• Title/Summary/Keyword: nail polish

Search Result 20, Processing Time 0.023 seconds

Estimation of the Formaldehyde Concentration of Subterranean Shopping Centers according to their Spatial Configuration and Renovation (지하도상가의 리모델링 및 공간 특성에 따른 포름알데히드 농도 분석)

  • Sim, Kyung-Sub;Kim, Hyunsoo;Yu, Seulgi;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.25 no.3
    • /
    • pp.182-187
    • /
    • 2014
  • Underground shopping center has become a important commercial facility due to their good accessibility to the public transport. However, underground shopping center has high risk of air contaminants emission like formaldehyde and lowered indoor air quality. In this study, formaldehyde concentration of the underground shopping center was estimated according to the renovation and characteristics of space. It was found that newly renovated underground shopping center has low formaldehyde concentration. In case of closed entrance type, the formaldehyde concentration was 320 % higher than open type. Formaldehyde concentration was varied by product type and especially, high formaldehyde concentration was measured near the stores selling nail polish and cosmetics. It is important to apply appropriate ventilation system according to characteristics of space.

  • PDF

The Effectiveness of Obturating Techniques in Sealing Isthmuses (근관충전방법에 따른 근단부 isthmus의 폐쇄효과에 관한 비교연구)

  • Ho-Keel Hwang;Young-Guen Shin
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.6
    • /
    • pp.499-506
    • /
    • 2001
  • 불완전하게 충전되거나 충전이 되지않은 isthmus는 다근치에 있어서 근관치료의 높은 실패율을 나타낸다 따라서 본 연구의 목적은 isthmus를 갖는 근관을 골라 근관계의 기구조작을 시행하고 여러 가지 근관충전 방법을 이용하여 근관을 충전한 다음 근단부 형성시 적절한 파일의 크기와 치근단부의 밀폐효과를 각 부위별로 비교평가 해보고자 하는 것이다. Isthmus를 갖는 66개의 발거한 치아를 대상으로 기구조작을 통하여 근관확대를 완성하고 무작위로 각각 20개씩 3군으로 분류한 다음 아래와 같은 방법으로 근관을 충전하였다. : A군 측방가압충전법으로 충전한 군, B군 Continuous wave 충전법으로 충전한 군, C군 MicroSeal$^{TM}$을 이용하여 충전한 군. 나머지 6개의 치아는 3개씩 양성대조군과 음성대조군으로 정하였으며 기구조작 후 근관은 충전하지 않은 채로 두었다. 대조군을 제외한 모든 군은 각각 제조회사의 지시에 따라 근관충전한 후 각 시편의 치근단부 2mm를 제외하고 나머지 부위는 두겹의 nail polish를 발라주었으며 2% methylene blue용액에 침잠시켰다 일주일 후 꺼내어 흐르는 물에 깨끗이 세척한 다음 치근단 부위에서부터 1mm씩 잘라가면서 20배의 배율에서 염색액의 침투정도를 평가하였다. 염색액의 침투정도는 다음과 같이 평가되었다. A군과 B군에서는 많은 수의 시편에서 4mm 이상의 절단면에 염색액의 침투를 보인 반면 C군에서는 단지 3mm절단면에서 총 20개 중 3개의 시편에서 염색액의 침투를 보였을 뿐 그 이상의 절단면에서는 염색액의 침투를 보이지 않았다. 뿐만 아니라 isthmus를 갖는 제2형 근관계의 근단부 형성은 40번 크기보다는 큰 MAF가 요구되는 것으로 나타났다. 이러한 결과를 비추어볼 때 isthmus를 갖는 다근치에서 근관충전시 적어도 40번 이상의 MAF로 근단부 형성을 한 후, 열가소성 Continuous wave 충전법과 MicroSeal$^{TM}$을 이용한 근관충전법이 기존의 측방가압충전법 보다는 효과적인 것으로 나타났다.

