• 제목/요약/키워드: near infrared reflection

검색결과 48건 처리시간 0.022초

Near Infrared Spectroscopy for Measuring Soil Properties

  • Ryu, Kwan-Shig;Kim, Bok-Jin;Park, Woo-Churl;Cho, Rae-Kwang
    • Near Infrared Analysis
    • /
    • 제1권1호
    • /
    • pp.37-41
    • /
    • 2000
  • The purpose of this research was to develop a the reflection technique with near infrared (NIR) radiation for estimating soil components. NIR reflectance was scanned at 2nm intervals from 1100 to 2500nm with an InfraAlyzer 500 (Bran & Luebbe Co.). Over 400 soil sample from fields of different crops and land-use over Youngnam and Honam regions were used to obtain mean diffuse reflection of the soil for the calibration and validation of the calibration set in estimating moisture, organic matter (OM) and total nitrogen (T-N) of the soils. Multiple linear regression (MLR) was used to evaluate the correlation of NIR spectroscopy method. Reflection pattern of NIR spectra for finely sized sample (<0.5mm) and coarsely sized soil(<2mm) did not show much difference. The results showed that NIR spectroscopy and coarsely sized soil (<2mm) did not show much difference. The results showed that NIR spectroscopy could be used as a routine soil testing method in estimating OM, moisture, T-N in soil samples simultaneously.

근적외선 반사분광분석법에 의한 정육 및 그 구성성분의 반사 spectra에 관한 연구 (Studies on the Near Infrared Diffuse Reflection Spectroscopy for Meat Components)

  • 오은경
    • 한국식품과학회지
    • /
    • 제24권5호
    • /
    • pp.404-407
    • /
    • 1992
  • 이 연구의 목적은 식품성분의 분석을 위한 신속간편법으로 근적외선 반사 분광분석을 이용함에 있어 흡광도에 영향을 미치는 시료의 물리적, 화학적 요인을 규명하고자 한다. 온도를 달리한 정육시료를 근적외선 파장 범위인 $1100{\sim}2500\;nm$에서 흡광도를 측정한 결과 온도가 상승함에 따라 흡광도가 대체로 증가하였다. 시료의 세절시간이 길어질수록 흡광도는 감소하였다. 정육, 육단백질, 지방 및 수분의 근적외선 스펙트럼에서 나타난 흡수띠는 분자내의 C-H, N-H, O-H 및 C=O 결합의 overtone과 combination 진동에 의한 것으로 확인되었다. 정육 구성성분 중 육단백질의 흡광도가 가장 낮았으며 지방은 1700 nm와 2300 nm 부근에서 특징적인 ${\cdot}CH_2{\cdot}$ 흡수띠를 보였고 1450 nm와 1930 nm에서 물분자에 의한 강한 흡수띠가 나타났다. 결과적으로 정육의 근적외선 스펙트럼의 흡광도는 함유된 수분과 지방에 의한 영향을 많이 받는 것으로 사료된다.

  • PDF

근적외선 반사 박막 특성 연구 (Study on characteristics of thin films for reflection of near infrared light)

  • 정연길;박현식
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.4121-4124
    • /
    • 2015
  • 에너지 절감 유리창에서는 근적외선 차단 기능이 요구되고 있다. 본 연구에서는 근적외선 반사를 위한 광학 박막의 설계, 제작 및 광학적 특성이 연구 되었다. 광학 박막은 저굴절률막과 고굴절률막의 적층 박막 구조로 설계하였다. 설계구조에 따라 RF 스퍼터링 방법을 이용한 $SiO_2$$TiO_2$ 박막의 증착 실험이 수행되었고 파워에 따른 증착 조건 파라미터에 따라서 제작된 스퍼터링 박막의 특성이 분광타원기, 원자현미경, 분광기로 분석되었다. 적층박막 구조의 설계는 $SiO_2$$TiO_2$의 고굴절률 박막/저굴절률 박막/고굴절률 박막의 적층 구조로서 근적외선 차단 다층막이 설계되었고 시뮬레이션 되었다. 시뮬레이션 결과 파장대역 930nm에서 1682nm의 범위에서 반사율30%이상이 관찰되었다. 시뮬레이션 결과를 토대로 제작된 삼층 구조의 박막은 파장 대역이 930nm에서 1525nm범위 대역에서 반값 전폭의 반사율 33%이상을 구현할 수 있었다.

