• Title/Summary/Keyword: nTOF

Search Result 172, Processing Time 0.028 seconds

A Quantitative Analysis of Nonlinearity Changes of 24 hour Heart Rate Variability of TOF Children Group and Normal Children Group (TOF 소아 집단과 정상 소아 집단의 24 시간 심박동수 변동량의 비선형성 변화에 대한 정량적 분석)

  • Lee, J.M.;Noh, J.I.;Park, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.451-454
    • /
    • 1997
  • It has been reported that sudden cardiac death and ventricular tachycardia occur after treatment of tetralogy of fallot(TOF). It is regarded that ventricular arrythmia is the main source or the sudden cardiac death, but it is not verified. It is likely that TOF has effect on the heart rate variability because of the ventricular arrythmia. We study how complex and periodic heart rate dynamics change in the normal children (n=13) and TOF children (n=13) throughout 24 hours. We recorded 24-hour holter ECG, and segmented each ECG data into 1 hour length. We analyze each HR time series, and quantify the overall complexity of each HR time series by its correlation dimension. We also calculate the power spectrum of HR, and obtain low-frequency component (0.03-0.15Hz) and high-frequency component (0.15-0.4Hz). We compare the results between normal and TOF groups throughout 24 hours. TOF group have lower correlation dimension ($4.055{\pm}0.4134$ vs. $4.9310{\pm}0.2054$, p<0.05) than the normal group, even though there are no significant differences in the low($0.9864{\pm}0.5598$ vs. $1.5560{\pm}0.8325$, p<0.05) and high($1.1168{\pm}0.1.1448$ vs. $0.9271{\pm}0.6528$, p<0.05) frequency components. It can be concluded that HR time series of TOF group are more regular than that of normal group, and that correlation dimension reveals a nonlinear characteristics of HR time series which is not determined in the frequency domain.

  • PDF

Source Image Based New 3D Rotational Angiography for Differential Diagnosis between the Infundibulum and an Internal Carotid Artery Aneurysm : Pilot Study

  • Jang, Hyeongyu;Jung, Woo Sang;Myoung, Seong Uk;Kim, Jung-Jae;Jang, Chang Ki;Cho, Kwang-Chun
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.5
    • /
    • pp.726-731
    • /
    • 2021
  • Objective : Distinguishing between an infundibulum and a true aneurysm is clinically important. This study aimed to evaluate whether using source image based new three-dimensional rotational angiography (S-n3DRA) can increase the rate of aneurysm detection and improve distinction between a true aneurysm and an infundibulum. Methods : Twenty-two consecutive patients with 23 lesions, were evaluated by time-of-flight (TOF) magnetic resonance angiography (MRA), S-n3DRA, and digital subtraction angiography (DSA). The data were retrospectively and independently reviewed by two neurointerventionists, and the diagnoses based on TOF MRA, S-n3DRA, and DSA were compared. The diagnostic efficacy (interobserver agreement and diagnostic performance) of S-n3DRA was compared with that of TOF MRA. Results : S-n3DRA showed higher interobserver agreement (κ=0.923) than TOF MRA (κ=0.465) and significantly higher accuracy than MRA in distinguishing an aneurysm from an infundibulum (p=0.0039). Conclusion : Compared to MRA, S-n3DRA could provide better screening accuracy and information for distinguishing an aneurysm from an infundibulum. Therefore, S-n3DRA has the potential to reduce the need for DSA.

Synthesis of Fullerene Oxide by Fullerene ($C_{70}$) and Various Amino N-Oxides under Ultrasonic Irradiation (초음파 조건에서 여러가지 아민 N-옥시드와 풀러렌($C_{70}$)를 이용한 풀러렌 산화물의 합성)

  • Ko, Weon-Bae;Han, Ji-Yeon;Lim, Young-A;Shin, Won-Jic;Yu, Gu-Yong
    • Elastomers and Composites
    • /
    • v.39 no.2
    • /
    • pp.153-160
    • /
    • 2004
  • Fullerene oxides were synthesized by fullerene ($C_{70}$) and several amine N-oxides such as 3-picoline N-oxide, pyridine N-oxide hydrate, quinoline N-oxide, and isoquinoline N-oxide under ultrasonic condition at $25{\sim}43^{\circ}C$. The reactivity of fullerene ($C_{70}$) with various amine N-oxides undo, ultrasonic irradiation showed the same in all of the proceeding experiments; 3-picoline N-oxide : pyridine N-oxide hydrate : quinoline N-oxide : isoquinoline N-oxide. The MALDI-TOF MS, UV-vis spectrophotometer and HPLC analysis confirmed that the products of fullerene oxidation are [$C_{70}(O)n$] (n=1).