  • PDF

A Research on the Education, Knowledge and Management levels about Sanitation at Window Bakery in the Metropolitan Area (수도권 지역 윈도우 베이커리의 위생 교육, 위생 지식과 위생 관리 현황에 관한 연구)

  • Hwang, Yoon-Kyung;Woo, In-Ae;Lee, Hee-Tae
    • Culinary science and hospitality research
    • /
    • v.18 no.4
    • /
    • pp.148-165
    • /
    • 2012
  • The purpose of this study is to investigate window bakery employees' knowledge levels and performance in food sanitation. The questionnaire consists of education, knowledge and management levels for food sanitation. A total of 300 copies of questionnaire were distributed to window bakery employees, and 295 copies were used for the study among them. In the knowledge analysis of food sanitation, it had the highest percentage of correct answers for 'Clip fingernails short and do not use nail polish,' but the lowest rank for 'Foodborne disease breaks out mainly in summer time.' In sanitary management performance, 'Clip fingernails short and do not use nail polish'(4.67) and 'Wash hands after using toilet'(4.67) items showed high scores, but 'Have and use hand washer'(3.12) showed the lowest score as a result of knowledge analysis. The sanitary knowledge by job title showed that the scores of general managers were generally lower than those of others. The employees who had working duration less than 1 year had a high score in sanitary knowledge levels. The more the education of sanitation, the better the knowledge of sanitation. In sanitary management performance levels, the scores were high in personal hygiene, ingredients & preparation hygiene, facility & workplace hygiene in order. The scores of sanitary management performance levels were low for the employees who had less than 1 year working duration. The employees who had no sanitary training showed the low knowledge and sanitary management practice levels(p<0.05). The analysis of each question about sanitary management performance levels by age, job titles, frequency of sanitary education, and checklists revealed that the employees who had no sanitary training or no checklist showed the low sanitary management performance levels overall.

  • PDF

IN VITRO STUDY ON APICAL SEAL AND SEM MORPHOLOGY IN CANALS FILLED WITH RESIN-BASED ROOT CANAL SEALER AND SELF-ETCHING PRIMER (SELF-ETCHING PRIMER와 레진계 근관 SEALER 사용시 근관벽의 형태와 치근단 근관밀폐에 대한 실험적 연구)

  • Kang, Sam-Hee;Park, Dong-Sung;You, Heyon-Mee;Oh, Tae-Seok
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.543-549
    • /
    • 2000
  • Gutta-percha와 근관sealer를 사용한 근관 충전은 가장 많이 이용되고 성공률이 높은 방법이지만, 현재 사용되는 모든 근관sealer는 미세누출을 나타낸다. 따라서 더 효과적인 근관 폐쇄를 이루기 위한 재료 및 방법들이 연구되어왔다. 이중 상아질 접착제는 근관 충전재와 함께 사용되어 미세누출을 감소시키지만, 근관 내에 사용하기에 술식이 복잡하고 기술이 요구된다. 본 연구의 목적은 gutta-percha와 레진계 근관 sealer로 충전한 근관에서 self-etching primer를 미리 도포한 경우와 도포하지 않은 경우의 치근단 미세누출을 비교하고, self-etching primer를 도포함에 있어 근관 내에 적용하는 방법에 따른 미세누출을 비교하는 것이다. 또한 근관sealer와 상아질 계면을 주사전자현미경으로 관찰하여, 이 결과를 미세누출과 관련시켜보고자 하였다. 36개의 발거된 사람의 단근치에서 치관부를 절단, 제거하고 ProFile로 근관 형성한 후, 무작위로 선택하여 4개의 군으로 분류하였다. 1군에서는 주사기와 30게이지 주사 바늘로 self-etching primer를 근관 내에 적용하였고, 2군에서는 self-etching primer를 paper point에 적셔 근관 내에 적용하였다. 3군에서는 self-etching primer를 적용하지 않았다. 1, 2, 3군의 치아를 gutta-percha와 AH26 sealer를 사용하여 continuous wave 충전법으로 충전한 후 치근단공 주위 3mm를 제외한 치근변에 nail polish를 2회 도포하였고, 4군(음성 대조군)은 치근면 전체에 도포하였다. 1군과 2군에서 각각 2개의 치아는 주사전자현미경적 관찰을 위해 준비하였다. 모든 치아를 Methylene Blue 수용액에 48시간동안 침적, 수세한 후 치아 장축에 평행하게 양분하여 10배의 실물확대현미경 하에서 치근단 색소 침투를 관찰하였다. Self-etching primer를 도포한 군과 도포하지 않은 군 사이에는 평균 미세누출량에 유의한 차이가 없었다. 주사 바늘로 적용한 군과 paper point로 적용한 군 사이에도 평균 미세누출량에 유의한 차이가 없었다. 상아질과 근관 sealer계면의 주사전자현미경 관찰 결과 일부분에서 긴밀한 접착 관계를 나타내었고, 다른 부분에서는 간극을 나타내었다.