Effect of particle size and scanning cup type for near infrared reflection on the soil property measurement

  • Ryu, Kwan-Shig;Cho, Rae-Kwang;Park, Woo-Churl;Kim, Bok-Jin
    • Near Infrared Analysis
    • /
    • 제1권2호
    • /
    • pp.35-39
    • /
    • 2000
  • The purpose of this research was to find out suitable soil sample preparation and sample holding tools for NIR reflection radiation for estimating soil components. NIR reflectance was scanned at 2nm intervals from 1,100 to 2,500nm with an InfraAlyzer 500(Bran+Luebbe Co.). Coarse(2.0mm) and fine(0.5mm) soil sample and various sample holding tools were used to obtain mean diffuse reflection of the soil for the calibration and validation of the calibration set in estimating moisture, organic matter and total nitrogen of the soils. Multiple linear regression was used to obtain the best correlation of NIR spectroscopy method. Correlation of NIR spectroscopy method. Correlation of NIR spectra for finely and coarsely sized soil did not show much difference. The standard errors of prediction(SE) using different types of sample holding tools for organic matter, total nitrogen and soil moisture were better than 0.765, 0.041 and 0.63% respectively. From the results it can be concluded that NIR spectroscopy with flow type cell could be used as a fast routine testing method in quantitative determination of organic matter, total nitrogen and soil moisture.

근적외선 분광분석을 통한 산무수물경화 에폭시 시스템의 경화 동력학 (Cure Kinetics for the Acid Anhydride-cured Epoxy System Using a Near-infrared Reflection Spectroscopy)

  • 곽근호;박수진;이재락
    • 폴리머
    • /
    • 제24권1호
    • /
    • pp.65-71
    • /
    • 2000
  • 산무수물 경화 에폭시 수지의 잠재 특성 및 경화 동력학을 근적외선 분광분석법을 통해서 논의하였다. 잠재 특성과 경화 거동의 확인은 각기 다른 온도에서 에폭사이드와 수산기의 NIR reflectance를 측정함으로써 행해졌으며 반응 과정에서 4000~7100$cm^{-1}$ / 스펙트럼 범위의 주된 NIR 흡수피크의 기점, 위치 그리고 전이에 대한 포괄적인 분석이 이루어졌다. 반응의 정도는 에폭사이드의 함량과 경화 온도에 의존적인 4530$cm^{-1}$ /의 NIR 흡수 피크로부터 결정하였다.

  • PDF

가시광선 및 근적외선 스펙트럼을 이용한 도정비율 측정 (Measurement of Milling Ratio using the Visible and the Near-Infrared Rays Spectrum)

  • 이용국;이재현
    • Journal of Biosystems Engineering
    • /
    • 제24권3호
    • /
    • pp.259-266
    • /
    • 1999
  • This research was carried out to investigate the possibility of real time rice milling ratio measurement using the spectral reflection characteristics. In this study, various methods were compared such as \circled1 using the whiteness meter, \circled2 using the colorimeter, \circled3 using the Visible and the NIR reflection spectrum. The samples were milled in the domain of 84~96% by 0.5% interval classified by milling ratio. The NMG treatment method required about 20 minutes to determine the milled ratio and r2 was 0.0028 to 0.7959 that was very low. In case of whiteness meter, r2 was high but speed of measurement was 5 minutes that was very low. Measurement with the colorimeter required about 5 minutes and r2 was 0.60 to 0.85 that was low. The reflection spectrum were measured in the range of 400~2,500nm with 2nm interval and the MLR model with six-wavelength obtained from first derivative of spectra gave the best results(r2 = 0.967, SEP = 0.729%)

