89%), pH(5.89-9.60) K$_2$O(0.27-5.66%), P2O$\sub$5/(0.07-2.62%), CaO(0.03-4.80%), MgO(0.09-1.56%), NaCl(0.01-1.13%), EC(1.41-13.76dS/m). Generally, we should select a simple calibration and prediction method for determining physico-chemical properties in compost under similar accuracy and precision of prediction. It should be remembered that the NIRS approach will never replace the traditional methods. However, NIRS technique may be an effective method for rapid and nondestructive measurements of a large number of compost samples. Near infrared reflectance spectra of composts was obtained by Infra Alyzer 500 scanning spectrophotometer at 2-nm intervals from 1100 to 2500nm. Multiple linear regression(MLR) or partial least square regression (PLSR) was used to evaluate a NIRS method for the rapid and nondestructive determination of physico-chemical properties and humic acid contents in composts. The standard error of prediction(SEP) for finely sized sample(<0.5mm) and coarsely sized sample(<2mm) did not show much difference. The NIR instrument of filter type showed the same accuracy of the monochromator scanning type to estimate the compost properties. The results summarized that NIR spectroscopy can be used as a routine testing method to determine quantitatively the OM, moisture, T-N, color, pH, cation content in the compost samples nondestructively.

  • PDF