• Title/Summary/Keyword: national protocols

검색결과 824건 처리시간 0.024초

열광학적 분석 프로토콜에 의한 유기탄소와 원소탄소 측정값 비교 (Comparison of OC and EC Measurement Results Determined by Thermal-optical Analysis Protocols)

  • 김효선;정진상;이진홍;이상일
    • 한국대기환경학회지
    • /
    • 제31권5호
    • /
    • pp.449-460
    • /
    • 2015
  • Carbonaceous aerosol is generally classified into OC (organic carbon) and EC (elemental carbon) by thermal optical analysis. Both NIOSH (National institute of occupational safety and health) with high temperature (HighT) and IMPROVE-A (Interagency monitoring of protected visual environments) with low temperature (LowT) protocols are widely used. In this study, both protocols were applied for ambient $PM_{2.5}$ samples (Daejeon, Korea) in order to underpin differences in OC and EC measurements. An excellent agreement between NIOSH and IMPROVE-A protocol was observed for TC (total carbon). However, significant differences between OC and EC appeared and the differences were larger for EC than OC. The main differences between two protocols are temperature profile and charring correction method. For the same charring correction method, HighT_OC was 10% higher than LowT_ OC, while HighT_EC was 15% and 33% lower than LowT_EC for TOT (thermal-optical transmittance) and TOR (thermal-optical reflectance), respectively. This difference may be caused by the temperature of OC4 in He step and possibly difference in POC (pryorilized OC) formation. For the same temperature profile, OC by TOT was about 26% higher than that by TOR. In contrast, EC by TOT was about 50% lower than that by TOR. POC was also dependent on both temperature profile and the charring correction method, showing much distinctive differences for the charring correction method (i.e., POC by TOT to POC by TOR ratio is about 2). This difference might be caused by different characteristics between transmittance and reflectance for monitoring POC formation within filters. Results from this study showed that OC and EC depends on applied analysis protocol as shown other studies. Because of the nature of the thermal optical analysis, it may not be possible to have an absolute standard analysis protocol that is applicable for any ambient $PM_{2.5}$. Nevertheless, in order to provide consistent measurement results for scientists and policy makers, future studies should focus on developing a harmonized standard analysis protocol that is suitable for a specific air domain and minimizes variations in OC and EC measurement results. In addition, future elaborate studies are required to find and understand the causes of the differences.

웹 기반 고 에너지 방사선에 대한 흡수선량 교정 프로그램 개발 (Development of Web-based Dosimetry Calibration Program for High Energy Radiation)

  • 신동오;신동호;김성훈;박성용;서원섭;안희경;강진오;홍성언
    • 한국의학물리학회지:의학물리
    • /
    • 제16권3호
    • /
    • pp.116-124
    • /
    • 2005
  • 고 에너지 광자선과 전자선의 흡수선량 결정에 대한 표준측정법은 공기커마 교정인수를 바탕으로 한 방법이 널리 사용되고 있으나 복잡한 수식과 물리적인자의 불확실성 등으로 정확도 향상에 한계가 있다. 따라서 최근 국제원자력기구와 미국의학물리학회에서 물 흡수선량을 기반으로 표준측정법을 개발하였다. 본 연구는 국제원자력기구의 IAEA TRS-398 과 미국의학물리학회의 AAPM 7e-51 물 흡수선량 표준측정법에 대한 인터넷을 기반으로 하는 선량교정 프로그램을 개발하였다. 이 프로그램은 인터넷 온라인상에서 사용할 수 있도록 C$\#$ 언어를 사용하여 각각의 표준측정법의 절차에 따라 사용자의 편의를 고려하여 개발하였다. 사용자는 인터넷을 통해 기준점에서의 두 가지 절차서에 따른 물 흡수선량을 비교할 수 있으며, 국내 각 기관에서 수행된 선량교정의 추세를 이해하고 보다 쉽게 관리할 수 있게 하였다. 웹 기반 데이터베이스를 이용하여 차후 국내 실정에 적합한 물 흡수선량 표준에 기반을 둔 표준측정법을 개발하는데 기여할 것으로 기대된다

