• 제목/요약/키워드: natural wind

검색결과 862건 처리시간 0.03초

큰 개구부를 가진 단일구획 빌딩에서의 자연환기 모델의 개발 (Development of a Natural Ventilation Model in a Single Zone Building with Large Openings)

  • 조석호
    • 한국환경과학회지
    • /
    • 제27권6호
    • /
    • pp.359-369
    • /
    • 2018
  • A model has been developed to predict natural ventilation in a single zone building with large openings. This study first presents pressure-based equations on natural ventilation, that include the combined effect of wind and thermal buoyancy. Moreover, the concept of neutral pressure level(NPL) is introduced to consider the two-way flow through a large opening. The total pressure differences across the opening and the NPL are calculated, and nonlinear equations are solved to find the zonal pressure to satisfy mass conservation. For this analysis, an iterative technique of successively approximating the zonal pressure is used. The results of applying this study model to several simple cases are as follows. When there is no wind and only the stack effect is caused, a one-way flow occurs in both the top and bottom openings in the case of two openings of equal-area, and a one-way flow occurs in the top opening; however, a two-way flow occurs in the bottom opening in the case of two openings of unequal-area. When there is a wind effect, regardless of whether the outside air temperature is lower or higher than the indoor air temperature, air flows into the room through the bottom opening and out of the room through the top opening. As the wind velocity increases, the wind effect appears to be more influential than the stack effect owing to the temperature difference.

부유식 해상풍력발전기 타워의 초기 형상에 따른 공진 해석 (Resonance Analysis According to Initial Tower Design for Floating Offshore Wind Turbine)

  • 김준배;신현경
    • 풍력에너지저널
    • /
    • 제9권4호
    • /
    • pp.57-64
    • /
    • 2018
  • To maximize power generation and reduce the construction cost of a commercial utility-grade wind turbine, the size of the wind turbine should be large. The initial design of the 12 MW University of Ulsan(UOU) Floating Offshore Wind Turbine(FOWT) was carried out based on the 5 MW National Renewable Energy Laboratory(NREL) offshore wind turbine model. The existing 5 MW NREL offshore wind turbines have been expanded to 12 MW UOU FOWT using the geometric law of similarity and then redesigned for each factor. The resonance of the tower is the most important dynamic responses of a wind turbine, and it should be designed by avoiding resonance due to cyclic load during turbine operations. The natural frequency of the tower needs to avoid being within the frequency range corresponding to the rotational speed of the blades, 1P, and the blade passing frequency, 3P. To avoid resonance, vibration can be reduced by modifying the stiffness or mass. The direct expansion of the 5 MW wind turbine support structure caused a resonance problem with the tower of the 12 MW FOWT and the tower length and diameter was adjusted to avoid a match of the first natural frequency and 3P excitation of the tower.

춘천시 미세먼지 농도의 장기변동 추세 (Long-term Trend of Atmospheric Concentrations of Fine Particles in Chuncheon, Korea)

  • 양지혜;김성락;정진희;한영지
    • 한국대기환경학회지
    • /
    • 제27권5호
    • /
    • pp.494-503
    • /
    • 2011
  • Fine particles ($PM_{2.5}$) were collected and analyzed from December 2005 through December 2009 in Chuncheon, Korea to investigate the long-term trend of $PM_{2.5}$ concentrations. Also $PM_{10}$ concentrations were collected from Environmental Monitoring System operated by Ministry of Environment. Average concentrations of $PM_{2.5}$ and $PM_{10}$ were 30.5 and 58.2 ${\mu}g/m^3$, respectively. Both $PM_{2.5}$ and $PM_{10}$ were significantly affected by meteorological factors including wind speed, wind direction and precipitation. They generally decreased as wind speed increased (p=0.000), and increased when there was a prevailing westerly wind. Low concentrations of $PM_{2.5}$ were observed during rainy days while high concentrations were shown when fog, mist and/or haze occurred.