Synthesis of Fullerene Oxides [$C_{70}O_n$] ($n=1{\sim}3$ or n=1) under Microwave Irradiation (마이크로파 조건에서 풀러렌 산화물 [$C_{70}O_n$ ($n=1{\sim}3$ or n=1)의 합성)

  • Ko, Weon-Bae;Ahn, Ju-Hyun;Lim, Young-A;Han, Ji-Yeon;Han, Dong-Sul
    • Elastomers and Composites
    • /
    • v.39 no.4
    • /
    • pp.309-317
    • /
    • 2004
  • Synthesis of fullerene oxides [$C_{70}O_n$] ($n=1{\sim}3$ or n=1) in solid state by fullerene [$C_{70}$] and several oxidants such as 3-chloroperoxy benzoic acid, chromium(VI) oxide, benzoyl peroxide, and trichloroisocyanuric acid was taken place under microwave irradiation. The reactivity in solid state oi fullerene [$C_{70}$] with various oxidants under same microwave condition increased in the order of 3-chloroperoxy benzoic acid > chromium(VI) oxide > trichloroisocyanuric acid ${\simeq}benzoyl$ peroxide. The MALDI-TOF-MS, UV-visible spectra and HPLC analysis confirmed that the products of fullerene oxidation were [$C_{70}O_n$] ($n=1{\sim}3$ or n=1).

Repair of Tetralogy of Fallot in Infancy via the Atrioventricular Approach

  • Bigdelian, Hamid;Sedighi, Mohsen
    • Journal of Chest Surgery
    • /
    • v.49 no.1
    • /
    • pp.9-14
    • /
    • 2016
  • Background: Tetralogy of Fallot (TOF) is a well-recognized congenital heart disease. Despite improvements in the outcomes of surgical repair, the optimal timing of surgery and type of surgical management of patients with TOF remains controversial. The purpose of this study was to assess outcomes following the repair of TOF in infants depending on the surgical procedure used. Methods: This study involved the retrospective review of 120 patients who underwent TOF repair between 2010 and 2013. Patients were divided into three groups depending on the surgical procedure that they underwent. Corrective surgery was done via the transventricular approach (n=40), the transatrial approach (n=40), or a combined atrioventricular approach (n=40). Demographic data and the outcomes of the surgical procedures were compared among the groups. Results: In the atrioventricular group, the incidence of the following complications was found to be significantly lower than in the other groups: complete heart block (p=0.034), right ventricular failure (p=0.027) and mediastinal bleeding (p=0.007). Patients in the atrioventricular group had a better postoperative right ventricular ejection fraction (p=0.001). No statistically significant differences were observed among the three surgical groups in the occurrence of tachycardia, renal failure, and tricuspid incompetence. The one-year survival rates in the three groups were 95%, 90%, and 97.5%, respectively (p=0.395). Conclusion: Combined atrioventricular repair of TOF in infancy can be safely performed, with acceptable surgical risk, a low incidence of reoperation, good ventricular function outcomes, and an excellent survival rate.

Global Absolute Quantitation of Proteins in Human Whole Saliva by nLC-QIMS-TOF Employing MSE

  • Cho, Ha Ra;Jin, Sung Giu;Park, Jun Seo;Kim, Han Sol;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • v.8 no.4
    • /
    • pp.114-118
    • /
    • 2017
  • While saliva can be considered as good biological fluid for monitoring biomarkers due to many advantages including its communication with blood and the non-invasive nature during its sampling, its applications to that purpose is still limited. As a part of efforts to expand the applications of saliva to the protein biomarker research, we carried out global absolute quantitation of proteins in human whole saliva (WS) by bottom-up proteomics techniques mainly based on nLC-Q-IMS-TOF employing $MS^E$. From the analyses of a pooled WS sample collected from 22 healthy Korean volunteers, 93 proteins ranging from $5.89{\times}10^1ng/mL$ (immunoglobulin heavy chain) to $1.59{\times}10^4ng/mL$ (${\alpha}-amylase$ 1) were confirmed. For the validation of the present results, human serum albumin in the same sample was quantitated by ELISA and its result was compared with that from the nLC-Q-IMS-TOF study. As a result, there was no significant difference between two results from individual approaches ($1.18{\times}10^4{\pm}0.03{\times}10^4 ng/mL$ from nLC-Q-IMS-TOF experiments vs. $1.23{\times}10^4{\pm}0.07{\times}10^4ng/mL$ from ELISA experiments, n=3, p=0.309). To our knowledge, this is the first global absolute quantitation of proteins in human whole saliva and information from the present study can be widely used as the first level reference for the discovery of new protein biomarkers from human whole saliva as well as for quantitative applications of human whole saliva proteins.

