• Title/Summary/Keyword: n-screen

Search Result 532, Processing Time 0.024 seconds

Evaluation of the Output Dose of a Linear Accelerator Photon Beams by Using the Ionization Chamber TM31010 Series through TG-51 Protocol to Postal Monitoring Output of RPC for 5 Years (TM31010 계열의 공동이온전리함과 TG-51을 이용한 선형가속기광자선의 5년간 출력선량 평가)

  • Choi, Tae-Jin;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.92-98
    • /
    • 2011
  • This study is to keep the accuracy and stability of the output dose evaluations for linear accelerator photon beams by using the air ionization chambers (TM31010, 0.125 cc, PTW) through the Task Group 51 protocol. The absorbed dose to water calibration factor $N_{dw}{^{Co-60}}$ was delivered from the air kerma calibration factor $N_k$ which was provided from manufacture through SSDL calibration for determination of output factor. The ionization chamber of TM31010 series was reviewed the calibration factor and other parameters for reduce the uncertainty within ${\pm}2%$ discrepancy and we found the supplied $N_{dw}{^{Co-60}}$ which was derived from Nk has shown a -2.8% uncertainty compare to that of PSDL. The authors provided the program to perform the output dosimetry with TG-51 protocol as it is composed same screen of TG-51 worksheets. The evaluated dose by determination of output factor delivered to postal TLD block for comparison the output dose to that of MDACC (RPC) in postal monitoring program. The results have shown the $1.001{\pm}0.013$ for 6 MV and $0.997{\pm}0.012$ discrepancy for 15 MV X rays for 5 years followed. This study shows the evaluated outputs for linear accelerate photon beams are very close to that of international output monitor with small discrepancy of ${\pm}1.3%$ with high reliability and showing the gradually stability after 2010.

The Development of Filter for Environmental Improvement in Land Based Seawater Fish Farm II. Purification efficacy of Inlet and Outlet Seawater by Filter (필터의 개발을 통한 해수 육상수조식 양식장의 환경개선에 관한 연구 II. 필터 운행에 따른 유입수 및 배출수의 정화효과)

  • KANG Ju-Chan;PARK Soo-Il;KIM Seoung-Gun
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.6
    • /
    • pp.914-919
    • /
    • 1998
  • This study was conducted to evaluate the purification efficacy by filter and ultra violet (UV) irradiation against inlet and outlet seawater of the land based fish farm. Purification efficacies for inlet seawater (50$\ell$/min) has been examined with filter of 60$\mu$m pore size and UV irradiation at an average dose 0.5 mWS/$cm^2$ for 5 months. For outlet seawater filter of 90 $\mu$m pore size only was used. Temperature, salinity, pH, $NO_3-N,\;NO_2-N,\;NH_4-N,\;PO_4-P$, DO and COD of inlet and outlet seawater in the system were not influenced. However, the removing rate of suspended solid and turbidity of inlet seawater were appeared to be $48.7\~65.6\%$ (average $51.9\%$) and $33/3\~42/5\%$ (average $34.8\%$) after passing through screen filter respectively. Also, germicidal efficiency to the total bacteris and Vibrio species were $16.7\~20.2\%$ (average $19.2\%$) $20.0\~21.9\%$ (average $20.9\%$) respectively after passing through UV irradiation. After passing through drum filter of 90$\mu$m pore size, suspended solid and turbidity of outlet seawater were appeared to be $42.7\~52.6\%$ (average $46.9\%$), $27.7\~29.9\%$ (average $28.3\%$), respectively.

  • PDF

Voltammetric Determination of Dopamine with the N-Hydroxysuccinimide Modified Carbon Paste Electrode (N-히드록시숙신이미드로 수식한 탄소반죽전극을 이용한 도파민의 전기화학적 측정)

  • Yoo Jae Hyun;Yoo Byung Wook;Kim Soon Shin;Uhm Jung Hee;Nam Hakhyun;Cha Geun Sig
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.3
    • /
    • pp.109-112
    • /
    • 2001
  • An activated carbon paste electrode was modified with the N-Hydroxysuccinimide(NHS) layer and applied to determine the dopamine in the presence of an excess ascorbic acid using square-wave voltammetry. The electrochemical properties of the modified electrode were examined in the solution containing dopamine/ascorbic acid using cyclic voltammetry(CV): the separation between the oxidation peaks of dopamine and ascorbic acid was largely dependent on the pH of the sample solution and became maximum at pH 4.0. Hence, the square-wave voltammetric determination of dopamine was carried out in a pH 4.0, 100mM phosphate buffer saline(PBS) containing 140mM NaCl. The detection limit and response slop were improved from $1.0{\mu}M\;to\;5.0\times10^{-2}{\mu}M\;and\;from\;0.93{\mu}A/{\mu}M\;to\;6.1{\mu}A/{\mu}M$, respectively, upon modification of the electrode surface by NHS.

