• Title/Summary/Keyword: myocardial perfusion SPECT

Search Result 138, Processing Time 0.019 seconds

New Imaging Techniques in Myocardial Perfusion SPECT (심근 관류 SOECT의 새로운 방법)

  • Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • Gated myocardial SPECT and attenuation correction gave birth to new insights into the pathophysiology of ischemic myocardial perfusion and function in clinical routine practice. Gated myocardial Tc-99m-compound SPECT improved diagnostic accuracy of coronary artery disease and enabled us to observe motion and thickening of myocardial walls as well as myocardial perfusion at the same time. Quantitative and qualitative assessment of myocardial performance and perfusion let us to understand the myocardial physiology in ischemia and infarction. In every patient who underwent gated perfusion SPECT, we will find ejection fraction, left ventricular volumes and regional wall motion. There are hopes to use gated TI-201 SPECT for the same purpose and to use gated SPECT for evaluation of wall motion and thickening at stress or immediate post-stress. Attenuation correction could improve diagnostic accuracy mainly by increasing normalcy ratio or performance of non-expert physicians. Both gated methods and attenuation correction improved specificity of non-expert physicians in diagnosing patients with moderate pretest likelihood. New imaging techniques will fill the desire of cardiologists to examine function and perfusion, and possibly metabolism in their clinical routine practice.

  • PDF

Quantification of Myocardial Perfusion and Function Using SPECT and PET (SPECT와 PET을 이용한 심장관류 및 기능의 정량화)

  • Lee, Jae-Sung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.75-81
    • /
    • 2005
  • Myocardial perfusion and function can be quantified using SPECT and PET. There was controversy over the usefulness of the correction techniques for physical artifacts, such as photon attenuation and scatter, in the quantification of myocardial perfusion using SPECT. However, the cumulated results of many investigations have leaded the consensus on the usefulness of the correction procedures to improve the accuracy and specificity of the myocardial SPECT in the assessment of coronary artery diseases. Although the clinical value of the myocardial perfusion PET has not been preyed yet, the absolute myocardial blood flow and perfusion reserve values quantified using myocardial PET are employed in many basic investigations. In this paper, the methods for the quantitative myocardial SPECT and PET will be reviewed.

Quantitative gated myocardial perfusion SPECT (정량적 게이트 심근관류 SPECT)

  • Ahn, Byeong-Cheol
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.207-218
    • /
    • 2003
  • Myocardial perfusion imaging has been increasingly used to provide prognostic data and guidance on the choice of appropriate management of patients with known or suspected coronary artery disease. The electrocardiogram gated myocardial SPECT program is corning into wide use with an advent of $^{99m}Tc-labeled$ tracers and an improvement of SPECT machines. The gated technique permits measurement of important cardiac prognostic indicators without any further discomforts or radiation burden in patients underwent standard myocardial perfusion SPECT. In addition, gated study significantly improves diagnostic yield by reducing the number of borderline interpretations and could find myocardial stunning and viable myocardium. Gated single photon emission computed tomography (SPECT) imaging allows the automated calculation of end-diastolic volume, end-systolic volume, ejection fraction, myocardial mass and the assessment of regional wall motion and thickening, and it have dramatically improved assessment of coronary artery disease in routine nuclear practice. This allows the simultaneous assessment of both perfusion and function within the same acquisition, and serves as a cost-effective technique for providing more diagnostic data with fewer diagnostic tests. Because the diagnostic and prognostic power derived from knowledge of left ventricular function can be added to that provided by assessing myocardial perfusion, gated SPECT imaging has rapidly gained widespread acceptance and is now used on a routine clinical basis in a growing number of laboratories, including South Korea. The gated SPECT technique for measurement of left ventricular parameters has been validated against a variety of well established techniques. In this work, overview of gated myocardial perfusion SPECT focus on functional parameters is presented.