부유식 해상풍력발전기의 자세제어장치 개발을 위한 환형 실린더 탱크의 슬로싱 실험 (Experiment on Sloshing of Annular Cylindrical Tank for Development of Attitude Control Devices of Floating Offshore Wind Turbines)

  • 서명우;정의봉;조진래
    • 한국소음진동공학회논문집
    • /
    • 제23권1호
    • /
    • pp.25-33
    • /
    • 2013
  • The floating offshore wind turbines are usually exposed to the wave and wind excitations which are irregular and undirected. In this paper, the sloshing characteristics of annular cylindrical tank were experimentally investigated to reduce the structural dynamic motion of floating offshore wind turbine which is robust to the irregular change of excitation direction of wind and wave. The formula for the natural sloshing frequencies of this annular cylindrical tank was derived theoretically. In order to validate this formula, the shaking equipment was established and frequency response functions were measured. Two types of tank were considered. The first and second natural sloshing frequencies were investigated according to the depth of the water. It has been observed that between theoretical and experimental results shows a good agreement.

A Remote Sensed Data Combined Method for Sea Fog Detection

  • Heo, Ki-Young;Kim, Jae-Hwan;Shim, Jae-Seol;Ha, Kyung-Ja;Suh, Ae-Sook;Oh, Hyun-Mi;Min, Se-Yun
    • 대한원격탐사학회지
    • /
    • 제24권1호
    • /
    • pp.1-16
    • /
    • 2008
  • Steam and advection fogs are frequently observed in the Yellow Sea from March to July except for May. This study uses remote sensing (RS) data for the monitoring of sea fog. Meteorological data obtained from the Ieodo Ocean Research Station provided a valuable information for the occurrence of steam and advection fogs as a ground truth. The RS data used in this study were GOES-9, MTSAT-1R images and QuikSCAT wind data. A dual channel difference (DCD) approach using IR and shortwave IR channel of GOES-9 and MTSAT-1R satellites was applied to detect sea fog. The results showed that DCD, texture-related measurement and the weak wind condition are required to separate the sea fog from the low cloud. The QuikSCAT wind data was used to provide the wind speed criteria for a fog event. The laplacian computation was designed for a measurement of the homogeneity. A new combined method, which includes DCD, QuikSCAT wind speed and laplacian computation, was applied to the twelve cases with GOES-9 and MTSAT-1R. The threshold values for DCD, QuikSCAT wind speed and laplacian are -2.0 K, $8m\;s^{-1}$ and 0.1, respectively. The validation results showed that the new combined method slightly improves the detection of sea fog compared to DCD method: improvements of the new combined method are $5{\sim}6%$ increases in the Heidke skill score, 10% decreases in the probability of false detection, and $30{\sim}40%$ increases in the odd ratio.

Effects of frequency ratio on bridge aerodynamics determined by free-decay sectional model tests

  • Qin, X.R.;Kwok, K.C.S.;Fok, C.H.;Hitchcock, P.A.
    • Wind and Structures
    • /
    • 제12권5호
    • /
    • pp.413-424
    • /
    • 2009
  • A series of wind tunnel free-decay sectional model dynamic tests were conducted to examine the effects of torsional-to-vertical natural frequency ratio of 2DOF bridge dynamic systems on the aerodynamic and dynamic properties of bridge decks. The natural frequency ratios tested were around 2.2:1 and 1.2:1 respectively, with the fundamental vertical natural frequency of the system held constant for all the tests. Three 2.9 m long twin-deck bridge sectional models, with a zero, 16% (intermediate gap) and 35% (large gap) gap-to-width ratio, respectively, were tested to determine whether the effects of frequency ratio are dependent on bridge deck cross-section shapes. The results of wind tunnel tests suggest that for the model with a zero gap-width, a model to approximate a thin flat plate, the flutter derivatives, and consequently the aerodynamic forces, are relatively independent of the torsional-to-vertical frequency ratio for a relatively large range of reduced wind velocities, while for the models with an intermediate gap-width (around 16%) and a large gap-width (around 35%), some of the flutter derivatives, and therefore the aerodynamic forces, are evidently dependent on the frequency ratio for most of the tested reduced velocities. A comparison of the modal damping ratios also suggests that the torsional damping ratio is much more sensitive to the frequency ratio, especially for the two models with nonzero gap (16% and 35% gap-width). The test results clearly show that the effects of the frequency ratio on the flutter derivatives and the aerodynamic forces were dependent on the aerodynamic cross-section shape of the bridge deck.

