• Title/Summary/Keyword: myocardial imaging

Search Result 176, Processing Time 0.021 seconds

Clinical Study of Simultaneous Acquisition Rest 99mTc-sestaMIBI/Stress 201Tl Dual-Isotope Myocardial Perfusion Imaging with a Solid-State Dedicated Cardiac Gamma Camera (반도체 심근 전용 감마카메라를 이용한 Rest 99mTc-sestaMIBI/Stress201Tl 이중 동위원소 심근 관류 동시 스캔에 관한 임상적 고찰)

  • Bahn, Young-Kag;Kim, Dong-Heui;Choi, Yong-Hoon;Kang, Chun-Koo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.88-91
    • /
    • 2018
  • Purpose The purpose of this study is to investigate the simultaneous dual isotope (SDI) myocardial perfusion scan that can be performed in a short time using a semiconductor gamma camera. Materials and Methods Of the 86 patients who underwent Rest/Stress $^{99m}TC$-sestaMIBI 1-day myocardial perfusion scan and Rest $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope myocardial perfusion scan using a heart-only gamma camera, the test results were the same, 36 patients who did not show any change in the clinical outcome. Quantitative values were statistically analyzed using a QPS program to confirm the correlation between the images of the two examinations. Results Rest/Stress $^{99m}TC$-sestaMIBI simultaneous dual myocardial perfusion scans and $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ double-isotope myocardial perfusion scans were analyzed for Summed score. The $R^2$ value of the Rest summed score (RSS) was 0.91 and the $R^2$ value of the stress summed score (SSS) was 0.71. Conclusion The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan confirmed its correlation with the previous day's test. The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan can be completed in approximately 30minutes. It maybe clinically useful for patients who need short examination time such as emergency patients or elderly patients.

Unexpected Uptake of Tc-99m MIBI in Thymic Carcinoma: Ring-like Appearance (흉선암종에서 우연히 발견된 환 모양의 Tc-99m MIBI 섭취 증가)

  • Sohn, Myung-Hee;Jeong, Hwan-Jeong;Lim, Seok-Tae;Kim, Dong-Wook;Yim, Chang-Yeol
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.255-257
    • /
    • 2007
  • A 59-year-old man with thymic carcinoma underwent Tc-99m MIBI myocardial SPECT, and Tc-99m MIBI uptake in the mass was unexpectedly found in a planar image. SPECT images of the thorax showed an increased uptake area with central photon deficiency (a ring-like appearance), which reflected central tumor irreversible ischemia or progressing necrosis with peripheral viable tumor tissue.

Dexmedetomidine for Repeated Sedation in Pediatric Sedation During Consecutive Radiation Therapy

  • Kim, Eun-Jung;Baek, Seung-Hoon;Byeon, Gyeong-Jo;Woo, Mi-Na
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.14 no.4
    • /
    • pp.221-225
    • /
    • 2014
  • External beam radiotherapy (EBRT) causes anxiety and claustrophobia in pediatric patients. To provide exact figures and radiation amounts, an appropriate sedation or anesthesia can be supplied. Alpha 2 agonist dexmedetomidine has been used for sedation and anesthesia in pediatric imaging. Dexmedetomidine has an advantage because it has minimal respiratory depression and no direct effects on myocardial function. We report repeated sedation with dexmedetomidine for 33 consecutive radiation therapies in 5 years old children.

PET and PET/CT in Clinical Cardiology (심장 PET과 PET/CT의 임상적 이용)

  • Won, Kyoung-Sook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.124-132
    • /
    • 2005
  • Cardiac PET emerged as a powerful tool that allowed in vivo quantification of physiologic processes including myocardial perfusion and metabolism, as well as neuronal and receptor function for more than 25 years. Wow PET imaging has been playing an important role in the clinical evaluation of patients with known or suspected ischemic heart disease. This important clinical role is expected to grow with the availability of PET/CT scanner that allow a true integration of structure and function. The objective of this review is to provide an update on the current and future role of PET in clinical cardiology with a special eye on the great opportunities now offered by PET/CT.

Semi-Quantitative Scoring of Late Gadolinium Enhancement of the Left Ventricle in Patients with Ischemic Cardiomyopathy: Improving Interobserver Reliability and Agreement Using Consensus Guidance from the Asian Society of Cardiovascular Imaging-Practical Tutorial (ASCI-PT) 2020