  • PDF

INLINE NEAR INFRARED (NIR) SPECTROSCOPY FOR PROCESS CONTROL IN POLYMER EXTRUSION

  • Rohe, Thomas;Koelle, Sabine;Becker, Wolfgang;Eisenreich, Norbert;Eyerer, Peter
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1082-1082
    • /
    • 2001
  • Extrusion is one of the most important processes in polymer industry. The characterization of the polymer melt during processing will improve this process noticeably, One possibility of characterizing the actual processed polymer melt is the inline near infrared (NIR) spectroscopy, With this method several polymer properties can be observed during processing, e.g. composition, moisture ormechanical properties of the melt. For this purpose probes for transmission and reflection measurements have been developed, withstanding the high temperatures and pressures appearing during extrusion process (tested up to 300$^{\circ}C$ and 10 ㎫). For the transmission system an optical bypass was developed to eliminate disturbing spectral influences and hence increase the long term stability, which is the prerequisite for an industrial application. Measurements in transmission and reflection produced comparable results (or blending processes, where the prediction error was less than 1%. An optimum RMSEP of only 0.24% was found for preprocessed polymer blends measured in transmission on a laboratory extruder. A transflection measurement allowed for the first time the recording of relevant NIR-spectra in the screw area of an extruder. The application to a (PE+PP) blending process delivered promising results. This new measurement mode allows the observation of the ongoing processes within the screw area, which is of maximum Interest for reactive extrusion processes. Due to economic reasons the calibration transfer between different extrusion systems is also of high importance. Investigations on simulated and real-world spectra showed that a calibration transfer is possible. A new method alternatively to the well-known direct standardization procedures was developed, which is based on an automatic data pretreatment. This procedure delivers comparable results for the calibration transfer. Overall this paper presents concepts, components and algorithms for the inline near infrared (NIR) spectroscopy for polymer extrusion, which allows the use of it in a real industrial extrusion process.

  • PDF

근적외분광분석법을 사용한 암브록솔 정제의 비파괴적 정량분석 (Nondestructive Quantification of Intact Ambroxol Tablet using Near-infrared Spectroscopy)

  • 임현량;우영아;김도형;김효진;강신정;최현철;최한곤
    • 약학회지
    • /
    • 제48권1호
    • /
    • pp.60-64
    • /
    • 2004
  • Near-infrared (NIR) spectroscopy was used to determine rapidly and nondestructively the content of ambroxol in intact ambroxol tablets containing 30 mg (12.5% m/m nominal concentration) by collecting NIR spectra in range 1100-1750 nm. The laboratory-made samples had 10.3∼15.9% m/m nominal ambroxol concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR) with autoscaling. Model validation was performed by randomly splitting the data set into calibration and validation data set (7 samples as a calibration data set and 5 samples as a validation data set). The developed NIR method gave results comparable to the known values of tablets in a laboratorial manufacturing Process, standard error of calibration (SEC) and standard error of prediction (SEP) being 0.49% and 0.49% m/m respectively. The method showed good accuracy and repeatability NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

Cloud-Type Classification by Two-Layered Fuzzy Logic

  • Kim, Kwang Baek
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제13권1호
    • /
    • pp.67-72
    • /
    • 2013
  • Cloud detection and analysis from satellite images has been a topic of research in many atmospheric and environmental studies; however, it still is a challenging task for many reasons. In this paper, we propose a new method for cloud-type classification using fuzzy logic. Knowing that visible-light images of clouds contain thickness related information, while infrared images haves height-related information, we propose a two-layered fuzzy logic based on the input source to provide us with a relatively clear-cut threshold in classification. Traditional noise-removal methods that use reflection/release characteristics of infrared images often produce false positive cloud areas, such as fog thereby it negatively affecting the classification accuracy. In this study, we used the color information from source images to extract the region of interest while avoiding false positives. The structure of fuzzy inference was also changed, because we utilized three types of source images: visible-light, infrared, and near-infrared images. When a cloud appears in both the visible-light image and the infrared image, the fuzzy membership function has a different form. Therefore we designed two sets of fuzzy inference rules and related classification rules. In our experiment, the proposed method was verified to be efficient and more accurate than the previous fuzzy logic attempt that used infrared image features.