  • PDF

THE EFFECT OF SANDWICH TECHNIQUE USING FLOWABLE COMPOSITE RESIN BASE ON THE MICROLEAKAGEIN CLASS II CAVITIES OF MOLAR (구치부 제2급 와동에서 고흐름성 복합레진을 이용한 적층 충전술식의 미세누출에 미치는 영향)

  • Lee, Kang;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.502-514
    • /
    • 2002
  • The aim of this study was to evaluate the marginal adaptation of direct class II sandwich restoration with packable composites(P-60), resin modified glass ionomer cement(Fuji-II LC), flowable compomer(Dyract Flow), flowable composites(Filtek Flow) in comparison with total bond restorations. In addition, for sandwich restorations, influence of different sandwich techniques was also evaluated. Large butt-joint box typed class II cavites with cervical margins 1mm below the cemento-enamel junction were cut into 70 extracted human molars. The cavities(7 groups, n=10) were filled using a closed/open sandwich restoration or total bond restoration technique with materials according to the manufacturer's recommandation using the single-component bonding agent for each system. Teeth were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 30-second dwell time. The teeth were then coated with nail polish 1mm short of the restoration, placed in a 2% methylene blue for 24 hours, and sectioned with diamond wheel. Sections were examined with a stereoscope to determine the extent of microleakage. Dentine /Cementum margins were analyzed for microleakage on scale of 0(no leakage) to 4(entire axial wall) and interface between materials, on scale of 0(no leakage) to 3(axial wall). Results were evaluated with Kruskal Wallis Test, corrected for ties, to determine whether there were statistically significant differences among the seven groups. Pairs of groups were analyzed using the Student-Newman-Keuls Method and Dunn s Method. The results were as follows : 1. All groups showed some micoleakage in cervical portion. But there were no microleakage in interface between materials. 2. Closed sandwich restorations with Fuji-II LC and Filtek Flow had significantly lower leakage rating than total restorations with only P-60. However, open sandwich restorations with Dyract Flow showed significantly higher (P<0.05) 3. Closed sandwich restorations had significantly lower leakage rating than total restorations. However open sandwich restoration s showed significantly higher (P<0.05). 4. Sandwich restorations with Fuji-II LC were iou$.$or leakage than only P-60. Filtek Flow, Dyract Flow. But there were no statistically differences among the materials. From the results above, it could be concluded, closed sandwich restorations was effective in reducing microleakage of class II restorations. The best results showing the least microleakage were for the closed sandwich technique with Fuji-II LC and Filtek Flow.