Usefulness of Myocardial Perfusion SPECT after Percutaneous Coronary Intervention (PCI) (경피적 관상동맥 중재술(Percutanerous Coronary Intervention; PCI) 후 심근 관류 SPECT의 유용성)

  • Lee, Jong-Jin;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.114-117
    • /
    • 2005
  • As the indication of percutaneous coronary intervention (PCI) has expanded to the more difficult and complicated cases, frequent restenosis is still expected after PCI. According to AHA/ACC guideline of the present time, routine use of myocardial perfusion single photon emission tomography (SPECT) is not recommended after coronary intervention, but symptom itself or exercise EKG is not enough for the detection of restensis or for the prediction of event-free survival. In high risk and/or symptomatic subjects, direct coronary angiography is required myocardial perfusion SPECT could detect restenosis in 79% of the patients if performed 2 to 9 months after PCI. Reversible perfusion decrease in the myocardial perfusion SPECT is known to be the major prognostic indicator of major adrerse cardiac event in PCI patients and also the prognosis is benign in the patients without reversible perfusion decrease. Though the cumulated specificity is 79% in the literature and optimal timing of myocardial perfusion SPECT is in controversy, SPECT is recommended even in asymptomatic patients at 3 to 9 months after PCI. Considering the evidences recently reported in the literature, myocardial perfusion SPECT is useful for risk stratification and detection of coronary artery restenosis requiring re-intervention in the asymptomatic patients after PCI.

Diagnosis of Coronary Artery Disease Using Myocardial Perfusion SPECT (심근 SPECT를 이용한 관상동맥질환의 진단)

  • Won, Kyoung-Sook;Kim, Hae-Won
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.3
    • /
    • pp.196-202
    • /
    • 2009
  • Myocardial perfusion scintigraphy is currently by far the most commonly performed cardiac nuclear study, constituting approximately one third of all nuclear medicine procedure. It plays an important role in the diagnosis, prognosis, risk assessment and management of heart disease. Aim of this review is to describe recent evolution of myocardial perfusion imaging on the focus of diagnosis of coronary artery disease. In addition, current status of other imaging modalities will be reviewed.

Comparison of Emergency Tc-99m Sestamibi Myocardial Perfusion SPECT and ECG in the Diagnosis of Acute Myocardial Infarction (급성심근경색증 환자에서 응급으로 시행한 Tc-99m Sestamibi 심근관류 SPECT와 심전도의 비교)

  • Cho, Ihn-Ho;Lee, Hyoung-Woo;Park, Jong-Sun;Won, Kyu-Chang;Do, Jun-Young;Sin, Dong-Gu;Yoon, Kyung-Woo;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.104-111
    • /
    • 1996
  • We did Tc-99m sestamibi myocardial perfusion SPECT in 36 patients with acute myocardial infarction when they arrived at the emergency room. And we compared myocardial perfusion images with ECG findings. Then we obtained the follows. The myocardial infarction by the obstruction of left coronary descending artery and right coronary artery showed a good concordance in the diagnosis and infarction site between myocardial perfusion images and ECG findings. The 7 patients with myocardial infarction by a left circumflex coronary artery showed a perfusion defect in the lateral wall in myocardial perfusion SPECT images. But 4 patients of them showed ST segment elevation, 2 patients showed ST depression and 1 patient showed normal ECG findings. The diagnostic sensitivity of Tc-99m sestamibi myocardial perfusion SPECT was 100% by a qualified analysis. The perfusion defect site in the myocardial perfusion SPECT were corresponded with the infarct related coronary artery in 31 patients which was diagnosed by coronary angiograpy. The size of perfusion defect in the po1ar map was $31{\pm}18%(M{\pm}SD)$, in the myocardial infarction with left anterior descending coronary arery obstruction, $31{\pm}13% (M{\pm}SD)$ in the myocardial infarction with right coronary artery obstruction and $25{\pm}5.9%(M{\pm}SD)$ in the myocardial infarction with left circumflex coronary artery obstruction. We concluded that emergency myocardial perfusion SPECT images are useful in the diagnose of myocardial infarction and it's very useful when we are difficult to diagnose with ECG like as lateral wall infarction or left bundle branch block.

  • PDF

Consideration of Normal Variation of Perfusion Measurements in the Quantitative Analysis of Myocardial Perfusion SPECT: Usefulness in Assessment of Viable Myocardium (심근관류 SPECT의 정량적 분석에서 관류정량값 정상변이의 고려: 생존심근 평가에서의 유용성)