  • PDF

Use of Cylindrical Chambers as Substitutes for Parallel-Plate Chambers in Low-Energy Electron Dosimetry

  • Chun, Minsoo;An, Hyun Joon;Kang, Seong-Hee;Cho, Jin Dong;Park, Jong Min;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.16-22
    • /
    • 2018
  • Current dosimetry protocols recommend the use of parallel-plate chambers in electron dosimetry because the electron fluence perturbation can be effectively minimized. However, substitutable methods to calibrate and measure the electron output and energy with the widely used cylindrical chamber should be developed in case a parallel-plate chamber is unavailable. In this study, we measured the correction factors and absolute dose-to-water of electrons with energies of 4, 6, 9, 12, 16, and 20 MeV using Farmer-type and Roos chambers by varying the dose rates according to the AAPM TG-51 protocol. The ion recombination factor and absolute dose were found to be varied across the chamber types, energy, and dose rate, and these phenomena were remarkable at a low energy (4 MeV), which was in good agreement with literature. While the ion recombination factor showed a difference across chamber types of less than 0.4%, the absolute dose differences between them were largest at 4 MeV at approximately 1.5%. We therefore found that the absolute dose with respect to the dose rate was strongly influenced by ion-collection efficiency. Although more rigorous validation with other types of chambers and protocols should be performed, the outcome of the study shows the feasibility of replacing the parallel-plate chamber with the cylindrical chamber in electron dosimetry.

COVID-19 진단을 위한 CT 검사: 프로토콜, 방사선량에 대한 체계적 문헌고찰 및 진단을 위한 CT 검사량 (CT Examinations for COVID-19: A Systematic Review of Protocols, Radiation Dose, and Numbers Needed to Diagnose and Predict)

  • 이종혁;홍현숙;김형진;이창현;구진모;윤순호
    • 대한영상의학회지
    • /
    • 제82권6호
    • /
    • pp.1505-1523
    • /
    • 2021
  • 목적 Coronavirus disease 2019 (이하 COVID-19) 폐렴에서 CT를 일차 진단 검사로 사용하고자 하는 논의가 있지만, 대규모 인구에게 CT 검사를 적용했을 때의 상황을 고찰한 연구는 없었다. 본 연구에서는 COVID-19 폐렴을 다룬 연구들에서 CT 프로토콜과 방사선량을 분석하고, CT 검사가 일차 진단 검사법으로 사용될 때 필요한 CT 검사량에 대해 알아보고자 한다. 대상과 방법 본 연구는 9개의 인용도가 높은 영상의학과 저널에서 COVID-19 폐렴의 CT 기반 진단을 다룬 문헌들을 검색하였다. 먼저, 연구에서 제시된 CT 프로토콜, 방사선량을 조사하여, 이를 해당 국가의 diagnostic reference level과 비교하였다. 추가로, COVID-19에 대한 CT 민감도 94%, 특이도 37%를 적용하여, 우한시와 뉴욕, 이탈리아의 초기 COVID-19 outbreak에서 polymerase chain reaction (이하 PCR) 검사 양성률에 기반한 number needed to diagnose (이하 NND)와 number needed to predict (이하 NNP)를 계산하였다. 결과 총 86개의 연구가 검색되었고, 그중 CT 프로토콜은 81개의 연구에서(94.2%), 방사선량은 17개의 연구에서(19.8%) 보고되었다. 저선량 흉부 CT는 표준선량 흉부 CT보다 2배 많은 연구에서 활용되었다(39.5% vs. 18.6%). 방사선량을 보고한 17개의 연구들 중, 15개의 연구에서 방사선량은 해당 국가의 diagnostic reference level 수치보다 낮았다(88.2%). COVID-19에 대한 CT 민감도 94%, 특이도 37%를 적용하였을 때, NND는 3.2회 CT scans으로 나타났다. 한편, PCR 검사 양성률 50%, 25%, 10%, 5%에서의 한 명의 COVID-19 환자를 진단 위한 CT 검사량을 나타내는 NNP는 각각 2.2, 3.6, 8.0, 15.5회의 CT scans로 나타났다. 우한 시에서는 최종 17365명의 COVID-19 환자를 진단하기 위하여 약 35418명에서(PCR 검사 양성률 58%) 44840명(PCR 검사 양성률 38%)의 사람들이 CT 검사를 받은 것으로 나타났다. 뉴욕시와 이탈리아의 초기 COVID-19 유행 10주간, PCR 검사 양성률에 따라 일 CT 검사량이 최대 5.4, 10.9배까지 변화하였다. 결론 CT를 COVID-19에 대한 일차적인 진단검사로 사용할 경우, PCR 검사 양성률에 따라 CT 검사량은 변동량이 크고, 이는 추후 판데믹 상황에서 고려되어야 할 것이다.