Rapid Identification of Staphylococcus Species Isolated from Food Samples by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

  • Kim, Eiseul;Kim, Hyun-Joong;Yang, Seung-Min;Kim, Chang-Gyeom;Choo, Dong-Won;Kim, Hae-Yeong
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.4
    • /
    • pp.548-557
    • /
    • 2019
  • Staphylococcus species have a ubiquitous habitat in a wide range of foods, thus the ability to identify staphylococci at the species level is critical in the food industry. In this study, we performed rapid identification of Staphylococcus species using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight mass spectrometry (MALDI-TOF MS). MALDI-TOF MS was evaluated for the identification of Staphylococcus reference strains (n = 19) and isolates (n = 96) from various foods with consideration for the impact of sample preparation methods and incubation period. Additionally, the spectra of isolated Staphylococcus strains were analyzed using principal component analysis (PCA) and a main spectra profile (MSP)-based dendrogram. MALDI-TOF MS accurately identified Staphylococcus reference strains and isolated strains: the highest performance was by the EX method (83.3~89.5% accuracy) at species level identification (EDT, 70.3~78.9% accuracy; DT, less than 46.3~63.2% accuracy) of 24-h cultured colonies. Identification results at the genus level were 100% accurate at EDT, EX sample preparation and 24-h incubation time. On the other hand, the DT method showed relatively low identification accuracy in all extraction methods and incubation times. The analyzed spectra and MSP-based dendrogram showed that the isolated Staphylococcus strains were characterized at the species level. The performance analysis of MALDI-TOF MS shows the method has the potential ability to discriminate between Staphylococcus species from foods in Korea. This study provides valuable information that MALDI-TOF MS can be applied to monitor microbial populations and pathogenic bacteria in the food industry thereby contributing to food safety.

The Oxidation of Fullerene[$C_{60}$] using Several Oxidants under Microwave Irradiation (마이크로파 조건에서 여러가지 산화제를 이용한 풀러렌[$C_{60}$의 산화반응)

  • Ko, Weon-Bae;Hwang, Sung-Ho;Ahn, Ju-Hyun
    • Elastomers and Composites
    • /
    • v.40 no.1
    • /
    • pp.45-52
    • /
    • 2005
  • Synthesis or fullerene oxides[$C_{60}(O)_n$] ($n=1{\sim}4$ or n=1) by fullerene[$C_{60}$] and several oxidants such as 3-chloroperoxy benzoic acid, benzoyl peroxide, trichloroisocyanuric acid, and chromium(VI) oxide took place under microwave irradiation. The reactivity in solid state of fullerene[$C_{60}$] with various oxidants under same microwave rendition increased in order or 3- chloroperoxy benzoic acid > benzoyl peroxide > trichloroisocyanuric acid $\simeq$chromium(VI) oxide. The MALDI-TOF-MS, UV-visible spectra and HPLC analysis confirmed that the products of fullerene oxidation were [$C_{60}(O)_n$] ($n=1{\sim}4$ or n=1).

Investigation of Angiotensin Glycosylation by MALDI-TOF and ESI Tandem Mass Spectrometry

  • Park, Soo-Jin;Park, Deok-Hie;Sul, Soo-Hwan;Oh, Sung-Hwan F.;Park, In-Sook;Chung, Doo-Soo;Kim, Hie-Joon;Kim, Min-Sik;Lee, Sang-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.12
    • /
    • pp.1791-1800
    • /
    • 2004
  • Angiotensin I, a model decapeptide, was glycosylated and partially hydrolyzed with HCl (6 N, 80 $^{\circ}C$, 4 h), aminopeptidase, and carboxypeptidase Y. A single peptide mass map obtained from truncated peptides in the partial acid hydrolysate of angiotensin and its glycosylation product mixture by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry enabled sequencing of angiotensin by a combinatorial procedure. MALDI-TOF and electrospray ionization (ESI) tandem mass spectrometric results indicate that both the N-terminal amino group of aspartic acid and the guanidinium group of the second residue arginine are glycosylated.

Sonochemical Synthesis of Fullerene Oxides $[C_{70}O_n](n=1{\sim}2)$ Using Metal Hexacarbonyl Complexes $M(CO)_6$ (M=Cr, Mo, W) Under Air Atmosphere (공기 중에서 금속 헥사카르보닐 착물 $M(CO)_6$ (M=Cr, Mo, W)를 이용한 폴러렌 산화물 $[C_{70}O_n](n=1{\sim}2)$의 초음파화학 합성)

  • Ko, Weon-Bae;Park, Young-Hwan
    • Elastomers and Composites
    • /
    • v.40 no.3
    • /
    • pp.174-180
    • /
    • 2005
  • Sonochemical synthesis of fullerene oxides $[C_{70}O_n](n=1{\sim}2)$ by fullerene$[C_{70}]$ and metal hexacarbonyl complexes $M(CO)_6$(M=Cr, Mo, W) took place under air atmosphere. The reactivity of fullerene$[C_{70}]$ and several metal hexacarbonyl complexes $M(CO)_6$(M=Cr, Mo, W) under same ultrasonic condition increased in the order of $Mo(CO)_6$ > $W(CO)_6$ > $Cr(CO)_6$. The MALDI-TOF-MS, UV-visible spectra, and HPLC analysis confirmed that the products of sonochemical reaction were $[C_{70}O_n](n=1{\sim}2)$.