Analysis of Contact Properties by Varying the Firing Condition of AgAl Electrode for n-type Crystalline Silicon Solar Cell (AgAl 전극 고온 소성 조건 가변에 따른 N-형 결정질 실리콘 태양전지의 접촉 특성 분석)

  • Oh, Dong-Hyun;Chung, Sung-Youn;Jeon, Min-Han;Kang, Ji-Woon;Shim, Gyeong-Bae;Park, Cheol-Min;Kim, Hyun-Hoo;Yi, Jun-Sin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.8
    • /
    • pp.461-465
    • /
    • 2016
  • n-type silicon shows the better tolerance towards metal impurities with a higher minority carrier lifetime compared to p-type silicon substrate. Due to better lifetime stability as compared to p-type during illumination made the photovoltaic community to switch toward n-type wafers for high efficiency silicon solar cells. We fabricated the front electrode of the n-type solar cell with AgAl paste. The electrodes characteristics of the AgAl paste depend on the contact junction depth that is closely related to the firing temperature. Metal contact depth with p+ emitter, with optimized depth is important as it influence the resistance. In this study, we optimize the firing condition for the effective formation of the metal depth by varying the firing condition. The firing was carried out at temperatures below $670^{\circ}C$ with low contact depth and high contact resistance. It was noted that the contact resistance was reduced with the increase of firing temperature. The contact resistance of $5.99m{\Omega}cm^2$ was shown for the optimum firing temperature of $865^{\circ}C$. Over $900^{\circ}C$, contact junction is bonded to the Si through the emitter, resulting the contact resistance to shunt. we obtained photovoltaic parameter such as fill factor of 76.68%, short-circuit current of $40.2mA/cm^2$, open-circuit voltage of 620 mV and convert efficiency of 19.11%.

Mental Health Screening in Schools (학생정신건강검진 시범운영사업에 따른 추진방안)

  • Kim, Hyoun-Jeong;Kim, Yun-Young;Lee, Hye-Sook;Hyun, Mi-Na;Nam, Dong-Hyun;Kim, Sang-Won;Ahn, Dong-Hyun
    • Journal of the Korean Society of School Health
    • /
    • v.22 no.1
    • /
    • pp.33-48
    • /
    • 2009
  • Purpose: The purpose of the study was to find the strategies of mental health screening in school. Based on the literature review, we discuss the importance of screening students in schools for mental health problems. Methods: Data from the 2008 Korean Mental Health Screening in Schools(2008-KMHSS) are used to estimate the outline of this screening. We administered the questionnaire for satisfaction of 2008-KMHSS for students(N=1,280), parents(N=2,672), school nurses(N=75), teachers(N=685), district personnels(N=6), and mental health center staffs(N=37). Also we interviewed a part of them by telephone and e-mail. And we reviewed the tools and methods for screening students for emotional/behavioral problems. Results: Mental health screening in schools is a very important, yet worrisome, agenda that is in its very early stages. From the 2008 Korean Mental Health Screening in Schools, 9,588 students(12.9%) needed more evaluation in the first stage. Of these, 6,910(72.1%) completed the second stage screening. In this sample, 1,975(28.6%) utilized the mental health services in school or community. 38.3% of students and 43.7% of their parents notified the 2008-KMHSS. But only 12.1% of students and 10.9% of their parents dissatisfied with the screening. 9.9% of teachers and 22.7% of school nurses dissatisfied with the screening. Among them the school nurses were mostly dissatisfied, and they complained work burden from KMHSS. Mental health center staffs complained similar issues. The Children's Problem-behavior Screening Questionnaire(CPSQ) and Adolescents' Mental-health & Problem-behavior Screening Questionnaire(AMPQ) were compatible to screen students in schools for mental health problems in first stage. Conclusion: Mental health screening in schools needs careful planning and implementation. For successful mental health screening in schools, several elements need to be considered: careful planning, collaboration, staff training, and integrative mental health programs and services in community or schools.