A Study on the Noxious Materials in the Waste Shipped into Solid Recovered Fuel(SRF) Facilities and Their Influence (고형연료(SRF)시설로 반입되는 폐기물의 영향 및 유해성물질 등에 관한 연구)

  • Lee, Seung-Won;Kim, Sang-Hun;Lee, Sang-Seok;Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.27 no.2
    • /
    • pp.91-97
    • /
    • 2018
  • This study carried out first a component survey on the domestic waste shipped into a waste disposal facility in B city, and then heavy metal analysis of each component according to the SRF standards. Based on this, this study explored the problems with domestic waste and measures to improve them. The results are as follows. The result of the survey of physical components show that paper accounted for the largest proportion with 20.5 %~59.9 %, metals (including batteries) among incombustibles accounted for 0.0~8.3 %, other inorganic substances, glass and ceramics accounted for 0.0~43.7 % and 0.0 %~19.6 % respectively. However, the proportion of coated viny and plastics, which have high lead and cadmium content, was rather high with 2.9 %~30.9 %. This suggests the possibility that actual concentration of lead and cadmium within SRF is likely to be higher. Among the 15 components contained in the waste brought into the waste disposal facility, 10 components (food waste, textiles, vinyl, plastics, wood, rubber and leather, paper, metals, electronic substrates, and nail polish) were analyzed according to assay samples (approximately 0.1 g and 0.3 g). The result of analysis shows that the amount of Cd and Pb detected in coated vinyl for 0.109 g of assay sample was 98.6 mg/kg and 20.6 mg/kg respectively; 117.0 mg/kg and 29.0 mg/kg respectively for 0.313 g of assay sample. This is high contents exceeding the Cd standard. As for wooden component, the amount of Pb was 480.0 mg/kg for 0.3 g of assay sample. This suggests that there always exists the possibility of exceeding the exposure level of heavy metals (Cd and Pb) in SRF as long as coated wood and vinyl plastics with high contents of Pb and Cd are shipped into the waste disposal facility; and the local government and the residents need to work hard to improve the situation including development of the machine to sort electronic substrates and batteries for separate collection of the waste of coated vinyl and plastics within domestic waste.

Quality Characteristics of Korean Domestic Commercial Rosé Wines (국산 시판 로제 와인의 품질 특성)

  • Park, Jung-Mi;Park, Hyejin;Jeong, Changwon;Choi, Wonil;Kim, Sidong;Yoon, Hyang-Sik
    • The Korean Journal of Food And Nutrition
    • /
    • v.30 no.5
    • /
    • pp.889-899
    • /
    • 2017
  • To investigate the quality characteristics of domestic $ros{\acute{e}}$ wines marketed in Korea, 11 kinds of wines were purchased at the Korea Wine Festival in 2016. The color, physiological activity, aroma component and sensory evaluations were conducted. The hue value of $ros{\acute{e}}$ wines ranged from 0.592 to 1.990, with the Ro7 of Delaware having the highest value. The brightness of $ros{\acute{e}}$ wines ranged from 42.96 to 94.99, the redness from 3.20 to 59.37, and the yellowness from 8.43 to 24.83. Of the 11 $ros{\acute{e}}$ wines evaluated, 1 was a dry wine and 10 were sweet wines. The average sugar content of the sweet wines was 73.89 mg/mL. Among the organic acid contents, malic acid ranged from 0.214 to 2.903 mg/mL, and lactic acid content ranged from 0 to 3.423 mg/mL. Malolactic fermentation differed, depending on the source. The total polyphenol content of $ros{\acute{e}}$ wines ranged from 50.55 to 99.55 mg%, the anthocyanin content was 2.12 to 213.30 mg/L, and the DPPH radical scavenging activity of $ros{\acute{e}}$ wines was between 73.75 to 90.41%. A total of 41 volatile components were detected, including 7 alcohols, 22 esters, 4 terpenes, 3 acids and 5 other compounds. Of these, 9 compounds had odor activity value(OAV) greater than 1; these were identified as 1-propanol (alcohol, pungent), 3-methyl-1-butanol (harsh, nail polish), ethyl butanoate (strawberry, lactic), isopentyl acetate (fresh, banana), ethyl hexanoate (green apple, fruity), ethyl octanoate (pineapple, pear, floral), ethyl decanoate (fruity, fatty, pleasant), linalool (flower, lavender) and limonene (lemone, orange). As a result of the sensory evaluation, the Ro5 wine made from Campbell Early grape, and having a good color, flavor and taste, was the most preferred.