피치제어기의 고유치 변화에 따른 풍력발전기의 성능 (Wind Turbine Performance for Eigen Value Change of Pitch Controller)

  • 김종화;문석준;신윤호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.337-343
    • /
    • 2012
  • NREL(National Renewable Energy Laboratory) Baseline controller conduct using method proposed RISO National Laboratory in Region 3. which designed the blade-pitch control system using a single degree-of-freedom model of the wind turbine. Idealized PID-Controlled rotor-speed error will respond as a second-order system with the natural frequency and damping ratio. RISO proposed specific natural frequency(=0.6 rad/s) and damping ratio(=0.7). If specific Eigen value apply to NREL 5 MW wind turbine, differ with pitch respond for simulation results of RISO report. Variation of specific eigen value investigate performance of NREL 5 MW wind turbine.

  • PDF

Assessment on Natural Frequencies of Structures using Field Measurement and FE Analysis

  • Kim, Do Hyun;Kim, Ji Young
    • 국제초고층학회논문집
    • /
    • 제3권4호
    • /
    • pp.305-310
    • /
    • 2014
  • Wind-induced responses of a structure are often evaluated through dynamic analysis, where measured wind forces obtained from a wind-tunnel test and dynamic properties obtained from a FE (Finite Element) model are utilized. However, the FE model generally shows considerable discrepancies in the estimation of natural frequencies compared to field measurements due to some assumptions and simplifications. In this paper, a calibration method that can improve the estimation of natural frequencies in the FE model is proposed, and specific cases are studied for its validity with comparison to the field measurement results.

현대의 풍력발전 기술 (Technique of Medern Wind Power Generation)

  • 김정환;김윤배;이영호
    • 한국유체기계학회 논문집
    • /
    • 제4권3호
    • /
    • pp.62-77
    • /
    • 2001
  • The modern wind turbines are widely used as important natural energy sources for the electric generation in western countries and some Asian nations. They are commercially matured and progressive and clear policy for the more development with higher technical purposes is maintained throughout the world. Modern wind turbines produce nearly 2000 kW output in their largest sizes and this trend increases up to more powerful power and ultimate utilization of wind energy favoured by clean natural energy. This article has the points of reviewing the states of the art of modern wind turbines with their present technical directions toward next generation version. Some descriptionsare given for easy understanding of the turbine components and related fluid mechanics concerned. The general outlines of policy taken over some countries are also introduced.

  • PDF

철도 선로 주변의 자연풍 특성에 관한 연구 (A study on the characteristics in the vicinity of the railway track)

  • 권혁빈;유원희;하강희;정명수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1152-1157
    • /
    • 2007
  • Anemometers to examine the characteristics of the natural wind in the vicinity of the railway track has been installed in two spots, one at the Cheon-Asan station of the Seoul-Busan high-speed line, and the other at the Daechon station of the Changhang conventional railway line in 2006 to examine the characteristics of the natural wind around the railway track to estimate the actual wind speed acting on the train and to develop the wind gust model consisting with the Korean climate condition. The measured data shows that the instant wind velocity frequently exceeds the velocity of train speed restriction, 20m/s, and the actual wind velocities measured in the vicinity of the track are larger than the that measured by the Korean Meteorological Administration(KMA) because the anemometers are installed on the highly-elevated bridges.

  • PDF