Development of pig welfare assessment protocol integrating animal-, environment-, and management-based measures

  • Renggaman, Anriansyah;Choi, Hong L;Sudiarto, Sartika IA;Alasaarela, Laura;Nam, Ok S
    • Journal of Animal Science and Technology
    • /
    • 제57권1호
    • /
    • pp.1.1-1.11
    • /
    • 2015
  • Background: Due to increased interest in animal welfare, there is now a need for a comprehensive assessment protocol to be used in intensive pig farming systems. There are two current welfare assessment protocols for pigs: Welfare Quality$^{(R)}$ Assessment Protocols (applicable in the Europe Union), that mostly focuses on animal-based measures, and the Swine Welfare Assurance Program (applicable in the United States), that mostly focuses on management- and environment-based measures. In certain cases, however, animal-based measures might not be adequate for properly assessing pig welfare status. Similarly, welfare assessment that relies only on environment- and management-based measures might not represent the actual welfare status of pigs. Therefore, the objective of this paper was to develop a new welfare protocol by integrating animal-, environment-, and management-based measures. The background for selection of certain welfare criteria and modification of the scoring systems from existing welfare assessment protocols are described. Methods: The developed pig welfare assessment protocol consists of 17 criteria that are related to four main principles of welfare (good feeding, good housing, good health, and appropriate behavior). Good feeding, good housing, and good health were assessed using a 3-point scale: 0 (good welfare), 1 (moderate welfare), and 2 (poor welfare). In certain cases, only a 2-point scale was used: 0 (certain condition is present) or 2 (certain condition is absent). Appropriate behavior was assessed by scan sampling of positive and negative social behaviors based on qualitative behavior assessment and human-animal relationship tests. Results: Modification of the body condition score into a 3-point scale revealed pigs with a moderate body condition (score 1). Moreover, additional criteria such as feed quality confirmed that farms had moderate (score 1) or poor feed quality (score 2), especially those farms located in a high relative humidity region. Conclusions: The developed protocol can be utilized to assess welfare status in an intensive pig farming system. Although further improvements are still needed, this study is a first step in developing a pig welfare assessment protocol that combines animal-, environment-, and management-based measures.

Pharmacokinetic Compartment Modeling을 이용한 나선식 CT에서의 간암-간 대조 곡선의 Simulation (Simulation of lesion-to-liver contrast difference curves in Dynamic Hepatic CT with Pharmacokinetic Compartment Modeling)

  • S.J. Kim;K.H. Lee;J.H. Kim;J.K. Han;B.G. Min
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권2호
    • /
    • pp.173-182
    • /
    • 1999
  • 조영 증강제를 이용한 나선식 CT는 간 질환을 진단하는데 있어 중요한 역할을 하고있음에도 불구하고 진단의 효율을 최적화하는 프로토콜은 명확하게 알려져 있지 않다. 따라서 나선식 CT에서의 간암-간 대조 곡선을 모의 실험(simulation) 하여 다양한 요소들이 시간-조영 곡선에 어떻게 영향을 미치는지 파악하고, 또한 CT 검사 전에 모의 실험을 하여 이론적으로 최적의 스캔을 할 수 있도록 하기 위하여 약동학(pharmacokinetics)에 기초한 compartment model을 구성하였다. 간암, 간, 대동맥 및 간문맥 등을 각 구획(compartment)으로 설정하여 각 구획에서의 미분방정식을 얻은 후 적분하여 Hounsfield unfit 값을 조영제 주입 후 시간의 함수로 얻었으며 각 구획의 시간-조영 곡선을 출력하였다. 구현한 프로그램에서는 간암의 크기 및 종양 혈관의 분포 등과 같은 간암의 성질, 간경화의 정도에 따른 간 혈관 공급의 양상 및 조영제의 부피, 농도, 주입 속도 등의 조영제 주입 방법, 환자의 몸무게, 키 등의 환자의 신체 계수, 그리고 심박출량 등의 환자의 혈역학적 계수 등을 입력 받아 간암을 비롯한 각 구획의 시간-조영 곡선 및 간-간암 대조 곡선을 출력할 수 있도록 하였다. 모델링을 통해 얻은 조영 증강 곡선은 같은 환경하에서 얻은 24명의 환자 데이터와 비교하여 유사한 결과를 얻을 수 있었으며, 조영 증강제 주입 방법의 변화가 간암-간 대조 곡선에 미치는 영향을 비교할 수 있었다.