MICROLEAKAGE OF MICROFILL AND FLOWABLE COMPOSITE RESINS IN CLASS V CAVITY AFTER LOAD CYCLING (Flowable 및 microfill 복합레진으로 충전된 제 5급와동에서 load cycling 전,후의 미세변연누출 비교)

  • Kang, Suk-Ho;Kim, Oh-Young;Oh, Myung-Hwan;Cho, Byeong-Hoon;Um, Chung-Moon;Kwon, Hyuk-Choon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.142-149
    • /
    • 2002
  • Low-viscosity composite resins may produce better sealed margins than stiffer compositions (KempScholte and Davidson, 1988: Crim, 1989). Plowable composites have been recommended for use in Class V cavities but it is also controversial because of its high rates of shrinkage. On the other hand, in the study comparing elastic moduli and leakage, the microfill had the least leakage (Rundle et at. 1997) Furthermore, in the 1996 survey of the Reality Editorial Team, microfills were the clear choice for abfraction lesions. The purpose of this study was to evaluate the microleakage of 6 compostite resins (2 hybrids, 2 microfills, and 2 flowable composites) with and without load cycling. Notch-shaped Class V cavities were prepared on buccal surface of 180 extracted human upper premolars on cementum margin. The teeth were randomly divided into non-load cycling group (group 1) and load cycling group (group 2) of 90 teeth each. The experimental teeth of each group were randomly divided into 6 subgroups of 15 samples. All preparations were etched, and Single bond was applied. Preparations were restored with the following materials (n=15) : hybrid composite resin [Z250(3M Dental Products Inc. St. Paul, USA), Denfil(Vericom, Ahnyang, Korea)], microfill [Heliomolar RO(Vivadent, Schaan, Liechtenstein), Micronew(Bisco Inc. Schaumburg, IL, USA)], and flowable composite[AeliteFlo(Bisco Inc. Schaumburg, IL, USA), Revolution(Kerr Corp. Orange, CA, USA)]. Teeth of group 2 were subjected to occlusal load (100N for 50,000 cycles) using chewing simulator(MTS 858 Mini Bionix II system, MTS Systems Corp. Minn. USA). All samples were coated with nail polish 1mm short of the restoration, placed in 2% methylene blue for 24 hours, and sectioned with a diamond wheel. Enamel and dentin/cementum margins were analyzed for microleakage on a sclale of 0 (no leakage) to 3 (3/3 of wall). Results were statistically analyzed by Kruscal-Wallis One way analysis, Mann-Whitney U-test, and Student-Newmann-Keuls method. (p = 0.05) Results : 1. There was significantly less microleage in enamel margins than dentinal margins of all groups (p<0.05) 2. There was no significant between six composite resin in enamel margin of group 1. 3. In dentin margin of group 1, flowable composite had more microleakage than others but not of significant differences. 4. there was no significant difference between six composite resin in enamel margin of group 2. 5. In dentin margin of group 2, the microleakage were R>A =H=M>D>Z. But there was no significant differences. 6. In enamel margins, load cycling did not affect the marginal microleakage in significant degree. 7. In enamel margins, load cycling did affect the marginal microleakage only in Revolution. (p<0.05).

INFLUENCES OF APICOECTOMY AND RETROGRADE CAVITY PREPARATION METHODS ON THE APICAL LEAKAGE (치근단절제 및 역충전와동 형성방법이 치근단누출에 미치는 영향)

