• Title/Summary/Keyword: myocardial perfusion imaging

Search Result 87, Processing Time 0.021 seconds

Comparison of Diagnostic Accuracy for Detecting Coronary Artery Disease of Dipyridamole $^{99m}Tc$-MIBI Myocardial SPECT and It's Defect Map between Men and Women (디피리다몰 부하 $^{99m}Tc$-MIBI 심근 SPECT 극성결손지도를 이용한 관동맥질환 진단의 남녀 비교)

  • Bae, Sang-Kyun;Lee, Dong-Soo;Oh, Byung-Hee;Chung, June-Key;Lee, Myoung-Mook;Park, Young-Bae;Lee, Myung-Chul;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.59-64
    • /
    • 1993
  • To evaluate the usefulness and differences in diagnosing coronary artery disease (CAD) between men and women of intravenous dipyridamole $^{99m}Tc$-MIBI myocardial SPECT, we obtained $^{99m}Tc$-MIBI myocardial SPECT and compared with the findings of coronary angiographies. Ninety eight male and 37 female patients who underwent dipyridamole $^{99m}Tc$-MIBI myocardial imaging within one month of cardiac catheterization were studied. Scans were considered abnormal if perfusion defect was detected and the defect size was more than 12% for left anterior descending artery (LAD) and circumflex (LCX) and 8% for right coronary artery (RCA) territories. Lesions${\geqq}$50% luminal diameter narrowing were considered significant CAD. Overall sensitivity for detection of CAD was 94.3% in men and 96.4% in women; specificity was 70% in men and 52.6% in women (P=not significant, ns). Vessel-matched sensitivity was 75.3% in men and 72.7% in women (P=ns): specificity was 84.6% in men and 67.9% in women (P < 0.025). For individual coronary artery, the sensitivity in men and women was 87.7%, 81.8% for LAD; 78%, 83.3% for RCA and 52.2%, 46.7% for LCX (P=ns): the specificity was 80%, 40% for LAD (P<0.01), 82.5%, 68.4% for RCA, 88.9%, 86.4% for LCX (P=ns). The hemodynamic parameter after intravenous dipyridamole in men and women were significantly changed; the heart rate was increased and systolic, diastolic blood pressure was decreased. Adverse effects were reported in 58.8% of men and 72.7% in women (P=ns). The incidence of chest pain and headache were higher in women. There was no significant difference in the incidences of nausea, abdominal pain, dizziness, facial flushing, dyspnea. In conclusion, dipyridamole $^{99m}Tc$-MIBI myocardial SPECT is a safe, noninvasive test for evaluation of CAD. There was no gender difference to detect CAD, but more false-positive rate in women especially in the territory of LAD.

  • PDF

Assessment of Viability in Regional Myocardium with Reversed Redistribution by Thallium Reinjection in Patients with Acute Myocardial Infarction (급성심근경색 환자에서 역재분포를 보인 심근의 Thallium 재주사에 의한 생존능의 평가)

  • Yoon, Seok-Nam;Park, Chan-H.;Pai, Moon-Sun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.6
    • /
    • pp.509-515
    • /
    • 1998
  • Purpose: The aim of this study was to evaluate whether T1-201 reinjection distinguishes viable from non-viable myocardium in patients with reverse redistribution after acute myocardial infarction. Materials and Methods: We studied 42 patients with acute myocardial infarction (age, $55{\pm}12$ years). Eighteen (43%) out of 42 showed reverse redistribution on dipyridamole stress-4 hour redistribution T1-201 single photon emission computed tomography (SPECT). T1-201 reinjection was performed at 24 hours. Reverse redistribution was defined as worsening of perfusion defect at 4 hour delayed scan. All patients underwent follow-up echocardiography in 4 months to assess regional wall motion improvement. T1-201 uptake on reinjection images were analyzed for the prediction of myocardial wall motion improvement. Results: Of 36 segments with reverse redistribution, 17 segments showed normal wall motion on echocardiography, while 19 segments showed wall motion abnormalities. Of 19 the segments with reverse redistribution, 11 (58%) showed enhanced uptake after 24 hour reinjection. Myocardial wall motion was improved in 10 of 11 segments (90%) with enhanced uptake on reinjection. Wall motion improvement was not seen in 5 of 8 segments (63%) without enhanced thallium uptake. When myocardial viability was assessed by the uptake on reinjection image, nine of 10 segments (90%) with normal or mildly decreased uptake showed improved wall motion. Wall motion was not improved in 5 of 9 segments (16%) with severely decreased uptake. Conclusion: In patients with acute myocardial infarction, T1-201 reinjection imaging on myocardial segments with reverse redistribution has a high positive predictive value in the assessment of myocardial viability.