  • Paeng, Jin-Chul;Lim, Il-Han;Kim, Ki-Bong;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.285-291
    • /
    • 2008
  • Purpose: Although automatic quantification software of myocardial perfusion SPECT provides highly objective and reproducible quantitative measurements, there is still some limitation in the direct use of quantitative measurements. In this study we derived parameters using normal variation of perfusion measurements, and tried to test the usefulness of these parameters. Materials and Methods: In order to calculate normal variation of perfusion measurements on myocardial perfusion SPECT, 55 patients (M:F = 28:27) of low-likelihood for coronary artery disease were enrolled and $^{201}TI$ rest/$^{99m}Tc$-MIBI stress SPECT studies were performed. Using 20-segment model, mean (m) and standard deviation (SD) of perfusion were calculated in each segment. As a myocardial viability assessment group, another 48 patients with known coronary artery disease, who underwent coronary artery bypass graft surgery (CABG) were enrolled. $^{201}TI$ rest/$^{99m}Tc$-MIBI stress / $^{201}TI$ 24-hr delayed SPECT was performed before CABG and SPECT was followed up 3 months after CABG. From the preoperative 24-hr delayed SPECT, $Q_{delay}$ (perfusion measurement), ${\Delta}_{delay}$ ($Q_{delay}$ - m) and $Z_{delay}$ (($Q_{delay}$ - m)/SD) were defined and diagnostic performances of them for myocardial viability were evaluated using area under curve (AUC) on receiver operating characteristic (ROC) curve analysis. Results: Segmental perfusion measurements showed considerable normal variations among segments. In men, the lowest segmental perfusion measurement was $51.8{\pm}6.5$ and the highest segmental perfusion was $87.0{\pm}5.9$, and they are $58.7{\pm}8.1$ and $87.3{\pm}6.0$, respectively in women. In the viability assessment $Q_{delay}$ showed AUC of 0.633, while those for ${\Delta}_{delay}$ and $Z_{delay}$ were 0.735 and 0.716, respectively. The AUCs of ${\Delta}_{delay}$ and $Z_{delay}$ were significantly higher than that of $Q_{delay}$ (p = 0.001 and 0.018, respectively). The diagnostic performance of ${\Delta}_{delay}$, which showed highest AUC, was 85% of sensitivity and 53% of specificity at the optimal cutoff of -24.7. Conclusion: On automatic quantification of myocardial perfusion SPECT, the normal variation of perfusion measurements were considerable among segments. In the viability assessment, the parameters considering normal variation showed better diagnostic performance than the direct perfusion measurement. This study suggests that consideration of normal variation is important in the analysis of measurements on quantitative myocardial perfusion SPECT.

Evaluation of Result of CABG by Comparison of Pre-and Post-operative Myocardial SPECT (관동맥우회로술 전후의 디피리다몰 부하/휴식 심근 SPECT를 이용한 수술 결과의 평가)

  • Lee, Dong-Soo;Lee, Won-Woo;Kang, Keon-Wook;Hyun, In-Young;Kim, Ki-Bong;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.86-94
    • /
    • 1996
  • Coronary angiography should be performed to verify the patency of bypass graft if coronary artery disease is said to be surgically corrected. Rest/stress myocardial SPECT could be used as a noninvasive alternative to prove patency of bypass graft and functional significance of graft patency by showing improvement of rest perfusion and perfusion reserve after operation. We evaluated the outcome of coronary artery bypass graft surgery by comparing rest/dipyridamole-stress myocardial SPECT before and after operation. Myocardial SPECT were performed $19{\pm}23$ days before and $108{\pm}19$ days after operation in 44 patients(M:F=25:19). Segmental perfusion were scored with 0(normal) to 3(defect) independently for each image set of rest and stress. Perfusion scores were compared between pre and postoperative images. Rest/stress images of pre and post-operative SPECT were compared in paired sets. Postoperative change of perfusion was determined as no change, improvement or aggravation for each artery territory. Postoperative outcome of patients were analyzed. Overall, 74%(158 segments) of 215 segments which had perfusion decrease before operation showed improvement. Among 60 artery territories, 37 territories(62%) improved. Among 42 patients with perfusion decrease in preoperative SPECT, 21 patients(47%) improved after operation. Severe persistent defects improved in 43%(6/14). We concluded that bypass surgery improved myocardial perfusion in dipyridamole stress induced or persistent decrease and that rest/stress myocardial SPECT could be used as a guide for which artery should be operated.