  • Cherry Kim;Chul Hwan Park;Do Yeon Kim;Jaehyung Cha;Bae Young Lee;Chan Ho Park;Eun-Ju Kang;Hyun Jung Koo;Kakuya Kitagawa;Min Jae Cha;Rungroj Krittayaphong;Sang Il Choi;Sanjaya Viswamitra;Sung Min Ko;Sung Mok Kim;Sung Ho Hwang;Nguyen Ngoc Trang;Whal Lee;Young Jin Kim;Jongmin Lee;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.23 no.3
    • /
    • pp.298-307
    • /
    • 2022
  • Objective: This study aimed to evaluate the effect of implementing the consensus statement from the Asian Society of Cardiovascular Imaging-Practical Tutorial 2020 (ASCI-PT 2020) on the reliability of cardiac MR with late gadolinium enhancement (CMR-LGE) myocardial viability scoring between observers in the context of ischemic cardiomyopathy. Materials and Methods: A total of 17 cardiovascular imaging experts from five different countries evaluated CMR obtained in 26 patients (male:female, 23:3; median age [interquartile range], 55.5 years [50-61.8]) with ischemic cardiomyopathy. For LGE scoring, based on the 17 segments, the extent of LGE in each segment was graded using a five-point scoring system ranging from 0 to 4 before and after exposure according to the consensus statement. All scoring was performed via web-based review. Scores for slices, vascular territories, and total scores were obtained as the sum of the relevant segmental scores. Interobserver reliability for segment scores was assessed using Fleiss' kappa, while the intraclass correlation coefficient (ICC) was used for slice score, vascular territory score, and total score. Inter-observer agreement was assessed using the limits of agreement from the mean (LoA). Results: Interobserver reliability (Fleiss' kappa) in each segment ranged 0.242-0.662 before the consensus and increased to 0.301-0.774 after the consensus. The interobserver reliability (ICC) for each slice, each vascular territory, and total score increased after the consensus (slice, 0.728-0.805 and 0.849-0.884; vascular territory, 0.756-0.902 and 0.852-0.941; total score, 0.847 and 0.913, before and after implementing the consensus statement, respectively. Interobserver agreement in scoring also improved with the implementation of the consensus for all slices, vascular territories, and total score. The LoA for the total score narrowed from ± 10.36 points to ± 7.12 points. Conclusion: The interobserver reliability and agreement for CMR-LGE scoring for ischemic cardiomyopathy improved when following guidance from the ASCI-PT 2020 consensus statement.

Fusion of 3D Cardiac SPECT and 64-Channel-CT Angiography Using Personal Computer in Functionally Relevant Coronary Artery Stenosis (개인용 컴퓨터를 이용한 기능 유관성 관상동맥 협착증의 삼차원 심장스펙트 사진과 64채널 전산화 단층 혈관촬영사진과의 융합)

  • Bahk, Yong-Whee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.252-254
    • /
    • 2007
  • Image fusion is fast catching attention as Wagner pointed out in his 2006 version of the recent progress and development presented at the annual meeting of Society of Nuclear Medicine. Prototypical fusion of bone scan and radiograph was already attempted at in 1961 when Fleming et al. published an article on strontium-85 bone scan. They simply superimposed dot scan on radiograph enabling simultaneous assessment of altered bone metabolism and local bone anatomy. Indeed the parallel reading of images of bone scan and radiography, CT, MRI or ultrasonography has been practiced in nuclear medicine long since. It is fortunate that recent development of computer science and technology along with the availability of refined CT and SPECT machines has permitted us to open a new avenue to digitally produce precise fusion image so that they can readily be read, exchanged and disseminated using internet. Ten years ago fusion was performed using Bresstrahlung SPECT/CT and it is now achievable by PET/CT and SPECT/CT software and SPECT/CT hardware. The merit of image fusion is its feasibility of reliable assessment of morphological and metabolic change. It is now applicable not only to stationary organs such as brain and skeleton but also to moving organs such as the heart, lung and stomach. Recently, we could create useful fusion image of cardiac SPECT and 64-channel CT angiograph. The former provided myocardial metabolic profile and the latter vascular narrowing in two patients with coronary artery stenosis and myocardial ischemia. Arterial stenosis was severe in Case 1 and mild in Case 2.

Quantification of myocardial blood low using dynamic N-13 ammonia PET and actor analysis (N-13 암모니아 PET 동적영상과 요소분석을 이용한 심근 혈류량 정량화 방법 개발)

  • Kim, J.Y.;Choi, Y.;Im, K.C.;Choe, Y.S.;Lee, K.H.;Kim, S.E.;Kim, Y.J.;Kim, B.T.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.575-578
    • /
    • 1997
  • Myocardial blood low (MBF) in human can be noninvasively quantified using dynamic N-13 ammonia PET and two-compartment tracer kinetic model. In this study, factor analysis was used to extract the "pure" blood-pool time-activity curves (TACs) and to generate actor images. ive human N-13 ammonia PET dynamic studies were obtained. Three actors and their corresponding actor images were extracted rom each study. The accuracy of MBF estimated by the actor analysis (FA/FA MBF) was examined by comparing to the values estimated using the conventional ROI method (ROI/ROI MBF). MBF obtained by the actor analysis linearly correlated with MBF obtained by the ROI method (slope=0.98, r=0.91). Input unctions obtained by the two methods agreed well. In conclusion, MBF can be measured accurately and noninvasively with dynamic N-13 ammonia PET imaging and actor analysis. This method is simple and acurate and can measure MBF without blood sampling, ROI drawing nor spillover correction.