  • Yang, Jeong-Ok;Kim, Sung-Kyo;Kwon, Tae-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.537-549
    • /
    • 1998
  • The purpose of this study was to evaluate the influence of root resection and retrograde cavity preparation methods on the apical leakage in endodontic surgery. To investigate the effect of various root resection and retrograde cavity preparation methods on the apical leakage, 71 roots of extracted human maxillary anterior teeth and 44 mesiobuccal roots of extracted human maxillary first molars were used. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. Three millimeters of each root was resected at a 45 degree angle or perpendicular to the long axis of the tooth according to the groups. Retrograde cavities were prepared with ultrasonic instruments or a slow-speed round bur, and occlusal access cavities were filled with zinc oxide eugenol cement. Three coats of clear nail polish were placed on the lateral and coronal surfaces of the specimens except the apical cut one millimeter. All the specimens were immerged in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using two-way ANOVA and Duncans Multiple Range Test. The results were as follows: 1. No statistically significant difference was observed between ultrasonic retrograde cavity preparation method and slow-speed round bur technique, without apical bevel (p>0.05). 2. Ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, with bevel (p<0.0001). 3. No statistically significant difference was found between beveled resected root surface and non-beveled resected root surface, with ultrasonic technique (p>0.05). 4. Non-beveled resected root surface showed significantly less apical leakage than beveled resected root surface, with slow-speed round bur technique (p<0.0001). 5. No statistically significant difference in apical leakage was found between the group of retrograde cavity prepared parallel to the long axis of the tooth and the group of one prepared perpendicular to the long axis of the tooth (p>0.05). 6. Regarding isthmus preparation, ultrasonic retrograde preparation method showed significantly less apical leakage than slow-speed round bur technique, in the mesiobuccal root of maxillary molar, without bevel (p<0.0001).

  • PDF

INFLUENCES OF DRY METHODS OF RETROCAVITY ON THE APICAL SEAL (치근단 역충전와동의 건조방법이 폐쇄성에 미치는 영향)

  • Lee, Jung-Tae;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.166-179
    • /
    • 1999
  • Apical sealing is essential for the success of surgical endodontic treatment. Root-end cavity is apt to be contaminated with moisture or blood, and is not always easy to be dried completely. The purpose of this study was to evaluate the influence of dry methods of retrocavity on the apical seal in endodontic surgery. Apical seal was investigated through the evaluation of apical leakage and adaptation of filling material over the cavity wall. To investigate the influence of various dry methods on the apical leakage, 125 palatal roots of extracted human maxillary molar teeth were used. The clinical crown of each tooth was removed at 10 mm from the root apex using a slow-speed diamond saw and water spray. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. After removing of the coronal 2 mm of filling material, the access cavities were closed with Cavit$^{(R)}$. Two coats of nail polish were applied to the external surface of each root. Apical three millimeters of each root was resected perpendicular to the long axis of the root with a diamond saw. Class I retrograde cavities were prepared with ultrasonic instruments. Retrocavities were washed with physiologic saline solution and dried with various methods or contaminated with human blood. Retrocavities were filled either with IRM, Super EBA or composite resin. All the specimens were immersed in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using one-way ANOVA and Duncan's Multiple Range Test. To evaluate the influence of various dry methods on the adaptation of filling material over the cavity wall, 12 palatal roots of extracted human maxillary molar teeth were used. After all the roots were prepared and filled, and retrograde cavities were made and filled as above, roots were sectioned longitudinally. Filling-dentin interface of cut surfaces were examined by scanning electron microscope. The results were as follows: 1. Cavities dried with paper point or compressed air showed less leakage than those dried with cotton pellet in Super EBA filled cavity (p<0.05). However, there was no difference between paper point- and compressed air-dried cavities. 2. When cavities were dried with compressed air, dentin-bonded composite resin-filled cavities showed less apical leakage than IRM- or Super EBA-filled ones (p<0.05). 3. Regardless of the filling material, cavities contaminated with human blood showed significantly more apical leakage than those dried with compressed air after saline irrigation (p<0.05). 4. Outer half of the cavity showed larger dentin-filling interface gap than inner half did when cavities were filled with IRM or Super EBA. 5. In all the filling material groups, cavities contaminated with blood or dried with cotton pellets only showed larger defects at the base of the cavity than ones dried with paper points or compressed air.

  • PDF