  • PDF

Signcryption을 이용한 부정자 추적 프로토콜 (Traitor Traceable Protocols using Modified Signcryption)

  • 신성한;박지환;허영
    • 한국멀티미디어학회:학술대회논문집
    • /
    • 한국멀티미디어학회 2001년도 춘계학술발표논문집
    • /
    • pp.471-476
    • /
    • 2001
  • 본 논문에서는 Y. Watanabe et al.에 의해 제안된 서명부가문서를 이용한 부정자 추적기법을 분석하여 PKI(Public Key Infrastructure)기반에서 구현 가능하도록 프로토콜을 재구성하고, 그 안전성을 분석한다. 그리고 변형된 Signcryption을 이용한 프로토콜을 제안하여 기존의 유사 프로토콜과 비교·분석하여 제안된 프로토콜이 더욱 효율적임을 보인다.

  • PDF

능동형 텔레매트릭스를 위한 IEEE 1451 기반 ZigBee 스마트 센서 시스템의 구현 (Implementation of IEEE 1451 based ZigBee Smart Sensor System for Active Telemetries)

  • 이석;송영훈;박지훈;김만호;이경창
    • 한국정밀공학회지
    • /
    • 제28권2호
    • /
    • pp.176-184
    • /
    • 2011
  • As modern megalopolises become more complex and huge, convenience and safety of citizens are main components for a welfare state. In order to make safe society, telemetrics technology, which remotely measures the information of target system using electronic devices, is an essential component. In general, telemetrics technology consists of USN (ubiquitous sensor network) based on a wireless network, smart sensor, and SoC (system on chip). In the smart sensor technology, the following two problems should be overcome. Firstly, because it is very difficult for transducer manufacturers to develop smart sensors that support all the existing network protocols, the smart sensor must be independent of the type of networking protocols. Secondly, smart sensors should be modular so that a faulty sensor element can be replaced without replacing healthy communication element. To solve these problems, this paper investigates the feasibility of an IEEE 1451 based ZigBee smart sensor system. More specifically, a smart sensor for large network coverage has been developed using ZigBee for active telemetrics.

돼지 배아줄기세포 확립을 위한 최적의 유도시기 (Optimal Derivation Timing for Establishment of Porcine Embryonic Stem Cells)

  • 김은혜;정승아;윤준철;전유별;현상환
    • 한국수정란이식학회지
    • /
    • 제28권1호
    • /
    • pp.1-6
    • /
    • 2013
  • A lot of works have been dedicated to clarify the reasons why the establishment of embryonic stem cells (ESCs) from pig is more difficult than that from mouse and human. Several concomitant factors such as culture condition including feeder layer, sensitivity of cell to cell contact, definitive markers of pluripotency for evaluation of the validity and optimal timing of derivation have been suggested as the disturbing factors in the establishment of porcine ESCs Traditionally, attempts to derive stem cells from porcine embryos have depend on protocols established for mouse ESCs using inner cell mass (ICM) for the isolation and culture. And more recently, protocols used for primate ESCs were also applied. However, there is no report for the establishment of porcine ESCs. Indeed, ungulate species including pigs have crucial developmental differences unlike rodents and primates. Here we will review recent studies about issues for establishment of porcine ESCs and discuss the promise and strategies focusing on the timing for derivation and pluripotent state of porcine ESCs.