  • PDF

Internal maxillary artery (IMax) - middle cerebral artery bypass in a patient with bilateral atherosclerotic carotid occlusion: A technical case report

  • Javier Degollado-Garcia;Martin R. Casas-Martinez;Bill Roy Ferrufino Mejia;Juan C. Balcazar-Padron;Hector A. Rodriguez-Rubio;Edgar Nathal
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.26 no.1
    • /
    • pp.51-57
    • /
    • 2024
  • Since the first description of the possible utilization of the internal maxillary artery for bypass surgery, there are some reports of its use in aneurysm cases; however, there is no information about the possible advantages of this type of bypass for cerebral ischemic disease. We present a 77-year-old man with a history of diabetes, hypertension, systemic atherosclerosis, and two acute myocardial infarctions with left hemiparesis. Imaging studies reported total occlusion of the right internal carotid artery and 75% occlusion on the left side, with an old opercular infarction and repeated transient ischemic attacks in the right middle cerebral artery territory despite medical treatment. After a consensus, we decided to perform a bypass from the internal maxillary artery to the M2 segment of the middle cerebral artery using a radial artery graft. After performing the proximal anastomosis, the calculated graft's free flow was 216 ml/min. Subsequently, after completing the bypass, the patency was confirmed with fluorescein videoangiography and intraoperative Doppler. Postoperatively, imaging studies showed improvement in the perfusion values and the hemiparesis from 3/5 to 4+/5. The patient was discharged one week after the operation, with a modified Rankin scale of 1, without added deficits. The use of revascularization techniques in steno-occlusive disease indicates a select group of patients that may benefit from this procedure. In addition, internal maxillary artery bypass has provided a safe option for large areas of ischemia that cannot be supplied with a superficial temporal artery - middle cerebral artery bypass.

Motion Reduction Activities in Patients undergoing Myocardial Perfusion SPECT with the Discovery NM 530c(D530c) (Discovery NM 530c(D530c)에서 촬영한 심근관류 SPECT 환자의 움직임 감소활동을 위한 연구)

  • Lee, Dong Hun;Choi, Woo Jun;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.80-85
    • /
    • 2017
  • Purpose The D530c have cadmium zinc telluride(CZT) detectors that are arranged focus on the heart. This structural characteristic allows for quicker imaging without rotation, but this is sensitive to patient movement and can affect the test results. The aim of this study is to optimize the image quality by reducing patient movement during the examination. Materials and Methods We analyzed the patients' movements, and performed various activities such as provided patient education about correct breathing techniques and avoiding patient movements, and created breathing correction tools to minimize patient movement during exam. The 70 patients who underwent myocardial perfusion SPECT with D530c in November 2016 were categorized as the group before the corrective steps. Another 70 patients who underwent the procedure with D530c from February 14, 2017 to February 21, 2017 were categorized as the improvement group. Images acquired during stress and at rest were compared and analyzed by measuring the durations of heart movements over certain distances (4 mm, 8 mm, 12 mm, or more) noted on the x-, y-, and zaxes. Results After the activities, the durations of heart movements decreased in the images acquired both under stress and at rest. In particular, there were no large motions greater than 12 mm recorded in the stress images after the improvement. There was a significant difference (p<0.005) in the 4-mm and 8-mm fluctuations on the X-axis and the 8-mm fluctuations on the Z axis in the stress images, but there was no significant difference (p>0.005) in the other stress and rest intervals. Conclusion The decrease in the time of motion occurrence due to the 4 mm fluctuation distance that can occur through breathing can be understood as a result of the breathing being corrected through training and motion prevention tools. It is expected that the image quality will be improved by reducing the occurrence time according to the variation distance of 8 mm or 12 mm, which is expected as the actual movement of the patient other than the breathing.