Identification and Functional Analysis of Escherichia coli RNase E Mutants (Escherichia coli 리보핵산 내부분해효소 RNase E의 돌연변이체 선별 및 특성분석)

  • Shin, Eun-Kyoung;Go, Ha-Young;Kim, Young-Min;Ju, Se-Jin;Lee, Kang-Seok
    • Korean Journal of Microbiology
    • /
    • v.43 no.4
    • /
    • pp.325-330
    • /
    • 2007
  • RNase E is an essential Escherichia coli endoribonuclease that plays a major role in the decay and processing of a large fraction of RNAs in the cell and expression of N-terminal domain consisted of 1-498 amino acids (N-Rne) is sufficient to support normal cellular growth. By utilizing these properties of RNase E, we developed a genetic system to screen for amino acid substitutions in the catalytic domain of the protein (N-Rne) that lead to various phenotypes. Using this system, we identified three kinds of mutants. A mutant N-Rne containing amino acid substitution in the S1 domain (I6T) of the protein was not able to support survival of E. coli cells, and another mutant N-Rne with amino acid substitution at the position 488 (R488C) in the small domain enabled N-Rne to have an elevated ribonucleolytic activity, while amino acid substitution in the DNase I domain (N305D) only enabled N-Rne to support survival of E. roli cells when the mutant N-Rne was over-expressed. Analysis of copy number of ColEl-type plasmid revealed that effects of amino acid substitution on the ability of N-Rne to support cellular growth stemmed from their differential effects on the ribonucleolytic activity of N-Rne in the cell. These results imply that the genetic system developed in this study can be used to isolate mutant RNase E with various phenotypes, which would help to unveil a functional role of each subdomain of the protein in the regulation of RNA stability in E. coli.

The Rapid Detection of Antioxidants from Safflower Seeds (Carthamus tinctorius L.) Using Hyphenated-HPLC Techniques (Hyphenated-HPLC 기술을 활용한 홍화씨의 항산화 성분 분석)

  • Kim, Su-Jin;Kim, Sang-Min;Kang, Suk-Woo;Um, Byung-Hun
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.414-419
    • /
    • 2010
  • Hyphenated-HPLC techniques combine the separation power of HPLC with the structural and bioactivity information provided by NMR, ESI/MS, and an on-line antioxidant screening system. The major advantages over the traditional off-line techniques are rapidity and efficiency. In this study, we used hyphenated HPLC techniques including online HPLC-ABTS, LC-NMR, and LC-MS todirectly identify the major antioxidants of safflower (Carthamus tinctorius L.) seeds. The results demonstrated that the major antioxidant compounds from on-line HPLC-ABTS analysis were identified as 8'-hydroxyarcgenin-4'-O-$\beta$-D-glucoside, N-(p-coumaroyl) serotonin, and N-feruloylserotonin. Among them, N-feruloylserotonin accounted for almost 50% of the ABTS radical scavenging activity of the total extract. The results demonstrate that HPLC hyphenated techniques can be used to rapidly screen and structurally identify antioxidants from crude plant extracts.

Radiographic evaluation of alveolar bone profile of maxillary anterior teeth in Korean young adult (한국인 성인의 상악 전치부 치조골 형태에 관한 방사선학적 연구)

  • Seo, Hyo-Seok;Chung, Chin-Hyung;Lim, Sung-Bin;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.461-471
    • /
    • 2006
  • In order to achieve a satisfactory esthetic result of periodontal surgery or implant in maxillary anterior area, periodontists must be aware of normal alveolar bone anatomy. The purpose of this study was to evaluate the relationship of alveolar bone morphology to tooth shape and form. 78(mean age : 25 yrs) periodontally healthy volunteers participated in this study. Two maxillary central incisor and one lateral incisor were selected to study. With minimal local anesthesia, gutta-percha cone inserted to labial gingival sulcus of selected teeth just after bone sounding with periodontal probe. Metal ball (4mm diameter) attached to palatal fossa of central incisor. Then, periapical radiograph was taken according to long cone paralleling technique. After film scan, labial alveolar bone profile reproduced along interproximal bone and apical ends of gutta-percha cones on computer screen. By utilizing computer program, the distance from height of interproximal bone to the labial bone crest in central incisor-central incisor and central incisor-lateral incisor area was measured and converted to real distance by using vertical length of metal ball on film. After measuring crown length & width of central incisor, the 10 individuals ranked lowest GW/L ratio (crown width/length ratio) and the 10 ranked highest were selected as having a long-narrow(group N), or a short-wide(group W) form of the central incisors. Means of the distance from height of interproximal bone to the labial bone crest of group N, W were calculated and compared by means of independent t-test. The results were as follows: 1. Mean distance from the height of the interproximal bone to the labial bone crest was $3.5{\pm}0.7mm$ between two central incisor, and $2.8{\pm}0.6mm$ between central and lateral incisor. 2. Mean GW/L ratio of group N was 0.57, and group W was 0.8. Mean distance from the height of the interproximal bone to the labial bone crest of group N was higher than group W in both measured area(measurements of group N, W were $3.9{\pm0.2mm$ and $3.5{\pm}0.2mm$ between two central incisor, $3.0{\pm}0.2mm$ and $2.8{\pm}0.2mm$ between central and lateral incisor), but there were no statistically significant differences when the groups were compared. Within the limits of the present study, there was a tendency that subjects with long-narrow teeth have more scalloped alveolar bone profile than subjects with short-wide teeth in upper anterior area, but no statistically significant differences were found.