  • PDF

Feasibility of Coronary Angiography and Percutaneous Coronary Intervention via Left Snuffbox Approach

  • Kim, Yongcheol;Ahn, Youngkeun;Kim, Inna;Lee, Doo Hwan;Kim, Min Chul;Sim, Doo Sun;Hong, Young Joon;Kim, Ju Han;Jeong, Myung Ho
    • Korean Circulation Journal
    • /
    • v.48 no.12
    • /
    • pp.1120-1130
    • /
    • 2018
  • Background and Objectives: Feasibility of coronary angiography (CAG) and percutaneous coronary intervention (PCI) via left snuffbox approach is still concerned. We aimed to investigate efficacy and safety of the left snuffbox approach for CAG and PCI. Methods: Left snuffbox approach was tried in 150 patients who planned to perform CAG or PCI for suspected myocardial ischemia between 1 November 2017 and 31 March 2018. Results: Success rate of radial artery (RA) cannulation via snuffbox approach was 88.0% (n=132). Among 132 individuals, 58 (43.9%) acute coronary syndrome (ACS) patients were included. The diameter of snuffbox RA was significantly smaller than conventional RA (2.57 mm vs. 2.72 mm, p<0.001) from quantitative computed angiography of 101 patients. However, CAG via snuffbox approach by 6 French sheath was successfully performed in all 132 patients. In addition, there was significant correlation between the snuffbox and conventional RA diameter (r=0.856, p<0.001). In 42 PCI cases, including 25 patients with acute myocardial infarction (AMI), the success rate of PCI via snuffbox approach was 97.6% (n=41). Intravascular imaging-guided PCI was performed in 8 (19.5%) patients and multi-vessel PCI in 4 (9.8%) cases. Regarding vascular complication, forearm swelling with bruising, not requiring surgery or transfusion, occurred in 2 (4.9%) PCI cases. Conclusions: Left snuffbox approach is suitable for CAG and PCI compared with the conventional radial approach.

Beyond Coronary CT Angiography: CT Fractional Flow Reserve and Perfusion (전산화단층촬영 관상동맥조영술: 분획혈류예비력과 심근관류 영상)

  • Moon Young Kim;Dong Hyun Yang;Ki Seok Choo;Whal Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.3-27
    • /
    • 2022
  • Cardiac CT has been proven to provide diagnostic and prognostic evaluation of coronary artery disease for cardiovascular risk stratification and treatment decision-making based on rapid technological development and various research evidence. Coronary CT angiography has emerged as a gateway test for coronary artery disease that can reduce invasive angiography due to its high negative predictive value, but the diagnostic specificity is relatively low. However, coronary CT angiography is likely to overcome its limitations through functional evaluation to identify the hemodynamic significance of coronary artery disease by analyzing myocardial perfusion and fractional flow reserve through cardiac CT. Recently, studies have been actively conducted to incorporate artificial intelligence to make this more objective and reproducible. In this review, functional imaging techniques of cardiac computerized tomography are explored.

Analysis of Myocardial Function Using Gated Myocardial SPET : Comparison of QGS, 4D-MSPECT Software and Echocardiography (게이트 심근관류 SPECT를 이용한 심기능 분석: 정량분석 소프트웨어 QGS, 4D-MSPECT 및 심초음파법의 비교)

  • Lee, Seok-Mo;Bae, Sang-Kyun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.435-443
    • /
    • 2008
  • Purpose: Gated myocardial perfusion SPECT provides not only myocardial perfusion status but also various functional parameters of left ventricle. We compared left ventricular ejection fraction, end-diastolic volume, LV mass by cardiac SPECT using Quantitative Gated SPECT (QGS), 4D-MSPECT software and standard 2D-echocardiography. Materials and Methods: One hundred fourteen patients (male 51, female 63; 29-85 years old, mean $61.3\;{\pm}\;13.3$ years old) with normal perfusion status on Tc-99m tetrofosmin gated myocardial perfusion SPECT were analyzed retrospectively. Ejection fraction (LVEF), End-diastolic volume (LVED), LV mass (LVM) were calculated using QGS, 4D-MSPECT, and LVEF, LVM using 2D-echocardiography. Statistical analysis including Bland-Altman plot was performed using $MedCalc^{(R)}$ (MedCalc software, Mariakerke, Belgium). Results: The correlation of LVEF between methods was good: 0.95/0.96 (stress/rest) between QGS and 4D-MSPECT, 0.79 between QGS and echocardiography, 0.79 between 4D-MSPECT and echocardiography (p<0.001). Using Bland-Altman plot, the 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -12.7% to 7.3% / from -12.2% to 6.5% (stress/rest). The agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -17.4% to 24.0%, and -14.8% to 27.0% respectively. The correlation of LVM between methods was also good: 0.95 between QGS and 4D-MSPECT, 0.76 between QGS and echocardiography, 0.73 between 4D-MSPECT and echocardiography (p<0.001). The 95% confidence interval of agreement between QGS and 4D-MSPECT ranged from -33.8g to 14.1g (stress/rest), The 95% confidence interval of agreement between QGS and echocardiography, 4D-MSPECT and echocardiography ranged from -148.7 g to 21.8. g, and -142.8 g to 35.5 g, respectively. Conclusion: There was a good correlation for LVEF, LVEO, LVM among methods (QGS, 4D-MSPECT, echocardiography), but the variance between methods was big. Therefore, the functional parameters by each method cannot be used interchangeably.