• Title/Summary/Keyword: n-decane+ethylbenzene system

Search Result 1, Processing Time 0.015 seconds

Measurement and Prediction of Autoignition Temperature(AIT) of n-Decane+Ethylbenzene System (노말데칸과 에틸벤젠 계의 최소자연발화온도 측정 및 예측)

  • Lee, Jae-Hwa;Kim, Gui-Ju;Hong, Soon-Kang;Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.5
    • /
    • pp.54-60
    • /
    • 2015
  • The autoignition temperature (AIT) of a material is the lowest temperature at which the material will spontaneously ignite. The AIT is important index for the safe handling of flammable liquids which constitute the solvent mixtures. This study measured the AITs of n-decane+ethylbenzene system by using ASTM E659 apparatus. The AITs of n-decane and ethylbenzene which constituted binary system were $210^{\circ}C$ and $430^{\circ}C$, respectively. The experimental AITs of n-decane+ethylbenzene mixture were a good agreement with the calculated AITs by the proposed equations with about $11^{\circ}C$ A.A.D.(average absolute deviation).