Discharge Standards of Kitchen-Disposer Wastewater by Treatment Types (디스포저(부엌용 오물분쇄기)-배수 전처리 방식 별 수질기준)

  • Chang, Ho Nam;Jeong, Chang Moon;Kang, Jong Won;Choi, Jin-dal-rae;Park, Young Sook;Ku, Ja-Kong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.2
    • /
    • pp.55-69
    • /
    • 2011
  • Use of disposer at the kitchens of Korean apartments is inevitable in treating their foodwaste having a water content of more than 80%. Also we have to ensure that this extra disposer-foodwaste BOD loadings be treated properly by installing/operating a pre-treatment system before this wastewater enters public sewer system. However, the degree of BOD removal should not be excessive since a BOD/N ratio higher than 5 is required for removing N/P at a municipal wastewater treatment plant. The removal of BOD/N in the pretreatment system rather than BOD alone can be an alternative solution in solving this problem. The particles separated by sedimentation, screen or packed-bed can be anaerobically digested at apartment sites to generate biogas that can be used for simple digester heating and to generate volatile fatty acids (VFAs) for nitrogen removal. We suggest that Korean government grants a temporary license (say for 5 years) to foodwaste treatment companies in collaboration with apartment construction companies which may do business and develop various kinds of disposer-foodwaste treatment systems in diverse wastewater discharge systems of Korean apartments.

Water-blocking Asphyxia of N95 Medical Respirator During Hot Environment Work Tasks With Whole-body Enclosed Anti-bioaerosol Suit

  • Jintuo Zhu;Qijun Jiang;Yuxuan Ye;Xinjian He;Jiang Shao;Xinyu Li;Xijie Zhao; Huan Xu;Qi Hu
    • Safety and Health at Work
    • /
    • v.14 no.4
    • /
    • pp.457-466
    • /
    • 2023
  • Background: During hot environment work tasks with whole-body enclosed anti-bioaerosol suit, the combined effect of heavy sweating and exhaled hot humid air may cause the N95 medical respirator to saturate with water/sweat (i.e., water-blocking). Methods: 32 young male subjects with different body mass indexes (BMI) in whole-body protection (N95 medical respirator + one-piece protective suit + head covering + protective face screen + gloves + shoe covers) were asked to simulate waste collecting from each isolated room in a seven-story building at 27-28℃, and the weight, inhalation resistance (Rf), and aerosol penetration of the respirator before worn and after water-blocking were analyzed. Results: All subjects reported water-blocking asphyxia of the N95 respirators within 36-67 min of the task. When water-blocking occurred, the Rf and 10-200 nm total aerosol penetration (Pt) of the respirators reached up to 1270-1810 Pa and 17.3-23.3%, respectively, which were 10 and 8 times of that before wearing. The most penetration particle size of the respirators increased from 49-65 nm before worn to 115-154 nm under water-blocking condition, and the corresponding maximum size-dependent aerosol penetration increased from 2.5-3.5% to 20-27%. With the increase of BMI, the water-blocking occurrence time firstly increased then reduced, while the Rf, Pt, and absorbed water all increased significantly. Conclusions: This study reveals respirator water-blocking and its serious negative impacts on respiratory protection. When performing moderate-to-high-load tasks with whole-body protection in a hot environment, it is recommended that respirator be replaced with a new one at least every hour to avoid water-blocking asphyxia.