  • PDF

Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using $^{99m}Tc$ ($^{99m}Tc$을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.65-71
    • /
    • 2011
  • Purpose: The recently adopted multiple confocal SPECT SYSTEM (hereinafter called IQ SPECT$^{TM}$) has a high difference from the conventional myocardial perfusion SPECT in the collimator form, image capture method, and image reconstruction method. This study was conducted to compare this novice equipment with the conventional one to design a protocol meeting the IQ SPECT, and also determine the characteristics and usefulness of IQ SPECT. Materials and Methods: 1. For the objects of LEHR (Low energy high resolution) collimator and Multiple confocal collimator, $^{99m}Tc$ 37MBq was put in the acrylic dish then each sensitivity ($cpm/{\mu}Ci$) was measured at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. 2. Based on the sensitivity measure results, IQ SPECT Protocol was designed according to the conventional general myocardial SPECT, then respectively 278 kBq/mL, 7.4 kBq/mL, and 48 kBq/mL of $^{99m}Tc$ were injected into the myocardial and soft tissues and liver site by using the anthropomorphic torso phantom then the myocardial perfusion SPECT was run. 3. For the comparison of FWHMs (Full Width at Half Maximum) resulted from the image reconstruction of LEHR collimator, the FWHMs (mm) were measured with only algorithms changed, in the case of the FBP (Filtered Back projection) method- a reconstruction method of conventional myocardial perfusion SPECT, and the 3D OSEM (Ordered subsets expectation maximization) method of IQ SPECT, by using $^{99m}Tc$ Line source. Results: 1. The values of IQ SPECT collimator sensitivity ($cpm/{\mu}Ci$) were 302, 382, 655, 816, 1178, and those of LEHR collimator were measured as 204, 204, 202, 201, 198, both at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. It was found the difference of sensitivity increases up to 4 times at the distance of 30 cm in the cases of IQ SPECT and LEHR. 2. The myocardial perfusion SPECT Protocol was designed according to the geometric characteristics of IQ SPECT based on the sensitivity results, then the phantom test for the aforesaid protocol was conducted. As a result, it was found the examination time can be reduced 1/4 compared to the past. 3. In the comparison of FWHMs according to the reconstructed algorithm in the FBP method and 3D OSEM method followed after the SEPCT test using a LEHR collimator, the result was obtained that FWHM rose around twice in the 3D OSEM method. Conclusion : The IQ SPECT uses the Multiple confocal collimator for the myocardial perfusion SPECT to enhance the sensitivity and also reduces examination time and contributes to improvement of visual screen quality through the myocardial-specific geometric image capture method and image reconstruction method. Due to such benefits, it is expected patients will receive more comfortable and more accurate examinations and it is considered a further study is required using additional clinical materials.

  • PDF

Analysis of Aggravated Perfusion in Myocardial SPECT after Coronary Artery Bypass Surgery (관동맥우회로술 후에 심근 SPECT에 나타난 관류의 악화 분석)

  • Lee, Won-Woo;Yoon, Seok-Nam;Kim, Ki-Bong;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.1
    • /
    • pp.36-42
    • /
    • 1997
  • Though myocardial perfusion was usually expected to improve after coronary artery bypass graft(CABG) surgery, some myocardial segments were aggravated after operation, as we compared perfusion changes on postoperative SPECT with preoperative ones. In this study, we evaluated perfusion changes after operation in rest and stress myocardial SPECT in 44 patients (M:F=25:19, age 57.1 $year{\pm}8.2$) who had CABG before and 3 months after operation. We tried to find out possible causes for perfusion aggravation with multivariate logistic regression analysis regarding whether bypass graft was artery or vein and which coronary artery territory was operated. Among 616 myocardial segments which were operated, 89(14.4%) aggravated after operation. In the univariate analysis, myocardial segments in the left circumflex arteries(LCx) aggravated more often(p<0.01) than others and segments having operative angioplasty did less often(p<0.01). Multivariate logistic regression revealed that LCx was risk factor for perfusion aggravation [odds ratio=2.54 (95% confidence interval : 1.53-4.22, p<0.01)]. However, this was not the case when we analysed in terms of arterial territories. Among 106 coronary arterial territories which were operated, 27(25.5%) aggravated. The territories having aggravated had similar characteristics regarding whether they received arterial or venous grafts, angioplasty and whether the operated territories were left anterior descending, right coronary or left circumflex arteries. In conclusion, myocardial segments in the left circumflex artery tended to aggravate more often after bypass surgery than the others. In short-term comparison of perfusion after surgery, we could not find any tendency that arterial or venous graft was associated with more frequency of the aggravation of perfusion after operation.

  • PDF