  • PDF

Development of an exclusive column method for 82Sr/82Rb generator using a 100 MeV proton linear accelerator of KOMAC

  • Kye-Ryung Kim;Yeong Su Ha;Sang-Pil Yoon;Yeon-ji Lee;Yong-Sub Cho;Hyeongi Kim;Sang-Jin Han;Jung Young Kim;Kyo Chul Lee;Jin Su Kim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.7 no.2
    • /
    • pp.119-125
    • /
    • 2021
  • 82Sr for 82Rb generator was produced through the irradiation of the proton beam on the nat.RbCI target at the target irradiation facility installed at the end of the Rl-dedicated beamline of the 100 MeV proton linear accelerator of KOMAC (Korea Multi-purpose Accelerator Complex). The average current of the proton beam was 1.2 µA for irradiation time of 150 min. For the separation and purification of the 82Sr from nat.RbCI irradiated, Chelex-100 resin was used. The activities of 82Sr in the irradiated nat.RbCI target solution and after purification were 45.29 µCi and 43.4 µCi, respectively. The separation and purification yield was 95.8%. As an adsorbent to be filled in the generator for 82Sr adsorption hydrous tin oxide was selected. The adsorption yield of 82Sr into the generator adsorbent was > 99 %, and the total amount of 82Sr adsorbed to the generator was 21.6 µCi as of the day of the 82Rb elution experiment. When the elution amount was 22 mL, the maximum82Rb elution yield was 93.3%, and the elution yield increased as the flow rate increased. After the eluted 82Rb was filled in the correction phantom of the small PET for animals, a PET image was taken. The image scan time was set to 5 min, and the phantom PET image was successfully obtained. As results of impurity analysis on eluted 82Rb using ICP-MS, nat.Rb stable isotopes that compete in vivo of 82Rb were identified as undetected levels and were determined to be No-Carrier-Added (NCA).

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF

Usefulness of $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT in Benign and Malignant Lesion of the Lungs (폐의 양성 및 악성 병변에서 $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT의 진단적 가치)

  • Kim, Seong-Suk;Kim, Ki-Beom;Cho, Young-Bok;Cho, In-Ho;Lee, Kyung-Hee;Chung, Jin-Hong;Lee, Hyoung-Woo;Lee, Kwan-Ho;Lee, Hyun-Woo;Kim, Mi-Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.54-62
    • /
    • 1996
  • Background: $^{99m}Tc$ MIBI(Methoxyisobutylisonitrile complex), a member of the isonitrile class of coordination compounds, is a lipophilic cation presently under investigation for clinical use as myocardial perfusion imaging agent and is widely used to detect myocardial infarction. Preliminary reports indicate that $T_1$-201 accumulate in human neoplasm and several authors reported $^{99m}Tc$ MIBI may also localized in primary malignant tumor and metastatic deposits from lung cancer. We evaluated the uptake of $^{99m}Tc$ MIBI in lung cancer and localization of mediastinal and other site metastasis, and compared the benign lesion of the lung. Method: Thirty four patients of lung cancer and ten patients of benign lung lesion were studied with chest CT and $^{99m}Tc$ MIBI Lung SPECT. $^{99m}Tc$ MIBI uptake ratio was assessed by TR/NL(Lung lesion/ Normal area), HT/NL (Heart/Normal area) and HT/TR(Heart/Lung lesion). Results: 1) All lung cancer patients showed increased uptakes of $^{99m}Tc$ MIBI in malignant lung lesion and Tc-99m MIBI uptake was also increased in mediastinal and lymph node metastasis except two cases. 2) There was significant different ratio of TR/NL between malignant and benign lesion, $3.79{\pm}1.82$ and $1.67{\pm}0.63$ on planar images, respectively(p<0.001). 3) There was no significant difference of $^{99m}Tc$ MIBI uptake ratio between squamous cell carcinoma, small cell carcinoma and adeno carcinoma($3.64{\pm}1.66$, $3.57{\pm}0.72$, $4.31{\pm}2.28$ respectively). Conclusion: $^{99m}Tc$ MIBI lung SPECT was useful in the localization of tumor and mediastinal or other site metastatic lesion in lung cancer and also in the differential diagnosis between benign and malignant lesion.

  • PDF